Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “NOISE INTENSITY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 883 records · Page 49

X-ray imaging of extended objects using nonoverlapping redundant array

A common problem associated with X-ray imaging using coded apertures is the reconstruction of low-intensity extended objects. In the decoding of such objects, the overlapping images from the multiple pinholes give rise to noise cross talk and, in many cases, also to signal cross talk. In this paper, an alternate approach is proposed based on the principle used in an earlier (Yin et al., 1980) laboratory device for the real-time viewing of X-ray objects. It is shown that with this approach, the nonoverlapping redundant array, the sidelobes in the point spread function are not eliminated but merely displaced through a suitable choice of geometry. In this manner, the sidelobes no longer contribute to the background in the vicinity of a reconstructed image, and both signal and noise cross talks are completely eliminated. It may now be possible to reconstruct extended X-ray objects in 3-D by simple optical correlation and tomographically by a computer.

Yin, L.-I.↗

Estimating Sonic Boom Metrics Across a Community Using a Kalman Filter

As part of the Quesst mission, NASA will fly the X‑59 aircraft over selected communities to evaluate community responses to low-intensity sonic booms. The purpose of these community tests is to determine the dose-response relationship between the noise exposure metrics and the community response. The independent variables for the dose-response relationship are the noise exposure metrics experienced by survey respondents within the community. Two sources of noise exposure metrics are available in each community: measurements at sparse locations throughout the community, and calculations from propagation models across the community. Both the measurements and calculations are subject to uncertainty. A Kalman filter is proposed to combine the measured and calculated noise exposure metrics to obtain the best estimate of the true noise exposure metrics across the community. The noise exposure metrics estimated by the Kalman filter have lower uncertainty than either the measured or calculated noise exposure metrics alone. Simulations demonstrate that the Kalman filter produces a more accurate estimate of the true noise exposure metrics than other noise estimation methods.

Sonic boom↗

Parametrization of Fresnel returns

It appears appropriate to use the intensity correlation function to investigate variations of a reflected signal component, and a scattered signal component, because it is determined by the relative motions, i.e., fluctuations of structual changes. An example of a correlation function is shown which can be separated into three parts: (1) a very fast drop between zero and the neighboring lag which is due to uncorrelated noise; (2) a smooth decrease at small large up to a few seconds which is due to scattering (this decrease can be approximated by a parabola); (3) a rather slow fadeout which is due to Frensel reflection and very gradually approaches zero correlation for longer lags. The noise contribution (part 1) must be eliminated by normalizing the correlation function by means of the zero-lag value which follows from a parabolic approximation. As signal intensity variations are directly connected to turbulent variations in a scattering medium or the changes of a reflecting discontinuity, parts (2) and (3) of the normalized correlation functions in terms of characteristic structure parameters, are evaluated.

Rottger, J.↗

LHC Beam Diffusion Dependence on RF Noise: Models And Measurements

Radio Frequency (RF) accelerating system noise and non-idealities can have detrimental impact on the LHC performance through longitudinal motion and longitudinal emittance growth. A theoretical formalism has been developed to relate the beam and RF loop dynamics with the bunch length growth [1]. Measurements were conducted at LHC to validate the formalism, determine the performance limiting RF components, and provide the foundation for beam diffusion estimates for higher energies and intensities. A brief summary of these results is presented in this work. During a long store, the relation between the energy lost to synchrotron radiation and the noise injected to the beam by the RF accelerating voltage determines the growth of the bunch energy spread and longitudinal emittance. Since the proton synchrotron radiation in the LHC is very low, the beam diffusion is extremely sensitive to RF perturbations. The theoretical formalism presented in [1], suggests that the noise experienced by the beam depends on the cavity phase noise power spectrum, filtered by the beam transfer function, and aliased due to the periodic sampling of the accelerating voltage signal V{sub c}. Additionally, the dependence of the RF accelerating cavity noise spectrum on the Low Level RF (LLRF) configurations has been predicted using time-domain simulations and models [2]. In this work, initial measurements at the LHC supporting the above theoretical formalism and simulation predictions are presented.

