Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Operating systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 883 records · Page 49

Operation of a High Renewable Penetrated Power System With CSP Plants: A Look-Ahead Stochastic Unit Commitment Model

The integration of variable renewable energy (VRE) generation, i.e., wind power and solar photovoltaic, brings significant uncertainty for the power system operation. Different with VRE techniques, concentrating solar power (CSP) is an appealing renewable generation technology due to its dispatch ability through the use of thermal energy storage and is thus expected to play a significant role in high renewable energy penetrated power systems. In this paper, we propose a look-ahead stochastic unit commitment model to operate power systems with CSP under high renewable energy penetration. It has a three-stage structure. The first stage optimizes the operational decisions in a day-ahead framework based on forecasts; the second stage minimizes the expected generation cost for possible realizations in the real time; and the third stage accounts for look-ahead operation in future operating days. This paper has a dual purpose: first, exploring how CSP plants operate in high renewable penetrated power systems; and second, analyzing the benefits of CSP in accommodating VRE generation. A case study on a modified IEEE RTS-79 system with actual solar and wind power data is provided to validate the proposed method.

14 SOLAR ENERGY↗

Power Sector Resilience Planning Guidebook: A Self-Guided Reference for Practitioners

The provision of reliable, secure, and affordable electricity is essential to power economic growth and development. The power system is at risk from an array of natural, human-caused, and technological threats, which can cause everything from power interruption to chronic undersupply of energy. It is critical for policymakers, planners, and system operators to safeguard their power systems from these threats by proactively planning for future needs and investing in resilient power systems. This guidebook is a reference for power sector resilience planning that introduces policymakers, power sector investors, planners, system operators, and other energy-sector stakeholders to the key concepts and steps involved in power sector resilience planning. Users can then apply this knowledge in the development of strategic, country-specific processes and identify actions that increase power sector resilience. This guidebook can be used as a stand-alone resource or shared with participants at stakeholder workshops to facilitate discussions and complete key steps of a resilience planning process.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Smart Infrared Inspection System Field Operational Test (Final Report)

The Smart InfraRed Inspection System (SIRIS) is a tool designed to assist inspectors in determining which vehicles passing through the SIRIS system are in need of further inspection by measuring the thermal data from the wheel components. As a vehicle enters the system, infrared cameras on the road measure temperatures of the brakes, tires, and wheel bearings on both wheel ends of commercial motor vehicles (CMVs) in motion. This thermal data is then presented to enforcement personal inside of the inspection station on a user friendly interface. Vehicles that are suspected to have a violation are automatically alerted to the enforcement staff. The main goal of the SIRIS field operational test (FOT) was to collect data to evaluate the performance of the prototype system and determine the viability of such a system being used for commercial motor vehicle enforcement. From March 2010 to September 2010, ORNL facilitated the SIRIS FOT at the Greene County Inspection Station (IS) in Greeneville, Tennessee. During the course of the FOT, 413 CMVs were given a North American Standard (NAS) Level-1 inspection. Of those 413 CMVs, 384 were subjected to a SIRIS screening. A total of 36 (9.38%) of the vehicles were flagged by SIRIS as having one or more thermal issues; with brakes issues making up 33 (91.67%) of those. Of the 36 vehicles flagged as having thermal issues, 31 (86.11%) were found to have a violation and 30 (83.33%) of those vehicles were placed out-of-service (OOS). Overall the enforcement personnel who have used SIRIS for screening purposes have had positive feedback on the potential of SIRIS. With improvements in detection algorithms and stability, the system will be beneficial to the CMV enforcement community and increase overall trooper productivity by accurately identifying a higher percentage of CMVs to be placed OOS with minimal error. No future evaluation of SIRIS has been deemed necessary and specifications for a production system will soon be drafted.

brake system↗

Bibliography On Multiprocessors And Distributed Processing

Multiprocessor and Distributed Processing Bibliography package consists of large machine-readable bibliographic data base, which in addition to usual keyword searches, used for producing citations, indexes, and cross-references. Data base contains UNIX(R) "refer" -formatted ASCII data and implemented on any computer running under UNIX(R) operating system. Easily convertible to other operating systems. Requires approximately one megabyte of secondary storage. Bibliography compiled in 1985.

