Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Mount”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 883 records · Page 49

CACTI ARM Mobile Facility (AMF) Measurements of Ice Nucleating Particles

The dataset comprises measures, using Colorado State University's Ice Spectrometer (IS, an immersion freezing device with a range from 0°C down to -26 to -29°C) of atmosperic ice nucleating particle (INP) concentrations taken on ARM's Mobile Facility (AMF-1) Aerosol Observing System, near Villa Yacanto in central Argentina, during the Cloud, Aerosol, and Complex Terrain Interactions (CACTI) Experiment. A filter sampler was mounted on the AOS trailer (2 m below the AOS inlet). Single-use filter units open to the atmosphere fitted with pre-cleaned and pre-sterilized, 47-mm dia. Nuclepore polycarbonate filters were used. Filters were typically drawn for an 8-hour period, totaling 6000 liters sampled on average. After collection, filters were stored at -20°C until processed. Initial processing to obtain spectra of INP number concentration active via the immersion freezing mechanism versus temperature was conducted using CSU's IS instrument (McCluskey et al., 2018). For measurment of INPs, collected aerosol particles were re-suspended in 7-8 mL of 0.1 µm-filtered deionized (DI) water. Aliquots of each suspension, and serial dilutions, were dispensed into trays which were fit into aluminum blocks in the IS. Samples are cooled at 0.33°C min-1 and the freezing temperatures of wells recorded automatically. Cumulative INP concentrations were determined by first calculating the INPs per mL of suspension based on Vali (1971) and then converting to concentration per standard liter of air using the proportion of the total liquid sample dispensed and the air sample volumes. An aliquot of suspension fro selected samples were also heat treated (95°C for 20 min) to denature and deactivate biological INPs, and another aliquot digested in 10% H2O2 at 95°C under UV-B to remove all organic carbon INPs. McCluskey, C. S., J. Ovadnevaite, M. Rinaldi, J. Atkinson, F. Belosi, D. Ceburnis, S. Marullo, T. C. J. Hill, U. Lohmann, Z. A. Kanji, C. O’Dowd, S. M. Kreidenweis, P. J. DeMott, 2018: Marine and Terrestrial Organic Ice Nucleating Particles in Pristine Marine to Continentally-Influenced Northeast Atlantic Air Masses, Journal of Geophysical Research: Atmospheres, 123, 6196–6212, https://doi.org/10.1029/2017JD028033. Vali, G., 1971: Quantitative evaluation of experimental results on the heterogeneous freezing nucleation of supercooled liquids. J. Atmos. Sci., 28, 402–409.

54 ENVIRONMENTAL SCIENCES↗

AEROICESTUDY-Colorado State University Ice Spectrometer

The dataset comprises measures, using Colorado State University's Ice Spectrometer (IS, an immersion freezing device with a range from 0 °C down to -26 to -29 °C) of atmospheric ice nucleating particle (INP) concentrations taken at ARM's Southern Great Plains (SGP) Site Guest Instrument Facility (GIF), in Lamont, Oklahoma, during the Aerosol-Ice Formation Closure Pilot Study (AEROICESTUDY). A filter sampler was mounted approximately 6 m above ground level atop the GIF rooftop platform. Single-use filter units open to the atmosphere fitted with pre-cleaned and pre-sterilized, 47-mm diameter Nuclepore polycarbonate filters were used. Filters were typically drawn for either a full day period (9AM-5PM CDT) or broken up into morning (9AM-12PM CDT) and afternoon (1PM-5PM CDT) periods. Additionally, 4 overnight filters were taken (6PM-8AM CDT). The volume of air filtered was typically between 3000 and 8000 standard liters for daily samples. After collection, filters were stored at -20 °C until processed. Initial processing to obtain spectra of INP number concentration active via the immersion freezing mechanism versus temperature was conducted using CSU's IS instrument (McCluskey et al., 2018). For measurement of INPs, collected aerosol particles were re-suspended in 8 mL of 0.1 µm-filtered deionized (DI) water. Aliquots of each suspension, and serial dilutions, were dispensed into trays which were fit into aluminum blocks in the IS. Samples were cooled at 0.33 °C per min and the freezing temperatures of wells recorded automatically. Cumulative INP concentrations were determined by first calculating the INPs per mL of suspension based on Vali (1971) and then converting to concentration per standard liter of air using the proportion of the total liquid sample dispensed and the air sample volumes. Two-tailed, 95% confidence intervals for binomial sampling were based on Equation 2 from Agresti and Coull (1998). Aliquots of suspensions from selected samples were also heat treated (95 °C for 20 min) to denature and deactiv

