Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “OUTDOORS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 883 records · Page 49

Identification and overexpression of endogenous transcription factors to enhance lipid accumulation in the biotechnologically relevant species Chlamydomonas pacifica

Sustainable low-carbon energy solutions are critical to mitigating global carbon emissions. Algae-based platforms offer potential by converting carbon dioxide into valuable products while aiding carbon sequestration. However, scaling algae cultivation faces challenges like contamination in outdoor systems. Previously, our lab evolved Chlamydomonas pacifica, an extremophile green alga, which tolerates high temperature, pH, salinity, and light, making it ideal for large-scale bioproduct production, including biodiesel. Here, we enhanced lipid accumulation in evolved C. pacifica by identifying and overexpressing key endogenous transcription factors through genome-wide in-silico analysis and in-vivo testing. These factors include Lipid Remodeling Regulator 1 (CpaLRL1), Nitrogen Response Regulator 1 (CpaNRR1), Compromised Hydrolysis of Triacylglycerols 7 (CpaCHT7), and Phosphorus Starvation Response 1 (CpaPSR1). Under nitrogen deprivation, CpaLRL1, CpaNRR1, and CpaCHT7 overexpression enhanced lipid accumulation compared to wild-type. However, CpaPSR1 increased lipid accumulation compared to wild-type in normal media and did not increase further under nitrogen deprivation, highlighting the difference in function based on media conditions. Notably, lipid analysis of CpaPSR1 under normal media conditions revealed a 2.4-fold increase in triglycerides (TAGs) compared to the wild-type, highlighting its potential for biodiesel production. This approach provides a framework for transcription factor-focused metabolic engineering in algae, advancing bioenergy and biomaterial production.

Biofuels↗

Evaluation of microalgae cultivation at air-CO 2 equilibrium pH for improving carbon utilization efficiency

Microalgae are often cultivated at near-neutral pH to optimize growth. However, this results in significant CO 2 loss through outgassing in open-pond cultivation systems, leading to low CO 2 utilization efficiency and higher biomass production costs. One potential solution is algal cultivation at air-CO 2 equilibrium pH, which minimizes CO 2 outgassing but may inhibit growth due to stresses at higher pH levels. In this study, we evaluated the viability of this approach by growing Picochlorum celeri and Tetraselmis striata under outdoor relevant conditions at equilibrium pH. Compared to pH 7 cultures, biomass productivity declined by 35 % for P. celeri and 57 % for T. striata. Although CO 2 outgassing could be minimized, the significant loss in productivity led to a higher overall minimum biomass selling price (MBSP). Increased ammonia toxicity at the higher pH was found to be one of the growth-limiting factors and was mitigated by reducing ammonium fertilizer concentration. This adjustment resulted in a more moderate productivity decline of 13 % (instead of 35 %) for T. striata, and consequently, a lower MBSP was achieved. These findings suggest that equilibrium pH cultivation may be a viable method for reducing CO 2 loss without significantly compromising biomass productivity. Depending on the strain, strategies to mitigate stressors, such as ammonia toxicity, may be necessary.

09 BIOMASS FUELS↗

Autonomous monitoring of algal biomass: Success stories and lessons learned from long-term field deployment

Autonomous, high-frequency monitoring of outdoor algal ponds is needed to quantify biomass productivity and detect culture decline in environments prone to contamination, grazers, and variable operating conditions. We report successes and lessons learned in translating a laboratory spectroradiometric monitoring approach to a multi-year autonomous field deployment at the Arizona Center for Algae Technology and Innovation (AzCATI). The system measures spectrally resolved pond reflectance by ratioing upwelling radiance from each raceway to simultaneous downwelling sky irradiance using fiber-coupled spectrometers. A physics-based reflectance model (ASHARP) is fit to each spectrum pair to estimate optical parameters, including a biomass-proxy coefficient (C a ) which enables near-real-time tracking of biomass accumulation and culture state at 2–5 min intervals. From May 2022 through September 2025 the platform operated continuously while scaling from two to six raceway ponds. Several strains of algae were monitored successfully, including the high productivity Tetraselmis striata and Picochlorum celeri. Transitioning data acquisition from a Windows laptop to a Raspberry Pi improved uptime from 57% (2022) to ~89% (2024–2025) and enabled routine real-time analysis. Further, we converted relative biomass estimates to absolute ash-free dry weight (AFDW) using experimentally-derived calibrations, providing field-relevant biomass predictions with conservative confidence bounds. These results demonstrate the feasibility of long-term, autonomous optical monitoring for well-mixed open-raceway algal cultivation and provide practical guidance for reliable field operation and scaling.

