Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Neutron Detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 883 records · Page 49

A comparison of Monte Carlo fission models for safeguards neutron coincidence counters

Monte Carlo simulation is a powerful tool used to model neutron coincidence detectors for international safeguards. The simulation has typically sampled properties such as the fission neutron multiplicity, energy, and direction, from independent probability density functions. However, multiplicity counters detect event-based neutron correlations and thus more accurate fission event modeling is needed. To respond to this need, the Fission Reaction Event Yield Algorithm (FREYA) and the Cascading Gamma-ray Multiplicity with Fission (CGMF) models were added in the newest version of MCNP, MCNP6.2. The models simulate individual fission events conserving momentum, energy, and angular momentum such that correlated particles are emitted. The effects of the new models on simulations of safeguards neutron coincidence counters were studied and compared to standard MCNP simulations. The MCNPX-PoliMi model was also included in the comparison. The properties of fission neutrons from safeguards relevant isotopes were compared to literature references. Then a hypothetical simplified detector was modeled to isolate the effects of specific differences between models. Experimental measurements from previous work were modeled and agreements were compared. Lastly, the probabilities of correlated events occurring in the experimental measurements were calculated with the different models. For example, the probability was calculated of detecting neutrons from both induced fission in uranium and spontaneous fission of Cf-252 in the same fission chain.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Scanning of vehicles for nuclear materials

Might a nuclear-armed terrorist group or state use ordinary commerce to deliver a nuclear weapon by smuggling it in a cargo container or vehicle? This delivery method would be the only one available to a sub-state actor, and it might enable a state to make an unattributed attack. Detection of a weapon or fissile material smuggled in this manner is difficult because of the large volume and mass available for shielding. Here I review methods for screening cargo containers to detect the possible presence of nuclear threats. Because of the large volume of innocent international commerce, and the cost and disruption of secondary screening by opening and inspection, it is essential that the method be rapid and have a low false-positive rate. Shielding can prevent the detection of neutrons emitted spontaneously or by induced fission. The two promising methods are muon tomography and high energy X-radiography. If they do not detect a shielded threat object they can detect the shield itself.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Application of neutron interrogation techniques to corrosion detection

This paper discusses a technique which may be able to detect corrosion by determining the presence of oxygen at the corroded site via a neutron inelastic gamma reaction. Initial experiments have been performed using a Pu-239/Be neutron source and a NaI(T1) gamma-ray detector. From the results it was concluded that a 1 mm thickness of aluminum oxide would not be detected.

Birt, E. A.↗

Imaging Based Detector with Efficient Scintillators for Neutron Diffraction Measurements

The Anger Camera developed by the detector group at the Oak Ridge National Laboratory was utilized for the present work for its unique advantage of employing multiple modules to obtain large active measurement area for detecting diffracted/scattered thermal neutrons. Considering the relatively small flux associated with diffracted/scattered neutrons, suitable efficiency with high spatial resolution is a requirement for utilizing two-dimensional imaging detectors. The potential to implement pulse shape (in addition to pulse height) discrimination-based scintillators further enhances the ability to detect diffracted neutrons with improved signal to noise ratio. In this paper, initial results associated with 6Li glass-based scintillator will be presented. The authors explored the feasibility of using this system to detect and quantify diffraction peaks and peak shifts at the Neutron Residual Stress Facility (NRSF2), High Flux Isotope Reactor (HFIR) in the Oak Ridge National Laboratory (ORNL). Suitable camera mounting and shielding had to be developed. Reference measurements using polycrystalline powders with known atomic planar spacing will be discussed along with measurement settings associated with expected resolution for peak shift measurements. Initial results are promising and demonstrate that a suitable scintillation-based neutron detecting system is viable for residual stress-based diffraction measurements. Small area detectors are also feasible with suitable consideration to scattering volume and distance to detector.

