Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Noise characterization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 883 records · Page 49

Model-based reconstruction for enhanced x-ray CT of dense tri-structural isotropic particles

Tri-structural isotropic (TRISO) fuel particles are a key component of next generation nuclear fuels. Using x-ray computed tomography (CT) to characterize TRISO particles is challenging because of the strong attenuation of the x-ray beam by the uranium core, leading to severe photon starvation in a substantial fraction of the measurements. Furthermore, the overall acquisition time for a high-resolution CT scan can be very long when using conventional laboratory-based x-ray systems and reconstruction algorithms. Specifically, when analytic methods such as the Feldkamp–Davis–Kress (FDK) algorithm are used for reconstruction, it results in severe streak artifacts and noise in the corresponding 3D volume, which makes subsequent analysis of the particles challenging. In this paper, we develop and apply model-based image reconstruction (MBIR) algorithms to improve the quality of CT reconstructions for TRISO particles to facilitate better characterization. We demonstrate that the proposed MBIR algorithms can significantly suppress artifacts with minimal pre-processing compared to conventional approaches. We also demonstrate that the proposed MBIR approach can obtain high-quality reconstruction compared to the FDK approach even when using a fraction of the typically acquired measurements, thereby enabling dramatically faster measurement times for TRISO particles.

Venkatakrishnan, Singanallur↗

Multipolarization SAR data for surface feature delineation and forest vegetation characterization

This paper presents the utility of multipolarization Synthetic Aperture Radar (SAR) data for surface feature delineation and forest vegetation characterization. Three channels of radioed data (VV/HH, VH/HH, and VH/VV) are generated from the HH, VV, and VH polarization data (V = vertical, H = horizontal). The radioed data are linearly stretched to yield a digital number within a range of 0 to 255. The techniques for reducing SAR speckle noise and for measuring the degree of separation are discussed. For surface feature delineation, the results indicate that cross polarization as well as cross polarization radioed data better delineate those surface features that are difficult to separate by like polarization data. The results suggest using a median value filtering technique to reduce within-plot data fluctuation to increase the separability measure. For forest vegetation characterization, the results indicate that multipolarization SAR data may be used to estimate forest properties such as total-tree biomass, basal area, and tree height.

Wu, Shih-Tseng↗

Fundamental Noise-Limited Optical Phase Locking at Femtowatt Light Levels

We describe an optical phase lock loop (PLL) designed to recover an optical carrier at powers below one picowatt in a Deep Space optical transponder. Previous low power optical phase lock has been reported with powers down to about 1 pW. We report the demonstration and characterization of the optical phase locking at femtowatt levels. We achieved a phase slip rate below one cycle-slip/second at powers down to 60 femtowatts. This phase slip rate corresponds to a frequency stability of 1 10(exp -14) at 1 s, a value better than any frequency standard available today for measuring times equal to a typical two-way delay between Earth and Mars. The PLL shows very robust stability at these power levels. We developed simulation software to optimize parameters of the second order PLL loop in the presence of laser flicker frequency noise and white phase (photon) noise, and verified the software with a white phase noise model by Viterbi. We also demonstrated precise Doppler tracking at femtowatt levels.

Doppler ranging↗

Characterization of damage processes in Montney siltstone under triaxial compression using acoustic emission and diagnostic imaging

SUMMARY Crack nucleation and rock failure processes in a fine-grained siltstone (Montney Formation) under triaxial compression are investigated using combined diagnostic techniques, including ultrasonic-wave measurement, acoustic-emission (AE) monitoring, computed tomography (CT) scanning, and thin-section imaging. The sample displays a weak-to-moderate inherent seismic anisotropy and noticeable stress-induced anisotropy prior to failure. No AE event was detected until the applied axial stress reached 95 per cent of the peak value. The signal-to-noise ratio is relatively low, however, and detectable AE events are more diffuse than those observed in highly brittle rocks. The AE locations correlate with a shear fracture zone imaged by CT scanning. AE moment-tensor analysis reveals that events with larger relative magnitudes are characterized by high volumetric (tensile or compressive) components, and the initiation of the failure zone is dominated by combined shear-tensile (ST) failure. Stress inversion of the AE events with high tensile components is in good agreement with the known applied stress. Microscopic imaging of thin sections from the failed sample shows that the failure zone is an en echelon structure consisting of a major fracture with branching micro and minor cracks. This failure mechanism is consistent with a ST source mechanism and is interpreted to be associated with the fine granular structure and mineral composition of Montney siltstone.