Katinas, Christopher Michael [Sandia National Labo↗

Data and Analytics to Inform Energy Retrofit of High Performance Buildings

Buildings consume more than one-third of the world?s primary energy. Reducing energy use in buildings with energy efficient technologies is feasible and also driven by energy policies such as energy benchmarking, disclosure, rating, and labeling in both the developed and developing countries. Current energy retrofits focus on the existing building stocks, especially older buildings, but the growing number of new high performance buildings built around the world raises a question that how these buildings perform and whether there are retrofit opportunities to further reduce their energy use. This is a new and unique problem for the building industry. Traditional energy audit or analysis methods are inadequate to look deep into the energy use of the high performance buildings. This study aims to tackle this problem with a new holistic approach powered by building performance data and analytics. First, three types of measured data are introduced, including the time series energy use, building systems operating conditions, and indoor and outdoor environmental parameters. An energy data model based on the ISO Standard 12655 is used to represent the energy use in buildings in a three-level hierarchy. Secondly, a suite of analytics were proposed to analyze energy use and to identify retrofit measures for high performance buildings. The data-driven analytics are based on monitored data at short time intervals, and cover three levels of analysis ? energy profiling, benchmarking and diagnostics. Thirdly, the analytics were applied to a high performance building in California to analyze its energy use and identify retrofit opportunities, including: (1) analyzing patterns of major energy end-use categories at various time scales, (2) benchmarking the whole building total energy use as well as major end-uses against its peers, (3) benchmarking the power usage effectiveness for the data center, which is the largest electricity consumer in this building, and (4) diagnosing HVAC equipment using detailed time-series operating data. Finally, a few energy efficiency measures were identified for retrofit, and their energy savings were estimated to be 20percent of the whole-building electricity consumption. Based on the analyses, the building manager took a few steps to improve the operation of fans, chillers, and data centers, which will lead to actual energy savings. This study demonstrated that there are energy retrofit opportunities for high performance buildings and detailed measured building performance data and analytics can help identify and estimate energy savings and to inform the decision making during the retrofit process. Challenges of data collection and analytics were also discussed to shape best practice of retrofitting high performance buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Transmissive microfluidic active cooling for concentrator photovoltaics

We present the design, fabrication, characterization, and field testing of transmissive active cooling for use in a point-focus spectrum-splitting hybrid concentrator photovoltaics/thermal (CPV/T) system. Seven parallel-path 100 μm thick microchannels are made using polydimethylsiloxane and attached to a CPV module containing a 6 × 6 array of 5.5 mm transmissive CPV cells on a sapphire substrate. Water is flowed through the microchannels to actively cool the CPV cells. The total transmittance of the CPV module reduces by 5.2% with the addition of the active cooling microchannels, relative to the module transmission with no microchannels. The peak cell temperature is measured as 69 °C with a thermal resistance of 9.35 K/W at 157 suns, well below the 110 °C maximum allowed temperature. A maximum flowrate of 16.7 g/s is achieved from a 13 psi pressure drop across the microchannels and manifold assembly. The flow characteristics within each microfluidic channel show maximum fluid velocity of 4.3 m/s (Re = 953) with a calculated convection coefficient of 1.7 × 10 4 W/m 2 K (Nu = 5.36). The CPV/T module and cooling system performance was validated during week-long outdoor tests under varying solar conditions up to 250 suns using a 2.7 m 2 parabolic dish collector mounted to a two-axis tracking system.

