Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Neutron detector”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 883 records · Page 49

Simultaneous measurement of organic scintillator response to carbon and proton recoils

Organic scintillators are widely used for neutron detection in both basic nuclear physics and applications. While the proton light yield of organic scintillators has been extensively studied, measurements of the light yield from neutron interactions with carbon nuclei are scarce. Demonstrate a new approach for the simultaneous measurement of the proton and carbon light yield of organic scintillators. Provide new carbon light yield data for the EJ-309 liquid and EJ-204 plastic organic scintillators. A 33-MeV 2 H + beam from the 88-Inch Cyclotron at Lawrence Berkeley National Laboratory was impinged upon a 3-mm-thick Be target to produce a high-flux, broad-spectrum neutron beam. The double time-of-flight technique was extended to simultaneously measure the proton and carbon light yields of the organic scintillators, wherein the light output associated with the recoil particle was determined using np and nC elastic scattering kinematics. The proton and carbon light yield relations of the EJ-309 liquid and EJ-204 plastic organic scintillators were measured over a recoil energy range of approximately 0.3 to 1 MeV and 2 to 5 MeV, respectively, for EJ-309, and 0.2 to 0.5 MeV and 1 to 4 MeV, respectively, for EJ-204. Furthermore, these data provide new insight into the ionization quenching effect in organic scintillators and key input for simulation of the response of organic scintillators for both basic science and a broad range of applications.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Status of the ANNIE experiment

The Accelerator Neutrino Neutron Interaction Experiment (ANNIE) is a Gadolinium-loaded water Cherenkov detector located in the Booster Neutrino Beam at Fermilab. One of its primary physics goals is to measure the final state neutron multiplicity of neutrino-nucleus interactions. This measurement of the neutron yield as a function of the outgoing lepton kinematics will be useful to constrain systematic uncertainties and reduce biases in future long-baseline oscillation and cross-section experiments. ANNIE is also a testbed for innovative new detection technologies. It will make use of pioneering photodetectors called Large Area Picosecond Photodetectors (LAPPDs) with better than 100 picosecond time resolution, which will enhance its reconstruction capabilities and demonstrate the feasibility of this technology as a new tool in high energy physics. The status of the experiment is reported here in terms of the overall progress, the deployment of the first LAPPD and an overview of recently taken beam and calibration data. Additional future R\&D efforts and analysis opportunities involving the use of the novel detection medium of Water-based Liquid Scintillators (WbLS) are also briefly highlighted.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Total fusion yield measurements using deuterium–tritium gamma rays

The deuterium–tritium (DT) fusion reaction, D ( T , γ ) 5 He , has a rare (4.2 × 10 – 5 ) branching ratio that releases a ~16 MeV gamma ray instead of the more common 14.1 MeV fusion neutron. These fusion gamma rays can be used as a complementary source of measuring the net fusion yield of experiments. Fusion gamma rays have the advantage of having negligible Doppler broadening, being isotropic and less down-scattered compared to fusion neutrons. At the National Ignition Facility, we measured the DT fusion gamma rays by the Gamma Reaction History diagnostic that thresholds to only measure >10 MeV gamma rays. After removing a ~12% contribution from neutron capture interactions in deuterium, D ( n , γ ) T , and carbon, 12 C ( n , γ ) 13 C , the deviation between GRH measurements and neutron-based yield measurements has been reduced to 10%. Further improvements are needed for detailed physics comparison.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Livermore tomography tools: Accurate, fast, and flexible software for tomographic science

Livermore Tomography Tools (LTT) is a customizable scientific software package that enables a broad range of research and development efforts into computed tomography (CT). Here, it was developed to process x-ray and neutron CT data accurately and rapidly from raw detector counts to reconstructed volumes with the flexibility to handle many special cases. LTT fulfills long-term CT software goals to provide quantitatively accurate results reported in physical units (e.g., mm -1 or cm -1 ) while exploiting all available computational advantages to maximize speed. Written in C/C++ with support for multiple CPUs and GPUs, LTT runs on many computing platforms (Linux/Unix, Windows, and Mac; laptops to supercomputers). As a result, LTT can:process data acquired from various custom-built and commercially available CT scanners, model and simulate x-ray and neutron interactions to encourage algorithm prototyping, and allow for rapid insertion of the latest algorithms.We describe LTT’s software architecture, user interfaces, and its 88 algorithms (as of this writing) for pre-processing, reconstruction, post-processing, and simulation that support many scanner geometries (parallel-, fan-, cone-beam, and custom). Several applications are presented that illustrate LTT’s accuracy, speed, and flexibility relative to other solutions.