Seals, Matthew↗

Dark matter or regular matter in neutron stars? How to tell the difference from the coalescence of compact objects

The mirror twin Higgs model is a candidate for (strongly-interacting) complex dark matter, which mirrors SM interactions with heavier quark masses. A consequence of this model are mirror neutron stars—exotic stars made entirely of mirror matter, which are significantly smaller than neutron stars and electromagnetically dark. This makes mergers of two mirror neutron stars detectable and distinguishable in gravitational wave observations, but can we observationally distinguish between regular neutron stars and those that may contain some mirror matter? This is the question we study in this paper, focusing on two possible realizations of mirror matter coupled to standard model matter within a compact object: (i) mirror matter captured by a neutron star and (ii) mirror neutron star-neutron star coalescences. Regarding (i), here we find that (nonrotating) mirror-matter-admixed neutron stars no longer have a single mass-radius sequence, but rather exist in a two-dimensional mass-radius plane. Regarding (ii), we find that binary systems with mirror neutron stars would span a much wider range of chirp masses and completely different binary Love relations, allowing merger remnants to be very light black holes. The implications of this are that gravitational wave observations with advanced LIGO and Virgo, and x-ray observations with NICER, could detect or constrain the existence of mirror matter through searches with wider model and parameter priors.

79 ASTRONOMY AND ASTROPHYSICS↗

A Prototype Large Area Detector Module for Muon Scattering Tomography

Abstract-Shielded special nuclear materials (SNM) are of concern as some fissile isotopes have low gamma and neutron emission rates. These materials are also easily shielded to the point where their passive emissions are comparable to background. Consequently, shielded SNM is very challenging for passive radiation detection portals which scan cargo containers. One potential solution for this is to utilise the natural cosmic ray muon background and examine how these muons scatter from materials inside the container volume, terms; the muon scattering tomography (MST) technique measures the three-dimensional localised scattering at all points within a cargo container, providing a degree of material discrimination. There is the additional benefit that the MST signal increases with the presence of more high density shielding materials, in contrast to passive radiation detection. Simulations and calculations suggest that the effectiveness of the technique is sensitive to the tracking accuracy amongst other parameters, motivating the need to develop practical detector systems that are capable of tracking cosmic ray muons. To this end, we have constructed and tested a 2 m by 2 m demonstration module based on gaseous drift chambers and triggered by a large area scintillator-based detector, which is readout by wavelength shifting fibres. We discuss its design, construction, characterisation and operational challenges. (authors)

42 ENGINEERING↗

Concept for Inclusion of Analytical and Computational Capability in Optical Plume Anomaly Detection (OPAD) for Measurement of Neutron Flux

Researchers are working on many konts to make possible high speed, automated classification and quantification of constituent materials in numerous environments. NASA's Marshall Space Flight Center has implemented a system for rocket engine flow fields/plumes; the Optical Plume Anomaly Detection (OPAD) system was designed to utilize emission and absorption spectroscopy for monitoring molecular and atomic particulates in gas plasma. An accompanying suite of tools and analytical package designed to utilize information collected by OPAD is known as the Engine Diagnostic Filtering System (EDIFIS). The current combination of these systems identifies atomic and molecular species and quantifies mass loss rates in H2/O2 rocket plumes. Additionally, efforts are being advanced to hardware encode components of the EDIFIS in order to address real-time operational requirements for health monitoring and management. This paper addresses the OPAD with its tool suite, and discusses what is considered a natural progression: a concept for migrating OPAD towards detection of high energy particles, including neutrons and gamma rays. The integration of these tools and capabilities will provide NASA with a systematic approach to monitor space vehicle internal and external environment.

Patrick, M. Clinton↗

Neutron Monitoring Systems for the Characterisation of Nuclear Fuel and Waste - Methodology and Applications - 12055

The most characteristic behaviour of nuclear fuel or waste contaminated by fission material or isotopes resulting from fissile processes is the emission of neutrons. At the same time because of the high penetration of the material by neutrons, they are an ideal probe for measurement by non-destructive assay. The detection and data analysis in this case is quite different compared to methods using gamma measuring techniques. Neutron detection monitors have been in routine operation for a long time, showing their excellent detection capabilities. The neutron monitors designed for different applications have demonstrated their capabilities during daily operation in the field of burned up fuel elements and for nuclear waste with alpha activity. Lately the data analysis was refined and the quality of the results was improved by using MCNP calculations. Last but not least the layout and the calibration of neutron monitors are nowadays unfeasible without support by MCNP simulations. In the field of non-destructive assay the neutron monitors are undisputed. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A Fast Pulsed Neutron Source for Time-of-Flight Detection of Nuclear Materials and Explosives