14 SOLAR ENERGY↗

Performance evaluation of a metamaterial-based new cool roof using improved Roof Thermal Transfer Value model

A new cool roof with potential to generate significant energy savings in buildings has been developed from a metamaterial film named as RadiCold. Considering that the RadiCold film has unique optical and thermal characteristics and the current Roof Thermal Transfer Value model neglecting the effect of roof thermal mass that may lead to overestimating the cooling load from roofs, this work developed an improved Roof Thermal Transfer Value model and validated the model for both RadiCold cool roof and traditional roofing structures. Data from the reduced-size model building experiments showed that the improved Roof Thermal Transfer Value model can accurately describe the heat gains or losses via the roofs. Under real-world weather conditions in the United States (Tucson AZ, Los Angeles, CA, and Orlando FL), the improved Roof Thermal Transfer Value model has been applied to three types of roof exterior finishing: shingle, Thermoplastic Polyolefin (a cool roof material) and RadiCold. In a typical meteorology year, the modeling results show that the shingle and Thermoplastic Polyolefin roof transfer 78.9–294.1 kWh/(m 2 ·yr) and 8.5–128.2 kWh/(m 2 ·yr) of heat into the building space, respectively, but the RadiCold cool roof dissipates 137.6–268.7 kWh/(m 2 ·yr) of heat from the building space to outdoor environment (e.g., sky). The cooling load reduction from utilizing RadiCold cool roof results in cooling electricity savings of 113.0–143.9 kWh/(m 2 ·yr) compared to the shingle roof and 88.0–92.4 kWh/(m2·yr) compared to the Thermoplastic Polyolefin roof for the three analyzed locations with an assumed air conditioning system’s coefficient of performance of 3.0.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Nationwide HVAC Energy-Saving Potential Quantification for Office Buildings with Occupant-Centric Controls in Various Climates

The occupant-centric control (OCC) is receiving an increasing attention due to its ability to reduce building heating ventilation and air-conditioning (HVAC) system energy consumptions while not affecting the occupant thermal comfort. This paper aims to investigate and quantify the nationwide energy-saving potential of implementing the occupant-centric HVAC controls in typical office buildings using a whole building simulation software EnergyPlus. First, the medium office and large office from the Department of Energy (DOE) Commercial Prototype Building Models (CBPM) were enhanced to have detailed layouts and dynamic occupancy schedules. Then, a comprehensive simulation plan was created by incorporating the multiple zone-level and system-level occupant-centric building HVAC controls recommended by the updated ASHRAE Standard 90.1 – 2019 and ASHRAE Guideline 36 – 2018. Three control scenarios with different occupancy sensing methods were identified in this simulation plan. A nation-wide parametric analysis which includes two building types, three occupancy sensing scenarios, two building code versions, and 16 U.S. climate zones was carried out. The simulation results of the key control variables and HVAC energy consumption suggest that generally, both the occupancy presence sensor and occupant counting sensor could achieve energy savings for the office buildings in majority of the scenarios. However, compared with the occupancy presence sensor, which could support both the temperature setpoint reset and operational breathing zone airflow rate reset for the unoccupied zones, the occupant counting sensor only brings a marginal benefit. Besides, a higher HVAC energy-saving ratio could be achieved in the heating-dominated zone, since the energy reduction brought with the minimum outdoor airflow rate reset is stronger in the heating mode.

Pang, Zhihong↗

Enhancing building energy performance by effectively using phase change material and dynamic insulation in walls

Deploying phase change materials (PCMs) in building envelopes can be efficacious in reducing space heating/cooling loads and providing load shedding and shifting capacity. However, the full potential of PCM-integrated envelopes can only be harnessed if the PCM undergoes phase change using free ambient heating/cooling, and the stored energy is effectively transferred between the exterior and the interior environments. Traditional thermal insulation (with a fixed thermal resistance) limits PCM utilization, which restrains the energy saving potential of a PCM-integrated envelope to a small percentage. Proposed dynamic insulation material and system (DIMS) provides the option of varying its thermal resistance based on the indoor and outdoor conditions. Although it has been established that employing PCM as well as DIMS in building envelopes separately improves buildings’ energy performance, no prior studies that analyzed the combined influence of both technologies were identified. In this study, we examine a novel wall design, comprising a layer of PCM between two layers of DIMS. We note that the PCM-DIMS-integrated wall provides significantly higher energy saving potential than the DIMS-only integrated wall or the PCM-only integrated wall in all the climates and wall orientations analyzed in this study. Depending on the climate, the PCM-DIMS-integrated wall could provide 15–72% reduction in annual heat gain and 7–38% reduction in annual heat loss. The analysis presented in this study supports the need to develop scalable dynamic insulations combined with thermal energy storage systems for buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A transmissive concentrator photovoltaic module with cells directly cooled by silicone oil for solar cogeneration systems