36 MATERIALS SCIENCE↗

Nuclear activation analysis of zirconium-90 isomeric and ground-state reactions at the OMEGA Laser Facility

Nuclear activation is a well-established technique for inferring neutron yields in laser direct-drive deuterium–tritium (DT) and deuterium–deuterium (D 2 ) implosions at the OMEGA Laser Facility. Zirconium has long been considered an excellent candidate for measuring DT neutron fusion yields by observing decays of the 90 Zr(n,2n) 89 Zr ground-state reaction. As it has a higher energy threshold than present activation detectors utilizing copper, zirconium provides a means to infer primary neutron yields that are less susceptible to being skewed due to neutron scattering within the experimental environment. However, with a 78.41-h half-life, it is not operationally practical to utilize this reaction for OMEGA experiments, which have a 1-h shot cycle. Zirconium’s 90 Zr(n,2n) 89 mZr reaction presents itself as a viable candidate to infer neutron yields within a shot cycle, given its half-life of 4.16 min. Here, we present an overview of the approach and methodology, utilizing first principles techniques, to infer the primary neutron yields from OMEGA DT fusion experiments by using both the isomeric and the ground-state reaction. Yields inferred from both reactions are compared, which are in good agreement between the two.

Activation analysis↗

Neutrinos from neutron stars

A calculation of the flux of ultra-high energy neutrinos from galactic neutron stars is presented. The calculation is used to determine the number of point sources detectable at the sensitivity threshold of a proposed deep underwater muon and neutrino detector array. The detector array would have a point source detection threshold of about 100 eV/sq cm-sec. Analysis of neutrino luminosities and the number of detectable sources suggests that the deep underwater detector may make a few discoveries. In particular, a suspected neutron star in the Cyg X-3 source seems a promising target for the deep underwater array.

Helfand, D. J.↗

Development of a compact fast-neutron spectrometer for nuclear emergency response applications

We have developed a Compact Fast Neutron Spectrometer (CFNS) for passive assay of special nuclear material (SNM) through the observation of fast neutrons. The CFNS consists of eight organic glass scintillators (OGS) coupled to silicon photomultipliers and a waveform digitizer, which are integrated within a human-portable box. The CFNS determines the neutron energy profile by spectrum unfolding using the Maximum-Likelihood Expectation Maximization method. The detector acquisition system was optimized to have a dynamic range of up to 10 MeV neutron energy. Bulk special nuclear material (SNM) measurements from the National Criticality Experiments Research Center were analyzed for SNM validation/examination. Additionally, the results show that the CFNS can be used to distinguish between fission and (α, n) neutron emitters, regardless of intervening material type (Cu and polyethylene) and thickness, by taking the ratio of neutron counts at different regions in the unfolded energy spectrum. Additionally, by fitting an exponential curve to the unfolded energy spectrum of PuO 2 and Pu neutron emitters, the CFNS showed the ability of distinguishing between pure Pu oxide, pure Pu metal and mixed oxide-metal configurations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Field Test Report Neutron Scintillator Array Dry Storage Cask Scanner FY2024