Jia, Suzie Q. (ORCID:0000000326496190)↗

Transport coefficient approach for characterizing nonequilibrium dynamics in soft matter

Nonequilibrium states in soft condensed matter require a systematic approach to characterize and model materials, enhancing predictability and applications. Among the tools, X-ray photon correlation spectroscopy (XPCS) provides exceptional temporal and spatial resolution to extract dynamic insight into the properties of the material. However, existing models might overlook intricate details. We introduce an approach for extracting the transport coefficient, denoted as $J(t)$, from the XPCS studies. This coefficient is a fundamental parameter in nonequilibrium statistical mechanics and is crucial for characterizing transport processes within a system. Our method unifies the Green–Kubo formulas associated with various transport coefficients, including gradient flows, particle–particle interactions, friction matrices, and continuous noise. We achieve this by integrating the collective influence of random and systematic forces acting on the particles within the framework of a Markov chain. We initially validated this method using molecular dynamics simulations of a system subjected to changes in temperatures over time. Subsequently, we conducted further verification using experimental systems reported in the literature and known for their complex nonequilibrium characteristics. The results, including the derived $J(t)$ and other relevant physical parameters, align with the previous observations and reveal detailed dynamical information in nonequilibrium states. This approach represents an advancement in XPCS analysis, addressing the growing demand to extract intricate nonequilibrium dynamics. Further, the methods presented are agnostic to the nature of the material system and can be potentially expanded to hard condensed matter systems.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

High‐speed 4‐dimensional scanning transmission electron microscopy using compressive sensing techniques

Abstract Here we show that compressive sensing allows 4‐dimensional (4‐D) STEM data to be obtained and accurately reconstructed with both high‐speed and reduced electron fluence. The methodology needed to achieve these results compared to conventional 4‐D approaches requires only that a random subset of probe locations is acquired from the typical regular scanning grid, which immediately generates both higher speed and the lower fluence experimentally. We also consider downsampling of the detector, showing that oversampling is inherent within convergent beam electron diffraction (CBED) patterns and that detector downsampling does not reduce precision but allows faster experimental data acquisition. Analysis of an experimental atomic resolution yttrium silicide dataset shows that it is possible to recover over 25 dB peak signal‐to‐noise ratio in the recovered phase using 0.3% of the total data. Lay abstract : Four‐dimensional scanning transmission electron microscopy (4‐D STEM) is a powerful technique for characterizing complex nanoscale structures. In this method, a convergent beam electron diffraction pattern (CBED) is acquired at each probe location during the scan of the sample. This means that a 2‐dimensional signal is acquired at each 2‐D probe location, equating to a 4‐D dataset. Despite the recent development of fast direct electron detectors, some capable of 100kHz frame rates, the limiting factor for 4‐D STEM is acquisition times in the majority of cases, where cameras will typically operate on the order of 2kHz. This means that a raster scan containing 256^2 probe locations can take on the order of 30s, approximately 100‐1000 times longer than a conventional STEM imaging technique using monolithic radial detectors. As a result, 4‐D STEM acquisitions can be subject to adverse effects such as drift, beam damage, and sample contamination. Recent advances in computational imaging techniques for STEM have allowed for faster acquisition speeds by way of acquiring only a random subset of probe locations from the field of view. By doing this, the acquisition time is significantly reduced, in some cases by a factor of 10‐100 times. The acquired data is then processed to fill‐in or inpaint the missing data, taking advantage of the inherently low‐complex signals which can be linearly combined to recover the information. In this work, similar methods are demonstrated for the acquisition of 4‐D STEM data, where only a random subset of CBED patterns are acquired over the raster scan. We simulate the compressive sensing acquisition method for 4‐D STEM and present our findings for a variety of analysis techniques such as ptychography and differential phase contrast. Our results show that acquisition times can be significantly reduced on the order of 100‐300 times, therefore improving existing frame rates, as well as further reducing the electron fluence beyond just using a faster camera.

Robinson, Alex W.↗

Conditional quantum plasmonic sensing

The possibility of using weak optical signals to perform sensing of delicate samples constitutes one of the main goals of quantum photonic sensing. Furthermore, the nanoscale confinement of electromagnetic near fields in photonic platforms through surface plasmon polaritons has motivated the development of highly sensitive quantum plasmonic sensors. Despite the enormous potential of plasmonic platforms for sensing, this class of sensors is ultimately limited by the quantum statistical fluctuations of surface plasmons. Indeed, the fluctuations of the electromagnetic field severely limit the performance of quantum plasmonic sensing platforms in which delicate samples are characterized using weak near-field signals. Furthermore, the inherent losses associated with plasmonic fields levy additional constraints that challenge the realization of sensitivities beyond the shot-noise limit. Here, we introduce a protocol for quantum plasmonic sensing based on the conditional detection of plasmons. We demonstrate that the conditional detection of plasmonic fields, via plasmon subtraction, provides a new degree of freedom to control quantum fluctuations of plasmonic fields. This mechanism enables improvement of the signal-to-noise ratio of photonic sensors relying on plasmonic signals that are comparable to their associated field fluctuations. Consequently, the possibility of using weak plasmonic signals to sense delicate samples, while preserving the sample properties, has important implications for molecule sensing, and chemical detection.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