Hybrid concentrator photovoltaic-thermal systems can cogenerate electricity and heat by beam-splitting incoming concentrated light onto photovoltaic cells and a thermal receiver to increase total conversion efficiency and potentially reduce system cost. To demonstrate this, we have designed and prototyped a transmissive spectrum-splitting concentrator photovoltaic module that maximizes solar energy conversion by utilizing the entire solar spectrum. Visible light is collected using infrared-transmissive triple-junction photovoltaic cells to achieve an in-band module efficiency of 43.3% for light of wavelength λ < 873 nm, while 44.2% of out-of-band light with λ > 873 nm is transmitted through for collection by a thermal receiver. During testing on a dual-axis tracked parabolic concentrator dish at up to 166 suns, cell temperatures were maintained at 119 °C or below via a novel active cooling method. This cooling system strictly flows silicone oil directly across both sides of the cells, without inhibiting optical transmission, as verified through experimentation and simulation. The module was validated outdoors for 572 sun·hrs, and achieved a maximum thermal receiver temperature of 180 °C. 86.1% of incident solar power is collected at 166 suns average concentration collectively among the electrical, cooling, and thermal receiver subsystems. The remaining 13.9% is lost to mirror reflectivity, dish shadowing, receiver reflection, and thermal losses. The ability to directly cool the cells with an inert silicone oil offers the potential for reduced system cost relative to previous transmissive hybrid concentrator photovoltaic-thermal systems, including microfluidic-cooled designs. This solar cogeneration capability is valuable in a wide range of commercial and industrial applications.

14 SOLAR ENERGY↗

Open-cycle thermochemical energy storage for building space heating: Practical system configurations and effective energy density

Salt-hydrate thermochemical materials (TCM) are promising candidates for energy storage systems for building space heating due to their high theoretical energy density and the need for low regeneration temperature. However, water vapor is required to drive the hydration process of the TCM reactor, which poses a challenge during winter when water vapor is typically scarce. Using indoor air directly lowers the building's humidity to an unconformable level in practice, while the cold outdoor air contains limited moisture. Here we consider different integration strategies for open-cycle TCM reactors in buildings and develop a model to simulate their thermal performance across diverse buildings and climates, specifically for building space heating. The potential energy densities and the levelized cost of storage of the TCM reactor are evaluated in practical scenarios to demonstrate the load-shifting potential of TCM systems for heating applications. We use a strontium chloride (SrCl 2 )-based composite as the baseline and explore the impact of various reactor and material changes to the energy density and levelized cost of storage.

25 ENERGY STORAGE↗

Investigation of ventilation-coupled high energy density sensible thermal energy storage

Low-cost energy storage will play an important role in supporting the decarbonization of the energy sector. Here, a novel approach to thermal energy storage for buildings is proposed, in which a tank of antifreeze liquid can be used to heat outdoor air in mechanical ventilation systems. If heated to a high enough temperature, the fluid can potentially undergo temperature swings of nearly 100°C during discharge in cold climates. Because the energy density of sensible storage systems scales proportionally to the system temperature change, this concept has the potential to offer higher energy densities than other liquid-based sensible storage devices used in building applications. A one-dimensional numerical model of the storage system was developed and experimentally validated using 30 wt% (wt%) potassium acetate as an aqueous antifreeze solution. Using a commercial hot water tank, energy densities of 47.0 kW-hour per cubic meter (kWh/m 3 ) were demonstrated in a laboratory setting. Material energy densities of approximately 74.7 (kWh/m 3 ) were measured. Design improvements may boost this energy storage density even further. Because of the system's relative simplicity, ventilation-coupled sensible storage has the potential to be an easily deployable, low-cost energy storage solution for building systems.