During two weeks of Field Testing at the Idaho National Laboratory INTEC Cask Farm in July and August 2024, the LLNL Dry Storage Cask Scanner Array was lifted on top of an MC-10 dry storage fuel cask and operated to acquire neutron and gamma-ray data from the 24 fuel bundle positions. Neutron and gamma-ray data acquisition scans across the top of the cask of varying dwell times were performed July 15-18, 2024 and August 19-22, 2024 to evaluate the ability of the scanner data to reveal asymmetries in the fuel positions that reflect asymmetries in the MC-10 cask fuel bundle loading. The MC-10 cask 24 position fuel bundle loading at the INTEC Cask Farm is well documented, including the locations of six empty fuel bundle positions. This loading presents an opportunity to test the ability of the scanner system to detect diversion of spent fuel bundles as well as to validate the MC-10 cask MCNP modeling. The cask scanner array consists of six Stilbene crystal scintillator detectors and a linear actuator frame that moves the six detectors across the MC-10 dry storage cask to obtain data above each of the 24 fuel bundle positions. The detectors are connected to a pulse-shape discrimination data acquisition system capable of generating separate neutron and gamma-ray spectra for each detector and for each scan position. From the prior single detector Field Test in 2021 and iteration with MCNP modeling, the neutron and gamma-ray data were analyzed in multiple energy regions to identify an analysis method that would provide the strongest and most consistent signature of the asymmetric MC-10 cask fuel loading1 . From both the 2021 Field Test and the current Field Test results, the neutron capture gamma-ray count rate around 2.2 MeV provides the strongest signature of the asymmetric MC-10 cask fuel loading and has qualitative agreement with MCNP calculations. Counting all gamma-rays produces a similar signature. Neutrons emerging from the cask top are moderated and captured by the hydrogen in the polyethylene moderator and scintillator detector, producing a 2.2 MeV gamma ray which is seen in the scintillator gamma-ray spectrum. The count rate in the 2.2 MeV gamma-ray region is ~50 c/s, which is ~1000x higher than the ~0.05 n/s rate in the > 4MeV neutron region, and ~50x greater than the ~1 n/s rate in the neutrons > 500 keV region. Analysis of the 2.2 MeV neutron-capture Compton-scattered gamma-rays produces a statistically significant signature of the INTEC Cask Farm MC-10 asymmetric fuel loading. MCNP simulations indicate that the average neutron energy spectrum offers the potential to detect a large asymmetry from several missing bundles as well as individual missing fuel bundles. Testing this feature will require measurements on a cask with single missing elements.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Anisotropy in Thermal Conductivity of Ga2O3 under Irradiation: Ab-initio Investigations

Ga2O3 is a wide-bandgap semiconducting material known for its high breakdown electric field and thermal stability. Its various crystalline forms have shown great potential in power electronics, optoelectronics, and high-temperature applications. Specifically, ß-Ga2O3 has been recognized for its suitability in neutron and gamma radiation detection, making it ideal for sensor and detector applications [1]. Notably, ß-Ga2O3 exhibits anisotropic thermal conductivity, meaning that the magnitude of thermal conductivity varies with the crystallographic direction [2]. Under neutron irradiation, Ga2O3 undergoes a significant phenomenon, resulting in the formation of Helium bubbles within its crystalline matrix. The presence of Helium in Ga2O3 has been found to influence the material's anisotropic thermal conductivity. In this study, the objectives were twofold: firstly, to employ Density Functional Theory (DFT) to determine the most probable sites of Helium occupation in ß-Ga2O3, and secondly, to investigate the anisotropic variation in thermal conductivity when Helium is present in the crystalline matrix of ß-Ga2O3. These ab-initio DFT studies provide crucial insights into understanding the behavior of Helium in Ga2O3 and its impact on thermal conductivity, which can contribute to further advancements in sensor and detector applications based on this wide-bandgap semiconductor.

36 MATERIALS SCIENCE↗

Comparison of Approach-to-Critical Results in Current and Pulse Mode for Systems with High Starter Neutron Rates

Reactors and critical assemblies use a variety of detection systems to monitor the neutron population. The count rate is proportional to the neutron flux present at the location of the detector. When such systems are placed external to an assembly, it is often assumed that the relative leakage multiplication will be proportional to the detector count rate (assuming that the source term, system geometry, and detector placement have not changed). Such systems are often used in an approach-to-critical during reactor startup to ensure that the critical configuration is well predicted. Various types of detectors have been used during an approach-to-critical. These include 3 He, BF 3 , ion chambers, fission chambers, and fission foils. Any of these types of systems (or others) should work well when adequate counting statistics are available. These detector systems can be operated in either pulse or current mode. The National Criticality Experiments Research Center (NCERC) has two detection systems that are commonly used in critical assembly operations. The start-up (referred to as "SU" in this work) system is made up of 3 He proportional counters in pulse mode and the linear counter system (referred to as "LC" in this work) consists of compensated ion-chambers in current mode. Typically the SU system is used for approach-to-critical operations and the LC system is only used at/above delayed critical ( k eff = 1). This work investigates the use of the LC system for an approach-to-critical. It has been long hypothesized that such an approach would be feasible for systems with high starter neutron rates.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Studying MeV Scale Neutron Interactions in DUNE ND-LAr 2x2 Demonstrator

