Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PHASE DETECTOR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 883 records · Page 49

SU-E-T-423: TrueBeam Small Field Dosimetry Using Commercial Plastic Scintillation and Other Stereotactic Detectors

Purpose: To perform dose profile and output factor (OF) measurements with the Exradin W1 plastic scintillation detector (PSD) for small fields made by the high-definition multi-leaf collimator (MLC) on the TrueBeam STx system and to compare them to values measured with an IBA CC01 ionization chamber and a Sun Nuclear Edge detector diode for 6 MV photon beams. Methods: The Exradin W1 is a new small volume near-water equivalent and energy independent PSD manufactured by Standard Imaging, Inc. All measurements were performed in an IBA Blue Phantom water tank. Square MLC-shaped fields with sides ranging from 0.5 cm to 2 cm and jawshaped fields with sides ranging from 1 cm to 40 cm were measured using an SAD setup at 10 cm depth. Dose profile and percent depth dose (PDD) measurements were also taken under the same conditions for MLC fields 0.5×0.5 and 1×1 cm2 in size with jaws at 2×2cm2. The CC01 and W1 were vertically mounted. Results: OFs measured with the W1 for jaw only square fields were consistent with the ones measured with a Farmers PTW TN33013 ion chamber (1.8% maximum deviation). OF and penumbra measurement results are presented below. PDDs measured for all detectors are within 1.5% for the 0.5×0.5 cm2 and within 1% for the 1×1 cm2 MLC fields.Output factors:MLC size W1 CC01 EDGE0.5cm 0.555 0.541 0.5851.0cm 0.716 0.702 0.7331.5cm 0.779 0.761 0.7772.0cm 0.804 0.785 0.796Penumbras (mm):MLC size W1 CC01 EDGE0.5cm 2.7 2.9 2.51.0cm 3.0 3.4 2. Conclusion: OFs measured for small MLC fields were consistent with the ones measured with the other stereotactic detectors. Measured penumbras are consistent with detector size. The Exradin W1 PSD is an excellent choice for characterizing MLC-shaped small beam dosimetry used for stereotactic radiosurgery and body radiation therapy. Sam Beddar would like to disclose a NIH/NCI SBIR Phase II grant (2R44CA153824-02A1) with Standard Imaging, Title: “Water-Equivalent Plastic Scintillation Detectors for Small Field Radiotherapy”.

07 ISOTOPE AND RADIATION SOURCES↗

A modified detector concept for SuperCDMS: The HiZIP and its charge performance

SuperCDMS (Super Cryogenic Dark Matter Search) is a leading direct dark mat-ter search experiment which uses solid state detectors (Ge crystals) at milliKelvintemperatures to look for nuclear recoils caused by dark matter interactions in the de-tector. `Weakly Interacting Massive Particles' (WIMPs) are the most favoured darkmatter candidate particles. SuperCDMS, like many other direct dark matter searchexperiments, primarily looks for WIMPs. The measurement of both the ionizationand the lattice vibration (phonon) signals from an interaction in the detector allow itto discriminate against electron recoils which are the main source of background forWIMP detection.SuperCDMS currently operates about 9 kg of Ge detectors at the Soudan under-ground lab in northern Minnesota. In its next phase, SuperCDMS SNOLAB plansto use 100-200 kg of target mass (Ge) which would allow it to probe more of theinteresting and and as of yet unexplored parameter space for WIMPs predicted bytheoretical models. The SuperCDMS Queen's Test Facility is a detector test facilitywhich is intended to serve as detector testing and detector research and developmentpurposes for the SuperCDMS experiment.A modifed detector called the HiZIP (Half-iZIP), which is reduced in complex-ity in comparison to the currently used iZIP (interleaved Z-sensitive Ionization and Phonon mediated) detectors, is studied in this thesis. The HiZIP detector designalso serves to discriminate against background from multiple scatter events occurringclose to the surfaces in a single detector. Studies carried out to compare the surfaceevent leakage in the HiZIP detector using limited information from iZIP data takenat SuperCDMS test facility at UC Berkley produce a highly conservative upper limitof 5 out of 10,000 events at 90% condence level. This upper limit is the best amongmany different HiZIP congurations that were investigated and is comparable to theupper limit calculated for an HiZIP detector in the same way using the same data. Areal HiZIP device operated at the Queen's Test Facility produced an exposure lim-ited 90% upper limit of about 1 in 100 events for surface event leakage. The dataused in these studies contain true nuclear recoil events from cosmogenic and ambientneutrons. This background was not subtracted in the calculation of the upper limitsstated above and hence they are highly conservative.A surface event source was produced by depositing210Pbfrom radon exposureonto a copper plate. This source was then used to take data for a surface eventdiscrimination study of the HiZIP detector operated at the Queen's Test Facility.A study of the contribution of the noise from capacitive crosstalk between chargesensors in a HiZIP detector configuration was investigated, conrming the expectationthat no signicant drop in performance compared to an HiZIP is to be expected dueto this effect.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Phase-retrieval algorithms for a complicated optical system