54 ENVIRONMENTAL SCIENCES↗

MOSAiC-Colorado State University Ice Spectrometer

This data set contains atmospheric ice nucleating particle (INP) measurements, using Colorado State University&rsquo;s (CSU) Ice Spectrometer (IS), of filter collections taken at the U.S. DOE ARM AMF2 site onboard the R/V Polarstern P-deck during the Multidisciplinary Drifting Observatory for the Study of Arctic Climate (MOSAiC) field campaign. Samples were collected from October 27, 2019 to September 24, 2020. A filter sampler was mounted approximately 15 m above ground level on a railing in proximity to (and approximately 3 m below) the Aerosol Observation System (AOS) inlet. Single-use filter units open to the atmosphere were pre-cleaned and pre-loaded with 47-mm diameter Nuclepore polycarbonate (0.2 &micro;m pore-diameter) filters. Filters were typically drawn for a three-day period, with an average volume of air filtered of 87,000 standard liters. Total volumes were calculated through recorded daily flow rates using a mass flow meter (TSI). After collection, filters were stored and transported frozen until analysis using CSU&rsquo;s IS instrument (McCluskey et al., 2018). Aerosol particles were first re-suspended in 8 mL of 0.1 &micro;m-filtered deionized (DI) water. Aliquots of each suspension, and corresponding 11-fold dilutions, were dispensed into polymerase chain reaction (PCR) trays and placed into the aluminum blocks of the IS. Samples were cooled at approximately 0.33 &deg;C min -1 and freezing detected optically with corresponding temperatures recorded. Cumulative INP concentrations were determined through calculating the number of INPs per mL of suspension (Vali, 1971) and converting to concentration per standard L of air by accounting for the proportion of liquid used and volume of air collected. All samples were corrected for the number of INPs on the average of four field blanks (cleaned, handled, transported, and analyzed in the same way without air flow). Two-tailed, 95% confidence intervals for binomial sampling are provided (Agresti and Coull, 1998). Select samples were also heat treated (95 &deg;C for 20 min) to denature and deactivate biological INPs present and digested in 10% H 2 O 2 at 95 &deg;C under UV-B for 20 min to remove any organic carbon INPs. Agresti, A, and BA Coull. 1998. "Approximate is better than &ldquo;exact&rdquo; for interval estimation of binomial proportions." American Statistics 52: 119&ndash;126. https://doi.org/10.2307/2685469 McCluskey, CS, J Ovadnevaite, M Rinaldi, J Atkinson, F Belosi, D Ceburnis, &hellip; and PJ DeMott. 2018. "Marine and Terrestrial Organic Ice-Nucleating Particles in Pristine Marine to Continentally Influenced Northeast Atlantic Air Masses." Journal of Geophysical Research: Atmospheres 123 (11): 6196&ndash;6212, https://doi.org/10.1029/2017JD028033 Vali, G. 1971. "Quantitative Evaluation of Experimental Results and the Heterogeneous Freezing Nucleation of Supercooled Liquids." Journal of the Atmospheric Sciences 28: 402-209. https://doi.org/10.1175/1520-0469(1971)028<0402:QEOERA>2.0.CO;2

54 ENVIRONMENTAL SCIENCES↗

COMBLE-ISLAS water isotopes in precipitation (COMBLEISLASISO)