43 PARTICLE ACCELERATORS↗

Relating a Jet-Surface Interaction Experiment to a Commercial Supersonic Transport Aircraft Using Numerical Simulations

Reynolds-Averaged Navier-Stokes (RANS) simulations were performed for a commercial supersonic transport aircraft concept and experimental hardware models designed to represent the installed propulsion system of the conceptual aircraft in an upcoming test campaign. The purpose of the experiment is to determine the effects of jet-surface interactions from supersonic aircraft on airport community noise. RANS simulations of the commercial supersonic transport aircraft concept were performed to relate the representative experimental hardware to the actual aircraft. RANS screening simulations were performed on the proposed test hardware to verify that it would be free from potential rig noise and to predict the aerodynamic forces on the model hardware to assist with structural design. The simulations showed a large region of separated flow formed in a junction region of one of the experimental configurations. This was dissimilar with simulations of the aircraft and could invalidate the noise measurements. This configuration was modified and a subsequent RANS simulation showed that the size of the flow separation was greatly reduced. The aerodynamic forces found on the experimental models were found to be relatively small when compared to the expected loads from the model’s own weight.Reynolds-Averaged Navier-Stokes (RANS) simulations were completed for two configurations of a three-stream inverted velocity profile (IVP) nozzle and a baseline single-stream round nozzle (mixed-flow equivalent conditions). For the Sideline and Cutback flow conditions, while the IVP nozzles did not reduce the peak turbulent kinetic energy on the lower side of the jet plume, the IVP nozzles did significantly reduce the size of the region of peak turbulent kinetic energy when compared to the jet plume of the baseline nozzle cases. The IVP nozzle at Sideline conditions did suffer a region of separated flow from the inner stream nozzle splitter that did produce an intense, but small, region of turbulent kinetic energy in the vicinity of the nozzle exit. When viewed with the understanding that jet noise is directly related to turbulent kinetic energy, these IVP nozzle simulations show the potential to reduce noise to observers located below the nozzle. However, these RANS simulations also show that some modifications may be needed to prevent the small region of separated flow-induced turbulent kinetic energy from the inner stream nozzle splitter at Sideline conditions.

Reynolds-Averaged Navier Stokes↗

Perpendicular blade vortex interaction and its implications for helicopter noise prediction: Wave-number frequency spectra in a trailing vortex for BWI noise prediction

Perpendicular blade vortex interactions are a common occurrence in helicopter rotor flows. Under certain conditions they produce a substantial proportion of the acoustic noise. However, the mechanism of noise generation is not well understood. Specifically, turbulence associated with the trailing vortices shed from the blade tips appears insufficient to account for the noise generated. The hypothesis that the first perpendicular interaction experienced by a trailing vortex alters its turbulence structure in such a way as to increase the acoustic noise generated by subsequent interactions is examined. To investigate this hypothesis a two-part investigation was carried out. In the first part, experiments were performed to examine the behavior of a streamwise vortex as it passed over and downstream of a spanwise blade in incompressible flow. Blade vortex separations between +/- one eighth chord were studied for at a chord Reynolds number of 200,000. Three-component velocity and turbulence measurements were made in the flow from 4 chord lengths upstream to 15 chordlengths downstream of the blade using miniature 4-sensor hot wire probes. These measurements show that the interaction of the vortex with the blade and its wake causes the vortex core to loose circulation and diffuse much more rapidly than it otherwise would. Core radius increases and peak tangential velocity decreases with distance downstream of the blade. True turbulence levels within the core are much larger downstream than upstream of the blade. The net result is a much larger and more intense region of turbulent flow than that presented by the original vortex and thus, by implication, a greater potential for generating acoustic noise. In the second part, the turbulence measurements described above were used to derive the necessary inputs to a Blade Wake Interaction (BWI) noise prediction scheme. This resulted in significantly improved agreement between measurements and calculations of the BWI noise spectrum especially for the spectral peak at low frequencies, which previously was poorly predicted.

