Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “OPTICAL SYSTEMS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 883 records · Page 49

Optical design and synthetic analysis of the electron cyclotron emission imaging diagnostic of HL-2M tokamak

The electron cyclotron emission imaging (ECEI) diagnostic is a powerful tool to study the MHD and turbulent transport in magnetically confined fusion plasmas. In this work, the optical system including the local oscillator (LO) coupling and radio frequency (RF) receiving optics, has been designed and analyzed for the HL-2M ECEI diagnostic. The LO optics can illuminate the antenna array and drive the mixer diode to work efficiently, with more than 36% of the beam intensity for the channels which probe the plasma edge relative to those of channels which probe the plasma core. The RF optics aims at guiding the plasma emission signal to the antenna array. To meet different physical requirements, three types of field of view have been achieved for the plasma imaging, with zoom factors of around 1, 1.5 and 2, respectively. The focal surfaces are almost flat, with a maximum off-mapping (defined as the radial distance between the beam waists of the lower-/uppermost antennas and electron cyclotron emission layer) less than 2.5 cm, which can match the electron cyclotron emission layer quite well and suppress the image distortion in the plasma edge region. Furthermore, the impact of possible vibrations and installation error on the focal plane has been evaluated. In addition, the predefined MHD and turbulence perturbations are well reproduced by combining the optical simulation results and synthetic ECEI modeling, which further verifies the good performance of the RF optics.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Analysis of spatial pseudodepolarizers in imaging systems

The objective of a number of optical instruments is to measure the intensity accurately without bias as to the incident polarization state. One method to overcome polarization bias in optical systems is the insertion of a spatial pseudodepolarizer. Both the degree of depolarization and image degradation (from the polarization aberrations of the pseudodepolarizer) are analyzed for two depolarizer designs: (1) the Cornu pseudodepolarizer, effective for linearly polarized light, and (2) the dual Babinet compensator pseudodepolarizer, effective for all incident polarization states. The image analysis uses a matrix formalism to describe the polarization dependence of the diffraction patterns and optical transfer function.

Mcguire, James P., Jr.↗

Derivation of closed-form ellipsoidal X-ray mirror shapes from Fermat's principle

Ellipsoidal and plane-elliptical surfaces are widely used as reflective, point-to-point focusing elements in many optical systems, including X-ray optics. Here the classical optical path function approach of Fermat is applied to derive a closed-form expression for these surfaces that are uniquely described by the object and image distances and the angle of incidence at a point on a mirror surface. A compact description facilitates design, modeling, fabrication, and testing to arbitrary accuracy. Congruent surfaces in two useful coordinate systems — a system centered on the ellipsoid's axes of symmetry and a mirror-centered or `vertex' system with the surface tangent to the xy plane at the mirror's center — are presented. Expressions for the local slope and radii of curvature are derived from the result, and the first several terms of the Maclauren series expansion are provided about the mirror center.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Communication system uses modulated laser beam

Electro-optical system is placed on a satellite to effect communications between two remote stations. The system employs an essentially passive, retrodirective, laser beam modulator-reflector.

Minott, P. O.↗

A proposed laser measurement system for determining surface contour

Electro-optical system can scan a large /100 ft./ antenna in 30 seconds. Comparison of the reflected signal with a reference signal from a Pockel-cell modulator driver yields a signal that can be correlated with the distance covered by the laser. A scanning arrangement then enables contour measurement.

Neubert, H. D.↗

Measurement of structure motion by means of a moving light sheet

The elaboration of an optical system which measures the displacement and velocity of large flexible space structures is reviewed. The motion-measuring system, comprised of a laser, optics, motorized mirror, two photodiodes and electronics, is designed to allow feedback for configuration control of flexible structures. A motor or scanner is employed to sweep the light sheet. The range of motion was shown to be 2 inches, and information was received at a rate of 30 Hz. The uncertainty in displacement measurement was better than +0.01 inch from a distance of 16 feet. The results are considered to be very good for two scanning light sheet systems. Higher sample rates and a more constant speed would improve the rotating mirror option, and the accuracy and range of the scanning mirror option could be upgraded as well. Both setups are shown to be viable noncontact measuring methods for the displacement and velocity of large space structures.