The Deep Underground Neutrino Experiment (DUNE) is a long-baseline neutrino oscillation experiment designed to make high-precision measurements of neutrino oscillation parameters and probe for new physics using a neutrino beam produced at Fermilab and measured at a near detector complex and a far detector located 1,300 km away at the Sanford Underground Research Facility. Precise neutrino energy reconstruction is essential for these measurements, with neutron production in neutrino–argon interactions representing a significant source of systematic uncertainty, as neutrons can carry away significant energy, making their detection and characterization crucial. DUNE’s near detector complex includes ND-LAr, a Liquid Argon Time Projection Chamber (LArTPC) detector designed to mirror the far detector technology and constrain neutrino–argon interaction systematics. The DUNE 2x2 Demonstrator, a pixelated LArTPC based on the ArgonCube design, serves as a prototype for ND-LAr. During 2x2 operations from October to November 2026, an Americium–Beryllium (AmBe) neutron source was deployed near the detector cryostat to obtain a high-statistics sample of neutron interactions. This poster presents progress in studying MeV-scale neutron interactions in this dataset by identifying de-excitation gammas from neutron capture on argon, providing a method for neutron identification and charge readout system calibration in future DUNE detectors.

Mao, Edgar [Syracuse U.] (ORCID:0009000600893306)↗

Many-body Nuclear Dynamics

The principal goal of this work was to better understand the fusion of neutron-rich nuclei a topic relevant to the fields of both nuclear physics and nuclear astrophysics. The work provides insight into the structure and reactions of neutron-rich nuclei namely the extent of their neutron density distribution and its polarizability. By comparing the fusion excitation functions for a chain of isotopes with a common target nucleus changes in the attractive nuclear potential are assessed. This change in the attractive potential is related to changes in the neutron density distribution with increasing number of neutrons or changes in fusion dynamics with increasing neutron number. The impact of the pairing of valence neutrons and protons on the fusion cross-section is also examined. Measurement of an isotopic chain is a powerful tool to address this topic. The experimental program made use of several different accelerator facilities. The core of the experimental work involved experiments at the ReA3 accelerator and the Facility for Rare Isotope Beams (FRIB) situated at Michigan State University, at GANIL, the French national nuclear physics laboratory, and the University of Notre Dame. At ReA3 the degree to which α-clusters associated with fusion of 28,30,32 Si + 28 Si result from the collision dynamics or reflect an initial α-cluster structure was explored. Alpha clusters observed in fusion reactions exceed the predictions of the standard statistical model. This experiment provides a measure of how clusterization is impacted by the increasing neutron-richess of the system. In the experiment at GANIL we investigated fusion in 19 O + 12 C and 20 O + 12 C. This experiment utilized the recently developed active-target detector MuSIC@Indiana. Using this proven, highly efficient, active-target detector we measured the fusion excitation function for these neutron-rich systems. Grounded by these experimental measurements, theoretical models were used to examine the role of unpaired valence neutrons on the fusion cross-section at energies just above the fusion barrier.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Reassessment of PHDS Fulcrum40h High Purity Germanium (HPGe) Detector System Performance

This report presents a comprehensive evaluation of the updated PHDS Fulcrum40h High Purity Germanium (HPGe) detector system, benchmarking its performance, usability, and software capabilities against the current National Nuclear Security Administration (NNSA) Nuclear Emergency Support Team (NEST) HPGe Detector System Requirements Document. Systematic measurements were conducted using a single Fulcrum40h detector to assess key parameters including gamma efficiency and resolution, neutron detection efficiency, gamma pulse-pileup response, and gamma-to-neutron crosstalk. The Fulcrum40h system, acquired in August 2022, has undergone recent updates by PHDS to address deficiencies identified following the initial NEST requirements release. The results provide critical insights into the detector’s operational capabilities and compliance with NNSA NEST standards.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurement of Neutron Multiplicity in Charged Current Neutrino Interactions on Oxygen