AASC has built a fast pulsed neutron source based on the Dense Plasma Focus (DPF). The more current version stores only 100 J but fires at {approx}10-50 Hz and emits {approx}10{sup 6}n/pulse at a peak current of 100 kA. Both sources emit 2.45{+-}0.1 MeV(DD) neutron pulses of {approx}25-40 ns width. Such fast, quasi-monoenergetic pulses allow time-of-flight detection of characteristic emissions from nuclear materials or high explosives. A test is described in which iron targets were placed at different distances from the point neutron source. Detectors such as Stilbene and LaBr3 were used to capture inelastically induced, 847 keV gammas from the iron target. Shielding of the source and detectors eliminated most (but not all) of the source neutrons from the detectors. Gated detection, pulse shape analysis and time-of-flight discrimination enable separation of gamma and neutron signatures and localization of the target. A Monte Carlo simulation allows evaluation of the potential of such a fast pulsed source for a field-portable detection system. The high rep-rate source occupies two 200 liter drums and uses a cooled DPF Head that is <500 cm{sup 3} in volume.

07 ISOTOPE AND RADIATION SOURCES↗

Passive assay of plutonium metal plates using a fast-neutron multiplicity counter

Here, we developed a fast-neutron multiplicity counter based on organic scintillators (EJ-309 liquid and stilbene). The system detects correlated photon and neutron multiplets emitted by fission reactions, within a gate time of tens of nanoseconds. The system was used at Idaho National Laboratory to assay a variety of plutonium metal plates. A coincidence counting strategy was used to quantify the 240 Pu effective mass of the samples. Coincident neutrons, detected within a 40-ns coincidence window, show a monotonic trend, increasing with the 240 Pu-effective mass (in this work, we tested the 0.005–0.5 kg range). After calibration, the system estimated the 240 Pu effective mass of an unknown sample ( 240 Pu eff >50 g) with an uncertainty lower than 1% in a 4-min assay time.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

THE ABUNDANCES OF LIGHT NEUTRON-CAPTURE ELEMENTS IN PLANETARY NEBULAE. III. THE IMPACT OF NEW ATOMIC DATA ON NEBULAR SELENIUM AND KRYPTON ABUNDANCE DETERMINATIONS

The detection of neutron(n)-capture elements in several planetary nebulae (PNe) has provided a new means of investigating s-process nucleosynthesis in low-mass stars. However, a lack of atomic data has inhibited accurate trans-iron element abundance determinations in astrophysical nebulae. Recently, photoionization (PI) and recombination data were determined for Se and Kr, the two most widely detected n-capture elements in nebular spectra. We have incorporated these new data into the photoionization code Cloudy. To test the atomic data, numerical models were computed for 15 PNe that exhibit emission lines from multiple Kr ions. We found systematic discrepancies between the predicted and observed emission lines that are most likely caused by inaccurate PI and recombination data. These discrepancies were removed by adjusting the Kr{sup +}–Kr{sup 3+} PI cross sections within their cited uncertainties and the dielectronic recombination rate coefficients by slightly larger amounts. From grids of models spanning the physical conditions encountered in PNe, we derive new, broadly applicable ionization correction factor (ICF) formulae for calculating Se and Kr elemental abundances. The ICFs were applied to our previous survey of near-infrared [Kr iii] and [Se iv] emission lines in 120 PNe. The revised Se and Kr abundances are 0.1–0.3 dex lower than former estimates, with average values of [Se/(O, Ar)] = 0.12 ± 0.27 and [Kr/(O, Ar)] = 0.82 ± 0.29, but correlations previously found between their abundances and other nebular and stellar properties are unaffected. We also find a tendency for high-velocity PNe that can be associated with the Galactic thick disk to exhibit larger s-process enrichments than low-velocity PNe belonging to the thin-disk population.