During the measurement period, precipitation was sampled on daily to sub-daily basis with a sampling kit consiting of a clear plastic box (60x40x40 cm) mounted to a ground structure. Daily sampling lasted from 22 Feb to 24 Mar 2020. At a fixed time of day (10 UTC), samples were collected and the sampling box cleaned for the next sample. Additionally, during intense observations periods (IOPs) announced by ISLAS, ARMS scientists increased sampling frequency to sub-daily sampling. During the campaign period, 2 IOPs were conducted, with in total 12 samples taken. IOP1 lasted from 27 Feb 10 to 02 Mar 2020, and IOP2 lasted from 12 Mar to 14 Mar 2020. Solid precipitation in the box was then melted, transferred to an 8 ml glass vial, sealed and shipped to FARLAB (University of Bergen, Norway) for stable water isotope analysis. Measured stable isotope composition of precipitation samples will be related to conditions at other sampling locations, and at the evaporation site to inform about conservation of water isotope quantities. In the period from 22 Feb to 24 Mar, 23 daily samples were collected at 10 UTC for stable water isotope analysis. During the entire sampling period, a high variability of precipitation phase was encountered. Most samples were recovered in the form of graupel/snow (12 samples), as rain (7 samples), and the remaining samples fell as graupel, snow, rain or frozen rain. Precipitation amounts varied between <1 mm (26 Feb) and 140 mm (25 Feb) within the sampling box. Furthermore, higher-resolution sampling was conducted during 2 intense observation periods (IOPs). During IOP1, lasting from 27 Feb 10 UTC to 02 Mar 10 UTC, 7 samples were collected, all of them as solid phase precipitation. IOP2 lasted from 12 Mar 10 UTC to 14 Mar 09 UTC, and 5 samples (all as graupel/snow) were collected. Samples were processed according to FARLAB standard measurement procedures. In short, samples were transferred to 1.5 ml glass vials with rubber/PTFE septa (part #548-0907, VWR, USA). An autosampler (A0325, Picarro Inc) transferred ca. 2&micro;l per injection into a high-precision vapourizer (A0211, Picarro Inc, USA) heated to 110&deg;C. After blending with dry N2 (< 5 ppm H2O) the gas mixture was directed into the measurement cavity of a Cavity-Ring Down Spectrometer (L2140-i, Picarro Inc) for about 7 min with a typical water concentration of 20 000 ppm. Memory effects were reduced by two times measuring a vapour mixture at a mixing ratio of 50 000 ppm, obtained from 2 injections of 2 &micro;l for 5 min at the beginning of each new sample vial. Thereafter, another 6 injections of 2 &micro;l per sample were measured individually as described above, and averages of the last 5 injections were used for further processing. Three standards were measured at the beginning and end of each batch, including a drift standard DI2 (&delta;D: -50.72&plusmn;0.73 permil, &delta;18O: -7.63&plusmn;0.10 permil), and for calibration the laboratory standards GLW (&delta;D: -307.79&plusmn;0.75 permil, &delta;18O: -40.02&plusmn;0.07 permil) and EVAP2 (&delta;D: 9.52&plusmn;0.65 permil, &delta;18O: 1.81&plusmn;0.13 permil). A detailed calibration report is included with the final uploaded data set.