The Accelerator Neutrino Neutron Interaction Experiment (ANNIE) is a 26-ton gadolinium-doped water Cherenkov detector located 100~meters downstream in the Booster Neutrino Beam (BNB) at the Fermi National Accelerator Laboratory (Fermilab). Its primary goals are to (1) measure the neutron yield from $\nu_\mu$ interactions as a function of momentum transfer $Q^2$ so that neutrino-nucleus interaction models can be better constrained, and (2) demonstrate the power of novel, fast-timing detectors with the first deployment of Large Area Picosecond PhotoDetectors (LAPPDs). Current knowledge of neutrino-nucleus interactions fall short in modeling the topologies of such interactions, leading to inaccurate reconstruction of event kinematics such as particle energy, direction, and vertex. As a consequence, the accuracy of cross section measurements is impacted, which is necessary for precise physics measurements. Neutrons are an indication of inelasticity and affect the determination of the energy of the parent neutrino. Quantifying the neutron yield is a step towards reducing the associated uncertainties, and thus improving our understanding of these complex interactions and benefiting the next generation of long-baseline neutrino experiments. ANNIE will make use of LAPPDs to measure neutron multiplicity of CC-0$\pi$ $\nu_\mu$ interactions on oxygen, making it the first experiment to deploy an array of these photodetectors. Because the LAPPD is a novel photodetection technology, much customization is required to integrate it into existing electronics. The first half of this thesis covers the significant progress made towards the first deployment of the LAPPD system. From its test stand at Fermilab, the LAPPD system was systematically tested and put together until deployment readiness was achieved. I present my contributions to the design, fabrication, and testing of the waterproof housing and cables, and the commissioning of the LVHV board that powers the LAPPD and its readout electronics. These efforts brought the LAPPD system significantly closer to deployment, and eventually first data. The second half of this thesis presents the vertex and energy reconstruction algorithms developed to analysis the beam data with PMT-only information. While much progress has been made towards the deployment of LAPPDs, with several in the detector tank, efforts to integrate the LAPPD datastream are in progress. Thus, I developed a ring edge detection technique using PMT data to fit the muon vertex and determine its energy. The analysis in this thesis finds average neutron yields of $\Bar{n}_{data} = 0.452 \pm 0.039 (\text{stat}) \pm 0.27 (\text{sys})$ for a selection of muon neutrino candidates in the fiducial volume of ANNIE and corrected with an averaged neutron detection efficiency. An equivalent analysis for simulated beam data results in an average neutron yield of $\Bar{n}_{MC} = 0.582 \pm 0.018 (\text{stat}) \pm 0.25 (\text{sys})$. Future work includes application of efficiency corrections at a positional level, quantification of all systematic uncertainties, and neutron multiplicity measurements with other event topologies.

43 PARTICLE ACCELERATORS↗

Evaluation of Polyethylene and Blank Pulsed Sphere Experiments Using Deuteron Transport Feature in COG

From the late 1960s to about 1985, LLNL undertook a series of ‘pulsed sphere’ experiments for 31 materials involving 148 different experiments using 75 different spheres. The purpose was to measure the neutron leakage spectra for different materials from 14-MeV neutrons generated by 3 H(d,n) 4 He reactions induced by an incident D+ beam from the Insulated Core Transfer (ICT) accelerator at LLNL. This deuteron beam was focused to impinge upon tritium loaded onto a titanium substrate within a low mass target assembly placed within the center of a spherical shell constructed from the material of interest. COG is a three-dimensional, continuous energy, Monte Carlo code, developed by Lawrence Livermore National Laboratory (LLNL). Recent additions to COG include alpha and deuteron particle transport in order to directly calculate (α,n) and 3 H(d,n) 4 He reactions, and resulting neutron emission spectra. Results of the direct deuteron transport calculation for the 0.8 MFP (mean free path) polyethylene sphere with PILOT B detector was previously published. The purpose of this paper is to present expanded COG results showing the neutron peak from deuterium buildup ( 2 H(d,n) 3 He) due to tritium decay in the target. Cross section data libraries used are ENDF/B-VIII.0 for neutrons and ENDF/B-VII.1 for deuterons, respectively.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Passive and active neutron signatures of 233 U for nondestructive assay