25 ENERGY STORAGE↗

Performance assessment of radiant cooling system integrated with desiccant assisted DOAS with solar regeneration

The Radiant cooling system integrated with Dedicated Outdoor Air System (DOAS) is a viable substitution for conventional all air system in order to reduce primary energy consumption, as it decouples the cooling and ventilation task. In DOAS major portion of energy is consumed in cooling coil where it dehumidifies the process supply air. This study describes an alternate solution for dehumidification, with the substitution of the desiccant wheel with solar regeneration in place of a chilled water coil based dehumidifier. In this paper, simulations were carried out using EnergyPlus on a reference medium office building to investigate the contribution of solar energy towards the total energy consumption of desiccant assisted DOAS with radiant cooling system. To evaluate the system performance and energy saving potential, desiccant based DOAS is compared with cooling coil assisted DOAS integrated with Radiant cooling system. Simulations were carried out for different solar collector area to evaluate primary energy savings. Results indicate that from 7.4 % to 28.6 % energy saving (according to different collector area) can be achieved due to the solar regeneration in desiccant assisted DOAS, the impact of different solar collector area on potential of energy savings is also described.

42 ENGINEERING↗

Variability of absorption heat pump efficiency for domestic water heating and space heating based on time-weighted bin analysis

Natural gas-driven absorption heat pumps are under renewed scrutiny as a viable technology for space conditioning and water heating for residential and commercial applications because of natural gas production trends, pricing, and the speculation that it might be a “bridge fuel” in the global transition towards energy sustainability. Since any level of natural gas combustion contributes to atmospheric carbon dioxide accumulation, the merits of natural gas consuming absorption technology are re-examined in this paper from the point of view of expected efficiency throughout the United States using a time-weighted bin temperature analysis. Such analyses are necessary because equipment standards for rated performance is restricted to one set ambient condition, whereas in actual practice, the absorption heat pump (AHP) must perform over a considerably wider range of external conditions, where its efficiency may be vastly different from that at the rated condition. Quantification of variation in efficiency and system performance are imperative to address how to provide the desired utility with the least environmental impact. In this paper, we examine limiting features in absorption heat pumps and relate it to systemic performances in sixteen cities across all eight climate zones in the U.S, each containing fifteen bin temperatures. The results indicate that the true expectation of performance of an AHP is significantly less than what might be optimized for the rated condition. Statistical measures of the variation in water heating COPs show that for most cities, the COP at the rated conditions is outside the 95% Confidence Interval. Moreover, it is concluded that deployment of absorption heat pump water heaters (AHPWH) may be restricted geographically by outdoor temperature constraints.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Numerical and experimental analysis of precooled desiccant system

This paper presents a numerical and experimental study of four novel, desiccant air-conditioning systems based on pre-cooling of the ambient air. The purpose of the study is to: 1) establish which configuration is most profitable for the future studies through numerical and experimental methods; 2) verify the concept of precooled system and confirm that it is working in experimental conditions (for this purpose two prototypes of evaporative cooling units were developed and compared for different operation arrangements with desiccant wheel); 3) Analyze practical aspects of the systems, which includes water consumption analysis, economic analysis and establishing operational modes during a cooling season in temperate climate conditions (the proposed solution has a significant advantage during operation in a temperate climate, since it can utilize its first evaporative cooler the only source of cooling energy when the humidity of outdoor air allows to to meet the latent cooling load). Four arrangements of the system with different dew point evaporative air cooler prototypes were selected and developed for comparative analysis. The system was simulated as a whole, also, each component was individually tested on measurement station. develop the optimal arrangement of the system through numerical and experimental analysis. Four different performance indicators were considered: thermal COP (Coefficient Of Performance), the ERR (Energy Efficiency Ratio), coefficient a describing the potential in compensating indoor cooling loads, water consumption ratio. Also costs of the systems were compared through economic analysis. It was established that arrangement which is characterized by best-averaged performance in terms of all considered factors is a unit combined with two different types of evaporative coolers (marked as System B)- this is caused by the favorable arrangement of two units, where one is better suited to the pre-cooler role, while the other is better suited as the post-cooler.