Phase-retrieval algorithms have been developed that handle a complicated optical system that requires multiple Fresnellike transforms to propagate from one end of the system to the other including the absorption by apertures in more than one plane and allowance for bad detector pixels. Gradient-search algorithms and generalizations of the iterative-transform phase-retrieval algorithms are derived. Analytic expressions for the gradient of an error metric, with respect to polynomial coefficients and with respect to point-by-point phase descriptions, are given. The entire gradient can be computed with the number of transforms required to propagate a wave front from one end of the optical system to the other and back again, independent of the number of coefficients or phase points. This greatly speeds the computation. The reconstruction of pupil amplitude is also given. A convergence proof of the generalized iterative transform algorithm is given. These improved algorithms permit a more accurate characterization of complicated optical systems from their point spread functions.

Fienup, J. R.↗

Studies of a Proton Bunch Phase Monitor for Range Verification in Proton Therapy

A primary subject of the present research in particle therapy is to ensure the precise irradiation of the target volume. The prompt gamma timing (PGT) method provides one possibility for in vivo range verification during the irradiation of patients. Prompt gamma rays with high energies are emitted promptly due to nuclear reactions of protons with tissue. The arrival time of these gammas to the detector reflects the stopping process of the primary protons in tissue and is directly correlated to the range. Due to the time resolution of the detector and the proton bunch time spread, as well as drifts of the bunch phase with respect to the accelerator frequency, timing spectra are smeared out and compromise the accuracy of range information intended for future clinical applications. Nevertheless, counteracting this limitation and recovering range information from the PGT measured spectra, corrections using a bunch phase monitor can be performed. A first prototype of bunch phase monitor was tested at GSI Darmstadt, where measurements of the energy correlation profile of the ion bunches were performed. At the ELBE accelerator at Helmholtz-Zentrum Dresden-Rossendorf (HZDR), set up to provide bremsstrahlung photons in very short pulses, a constant fraction algorithm for the incoming digital signals was evaluated, which is used for optimizing the time resolution. Studies of scattering experiments with different thin targets and detector positions are accomplished at Onco Ray Dresden, where a clinical proton beam is available. These experiments allow a basic characterization of the proton bunch structure and the detection yield. (authors)

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Maximum Likelihood Estimation of the Broken Power Law Spectral Parameters with Detector Design Applications

The method of Maximum Likelihood (ML) is used to estimate the spectral parameters of an assumed broken power law energy spectrum from simulated detector responses. This methodology, which requires the complete specificity of all cosmic-ray detector design parameters, is shown to provide approximately unbiased, minimum variance, and normally distributed spectra information for events detected by an instrument having a wide range of commonly used detector response functions. The ML procedure, coupled with the simulated performance of a proposed space-based detector and its planned life cycle, has proved to be of significant value in the design phase of a new science instrument. The procedure helped make important trade studies in design parameters as a function of the science objectives, which is particularly important for space-based detectors where physical parameters, such as dimension and weight, impose rigorous practical limits to the design envelope. This ML methodology is then generalized to estimate broken power law spectral parameters from real cosmic-ray data sets.