Tcheng, Ping↗

Precision optical angular position marker system for rotating machinery

An optical system is described which generates one or more markers of the angular shaft position of rotating machinery. The system consists of a light source, an optical cable, a machinery mounted lens assembly, a light detector, and a signal conditioner. Light reflected by targets on the rotor is converted to a digital output signal. The system is highly immune to extreme environments of vibration and temperature and achieved a 0.002 percent precision under operational test conditions.

Barranger, J. P.↗

Colossal Optical Anisotropy from Atomic-Scale Modulations

Materials with large birefringence (Δn, where n is the refractive index) are sought after for polarization control (e.g., in wave plates, polarizing beam splitters, etc.), nonlinear optics, micromanipulation, and as a platform for unconventional light–matter coupling, such as hyperbolic phonon polaritons. Layered 2D materials can feature some of the largest optical anisotropy; however, their use in most optical systems is limited because their optical axis is out of the plane of the layers and the layers are weakly attached. This work demonstrates that a bulk crystal with subtle periodic modulations in its structure—Sr 9/8 TiS 3 —is transparent and positive-uniaxial, with extraordinary index n e = 4.5 and ordinary index n o = 2.4 in the mid- to far-infrared. The excess Sr, compared to stoichiometric SrTiS 3 , results in the formation of TiS 6 trigonal-prismatic units that break the chains of face-sharing TiS 6 octahedra in SrTiS 3 into periodic blocks of five TiS 6 octahedral units. The additional electrons introduced by the excess Sr form highly oriented electron clouds, which selectively boost the extraordinary index n e and result in record birefringence (Δn > 2.1 with low loss). The connection between subtle structural modulations and large changes in refractive index suggests new categories of anisotropic materials and also tunable optical materials with large refractive-index modulation.

36 MATERIALS SCIENCE↗

First data and preliminary experimental results from a new Doppler backscattering system on the MAST-U spherical tokamak

Abstract A new Doppler backscattering (DBS) system, consisting of Q-band and V-band, has been installed and achieved its first data on the MAST-U spherical tokamak. The Q-band and V-band have separate microwave source systems, but share the same optical front-end components. The Q-band and V-band sources simultaneously generate eight (34, 36, 38, 40, 42, 44, 46 and 48 GHz) and seven (52.5, 55, 57.5, 60, 62.5, 65 and 67.5 GHz) fixed frequency probe beams, respectively. These frequencies provide a large range of radial positions from the low-field-side edge plasma to the core, and possibly to the high-field-side edge, depending on the plasma conditions. The quasi-optical system consists of a remotely-tunable polarizer, a focusing lens and a remotely-steerable mirror. By steering the mirror, the system provides remote control of the probed density fluctuation wavenumber, and allow the launch angle to match the magnetic field. The range of accessible turbulence wavenumbers (k θ ) is reasonably large with normalized wavenumberk θ ρ s ranging from <0.5 to 9. The first data acquired by this DBS system is validated by comparing with the data from the other DBS system on MAST-U (introduced in ref. [21]). An example of measuring the velocity profile spanning from the edge to the center in a high-density plasma is presented, indicating the robust capabilities of the integrated Q-band and V-band DBS systems.

Instruments & Instrumentation↗

X-ray instrumentation in astronomy; Proceedings of the Meeting, Cannes, France, December 2-4, 1985

Recent developments in X-ray and EUV astronomical instrumentation are discussed in reviews and reports. Topics examined include optical systems for the NASA Advanced X-ray Astrophysics Facility (AXAF), specialized X-ray systems, advanced X-ray optics, gas-filled X-ray detectors, instrumentation for spectrometry on AXAF, X-ray and EUV spectrometers, microchannel plate detectors, and solid-state detectors.