42 ENGINEERING↗

Multi-stage heat pump with two-phase injection for cold climate applications implementing natural refrigerants

Heat pump adoption in cold climates is limited by various technical challenges, including heat capacity degradation, compressor deterioration, and frost accumulation on the outdoor heat exchanger. Furthermore, wide-spread adoption of heat pumps with high global warming potential presents a possible environmental concern. Thus, we present a heat pump concept termed the “saturation cycle,” which uses numerous compression stages to improve energy efficiency and injects two-phase refrigerant between compression stages to dramatically reduce compressor discharge temperatures. Given the growing interest in heat pumps, there is a need for a straightforward framework for parametric evaluation of natural refrigerants in high-efficiency heat pump cycle architectures, like the saturation cycle, in adverse climates. This work develops a thermodynamic modeling framework and focuses on the application of natural refrigerants to explore the performance trends at extremely cold climates down to −25 °C. This study shows that a two-stage saturation cycle and four-stage saturation cycle can reduce the compressor discharge superheating by up to 51–57 % or 73–80 %, respectively, depending on the refrigerant. Furthermore, at −25 °C, a two-stage R-290 saturation cycle heat pump theoretically can use 25 % less power than a single-stage heat pump or can provide up to 59 % more heating capacity when using the same compressor power as the baseline single-stage heat pump. The exergetic parametric analyses show that two-phase refrigerant injection fundamentally improves the thermodynamic performance of the heat pump, reducing overall exergy destruction by 10 % compared to a vapor-injection heat pump, compared at −25 °C. Thus, the saturation cycle is a promising heat pump cycle architecture for cold climate applications due to its superior energy savings (or capacity improvement) and substantial de-superheating capabilities.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Development and evaluation of a multi-functional heat pump with embedded thermal storage

We developed and tested a novel multi-functional packaged vertical heat pump designed for multi-family buildings, capable of providing space cooling, space heating, water heating, and energy storage integration. The system employs a 3-speed scroll compressor and supports energy-efficient cooling and heating across different ambient conditions, while utilizing both indoor and outdoor air sources for water heating. Key performance metrics include an integrated energy efficiency ratio of 18.0 for cooling, a heating seasonal performance factor of 10.0, and a coefficient of performance (COP) of 2.1 for heating in cold climates down to −15 ˚C. Additionally, the system delivers an annual water heating COP greater than 4.0, with outstanding performance in combined space cooling and water heating modes, achieving a total COP of 8.8 by recovering condenser waste heat. The heat pump also demonstrated thermal energy storage capabilities, integrating with phase change material systems to store heating and cooling energy. Furthermore, this versatile system offers a promising solution for improving energy efficiency and sustainability in multi-family buildings, providing high-performance heating, cooling, and water heating across a range of climates.

COP↗

Statistical optimization of culture media for growth and lipid production of Chlorella protothecoides UTEX 250

The concentration of NaNO 3 , MgSO 47 H 2 O and proteose, in Chlorella protothecoides medium were optimized for algal biomass and lipid production by using response surface methodology with Box-Behnken design. The optimal concentrations were 0.45 g/L of NaNO 3 , 6 mg/L of MgSO 47 H 2 O, and 0.25 g/L of proteose for maximum biomass production and 2 mg/L of MgSO 47 H 2 O and no addition of NaNO 3 and proteose for lipid accumulation. In optimized biomass production medium, a final biomass concentration of 1.19 g/L was obtained, which was 1.8 times higher than that in the original medium. For lipid accumulation, a 12.9% lipid content was obtained from the biomass in the lipid production medium, which was three times higher than that from the original medium. The fatty acid profile of algae grown in the optimized medium demonstrated a higher unsaturated fatty acid content (i.e. methyl linoleate (C18:2) and methyl linolenate (C18:3)) than that of the algae grown in the original medium. The results provide a strategy for limiting the amount of nutrients required in large scale outdoor cultivation systems of C. protothecoides to make the production of algal biomass more economically attractive.

09 BIOMASS FUELS↗