Devenport, William J.↗

Effect of photon counting shot noise on total internal reflection microscopy

Total internal reflection microscopy (TIRM) measures changes in the distance between a colloidal particle and a transparent substrate by measuring the scattering intensity of the particle illuminated by an evanescent wave. From the distribution of the recorded separation distances, the height-dependent effective potential φ(z) between the colloidal particle and the substrate can be measured. In this work, we show that spatial resolution with which TIRM can measure φ(z) is limited by the photon counting statistics of the scattered laser light. Here, we develop a model to evaluate the effect of photon counting statistics on different potential profiles using Brownian dynamics simulations and experiments. Our results show that the effect of photon counting statistics depends on spatial gradients ∂φ/∂z of the potential, with the result that sharp features tend to be significantly blurred. We further establish the critical role of photon counting statistics and the intensity integration time τ in TIRM measurements, which is a trade-off between narrowing the width of the photon counting distribution and capturing the instantaneous position of the probe particle.

47 OTHER INSTRUMENTATION↗

Improving Ventilation and Saving Energy: Final Report on Indoor Environmental Quality and Energy Monitoring in Sixteen Relocatable Classrooms

An improved HVAC system for portable classrooms was specified to address key problems in existing units. These included low energy efficiency, poor control of and provision for adequate ventilation, and excessive acoustic noise. Working with industry, a prototype improved heat pump air conditioner was developed to meet the specification. A one-year measurement-intensive field-test of ten of these IHPAC systems was conducted in occupied classrooms in two distinct California climates. These measurements are compared to those made in parallel in side by side portable classrooms equipped with standard 10 SEER heat pump air conditioner equipment. The IHPAC units were found to work as designed, providing predicted annual energy efficiency improvements of about 36 percent to 42 percent across California's climate zones, relative to 10 SEER units. Classroom ventilation was vastly improved as evidenced by far lower indoor minus outdoor CO2 concentrations. TheIHPAC units were found to provide ventilation that meets both California State energy and occupational codes and the ASHRAE minimum ventilation requirements; the classrooms equipped with the 10 SEER equipment universally did not meet these targets. The IHPAC system provided a major improvement in indoor acoustic conditions. HVAC system generated background noise was reduced in fan-only and fan and compressor modes, reducing the nose levels to better than the design objective of 45 dB(A), and acceptable for additional design points by the Collaborative on High Performance Schools. The IHPAC provided superior ventilation, with indoor minus outdoor CO2 concentrations that showed that the Title 24 minimum ventilation requirement of 15 CFM per occupant was nearly always being met. The opposite was found in the classrooms utilizing the 10 SEER system, where the indoor minus outdoor CO2 concentrations frequently exceeded levels that reflect inadequate ventilation. Improved ventilation conditions in the IHPAC lead to effective removal of volatile organic compounds and aldehydes, on average lowering the concentrations by 57 percent relative to the levels in the 10 SEER classrooms. The average IHPAC to 10 SEER formaldehyde ratio was about 67 percent, indicating only a 33 percent reduction of this compound in indoor air. The IHPAC thermal control system provided less variability in occupied classroom temperature than the 10 SEER thermostats. The average room temperatures in all seasons tended to be slightly lower in the IHPAC classrooms, often below the lower limit of the ASHRAE 55 thermal comfort band. State-wide and national energy modeling provided conservative estimates of potential energy savings by use of the IHPAC system that would provide payback a the range of time far lower than the lifetime of the equipment. Assuming electricity costs of $0.15/kWh, the perclassroom range of savings is from about $85 to $195 per year in California, and about $89 to $250 per year in the U.S., depending upon the city. These modelsdid not include the non-energy benefits to the classrooms including better air quality and acoustic conditions that could lead to improved health and learning in school. Market connection efforts that were part of the study give all indication that this has been a very successful project. The successes include the specification of the IHPAC equipment in the CHPS portable classroom standards, the release of a commercial product based on the standards that is now being installed in schools around the U.S., and the fact that a public utility company is currently considering the addition of the technology to its customer incentive program. These successes indicate that the IHPAC may reach its potential to improve ventilation and save energy in classrooms.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Weight growth due to resonant simulation particles and a modified {delta}f algorithm with smooth switching between {delta}f and total-f methods