54 ENVIRONMENTAL SCIENCES↗

Combined Mesonet and Tracker

Title: Combined Mesonet and Trackers (UNL Mobile Mesonets) Authors University of Nebraska PI: Adam Houston, UNL Professor (ahouston2@unl.edu) Mailing Address: 126 Bessey Hall P.O. Box 880340 Lincoln, NE 68588-0340 CoMeT Overview The University of Nebraska-Lincoln operates three Combined Mesonet and Tracker (CoMeTs). CoMeTs are Ford Explorers (model years 2015, 2017, and 2019) with forward-mounted suites of meteorological sensors and dual moonroofs, combining the capability of a mobile mesonet to collect near-surface observations with the capability of an unmanned aircraft systems (UAS) tracker vehicle, which enables an observer in the second row of seats to see the aircraft and maintain compliance with Federal Aviation Administration policies on UAS operation. The CoMeTs collect observations of slow temperature and humidity at ~2 m above ground level (AGL) using a Vaisala HMP155A, fast temperature at ~2 m AGL using a Campbell Scientific 109SS-L thermistor, pressure at ~2.5 m AGL using a Vaisala PTB210, wind speed and direction at ~3.25 m AGL using an R.M. Young 05103 propeller anemometer, and vehicle heading using a KVH Industries C-100 fluxgate compass (Barbieri et al. 2019). The HMP155A and 109SS-L thermistor are shielded and aspirated within a U-tube (Waugh and Frederickson 2010; Houston et al. 2016). This list of sensors is also included in the CoMeT data file metadata. Manufacturer specifications for these instruments are given in Table 1 of Hanft and Houston (2018). The reported measured quantities are summarized below.CoMeT-3 was funded through an equipment allocation included in the NSF TORUS award (AGS-1824649). Instrument Description The specific sensors included on each CoMeT are summarized in the table at the end of this section. In general each CoMeT collects observations of slow temperature and humidity at ~2 m above ground level (AGL) using a Vaisala HMP155, fast temperature at ~2 m AGL using a Campbell Scientific 109SS-L thermistor, pressure at ~2.5 m AGL using a Vaisala PTB210 barometer with a Gill pressure port, wind speed and direction at ~3.25 m AGL using an R.M. Young 05103 propeller anemometer, position using a Garmin 19x HVS receiver, and vehicle heading using a KVH Industries C-100 fluxgate compass. The HMP155 and 109SS are shielded and aspirated within a U-tube (Waugh and Frederickson 2010; Houston et al. 2016). Fast temperature and corrected RH measurements (using sensors housed within the U-tube) have a time constant of 10-12 s based on data collected across a temperature and RH shock during the CLOUD-MAP 2017 calibration/validation tests on June 26, 2017. Vehicle speed was < 10 kts for this test. CoMeT-1 CoMeT-2 CoMeT-3 Slow Temperature Slow RH Vaisala HMP155A-L20-PT Part #: 22280-7 Vaisala HMP155E Part #: E1AA11A0B1A1A0A Vaisala HMP155E Part #: E1AA11A0B1A1A0A Fast temperature Campbell Scientific 109SS-L20-PT Part #: 21448-3 Campbell Scientific 109SS-L12-PW Part #: 21448-109 Campbell Scientific 109SS-L12-PW Part #: 21448-150 Pressure Vaisala PTB-210 Part #: A1A1B Gill Pressure Port Part #: 61002 Vaisala PTB-210 Part #: A1A1B Gill Pressure Port Part #: 61002 Vaisala PTB-210 Part #: A1A1B Gill Pressure Port Part #: 61002 Wind RM Young 05103-L20-PT Part #: 18435-310 RM Young 05103-L20-PW Part #: 18435-244 RM Young 05103-L20-PW Part #: 18435-244 GPS Garmin GPS 19x HVS (NMEA 0183) Part #: 010-01010-00 Garmin GPS 19x HVS (NMEA 0183) Part #: 010-01010-00 Garmin GPS 19x HVS (NMEA 0183) Part #: 010-01010-00 Compass KVH C-100 Part #: 01-0177-15 KVH C-100 Part #: 01-0177-15 KVH C-100 Part #: 01-0177-15 Logger Campbell Scientific CR6-NA-XT-SW Part #: 28385-9 Campbell Scientific CR6-WIFI-XT-SW Part #: 28385-6 Campbell Scientific CR6-WIFI-XT-SW Part #: 28385-6 Data Collection and Real-Time Processing The reported measured quantities are summarized in the table below. Quantity Units Source Epoch time Seconds GPS Latitude and longitude Degrees GPS Altitude m GPS Pressure hPa PTB210 Temperature (fast) deg C 109SS-L Temperature (slow) deg C HMP155 RH (slow) % HMP155 Vehicle speed m/s GPS Vehicle heading deg C-100 and GPS In addition to the measured variables, several derived variables are calculated. Corrected/fast relative humidity (%) Relative humidity is adjusted to the fast temperature following Richardson et al. (1998) and Houston et al. (2016). Water vapor mixing ratio (g/kg) Dew point temperature (&deg;C) Potential temperature (Kelvin) Virtual potential temperature (Kelvin) Equivalent potential temperature (Kelvin) Regular intercomparisons between all three CoMeTs were performed during TORUS 2019. Comparisons were also conducted between CoMeT-1 and CoMeT-2 during LAPSE-RATE (2018) on 14 July. In these intercomparisons, the vehicles were parked adjacent to each other aligned perpendicular to (and facing into) the wind. To minimize engine heating effects, intercomparisons were only conducted when the wind speed was >10 kts. Data Format Original data files for each deployment are saved as text files and then converted to NetCDF. NetCDF versions have units that are CF compliant and may not match the original units in the txt files. The naming convention for the NetCDF files is as follows: UNL.CoMeT3.