Howell, Leonard W.↗

Studies of a proton phase beam monitor for range verification in proton therapy

A primary subject of the present research in particle therapy is to ensure the precise irradiation of the target volume. The prompt gamma timing (PGT) method provides one possibility for in vivo range verification during the irradiation of patients. Prompt gamma rays with high energies are emitted promptly due to nuclear reactions of protons with tissue. The arrival time of these gammas to the detector reflects the stopping process of the primary protons in tissue and are directly correlated to the range. Due to the time resolution of the detector and the proton bunch time spread, as well as drifts of the bunch phase with respect to the accelerator frequency, timing spectra are smeared out and compromise the accuracy of range information intended for future clinical applications. Nevertheless, counteracting this limitation and recovering range information from the PGT measured spectra, corrections using a phase beam monitor can be performed. A first prototype of phase beam monitor was tested at GSI Darmstadt, where measurements of the energy profile of the ion bunches were performed. At the ELBE accelerator Helmholtz-Zentrum Dresden-Rossendorf (HZDR), set up to provide bremsstrahlung photons in very short pulses, a constant fraction algorithm for the incoming digital signals was evaluated, which is used for optimizing the time resolution. Studies of scattering experiments with different thin targets and detector positions are accomplished at Oncoray Dresden, where a clinical proton beam is available. These experiments allow a basic characterization of the proton bunch structure and the detection yield. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Homodyning and heterodyning the quantum phase

The double-homodyne and the heterodyne detection schemes for phase shifts between two synchronous modes of the electromagnetic field are analyzed in the framework of quantum estimation theory. The probability operator-valued measures (POM's) of the detectors are evaluated and compared with the ideal one in the limit of strong local reference oscillator. The present operational approach leads to a reasonable definition of phase measurement, whose sensitivity is actually related to the output r.m.s. noise of the photodetector. We emphasize that the simple-homodyne scheme does not correspond to a proper phase-shift measurements as it is just a zero-point detector. The sensitivity of all detection schemes are optimized at fixed energy with respect to the input state of radiation. It is shown that the optimal sensitivity can be actually achieved using suited squeezed states.

Dariano, Giacomo M.↗

US ATLAS and US CMS HPC and Cloud Blueprint

The Large Hadron Collider (LHC) at CERN houses two general purpose detectors - ATLAS and CMS - which conduct physics programs over multi-year runs to generate increasingly precise and extensive datasets. The efforts of the CMS and ATLAS collaborations lead to the discovery of the Higgs boson, a fundamental particle that gives mass to other particles, representing a monumental achievement in the field of particle physics that was recognized with the awarding of the Nobel Prize in Physics in 2013 to François Englert and Peter Higgs. These collaborations continue to analyze data from the LHC and are preparing for the high luminosity data taking phase at the end of the decade. The computing models of these detectors rely on a distributed processing grid hosted by more than 150 associated universities and laboratories worldwide. However, such new data will require a significant expansion of the existing computing infrastructure. To address this, both collaborations have been working for years on integrating High Performance Computers (HPC) and commercial cloud resources into their infrastructure and continue to assess the potential role of such resources in order to cope with the demands of the new high luminosity era. US ATLAS and US CMS computing management have charged the authors to provide a blueprint document looking at current and possibly future use of HPC and Cloud resources, outlining integration models, possibilities, challenges and costs. The document will address key questions such as the optimal use of resources for the experiments and funding agencies, the main obstacles that need to be overcome for resource adoption, and areas that require more attention.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Quantum parameter estimation in the Unruh–DeWitt detector model