When applying the standard {delta}f particle-in-cell simulation method to simulate linear and nonlinear collective instabilities with coherent structures, wave-particle interaction may result in large weight growth for resonant or nearly resonant simulation particles. In this paper, we demonstrate that the large noise associated with the large weight of nearly resonant simulation particles can produce significant error fields at the nonlinear stage of the instability. To overcome this deleterious effect, we have developed a modified {delta}f method that contains a smooth switching algorithm between the {delta}f and total-f methods. Before the switch, the simulation effectively makes use of the desirable low-noise feature of the {delta}f method for small weight to accurately follow unstable mode structures. When the weight function becomes large during the nonlinear phase, the low-noise advantage of the {delta}f method ceases to be significant and the simulation is switched to the total-f method to avoid the large noise induced by nearly resonant simulation particles. This algorithm has been successfully applied to simulation studies of the electrostatic Harris instability driven by large temperature anisotropy in high-intensity charged particle beams typical of applications in high current accelerators, including high-energy density physics and heavy ion fusion.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Primary donor triplet states of Photosystem I and II studied by Q-band pulse ENDOR spectroscopy

The photoexcited triplet state of the “primary donors” in the two photosystems of oxygenic photosynthesis has been investigated by means of electron-nuclear double resonance (ENDOR) at Q-band (34 GHz). The data obtained represent the first set of 1 H hyperfine coupling tensors of the 3 P700 triplet state in PSI and expand the existing data set for 3 P680. We achieved an extensive assignment of the observed electron-nuclear hyperfine coupling constants (hfcs) corresponding to the methine α-protons and the methyl group β-protons of the chlorophyll (Chl) macrocycle. The data clearly confirm that in both photosystems the primary donor triplet is located on one specific monomeric Chl at cryogenic temperature. In comparison to previous transient ENDOR and pulse ENDOR experiments at standard X-band (9–10 GHz), the pulse Q-band ENDOR spectra demonstrate both improved signal-to-noise ratio and increased resolution. The observed ENDOR spectra for 3 P700 and 3 P680 differ in terms of the intensity loss of lines from specific methyl group protons, which is explained by hindered methyl group rotation produced by binding site effects. Contact analysis of the methyl groups in the PSI crystal structure in combination with the ENDOR analysis of 3 P700 suggests that the triplet is located on the Chl a' (P A ) in PSI. The results also provide additional evidence for the localization of 3 P680 on the accessory Chl D1 in PSII.

59 BASIC BIOLOGICAL SCIENCES↗

Initial beam emission spectroscopy diagnostic system on HL-2A tokamak

A beam emission spectroscopy system is being developed and deployed on the HL-2A tokamak to measure local low wavenumber (k ⊥ ρ i < 1) density fluctuations by measuring the Doppler-shifted emission from a 50 kV deuterium heating neutral beam. High spatial resolution (Δr ≤ 1 cm, Δz ≤ 1.5 cm) measurements are achieved with customized in-vacuum optics. High frequency, high-gain preamplifiers sample the light intensity at a Nyquist frequency of 1 MHz and achieve a high S/N ratio via high optical throughput, low-noise preamplifiers, and high quantum efficiency photodiodes. A first set of 16 detector channels [configured in an 8 (radial) × 2 (poloidal) array] has been installed and tested at HL-2A, covering the radial range r/a = 0.8–1.1. The frequency and wavenumber spectra have been measured under different plasma conditions. Initial measurements have demonstrated the capability of measuring edge plasma density fluctuation spectra and the poloidal flow velocity fields with a high S/N ratio.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Quantum phase-sensitive diffraction and imaging using entangled photons

We propose a quantum diffraction imaging technique whereby one photon of an entangled pair is diffracted off a sample and detected in coincidence with its twin. The image is obtained by scanning the photon that did not interact with matter. We show that when a dynamical quantum system interacts with an external field, the phase information is imprinted in the state of the field in a detectable way. The contribution to the signal from photons that interact with the sample scales as ∝ I p 1 / 2 , where I p is the source intensity, compared with ∝ I p of classical diffraction. This makes imaging with weak fields possible, providing high signal-to-noise ratio, avoiding damage to delicate samples. A Schmidt decomposition of the state of the field can be used for image enhancement by reweighting the Schmidt modes contributions.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Predicting dust emission using galactic 21 cm data