79 ASTRONOMY AND ASTROPHYSICS↗

Porosity detection in electron beam-melted Ti-6Al-4V using high-resolution neutron imaging and grating-based interferometry

A high-resolution neutron tomography system and a grating-based interferometer are used to explore electron beam-melted titanium test objects. The high-resolution neutron tomography system (attenuation-based imaging) has a pixel size of 6.4 µm, appropriate for detecting voids near 25 µm over a (1.5 cm) 3 volume. The neutron interferometer provides dark-field (small-angle scattering) images with a pixel size of 30 µm. Moreover, the interferometer can be tuned to a scattering length, in this case, 1.97 µm, with a field-of-view of (6 cm)3. The combination of high-resolution imaging with grating-based interferometry provides a way for nondestructive testing of defective titanium samples. A chimney-like pore structure was discovered in the attenuation and dark-field images along one face of an electron beam-melted (EBM) Ti-6Al-4V cube. Tomographic reconstructions of the titanium samples are utilized as a source for a binary volume and for skeletonization of the pores. As a result, the dark-field volume shows features with dimensions near and smaller than the interferometer auto-correlation scattering length.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Statistical characterization of the reproducibility of neutron emission of small plasma focus devices

The purpose of this work is to discuss the techniques related to the detection of fast pulsed neutrons produced in plasma focus (PF) devices, the statistical analysis of the corresponding data, and the methodologies for evaluation of the device performance in low emission neutron sources. A general mathematical framework is presented for the assessment of the reproducibility of the neutron emission of small PF devices given the shot-to-shot distribution and detector efficiency. The effect on the reproducibility in case of using two independent detectors is also discussed. The analysis is applied to the neutron emission of the plasma focus device PF-50J operating in repetitive mode (0.1-0.5 Hz and 65 J bank energy).

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Prospects for direct detection of black hole formation in neutron star mergers with next-generation gravitational-wave detectors

A direct detection of black hole formation in neutron star mergers would provide invaluable information about matter in neutron star cores and finite temperature effects on the nuclear equation of state. We study black hole formation in neutron star mergers using a set of 190 numerical relativity simulations consisting of long-lived and black-hole-forming remnants. The postmerger gravitational-wave spectrum of a long-lived remnant has greatly reduced power at a frequency 𝑓 greater than 𝑓 peak , for 𝑓 ≳ 4 kHz, with 𝑓 peak ∈ [2.5,4] kHz. On the other hand, black-hole-forming remnants exhibit excess power in the same large 𝑓 region and manifest exponential damping in the time domain characteristic of a quasinormal mode. We demonstrate that the gravitational-wave signal from a collapsed remnant is indeed a quasinormal ringing. We report on the opportunity for direct detections of black hole formation with next-generation gravitational-wave detectors such as Cosmic Explorer and Einstein Telescope and set forth the tantalizing prospect of such observations up to a distance of 100 Mpc for an optimally oriented and located source with an SNR of 4.

Astronomy & Astrophysics↗

Reconstruction of β-Delayed Neutron Energy Spectra from Recoil-Ion Spectroscopy of Trapped Ions

Here Beta-delayed one-neutron (βn) emission has been investigated by confining radioactive ions in an ion trap and detecting the β particles and recoiling nuclei that emerge following decay. In this approach, the βn energy spectrum and branching ratio can be deduced without needing to detect the neutrons, as the neutron emission is inferred from the observed time of flight of the recoiling ions. This paper details the dominant effects that influence the extraction of the neutron energy from the time-of-flight measurement and explores the impact they have on the energy calibration and resolution.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Identification of Near-infrared [Se iii] and [Kr vi] Emission Lines in Planetary Nebulae