STILGAR: Subsurface Models for Graymont Pleasant Gap Mine

The detection, location, and monitoring of underground structures are of great importance to national and global security. Tunnels and voids generate seismic signatures detectable at the surface, but using non-invasive seismic data to image near-surface presents several challenges in real-world applications. In this report, we describe the use of a dense surface seismic deployment to generate subsurface models of the Graymont Pleasant Gap mine - a single-layer mine with a complex structure embedded in a high-velocity P-wave limestone bedrock. Our approach consists of three key methods. We use P-wave arrival times from local blast events to perform a tomography inversion with the tomoTD method, constructing a P-wave velocity model of the subsurface. We model the layer above the mine using Rayleigh wave ellipticity and inversion techniques. We leverage ongoing anthropogenic activities to identify and locate noise sources both on the surface and within the subsurface. With this integrated approach we aim to overcome the challenges and enhance our ability to non-invasively characterize underground structures, contributing to improved seismic monitoring techniques.

58 GEOSCIENCES↗

Contrast and Temperature Dependence of Multi-epoch High-resolution Cross-correlation Exoplanet Spectroscopy

While high-resolution cross-correlation spectroscopy (HRCCS) techniques have proven effective at characterizing the atmospheres of transiting and nontransiting hot Jupiters, the limitations of these techniques are not well understood. We present a series of simulations of one HRCCS technique, which combines the cross-correlation functions from multiple epochs, to place temperature and contrast limits on the accessible exoplanet population for the first time. We find that planets approximately Saturn-sized and larger within ∼0.2 au of a Sun-like star are likely to be detectable with current instrumentation in the L band, a significant expansion compared with the previously studied population. Cooler (T {sub eq} ≤ 1000 K) exoplanets are more detectable than suggested by their photometric contrast alone as a result of chemical changes that increase spectroscopic contrast. The L-band CH{sub 4} spectrum of cooler exoplanets enables robust constraints on the atmospheric C/O ratio at T {sub eq} ∼ 900 K, which have proven difficult to obtain for hot Jupiters. These results suggest that the multi-epoch approach to HRCCS can detect and characterize exoplanet atmospheres throughout the inner regions of Sun-like systems with existing high-resolution spectrographs. We find that many epochs of modest signal-to-noise ratio (S/N{sub epoch} ∼ 1500) yield the clearest detections and constraints on C/O, emphasizing the need for high-precision near-infrared telluric correction with short integration times.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Baysian recursive image estimation.

Discussion of a statistical procedure for treatment of noise-affected images to recover unaffected images by recursive processing with noise background elimination. The feasibility of the application of a recursive linear Kalman filtering technique to image processing is demonstrated. The procedure is applicable to images which are characterized statistically by mean and correlation functions. A time invariant dynamic model is proposed to provide stationary statistics for the scanner output.

Nahi, N. E.↗

Digital data detection and synchronization

The primary accomplishments have been in the analysis and simulation of receivers and bit synchronizers. It has been discovered that tracking rate effects play, a rather fundamental role in both receiver and synchronizer performance, but that data relating to recorder time-base-error, for the proper characterization of this phenomenon, is in rather short supply. It is possible to obtain operationally useful tape recorder time-base-error data from high signal-to-noise ratio tapes using synchronizers with relatively wideband tracking loops. Low signal-to-noise ratio tapes examined in the same way would not be synchronizable. Additional areas of interest covered are receiver false lock, cycle slipping, and other unusual phenomena, which have been described to some extent in this and earlier reports and simulated during the study.

Noack, T. L.↗

LaF3 infrared detector

A class of infrared detectors is proposed, and experimental results are presented for a prototype device. The material used is LaF3, an ionic conductor with a capacitance that varies exponentially with temperature. The detectivity of a prototype detector is estimated from measured signal voltages and incident power, and a Johnson noise voltage is calculated from the measured resistance. At a modulation frequency of 20 Hz, the estimated detectivity is about 2 million cm/sq root Hz/W. For the parameters characterizing this device, the estimated detectivity is consistent with a theoretical prediction. The theory further predicts an optimum detectivity of about 1 billion cm/sq root Hz/W for much thinner devices than the prototypes.