Understanding large-angular-scale galactic foregrounds is crucial for future CMB experiments aiming to detect B-mode polarization from primordial gravitational waves. Traditionally, the dust component has been separated using its different frequency dependence. However, using non-CMB observations has potential to increase fidelity and decrease the re-construction noise. In this exploratory paper we investigate the capability of galactic 21 cm observations to predict the dust foreground in intensity. We train a neural network to predict the dust foreground as measured by the Planck Satellite from the full velocity data-cube of galactic 21 cm emission as measured by the HI4PI survey. We demonstrate that information in the velocity structure clearly improves the predictive power over both a simple integrated emission model and a simple linear model. The improvement is significant at arc-minute scales but more modest at degree scales. Finally, this proof of principle on temperature data indicates that it might also be possible to improve foreground polarization templates from the same input data.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The Extended Q-Range Small Angle Neutron Scattering Diffractometer at the SNS

The Extended Q-Range Small Angle Neutron Scattering Diffractometer (EQ-SANS) at the Spallation Neutron Source is designed to have wide neutron momentum transfer (Q) coverage, high neutron beam intensity, and good wavelength resolution. In addition, the design and construction of the instrument aim at achieving maximum signal to noise ratio by minimizing the background. The instrument is located on the 60Hz SNS target. It has a primary flight path of 14m. Its secondary flight path varies from ~1m to 10m. One of the key components in the primary flight path is the neutron optics, consisting of a true-curved multi channel beam bender and sections of neutron guides. The optics is optimized to reduce the neutron transport loss to a minimum, thereby maximizing the available flux on sample. It also enables the avoidance of the direct line of sight of the neutron moderator at downstream locations. The instrument has three bandwidth-limiting choppers. These choppers effectively eliminate higher frame neutrons up to ~38 from the beam. A frame overlap mirror further cleans up the beam by reflecting out neutrons whose wavelengths are longer than ~33 . The bandwidth choppers also allow a frame-skipping mode of operation, which enables the EQ-SANS diffractometer to achieve a dynamic Q-range equivalent to that of a similar machine on a 20Hz source. The two-dimensional low-angle detector, based on 3He tube technologies, offers very high counting rates and counting efficiency. Initial operations have shown that the instrument has achieved its best-in-class design requirement.

EQ-SANS↗

High-speed X-ray imaging pixel array detector for synchrotron bunch isolation

A wide-dynamic-range imaging X-ray detector designed for recording successive frames at rates up to 10 MHz is described. X-ray imaging with frame rates of up to 6.5 MHz have been experimentally verified. The pixel design allows for up to 8–12 frames to be stored internally at high speed before readout, which occurs at a 1 kHz frame rate. An additional mode of operation allows the integration capacitors to be re-addressed repeatedly before readout which can enhance the signal-to-noise ratio of cyclical processes. This detector, along with modern storage ring sources which provide short (10–100 ps) and intense X-ray pulses at megahertz rates, opens new avenues for the study of rapid structural changes in materials. The detector consists of hybridized modules, each of which is comprised of a 500 µm-thick silicon X-ray sensor solder bump-bonded, pixel by pixel, to an application-specific integrated circuit. The format of each module is 128 × 128 pixels with a pixel pitch of 150 µm. In the prototype detector described here, the three-side buttable modules are tiled in a 3 × 2 array with a full format of 256 × 384 pixels. Lastly, we detail the characteristics, operation, testing and application of the detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Investigation of realistic PET simulations incorporating tumor patient's specificity using anthropomorphic models: Creation of an oncology database