{deployment date YYYYMMDD}.{start time of observation collection in UTC HHMM}.L2.{post-processing codes}.cdf example: UNL.CoMeT3.20190627.1931.L2.g1.f1.cdf Post-processing codes are included to track modifications to the raw data. These codes are closely connected to error flags associated with each record. Each letter corresponds to a particular instrument: g: GPS p: Barometer tf: Fast temperature ts: Slow temperature rh: Relative humidity f: Compass w: Wind monitor a: All instruments Each number corresponds to a particular post-processing action described more below. Measured and derived variables are included in the following table. Variable Heading Standard Name Units time Time seconds since 00:00:00, 01-01-1970 Alt Altitude meters lat Latitude degrees north lon Longitude degrees east fast_temp Air Temperature kelvin slow_temp Air Temperature kelvin pressure Air Pressure pascals logger_RH Relative Humidity percent calc_corr_RH Relative Humidity percent wind_speed Wind Speed meters per second wind_dir Wind From Direction degrees vehicle_dir Vehicle Direction degrees dewpoint Dew Point Temperature kelvin mixing_ratio Humidity Mixing Ratio g/g theta Air Potential Temperature kelvin theta_v Virtual Potential Temperature kelvin theta_e Equivalent Potential Temperature Kelvin error_flag The error_flag variable is a string that matches the post-processing codes listed above. All instruments will have an associated code, but will have a &ldquo;0&rdquo; if the datum is unchanged from the initial processed value. Error Codes The following table summarizes the error codes for data collected before 2020: Error Code Relevant CoMeT Description g1 1,2,3 Exact correction. GPS position and time reprocessed from raw data g2 1 As far as we can tell this is an exact correction to an error in the GPS time. During the correct time periods the time suddenly went backwards ~250s and stayed at this offset for 750s when it corrected itself. The offset was applied to the &ldquo;time warp&rdquo; period. p1 2 Approximate correction. Hole in the pressure tube connecting the pressure port to the barometer. Resulted in erroneously low air pressure measurements when the vehicle was in motion. Derived variables recalculated (dew point temperature [e depends on qv and p], water vapor mixing ratio, potential temperature, virtual potential temperature, equivalent potential temperature) a1 3 Exact correction. Missing data reprocessed from raw data a2 1 Bug fix to bias correction for ts1, ts2, and rh1: water vapor mixing ratio was off by a factor of 10 and virtual potential temperature was wrong because of this. f1 3 No correction, missing data. Fluxgate compass inoperable. Wind speed and direction calculated using GPS-derived vehicle heading instead. rh1 1 Approximate correction. Constant bias of +1.7% removed from relative humidity. Derived variables recalculated (corrected/fast relative humidity, dew point temperature, water vapor mixing ratio, virtual potential temperature, equivalent potential temperature) ts1 1 Approximate correction. Constant bias of +0.6 K removed from slow temperature. Derived variables recalculated (corrected/fast relative humidity, dew point temperature, water vapor mixing ratio, virtual potential temperature, equivalent potential temperature) ts2 1 Approximate correction. Constant bias of +1.0 K removed. Derived variables recalculated (corrected/fast relative humidity, dew point temperature, water vapor mixing ratio, virtual potential temperature, equivalent potential temperature) References Bolton, D., 1980: The Computation of Equivalent Potential Temperature. Mon. Wea. Rev., 108, 1046&ndash;1053, https://doi.org/10.1175/1520-0493(1980)108<1046:TCOEPT>2.0.CO;2. Hanft, W., and A. L. Houston, 2018: An Observational and Modeling Study of Mesoscale Air Masses with High Theta-E. Mon. Wea. Rev., 146, 2503&ndash;2524, https://doi.org/10.1175/MWR-D-17-0389.1.Wexler Houston, A. L., R. J. Laurence III, T. W. Nichols, S. Waugh, B. Argrow, and C. L. Ziegler, 2016: Intercomparison of unmanned aircraft-borne and mobile mesonet atmospheric sensors. Journal of Atmospheric and Oceanic Technology. 33, 1569-1582, doi: 10.1175/JTECH-D-15-0178.1. Lowe, P. R., 1977: An Approximating Polynomial for the Computation of Saturation Vapor Pressure. J. Applied Meteorology, 16, 100&ndash;103. Richardson, S. J., S. E. Frederickson, F. V. Brock, and J. A. Brotzge, 1998: Combination temperature and relative humidity probes: Avoiding large air temperature errors and associated relative humidity errors. Preprints, 10th Symp. On Meteorological Observations and Instrumentation, Phoenix, AZ, Amer. Meteor. Soc., 278&ndash;283. Waugh, S., and S. E. Frederickson, 2010: An improved aspirated temperature system for mobile meteorological observations, especially in severe weather. 25th Conf. on Severe Local Storms, Denver, CO, Amer. Meteor. Soc., P5.2. [Available online at https://ams.confex.com/ams/25SLS/techprogram/paper_176205.htm.]