Culhane, J. L.↗

Effects of the contamination environment on surfaces and materials

In addition to the issues that have always existed, demands are being placed on space systems for increased contamination prevention/control. Optical surveillance sensors are required to detect low radiance targets. This increases the need for very low scatter surfaces in the optical system. Particulate contamination levels typically experienced in today's working environments/habits will most likely compromise these sensors. Contamination (molecular and particulate) can also affect the survivability of space sensors in both the natural and hostile space environments. The effects of di-octyl phthalate (DOP) on sensors are discussed.

Maag, Carl R.↗

Comparison of optics and electronics for the calculation of matrix-vector products

Optical processors are attractive because of their ability to perform massively parallel operations such as matrix vector products. The inherently analog nature of optical calculations requires that optical processors be based on analog computations. While the speed at which such analog operations can be performed as well as the natural parallelism of optical systems are great advantages of optical processors, the analog representation of values severely limits the achievable accuracy. Furthermore, optical processors are limited by the need to convert information to and from the intensity of light. Digitization can be used to increase the accuracy of optical matrix-vector processors, but causes a severe reduction in speed. This paper compares the throughput and power requirements of optical and electronic processors, showing that optical matrix-vector processors can provide a greater number of operations/Watt than conventional electronics.

Gary, C. K.↗

Imaging The Leading Edge Of A Weld

Proposed optical system integrated into plasma arc welding torch provides image of leading edge of weld pool and welding-arc-initiation point. Welding torch aligned better with joint. System includes coherent bundle of optical fibers and transparent cup.

Mcgee, William F.↗

Thermographic imaging for high-temperature composite materials: A defect detection study

The ability of a thermographic imaging technique for detecting flat-bottom hole defects of various diameters and depths was evaluated in four composite systems (two types of ceramic matrix composites, one metal matrix composite, and one polymer matrix composite) of interest as high-temperature structural materials. The holes ranged from 1 to 13 mm in diameter and 0.1 to 2.5 mm in depth in samples approximately 2-3 mm thick. The thermographic imaging system utilized a scanning mirror optical system and infrared (IR) focusing lens in conjunction with a mercury cadmium telluride infrared detector element to obtain high resolution infrared images. High intensity flash lamps located on the same side as the infrared camera were used to heat the samples. After heating, up to 30 images were sequentially acquired at 70-150 msec intervals. Limits of detectability based on depth and diameter of the flat-bottom holes were defined for each composite material. Ultrasonic and radiographic images of the samples were obtained and compared with the thermographic images.

Roth, Don J.↗

Fabrication and Testing of a Large Primary Reflector Structure

This paper discusses the fabrication considerations and proposed testing concepts related to a large twelve meter, graphite-epoxy space truss that is being developed to provide support of the primary mirror system for the Beam Transmission Optical System (BTOS).

space truss primary reflector free electron laser ↗

Photonic processing at NASA Ames Research Center

The Photonic Processing group is engaged in applied research on optical processors in support of the Ames vision to lead the development of autonomous intelligent systems. Optical processors, in conjunction with numeric and symbolic processors, are needed to provide the powerful processing capability that is required for many future agency missions. The research program emphasizes application of analog optical processing, where free-space propagation between components allows natural implementations of algorithms requiring a large degree of parallel computation. Special consideration is given in the Ames program to the integration of optical processors into larger, heterogeneous computational systems. Demonstration of the effective integration of optical processors within a broader knowledge-based system is essential to evaluate their potential for dependable operation in an autonomous environment such as space. The Ames Photonics program is currently addressing several areas of interest. One of the efforts is to develop an optical correlator system with two programmable spatial light modulators (SLMs) to perform distortion invariant pattern recognition. Another area of research is optical neural networks, also for use in distortion-invariant pattern recognition.

Ochoa, Ellen↗

Nonlocal Coherent Optical Nonlinearities of a Macroscopic Quantum System

The optical responses of solids are typically understood to be local in space. Whether locality holds for the optical response of a macroscopic quantum system has, however, been largely unexplored. Here, we use multidimensional coherent spectroscopy at the optical diffraction limit to demonstrate nonlocal optical nonlinearities in a semiconductor microcavity. In conclusion, these nonlocal optical responses are both coherent and quantum in nature, deriving from the macroscopic length scale of confined exciton-polariton wave functions.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