Sher, A.↗

Calibration and evaluation of AVIRIS data: Cripple Creek in October 1987

Airborne Visible/Infrared Imaging Spectrometer (AVIRIS) data were obtained over Cripple Creek and Canon City Colorado on October 19, 1987 at local noon. Multiple ground calibration sites were measured within both areas with a field spectrometer and samples were returned to the laboratory for more detailed spectral characterization. The data were used to calibrate the AVIRIS data to ground reflectance. Once calibrated, selected spectra in the image were extracted and examined, and the signal to noise performance was computed. Images of band depth selected to be diagnostic of the presence of certain minerals and vegetation were computed. The AVIRIS data were extremely noisy, but images showing the presence of goethite, kaolinite and lodgepole pine trees agree with ground checks of the area.

Clark, Roger N.↗

Recent Development of Sb-based Phototransistors in the 0.9- to 2.2-microns Wavelength Range for Applications to Laser Remote Sensing

We have investigated commercially available photodiodes and also recent developed Sb-based phototransistors in order to compare their performances for applications to laser remote sensing. A custom-designed phototransistor in the 0.9- to 2.2-microns wavelength range has been developed at AstroPower and characterized at NASA Langley's Detector Characterization Laboratory. The phototransistor's performance greatly exceeds the previously reported results at this wavelength range in the literature. The detector testing included spectral response, dark current and noise measurements. Spectral response measurements were carried out to determine the responsivity at 2-microns wavelength at different bias voltages with fixed temperature; and different temperatures with fixed bias voltage. Current versus voltage characteristics were also recorded at different temperatures. Results show high responsivity of 2650 A/W corresponding to an internal gain of three orders of magnitude, and high detectivity (D*) of 3.9x10(exp 11) cm.Hz(exp 1/2)/W that is equivalent to a noise-equivalent-power of 4.6x10(exp -14) W/Hz(exp 1/2) (-4.0 V @ -20 C) with a light collecting area diameter of 200-microns. It appears that this recently developed 2-micron phototransistor's performances such as responsivity, detectivity, and gain are improved significantly as compared to the previously published APD and SAM APD using similar materials. These detectors are considered as phototransistors based-on their structures and performance characteristics and may have great potential for high sensitivity differential absorption lidar (DIAL) measurements of carbon dioxide and water vapor at 2.05-microns and 1.9-microns, respectively.

Abedin, M. Nurul↗

Improved Detection System Description and New Method for Accurate Calibration of Micro-Channel Plate Based Instruments and Its Use in the Fast Plasma Investigation on NASA's Magnetospheric MultiScale Mission

The Fast Plasma Investigation (FPI) on NASAs Magnetospheric MultiScale (MMS) mission employs 16 Dual Electron Spectrometers (DESs) and 16 Dual Ion Spectrometers (DISs) with 4 of each type on each of 4 spacecraft to enable fast (30 ms for electrons; 150 ms for ions) and spatially differentiated measurements of the full 3D particle velocity distributions. This approach presents a new and challenging aspect to the calibration and operation of these instruments on ground and in flight. The response uniformity, the reliability of their calibration and the approach to handling any temporal evolution of these calibrated characteristics all assume enhanced importance in this application, where we attempt to understand the meaning of particle distributions within the ion and electron diffusion regions of magnetically reconnecting plasmas. Traditionally, the micro-channel plate (MCP) based detection systems for electrostatic particle spectrometers have been calibrated using the plateau curve technique. In this, a fixed detection threshold is set. The detection system count rate is then measured as a function of MCP voltage to determine the MCP voltage that ensures the count rate has reached a constant value independent of further variation in the MCP voltage. This is achieved when most of the MCP pulse height distribution (PHD) is located at higher values (larger pulses) than the detection system discrimination threshold. This method is adequate in single-channel detection systems and in multi-channel detection systems with very low crosstalk between channels. However, in dense multi-channel systems, it can be inadequate. Furthermore, it fails to fully describe the behavior of the detection system and individually characterize each of its fundamental parameters. To improve this situation, we have developed a detailed phenomenological description of the detection system, its behavior and its signal, crosstalk and noise sources. Based on this, we have devised a new detection system calibration method that enables accurate and repeatable measurement and calibration of MCP gain, MCP efficiency, signal loss due to variation in gain and efficiency, crosstalk from effects both above and below the MCP, noise margin, and stability margin in one single measurement. More precise calibration is highly desirable as the instruments will produce higher quality raw data that will require less post-acquisition data correction using results from in-flight pitch angle distribution measurements and ground calibration measurements. The detection system description and the fundamental concepts of this new calibration method, named threshold scan, will be presented. It will be shown how to derive all the individual detection system parameters and how to choose the optimum detection system operating point. This new method has been successfully applied to achieve a highly accurate calibration of the DESs and DISs of the MMS mission. The practical application of the method will be presented together with the achieved calibration results and their significance. Finally, it will be shown that, with further detailed modeling, this method can be extended for use in flight to achieve and maintain a highly accurate detection system calibration across a large number of instruments during the mission.