Relativistic effects on the precision of quantum metrology for particle detectors, such as two-level atoms are studied. The quantum Fisher information is used to estimate the phase sensitivity of atoms in non-inertial motions or in gravitational fields. The Unruh–DeWitt model is applicable to the investigation of the dynamics of a uniformly accelerated atom weakly coupled to a massless scalar vacuum field. When a measuring device is in the same relativistic motion as the atom, the dynamical behavior of quantum Fisher information as a function of Rindler proper time is obtained. It is found out that monotonic decrease in phase sensitivity is characteristic of dynamics of relativistic quantum estimation. The origin of the decay of quantum Fisher information is the thermal bath that the accelerated detector finds itself in due to the Unruh effect. To improve relativistic quantum metrology, we reasonably take into account two reflecting plane boundaries perpendicular to each other. The presence of the reflecting boundary can shield the detector from the thermal bath in some sense.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Development of POTATO for 2S Module Grading for the CMS Phase-2 Outer Tracker Upgrade

Due to the High Luminosity-Large Hadron Collider (HL-LHC) upgrade, several detectors of the Compact Muon Solenoid (CMS) will need to be upgraded, specifically the new Outer Tracker detector that will be composed of 13,200 silicon modules. The Outer Tracker features two types of modules; the PS (pixel-strip) and the 2S (strip-strip) modules. With a large influx of production of modules, extensive testing is required to ensure they fulfill the performance requirements. This research introduces POTATO (Phase-II Outer Tracker Analyzer of Test Outputs), a specialized software developed in C++ to analyze, grade, and store results in a centralized database since module data will be collected from various international production facilities. The implementation of POTATO will facilitate the selection of the best performing modules for the Outer Tracker upgrade. This paper is focused on the implementation of the analysis of 2S Module results within POTATO.

43 PARTICLE ACCELERATORS↗

Modeling impurity concentrations in liquid argon detectors

Impurities in noble liquid detectors used for neutrino and dark matter experiments can significantly impact the quality of data. We present an experimentally verified model for describing the dynamics of impurity distributions in liquid argon (LAr) detectors. The model considers sources, sinks, and transport of impurities within and between the gas and liquid argon phases. Measurements of oxygen concentrations in a 20-L LAr multi-purpose test stand are compared to calculations made with this model to show that an accurate description of the concentrations under various operational conditions can be obtained. A result of this analysis is a determination of Henry’s coefficient for oxygen in LAr. Additionally, these calculations also show that some processes have small effects on the impurity dynamics and excluding them yields a solution as a sum of two exponential terms. This solution provides a simple way to extract Henry’s coefficient with negligible approximation error. It is applied to the data and the Henry’s coefficient for oxygen in LAr is obtained as 0.84 +0.09 -0.05 , consistent with literature results. Finally, based on the analysis of the data with the model, we further suggest that, for a large liquid argon detector, barriers to flow (“baffles”) installed in the gas phase to restrict flow can help reduce the ultimate impurity concentration in the LAr.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

IXO/XMS Detector Trade-Off Study

This document presents the outcome of the detector trade-off for the XMS instrument on IXO. This trade-off is part of the Cryogenic instrument Phase-A study as proposed to ESA in the Declaration of Interest SRONXMS-PL-2009-003 dated June 6, 2009. The detector consists of two components: a core array for the highest spectral resolution and an outer array to increase the field of view substantially with modest increase in the number of read-out channels. Degraded resolution of the outer array in comparison with the core array is accepted in order to make this scheme possible. The two detector components may be a single unit or separate units. These arrays comprise pixels and the components that allow them to be arrayed. Each pixel comprises a thermometer, an absorber, and the thermal links between them and to the rest of the array. These links may be interfaces or distinct components. The array infrastructure comprises the mechanical structure of the array, the arrangement of the leads, and features added to improve the integrated thermal properties of the array in the focal-plane assembly.