Miya, Eugene N.↗

PC-CUBE: A Personal Computer Based Hypercube

PC-CUBE is an ensemble of IBM PCs or close compatibles connected in the hypercube topology with ordinary computer cables. Communication occurs at the rate of 115.2 K-band via the RS-232 serial links. Available for PC-CUBE is the Crystalline Operating System III (CrOS III), Mercury Operating System, CUBIX and PLOTIX which are parallel I/O and graphics libraries. A CrOS performance monitor was developed to facilitate the measurement of communication and computation time of a program and their effects on performance. Also available are CXLISP, a parallel version of the XLISP interpreter; GRAFIX, some graphics routines for the EGA and CGA; and a general execution profiler for determining execution time spent by program subroutines. PC-CUBE provides a programming environment similar to all hypercube systems running CrOS III, Mercury and CUBIX. In addition, every node (personal computer) has its own graphics display monitor and storage devices. These allow data to be displayed or stored at every processor, which has much instructional value and enables easier debugging of applications. Some application programs which are taken from the book Solving Problems on Concurrent Processors (Fox 88) were implemented with graphics enhancement on PC-CUBE. The applications range from solving the Mandelbrot set, Laplace equation, wave equation, long range force interaction, to WaTor, an ecological simulation.

Ho, Alex↗

Gaseous fuel engine system and operating strategy for limiting crankcase fuel accumulation

Operating a gaseous fuel engine system includes controlling at least one of a delivery location, a delivery timing, or in situ mixing of a gaseous fuel with air, based on at least one engine system parameter upon the basis of which a blowby amount of a gaseous fuel to a crankcase varies. Crankcase accumulation of the gaseous fuel is maintained below a flammability limit. Related apparatus and control logic is also disclosed.

Singh, Jaswinder↗

Faster-than-real-time Simulation with Demonstration for Resilient DER Integration

The US electric grid is facing operational, stability, and security challenges. Transmission system operators need some measure of visibility into distribution system renewable generation. Distribution system generation needs to support transmission system voltage. The grid is experiencing an expansion in measurement systems. How to take full advantage of this expansion and defend against attacks, both cyber and physical, poses additional challenges. The Faster-than-real-time Simulation with demonstration for Resilient DER Integration project set out to do the following: a. Flatten the voltage profile through the feeders and system for cost saving and voltage stabilization needs. b. Increase the amount of intermittent distributed energy resources (IDERs) that could be deployed on a utility feeder and provide 100% or more energy needed for the demands on that feeder, and c. based on an accurate model (Digital Twin) of the utilities system, be able to detect any abnormalities on the utilities distribution system. To manage the voltage and increase IDER penetration (a,b), Graph Trace Analysis is employed in a time-series, optimal power flow to coordinate the time-varying feedback control setpoints of a distribution feeder’s utility control devices. Under the coordinated control are a Load Tap Changing Transformer, a voltage regulator, and five switched capacitor banks. The feeder serves over 2000 customers, the feeder secondaries are modeled, and the feeder has 2.3 MW of PV generation, corresponding to a 17.4% penetration of PV generation. The feeder model has over 12,000 components, where every customer load bus and PV generator are modeled. The accuracy of the power flow solution is compared against historical meter voltage measurements, the improvement in conservation voltage reduction energy savings as a function of the coordinated control desired voltage profile is investigated, and the increase in PV penetration of the coordinated control over the existing control is presented. To achieve improved control performance while observing system operation constraints, bellwether Advanced Metering Infrastructure (AMI) voltage measurements are used to adjust the desired voltage profile used by the optimal power flow analysis. To detect and alleviate or negate attacks or failures on the distribution and transmission utility grids (c) the grid needs to be resilient and self-healing. In this project software was designed to do just that. At the center of the software is an Integrated System Model (ISM) that spans from transmission to secondary distribution. The ISM is employed in real-time abnormality detection, voltage stability forecasting, and multi-mode control. Testing results are presented for: 1—attacks on utility infrastructure; 2—energy savings from optimal control; 3—distribution system control response during a low voltage transmission system event; 4—cyber-attacks on PV inverters, where physical inverters are used in hard-ware-in-the-simulation-loop studies. Contributions of this work include real-time analysis that spans from three-phase transmission through secondary distribution; an approach for detecting abnormalities that employs measurements from three independent measurement systems; and a multi-mode distribution system control that responds to cyber-attacks, physical attacks, equipment failures, and transmission system needs.