54 ENVIRONMENTAL SCIENCES↗

Ka-Band Scanning ARM Cloud Radar (a1)

The Ka-Band Scanning ARM Cloud Radar (KASACR) records cloud properties. ARM's scanning cloud radars are dual-frequency, dual-polarization Doppler radars mounted on a common scanning pedestal. Each pedestal includes a Ka-band radar (2kW peak power) and the deployment location determines whether the second radar is a W-band (1.7 kW peak power) or an X-band (20 kW peak power). Beamwidths for Ka-bands paired with W-bands are roughly matched at 0.3 degrees. The X-band beamwidth is approximately 1 degree. Due to the narrow antenna beamwidth, ARM’s scanning cloud radars use scanning strategies unlike typical weather radars. Rather than focusing on plan position indicator, or PPI, scans, the KASACR uses range height indicator, or RHI, scans at numerous azimuths to obtain cloud volume data. Measurements collected with the KASACR are copolar and cross-polar radar reflectivity, Doppler velocity, spectra width and spectra when not scanning, and linear depolarization ratio. KASACR data from the 2018–2019 Cloud, Aerosol, and Complex Terrain Interactions (CACTI) field campaign in Argentina are now available as b1-level products. Building on the original CACTI operational data, the b1-level products feature improved data quality resulting from extensive analyses and corrections. The data are cross-calibrated to a common point, datastreams are corrected for operational issues that occurred during the campaign, and several data quality masks and basic derived products are incorporated. For more information, read the CACTI radar b1-level processing report.

54 ENVIRONMENTAL SCIENCES↗

Ka-Band Scanning ARM Cloud Radar (a1)

The Ka-Band Scanning ARM Cloud Radar (KASACR) records cloud properties. ARM's scanning cloud radars are dual-frequency, dual-polarization Doppler radars mounted on a common scanning pedestal. Each pedestal includes a Ka-band radar (2kW peak power) and the deployment location determines whether the second radar is a W-band (1.7 kW peak power) or an X-band (20 kW peak power). Beamwidths for Ka-bands paired with W-bands are roughly matched at 0.3 degrees. The X-band beamwidth is approximately 1 degree. Due to the narrow antenna beamwidth, ARM’s scanning cloud radars use scanning strategies unlike typical weather radars. Rather than focusing on plan position indicator, or PPI, scans, the KASACR uses range height indicator, or RHI, scans at numerous azimuths to obtain cloud volume data. Measurements collected with the KASACR are copolar and cross-polar radar reflectivity, Doppler velocity, spectra width and spectra when not scanning, and linear depolarization ratio. KASACR data from the 2018–2019 Cloud, Aerosol, and Complex Terrain Interactions (CACTI) field campaign in Argentina are now available as b1-level products. Building on the original CACTI operational data, the b1-level products feature improved data quality resulting from extensive analyses and corrections. The data are cross-calibrated to a common point, datastreams are corrected for operational issues that occurred during the campaign, and several data quality masks and basic derived products are incorporated. For more information, read the CACTI radar b1-level processing report.