We identify [Se iii] 1.0994 μ m in the planetary nebula (PN) NGC 5315 and [Kr vi] 1.2330 μ m in three PNe from spectra obtained with the Folded-Port InfraRed Echellette (FIRE) spectrometer on the 6.5 m Baade Telescope. Se and Kr are the two most widely detected neutron-capture elements in astrophysical nebulae, and can be enriched by s -process nucleosynthesis in PN progenitor stars. The detection of [Se iii] 1.0994 μ m is particularly valuable when paired with observations of [Se iv] 2.2864 μ m, as it can be used to improve the accuracy of nebular Se abundance determinations, and allows Se ionization correction factor (ICF) schemes to be empirically tested for the first time. We present new effective collision strength calculations for Se{sup 2+} and Kr{sup 5+}, which we use to compute ionic abundances. In NGC 5315, we find that the Se abundance computed from Se{sup 3+}/H{sup +} is lower than that determined with ICFs that incorporate Se{sup 2+}/H{sup +}. We compute new Kr ICFs that take Kr{sup 5+}/H{sup +} into account, by fitting correlations found in grids of Cloudy models between Kr ionic fractions and those of more abundant elements, and use these to derive Kr abundances in four PNe. Observations of [Se iii] and [Kr vi] in a larger sample of PNe, with a range of excitation levels, are needed to rigorously test the ICF prescriptions for Se and our new Kr ICFs.

79 ASTRONOMY AND ASTROPHYSICS↗

High sensitivity, solid state neutron detector

An apparatus (200) for detecting slow or thermal neutrons (160) including an alpha particle-detecting layer (240) that is a hydrogenated amorphous silicon p-i-n diode structure. The apparatus includes a bottom metal contact (220) and a top metal contact (250) with the diode structure (240) positioned between the two contacts (220, 250) to facilitate detection of alpha particles (170). The apparatus (200) includes a neutron conversion layer (230) formed of a material containing boron-10 isotopes. The top contact (250) is pixilated with each contact pixel extending to or proximate to an edge of the apparatus to facilitate electrical contacting. The contact pixels have elongated bodies to allow them to extend across the apparatus surface (242) with each pixel having a small surface area to match capacitance based upon a current spike detecting circuit or amplifier connected to each pixel. The neutron conversion layer (860) may be deposited on the contact pixels (830) such as with use of inkjet printing of nanoparticle ink.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Prompt Neutron Multiplicity Measurements with Portable Detectors

Mobile detection of kilogram quantities of special nuclear materials (SNM) during maritime transportation is a challenging problem for the U.S. Department of Homeland Security. Counting neutrons emitted by the SNM and partitioning them from background neutrons of multiple origins is the most effective passive means of detecting the SNM. Unfortunately, neutron detection, counting, and partitioning in a maritime environment is complex due to the presence of spallation neutrons (commonly known as “ship effect”) and to the complicated nature of the neutron scattering in that environment. This work studied the possibilities of building a prototype neutron detector using boron- 10 (10B) as the converter in a novel form factor called “straws” that would address the above problem by examining multiplicity distributions of neutrons originating from a fissioning source. Currently, commercially manufactured fission meters (FM) are available that separate cosmic neutrons from non-cosmic neutrons and quantitatively determine the strength of a fissioning source; however, these FMs use 3He, which is becoming increasingly difficult to procure; also the size and weight of a commercial FM is not conducive to manual neutron detection operations in a maritime environment. The current project may provide a near-term solution to the crisis that has arisen from the global scarcity of 3He by offering a viable alternative to the FM. The prototype detector provides a large-area, efficient, lightweight, more granular neutron responsive detection surface (to facilitate imaging) to ease the application of the new FMs. A novel prototype fission meter is being designed at National Security Technologies, LLC, using a thin uniform coating of 10B as neutron converter (only 1 micron thick) inside a large array of thin (4 mm diameter) copper tubes. The copper tubes are only 2-mil thick, and each holds the stretched anode wire under tension and high voltage. The tubes are filled with proportional counter gas (a mixture of 90% Ar and 10% CO2). The tubes operate in proportional counter mode and attract mobile charged particles (alpha-particles) created in the nuclear interaction 10B(n, a)7Li. Several MCNPX calculations covering the substantial design parameter space of neutron multiplicity detectors have been performed and are presented. Our detector’s thermal neutron detection efficiency is compared to two Ortec commercial products, the Fission Meter and Detective-EX. Pulse height spectra originating from the charged particles created in the nuclear reaction 10B(n, a) 7Li* + 2.310 MeV (94%) – excited state (1) and 10B(n, a) 7Li + 2.792 MeV (6%) – ground state (2) are examined, and the response to incident gamma rays are demonstrated.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