Integrated System Model, Graph Trace Analysis, Adv↗

Economical and Engineering Aspects of Proactive Demand Participation: Centralized versus Bilateral Control Structure

The electric grid of the U.S. is evolving from a system characterized by large and centralized fossil-fueled power plants and passive customers to a network with high penetration of distributed energy resources and proactive customers. This project facilitated the evolution of the U.S. electric power grid by enabling proactive participation of demands in electricity market at the power distribution system level. This project has three major achievements. First, we designed a centralized distribution system operator managed electricity market and developed a three-phase alternating current optimal power flow algorithm to coordinate the operation of large-scale flexible loads and distributed energy resources. Second, we designed a decentralized bilateral coordinate framework for retail electricity market, where each participating customer is capable of making decisions regarding energy production and consumption based on information received from transactive neighbors. Third, the impacts of centralized and decentralized demand-side participation scheme on power system operations were evaluated with both large-scale simulations and hardware-in-the-loop demonstrations. The major activities and specific accomplishments of the technical tasks are summarized in Section II. The detailed design of centralized/hierarchical and decentralized/bilateral retail electricity markets and the comparison between the two markets are described in Section III. The accomplishments and conclusions of the project are presented in Section IV. The major findings of the project falls into three areas, hierarchical distribution system operator managed electricity market, bilateral electricity market and decentralized market coordination, and comparison of centralized and decentralized market coordination mechanisms. In the area of hierarchical distribution system operator managed electricity market design, an integrated wholesale and retail electricity market was shown to be highly effective in extracting the operational flexibility from distributed energy resources to provide services to the wholesale market. A chordal conversion based convex iteration algorithm is not only computationally efficiency but also achieves global optimal solution in coordinating the operations of a large number of heterogeneous distributed energy resources.In the area of decentralized market coordination approach, we showed that bilateral transactions among proactive customers and decentralized transaction clearing mechanism based on simultaneous second-price sealed-bid auction can encourage truthful bidding strategies from the market participations. In addition, the individual customers can rely on a portfolio optimization approach to maximize their returns while minimizing risks. In the area of comparison of centralized and decentralized market coordination mechanisms, we found that the centralized market design results in higher social welfare and lower wholesale market clearing price for electricity. In general, centralized market design favors distributed energy resources and fixed loads. The decentralized market design mostly benefits flexible loads and conventional generators.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Flight Computer Processing Avionics for Space Station Microgravity Experiments: A Risk Assessment of Commercial Off-the-Shelf Utilization