detection system↗

Laboratory characterization of silicon avalanche photodiodes (APD) for pulse position modulation (PPM) detection

Two commercially available large area silicon avalanche photodiodes (APD) were characterized in the laboratory. Specifically, the response of the APD’s to a sequence of 8-bit pulse position modulated (256-PPM) laser pulses, with and without background noise, was recorded and stored for post analysis. Empirical probability distribution functions (pdf) were constructed from the signal and noise slot data and compared to pdf’s predicted by an analytical model based on Webb/Gaussian statistics. The limited pulse sequence was also used to generate bit-error rate (BER) versus signal photons per pulse values, albeit with large error bars. These BER measurements were also compared to results predicted using the Gaussian and Webb/Gaussian models for APD channel statistics. While the measurements qualitatively reflect features predicted by theory, significant quantitative deviations are displayed between the measurements and theory. The source of these discrepancies is not currently well understood, but it is surmised that inaccurate knowledge of detector parameters such as gain and noise equivalent temperature models may explain the discrepancies.

Biswas, A.↗

Acoustic Characterization of the NASA Langley 14- by 22-Foot Subsonic Tunnel using a Phased Array

A characterization test was conducted in the NASA Langley Research Center 14- by 22-Foot Subsonic Tunnel to assess recent acoustic modifications in the facility. Test section reflectivity, background noise and shear layer effects were evaluated by taking measurements of known noise sources. Both conventional speakers and a high-pressure air source were employed as noise generation mechanisms. These were mounted to a pole or fairing at a consistent location in the test section. The source waveforms were used to represent the expected frequency content of scaled Urban Air Mobility vehicles. Acoustic measurements were taken using two unique microphone arrays placed outside the core flow, one of which was a 54-element streamwise-traversing phased array. The other was an 11-element linear tower array. The applicability of phased array acoustic beamforming techniques to mitigate shear layer effects and reject background noise is presented. Additionally, beamforming results are compared to results from single-microphone processing techniques. Flow speeds investigated ranged from Mach 0.00 (static) to Mach 0.12. The tunnel has been partially acoustically treated but still exhibits flow noise, reducing the signal-to-noise ratio of the source under investigation. Conventional beamforming was able to capture high frequency content passing through the shear layer better than single microphone measurements. CLEAN deconvolution improves source mapping at low frequencies.

phased array↗

Fundamental Parameters of ∼30,000 M dwarfs in LAMOST DR1 Using Data-driven Spectral Modeling

M dwarfs are the most common type of star in the Galaxy, and because of their small size are favored targets for searches of Earth-sized transiting exoplanets. Current and upcoming all-sky spectroscopic surveys, such as the Large Sky Area Multi Fiber Spectroscopic Telescope (LAMOST), offer an opportunity to systematically determine physical properties of many more M dwarfs than has been previously possible. Here, we present new effective temperatures, radii, masses, and luminosities for 29,678 M dwarfs with spectral types M0–M6 in the first data release (DR1) of LAMOST. We derived these parameters from the supervised machine-learning code, The Cannon, trained with 1388 M dwarfs in the Transiting Exoplanet Survey Satellite Cool Dwarf Catalog that were also present in LAMOST with high signal-to-noise ratio (>250) spectra. Our validation tests show that the output parameter uncertainties are strongly correlated with the signal-to-noise of the LAMOST spectra, and we achieve typical uncertainties of 110 K in T{sub eff} (∼3%), 0.065 R{sub ⊙} (∼14%) in radius, 0.054 M{sub ⊙} (∼12%) in mass, and 0.012 L{sub ⊙} (∼20%) in luminosity. The model presented here can be rapidly applied to future LAMOST data releases, significantly extending the samples of well-characterized M dwarfs across the sky using new and exclusively data-based modeling methods.

79 ASTRONOMY AND ASTROPHYSICS↗