54 ENVIRONMENTAL SCIENCES↗

wsacr2cfrcrras (a1)

ARM's scanning cloud radars are fully coherent dual-frequency, dual-polarization Doppler radars mounted on a common scanning pedestal. Each pedestal includes a Ka-band radar (2kW peak power) and the deployment location determines whether the second radar is a W-band (WSACR; 1.7 kW peak power) or X-band (XSACR; 20 kW peak power). Beamwidths at Ka and W bands are roughly matched at 0.3 degrees. Due to the narrow antenna beamwidth, ARM’s scanning cloud radars use scanning strategies that are unlike typical weather radars. Rather than focusing on plan position indicator, or PPI, scans, the Ka-SACR uses range height indicator, or RHI, scans at numerous azimuths to obtain cloud volume data. Measurements collected with the W-SACR are copolar and cross-polar radar reflectivity, Doppler velocity, spectra width and spectra when not scanning, and linear depolarization ration.

54 ENVIRONMENTAL SCIENCES↗

kasacrcfrspcxpol (a1)

The Ka-Band Scanning ARM Cloud Radar (KASACR) records cloud properties. ARM's scanning cloud radars are dual-frequency, dual-polarization Doppler radars mounted on a common scanning pedestal. Each pedestal includes a Ka-band radar (2kW peak power) and the deployment location determines whether the second radar is a W-band (1.7 kW peak power) or an X-band (20 kW peak power). Beamwidths for Ka-bands paired with W-bands are roughly matched at 0.3 degrees. The X-band beamwidth is approximately 1 degree. Due to the narrow antenna beamwidth, ARM’s scanning cloud radars use scanning strategies unlike typical weather radars. Rather than focusing on plan position indicator, or PPI, scans, the KASACR uses range height indicator, or RHI, scans at numerous azimuths to obtain cloud volume data. Measurements collected with the KASACR are copolar and cross-polar radar reflectivity, Doppler velocity, spectra width and spectra when not scanning, and linear depolarization ratio. KASACR data from the 2018–2019 Cloud, Aerosol, and Complex Terrain Interactions (CACTI) field campaign in Argentina are now available as b1-level products. Building on the original CACTI operational data, the b1-level products feature improved data quality resulting from extensive analyses and corrections. The data are cross-calibrated to a common point, datastreams are corrected for operational issues that occurred during the campaign, and several data quality masks and basic derived products are incorporated. For more information, read the CACTI radar b1-level processing report.

54 ENVIRONMENTAL SCIENCES↗

kasacrcfrspccross (a1)

The Ka-Band Scanning ARM Cloud Radar (KASACR) records cloud properties. ARM's scanning cloud radars are dual-frequency, dual-polarization Doppler radars mounted on a common scanning pedestal. Each pedestal includes a Ka-band radar (2kW peak power) and the deployment location determines whether the second radar is a W-band (1.7 kW peak power) or an X-band (20 kW peak power). Beamwidths for Ka-bands paired with W-bands are roughly matched at 0.3 degrees. The X-band beamwidth is approximately 1 degree. Due to the narrow antenna beamwidth, ARM’s scanning cloud radars use scanning strategies unlike typical weather radars. Rather than focusing on plan position indicator, or PPI, scans, the KASACR uses range height indicator, or RHI, scans at numerous azimuths to obtain cloud volume data. Measurements collected with the KASACR are copolar and cross-polar radar reflectivity, Doppler velocity, spectra width and spectra when not scanning, and linear depolarization ratio. KASACR data from the 2018–2019 Cloud, Aerosol, and Complex Terrain Interactions (CACTI) field campaign in Argentina are now available as b1-level products. Building on the original CACTI operational data, the b1-level products feature improved data quality resulting from extensive analyses and corrections. The data are cross-calibrated to a common point, datastreams are corrected for operational issues that occurred during the campaign, and several data quality masks and basic derived products are incorporated. For more information, read the CACTI radar b1-level processing report.