NASA/Marshall Space Flight Center (MSFC) is continually looking for ways to reduce the costs and schedule and minimize the technical risks during the development of microgravity programs. One of the more prominent ways to minimize the cost and schedule is to use off-the-shelf hardware (OTS). However, the use of OTS often increases the risk. This paper addresses relevant factors considered during the selection and utilization of commercial off-the-shelf (COTS) flight computer processing equipment for the control of space station microgravity experiments. The paper will also discuss how to minimize the technical risks when using COTS processing hardware. Two microgravity experiments for which the COTS processing equipment is being evaluated for are the Equiaxed Dendritic Solidification Experiment (EDSE) and the Self-diffusion in Liquid Elements (SDLE) experiment. Since MSFC is the lead center for Microgravity research, EDSE and SDLE processor selection will be closely watched by other experiments that are being designed to meet payload carrier requirements. This includes the payload carriers planned for the International Space Station (ISS). The purpose of EDSE is to continue to investigate microstructural evolution of, and thermal interactions between multiple dendrites growing under diffusion controlled conditions. The purpose of SDLE is to determine accurate self-diffusivity data as a function of temperature for liquid elements selected as representative of class-like structures. In 1999 MSFC initiated a Center Director's Discretionary Fund (CDDF) effort to investigate and determine the optimal commercial data bus architecture that could lead to faster, better, and lower cost data acquisition systems for the control of microgravity experiments. As part of this effort various commercial data acquisition systems were acquired and evaluated. This included equipment with various form factors, (3U, 6U, others) and equipment that utilized various bus structures, (VME, PC104, STD bus). This evaluation of hardware was performed in conjunction with a trade study that considered over twenty (20) different factors relevant to the selection of an optimum design approach. These factors included; safety, sizing and timing, radiation hardness and single event upset, power consumption, heat dissipation, size and volume, expected service life, maintainability, heritage, operating systems, requirements for software reuse, availability of compatible interface boards, relative cost, schedule, reliability, EMI/EMC factors, "hot swap" capability, standards for conduction cooling, I/O capabilities, unique carrier requirements and operating system considerations. The approach to evaluate Safety as part of this study included a review of the Preliminary Hazard Analysis (PHA) for each of the experiment designs and a determination of how each hazard could be addressed and eliminated when different processors were selected. This included evaluating various design approaches and trade-offs between fault tolerant designs and fail-safe designs in accordance with NSTS 1700.7B. This will include the results of radiation testing where available. Various operating systems, such as VxWorks, Linux, QNX, and Embedded NT are evaluated and the advantages and disadvantages of their utilization are also addressed. Design implementation strategies for the various operating systems are considered and discussed. This paper presents the results and recommendations from this trade study. Preliminary conclusions from this study are that safety concerns from lack or radiation testing on COTS equipment can be addressed by additional testing and design considerations, the PC104 bus provided adequate I/O for the SDLE and EDSE microgravity experiments, and PC104 bus components offered significant advantages over VME and cPCI for weight and space reductions.

Estes, Howard↗

Long Duration Exposure Facility (LDEF) low-temperature heat pipe experiment package power system results

An overview of a self-contained Direct Energy Transfer Power System which was developed to provide power to the Long Duration Exposure Facility (LDEF) Low-Temperature Heat Pipe Experiment Package is presented. The power system operated successfully for the entire mission. Data recorded by the onboard recorder shows that the system operated within design specifications. Other than unanticipated overcharging of the battery, the power system operated as expected for nearly 32,000 low earth orbit cycles, and was still operational when tested after the LDEF recovery. Some physical damage was sustained by the solar array panels due to micrometeoroid hits, but there were not electrical failures.

Tiller, Smith E.↗

Global Power System Transformation Consortium

The Global Power System Transformation (G-PST) Consortium, an expert- and practitioner-driven initiative, engages key power system operators, research and educational institutes, governments, businesses, and stakeholders in all regions of the world to accelerate clean energy transitions at the ambitious scope and scale that is required. The G-PST Consortium provides coordinated, holistic support and knowledge infusion for system operators pursuing clean energy transitions, including performing cutting-edge research; providing implementation support for world-class engineering and operational solutions; supporting workforce development; building and disseminating open-access data and tools; and accelerating localized technology adoption, standards development, and testing programs.