The thorium fuel cycle is emerging as an attractive alternative to conventional nuclear fuel cycles, as it does not require the enrichment of uranium for long-term sustainability. The operating principle of this fuel cycle is the irradiation of 232 Th to produce 233 U, which is fissile and sustains the fission chain reaction. 233 U poses unique challenges for nuclear safeguards, as it is associated with a uniquely extreme γ-ray environment from 232 U contamination, which limits the feasibility of the γ-ray-based assay, as well as more conservative accountability requirements than for 235 U set by the International Atomic Energy Agency. Consequently, instrumentation used for safeguarding 235 U in traditional fuel cycles may be inapplicable. It is essential that the nondestructive signatures of 233 U be characterized so that nuclear safeguards can be applied to thorium fuel-cycle facilities as they come online. In this work, a set of 233 U 3 O 8 plates, containing 984 g 233 U, was measured at the National Criticality Experiments Research Center. A high-pressure 4 He gaseous scintillation detector, which is insensitive to γ-rays, was used to perform a passive fast neutron spectral signature measurement of 233 U 3 O 8 , and was used in conjunction with a pulsed deuterium-tritium neutron generator to demonstrate the differential die-away signature of this material. Furthermore, an array of 3 He detectors was used in conjunction with the same neutron generator to measure the delayed neutron time profile of 233 U, which is unique to this nuclide. These measurements provide a benchmark for future nondestructive assay instrumentation development, and demonstrate a set of key neutron signatures to be leveraged for nuclear safeguards in the thorium fuel cycle.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Ames collaborative study of cosmic ray neutrons

The results of a collaborative study to define both the neutron flux and the spectrum more precisely and to develop a dosimetry package that can be flown quickly to altitude for solar flare events are described. Instrumentation and analysis techniques were used which were developed to measure accelerator-produced radiation. The instruments were flown in the Ames Research Center high altitude aircraft. Neutron instrumentation consisted of Bonner spheres with both active and passive detector elements, threshold detectors of both prompt-counter and activation-element types, a liquid scintillation spectrometer based on pulse-shape discrimination, and a moderated BF3 counter neutron monitor. In addition, charged particles were measured with a Reuter-Stokes ionization chamber system and dose equivalent with another instrument. Preliminary results from the first series of flights at 12.5 km (41,000 ft) are presented, including estimates of total neutron flux intensity and spectral shape and of the variation of intensity with altitude and geomagnetic latitude.

Hewitt, J. E.↗

Fission foil detector calibrations with high energy protons

Fission foil detectors (FFD's) are passive devices composed of heavy metal foils in contact with muscovite mica films. The heavy metal nuclei have significant cross sections for fission when irradiated with neutrons and protons. Each isotope is characterized by threshold energies for the fission reactions and particular energy-dependent cross sections. In the FFD's, fission fragments produced by the reactions are emitted from the foils and create latent particle tracks in the adjacent mica films. When the films are processed surface tracks are formed which can be optically counted. The track densities are indications of the fluences and spectra of neutrons and/or protons. In the past, detection efficiencies have been calculated using the low energy neutron calibrated dosimeters and published fission cross sections for neutrons and protons. The problem is that the addition of a large kinetic energy to the (n,nucleus) or (p,nucleus) reaction could increase the energies and ranges of emitted fission fragments and increase the detector sensitivity as compared with lower energy neutron calibrations. High energy calibrations are the only method of resolving the uncertainties in detector efficiencies. At high energies, either proton or neutron calibrations are sufficient since the cross section data show that the proton and neutron fission cross sections are approximately equal. High energy proton beams have been utilized (1.8 and 4.9 GeV, 80 and 140 MeV) for measuring the tracks of fission fragments emitted backward and forward.

Benton, E. V.↗