Purpose: The GATE Monte Carlo simulation toolkit is used for the implementation of realistic PET simulations incorporating tumor heterogeneous activity distributions. The reconstructed patient images include noise from the acquisition process, imaging system's performance restrictions and have limited spatial resolution. For those reasons, the measured intensity cannot be simply introduced in GATE simulations, to reproduce clinical data. Investigation of the heterogeneity distribution within tumors applying partial volume correction (PVC) algorithms was assessed. The purpose of the present study was to create a simulated oncology database based on clinical data with realistic intratumor uptake heterogeneity properties.Methods: PET/CT data of seven oncology patients were used in order to create a realistic tumor database investigating the heterogeneity activity distribution of the simulated tumors. The anthropomorphic models (NURBS based cardiac torso and Zubal phantoms) were adapted to the CT data of each patient, and the activity distribution was extracted from the respective PET data. The patient-specific models were simulated with the Monte Carlo Geant4 application for tomography emission (GATE) in three different levels for each case: (a) using homogeneous activity within the tumor, (b) using heterogeneous activity distribution in every voxel within the tumor as it was extracted from the PET image, and (c) using heterogeneous activity distribution corresponding to the clinical image following PVC. The three different types of simulated data in each case were reconstructed with two iterations and filtered with a 3D Gaussian postfilter, in order to simulate the intratumor heterogeneous uptake. Heterogeneity in all generated images was quantified using textural feature derived parameters in 3D according to the ground truth of the simulation, and compared to clinical measurements. Finally, profiles were plotted in central slices of the tumors, across lines with heterogeneous activity distribution for visual assessment.Results: The accuracy of the simulated database was assessed against the original clinical images. The PVC simulated images matched the clinical ones best. Local, regional, and global features extracted from the PVC simulated images were closest to the clinical measurements, with the exception of the size zone variability and the mean intensity values, where heterogeneous tumors showed better reproducibility. The profiles on PVC simulated tumors after postfiltering seemed to represent the more realistic heterogeneous regions with respect to the clinical reference.Conclusions: In this study, the authors investigated the input activity map heterogeneity in the GATE simulations of tumors with heterogeneous activity distribution. The most realistic heterogeneous tumors were obtained by inserting PVC activity distributions from the clinical image into the activity map of the simulation. Partial volume effect (PVE) can play a crucial role in the quantification of heterogeneity within tumors and have an important impact on applications such as patient follow-up during treatment and assessment of tumor response to therapy. The development of such a database incorporating patient anatomical and functional variability can be used to evaluate new image processing or analysis algorithms, while providing control of the ground truth, which is not available when dealing with clinical datasets. The database includes all images used and generated in this study, as well as the sinograms and the attenuation phantoms for further investigation. It is freely available to the interested reader of the journal at http://www.med.upatras.gr/oncobase/.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-C-206-01: Impact of Charge Sharing Effect On Sub-Pitch Resolution for CZT-Based Photon Counting CT Systems

Purposes: Photon counting CT is a new imaging technology that can provide tissue composition information such as calcium/iodine content quantification. Cadmium zinc telluride CZT is considered a good candidate the photon counting CT due to its relatively high atomic number and band gap. One potential challenge is the degradation of both spatial and energy resolution as the fine electrode pitch is deployed (<50 µm). We investigated the extent of charge sharing effect as functions of gap width, bias voltage and depth-of-interaction (DOI). Methods: The initial electron cloud size and diffusion process were modeled analytically. The valid range of charge sharing effect refers to the range over which both signals of adjacent electrodes are above the triggering threshold (10% of the amplitude of 60keV X-ray photons). The intensity ratios of output in three regions (I1/I2/I3: left pixel, gap area and right pixel) were calculated. With Gaussian white noises modeled (a SNR of 5 based upon the preliminary experiments), the sub-pitch resolution as a function of the spatial position in-between two pixels was studied. Results: The valid range of charge sharing increases linearly with depth-of-interaction (DOI) but decreases with gap width and bias voltage. For a 1.5mm thickness CZT detector (pitch: 50µm, bias: 400 V), the range increase from ∼90µm up to ∼110µm. Such an increase can be attributed to a longer travel distance and the associated electron cloud broadening. The achievable sub-pitch resolution is in the range of ∼10–30µm. Conclusion: The preliminary results demonstrate that sub-pixel spatial resolution can be achieved using the ratio of amplitudes of two neighboring pixels. Such ratio may also be used to correct charge loss and help improve energy resolution of a CZT detector. The impact of characteristic X-rays hitting adjacent pixels (i.e., multiple interaction) on charge sharing is currently being investigated.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A companion quasar to 3C345

The discovery of a new quasistellar object (QSO) which presents the strongest evidence to date for the membership of quasars in rich clusters is reported. During X-ray observations of quasar 3C345, a serendipitous X-ray source located 8 arcmin northeast of the quasar was discovered. The observed flux of the new source is 3.2 x 10 to the -13th erg/sq cm/sec in the 0.5-4.5 keV band. Three separate observations over a six-month period failed to show intensity variability in excess of the statistical uncertainty in the count rate. The spectrum shows a modest signal-to-noise ratio but four strong emission lines. It is suggested that the redshift agreement between the two QSOs indicates a common membership in a cluster of galaxies which may well be a rich cluster.

Margon, B.↗