consortium↗

MAX - An advanced parallel computer for space applications

MAX is a fault-tolerant multicomputer hardware and software architecture designed to meet the needs of NASA spacecraft systems. It consists of conventional computing modules (computers) connected via a dual network topology. One network is used to transfer data among the computers and between computers and I/O devices. This network's topology is arbitrary. The second network operates as a broadcast medium for operating system synchronization messages and supports the operating system's Byzantine resilience. A fully distributed operating system supports multitasking in an asynchronous event and data driven environment. A large grain dataflow paradigm is used to coordinate the multitasking and provide easy control of concurrency. It is the basis of the system's fault tolerance and allows both static and dynamical location of tasks. Redundant execution of tasks with software voting of results may be specified for critical tasks. The dataflow paradigm also supports simplified software design, test and maintenance. A unique feature is a method for reliably patching code in an executing dataflow application.

Lewis, Blair F.↗

AI-Guided Reasoning-Based Operator Support System for the Nuclear Power Plant Management

The Decision-making process in the Nuclear Power Plant (NPP) control room faces some challenges: operator incomplete knowledge, insufficient time for responding to the highly dynamic events, and a large number of indicators to monitor. Because of the complexity of the NPP system, it is hard to pre-plan all the failures/mitigative actions. An intelligent operator support system is vital to mitigate these shortcomings. In this paper, an AI declarative approach (Answer Set Programming (ASP)) is employed to represent our knowledge of the nuclear power plant in the form of logic rules. This represented knowledge is structured to form a reasoning-based operator support system. When an incident occurs, this ASP-based reasoning support system is demonstrated to be capable of fault identification (diagnosis), informing the operator of different scenarios and consequences, and generating the control options (decision making).

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Powertrain control system and method of operating the same

A system and method are provided for operating a powertrain control system. The method includes receiving data measured from a plurality of sensors, the measured data relating to distance dependent speed values, and receiving information from one or more vehicle modules, the vehicle module information relating to distance independent speed values. The method further includes building a speed trajectory profile for a horizon window that includes a plurality of speed change regions represented by at least some distance dependent speed values or at least some distance independent speed values, and creating a synthesized speed profile for the horizon window by processing the speed trajectory profile. The synthesized speed profile optimizes efficiency of the powertrain control system at each of the plurality of speed change regions.

33 ADVANCED PROPULSION SYSTEMS↗

Mobile radio interferometric geodetic systems

Operation of the Astronomical Radio Interferometric Earth Surveying (ARIES) in a proof of concept mode is discussed. Accuracy demonstrations over a short baseline, a 180 km baseline, and a 380 km baseline are documented. Use of ARIES in the Sea Slope Experiment of the National Geodetic Survey to study the apparent differences between oceanographic and geodetic leveling determinations of the sea surface along the Pacific Coast is described. Intergration of the NAVSTAR Global Positioning System and a concept called SERIES (Satellite Emission Radio Interferometric Earth Surveying) is briefly reviewed.

Macdoran, P. F.↗

Securing Your ICS Software with the AttackSurface Host Analyzer (AHA)

Implementing a secure development lifecycle (SDL) presents increasing challenges to software developers as they must ensure software correctly integrates both underlying operating system security features while also managing dependencies on third-party libraries or executables. There are a growing number of security functions that require a close integration between the OS security features and software builds to ensure strong protection. Furthermore, as software platforms grow in complexity, they present many opportunities for misconfigurations and inadequate defenses. This challenge is especially prevalent for industrial control systems (ICS), which oten depend on both legacy sotware platforms, or out of date operating systems. This paper presents the AttackSurface Host Analyzer (AHA) tool, which is used to assess the security of a software platform through its integration with a host operating system. The tool collects data from the various platforms running on an OS, evaluates an array of security properties, and then introduces metrics and visualizations to provide feedback on the system's attack surface based on the external interconnections and the completeness of the available security protections. The paper then explores the attack surface of a variety of industry-standard ICS platforms to provide insight into the current degree of protection enabled by them.

24 POWER TRANSMISSION AND DISTRIBUTION↗