Kilbourne, Caroline Anne↗

Numerical phase space optics methods and applications to the analysis of fiber coupling efficiency in atmospheric turbulence

A fundamental requirement of free-space optical communication is the ability to efficiently couple atmospherically distorted light from a telescope to a detector. A numerical method is presented for modeling fiber-based receiver performance in atmospheric conditions based on phase space optics which does not rely on Monte Carlo methods. This method is employed to analyze the waveguide insertion loss and optimal coupling geometry in atmospheric conditions for step-index fibers, graded-index fibers, and photonic lanterns with and without tilt compensation and central obscurations in the telescope.

free-space optical communication↗

Numerical phase space optics methods and applications to the analysis of fiber coupling efficiency in atmospheric turbulence

A fundamental requirement of free-space optical communication is the ability to efficiently couple atmospherically distorted light from a telescope to a detector. A numerical method is presented for modeling fiber-based receiver performance in atmospheric conditions based on phase space optics which does not rely on Monte Carlo methods. This method is employed to analyze the waveguide insertion loss and optimal coupling geometry in atmospheric conditions for step-index fibers, graded-index fibers, and photonic lanterns with and without tilt compensation and central obscurations in the telescope.

free-space optical communication↗

Soil Segregation Methods for Reducing Transportation and Disposal Costs - 13544

At Formerly Utilized Sites Remedial Action Program (FUSRAP) sites where the selected alternative for contaminated soil is excavation and off-site disposal, the most significant budget items of the remedial action are the costs for transportation and disposal of soil at an off-site facility. At these sites, the objective is to excavate and dispose of only those soils that exceed derived concentration guideline levels. In situ soil segregation using gross gamma detectors to guide the excavation is often challenging at sites where the soil contamination is overlain by clean soil or where the contaminated soil is located in isolated, subsurface pockets. In addition, data gaps are often identified during the alternative evaluation and selection process, resulting in increased uncertainty in the extent of subsurface contamination. In response, the U.S. Army Corps of Engineers, Buffalo District is implementing ex situ soil segregation methods. At the remediated Painesville Site, soils were excavated and fed through a conveyor-belt system, which automatically segregated them into above- and below-cleanup criteria discharge piles utilizing gamma spectroscopy. At the Linde Site and the Shallow Land Disposal Area (SLDA) Site, which are both in the remediation phase, soils are initially segregated during the excavation process using gross gamma detectors and then transported to a pad for confirmatory manual surveying and sampling. At the Linde Site, the ex situ soils are analyzed on the basis of a site-specific method, to establish compliance with beneficial reuse criteria that were developed for the Linde remediation. At the SLDA Site, the ex situ soils are surveyed and sampled based on Multi-Agency Radiation Survey and Site Investigation Manual (MARSSIM) final status survey guidance to demonstrate compliance with the derived concentration guideline levels. At all three sites, the ex situ soils that meet the site- specific DCGLs are retained on-site and used as backfill material. This paper describes the ex situ soil segregation methods, the considerations of each method, and the estimated cost savings from minimizing the volume of soil requiring transportation and off-site disposal. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Optical detectors for GaAs MMIC integration: Technology assessment

Fiber optic links are being considered to transmit digital and analog signals in phased array antenna feed networks in space communications systems. The radiating elements in these arrays will be GaAs monolithic microwave integrated circuits (MMIC's) in numbers ranging from a few hundred to several thousand. If such optical interconnects are to be practical it appears essential that the associated components, including detectors, be monolithically integrated on the same chip as the microwave circuitry. The general issue of monolithic integration of microwave and optoelectronic components is addressed from the point of view of fabrication technology and compatibility. Particular attention is given to the fabrication technology of various types of GaAs optical detectors that are designed to operate at a wavelength of 830 nm.

Claspy, P. C.↗

Optical detectors for GaAs MMIC integration - Technology assessment

Fiber optic links are being considered to transmit digital and analog signals in phased array antenna feed networks in space communications systems. The radiating elements in these arrays will be GaAs monolithic microwave integrated circuits (MMIC's) in numbers ranging from a few hundred to several thousand. If such optical interconnects are to be practical it appears essential that the associated components, including detectors, be monolithically integrated on the same chip as the microwave circuitry. The general issue of monolithic integration of microwave and optoelectronic components is addressed from the point of view of fabrication technology and compatibility. Particular attention is given to the fabrication technology of various types of GaAs optical detectors that are designed to operate at a wavelength of 830 nm.

Claspy, P. C.↗