54 ENVIRONMENTAL SCIENCES↗

kasacrcfrspccopol (a1)

The Ka-Band Scanning ARM Cloud Radar (KASACR) records cloud properties. ARM's scanning cloud radars are dual-frequency, dual-polarization Doppler radars mounted on a common scanning pedestal. Each pedestal includes a Ka-band radar (2kW peak power) and the deployment location determines whether the second radar is a W-band (1.7 kW peak power) or an X-band (20 kW peak power). Beamwidths for Ka-bands paired with W-bands are roughly matched at 0.3 degrees. The X-band beamwidth is approximately 1 degree. Due to the narrow antenna beamwidth, ARM’s scanning cloud radars use scanning strategies unlike typical weather radars. Rather than focusing on plan position indicator, or PPI, scans, the KASACR uses range height indicator, or RHI, scans at numerous azimuths to obtain cloud volume data. Measurements collected with the KASACR are copolar and cross-polar radar reflectivity, Doppler velocity, spectra width and spectra when not scanning, and linear depolarization ratio. KASACR data from the 2018–2019 Cloud, Aerosol, and Complex Terrain Interactions (CACTI) field campaign in Argentina are now available as b1-level products. Building on the original CACTI operational data, the b1-level products feature improved data quality resulting from extensive analyses and corrections. The data are cross-calibrated to a common point, datastreams are corrected for operational issues that occurred during the campaign, and several data quality masks and basic derived products are incorporated. For more information, read the CACTI radar b1-level processing report.

54 ENVIRONMENTAL SCIENCES↗

kasacr2cfrspccwrhicopol (a1)

The Ka-Band Scanning ARM Cloud Radar (KASACR) records cloud properties. ARM's scanning cloud radars are dual-frequency, dual-polarization Doppler radars mounted on a common scanning pedestal. Each pedestal includes a Ka-band radar (2kW peak power) and the deployment location determines whether the second radar is a W-band (1.7 kW peak power) or an X-band (20 kW peak power). Beamwidths for Ka-bands paired with W-bands are roughly matched at 0.3 degrees. The X-band beamwidth is approximately 1 degree. Due to the narrow antenna beamwidth, ARM’s scanning cloud radars use scanning strategies unlike typical weather radars. Rather than focusing on plan position indicator, or PPI, scans, the KASACR uses range height indicator, or RHI, scans at numerous azimuths to obtain cloud volume data. Measurements collected with the KASACR are copolar and cross-polar radar reflectivity, Doppler velocity, spectra width and spectra when not scanning, and linear depolarization ratio. KASACR data from the 2018–2019 Cloud, Aerosol, and Complex Terrain Interactions (CACTI) field campaign in Argentina are now available as b1-level products. Building on the original CACTI operational data, the b1-level products feature improved data quality resulting from extensive analyses and corrections. The data are cross-calibrated to a common point, datastreams are corrected for operational issues that occurred during the campaign, and several data quality masks and basic derived products are incorporated. For more information, read the CACTI radar b1-level processing report.

54 ENVIRONMENTAL SCIENCES↗

Ka-Band Scanning ARM Cloud Radar (KASACR), 2nd Generation CF-Radial Spectral Data, Vertically-Pointing Scan, Cross Mode (a1-level)

The Ka-Band Scanning ARM Cloud Radar (KASACR) records cloud properties. ARM's scanning cloud radars are dual-frequency, dual-polarization Doppler radars mounted on a common scanning pedestal. Each pedestal includes a Ka-band radar (2kW peak power) and the deployment location determines whether the second radar is a W-band (1.7 kW peak power) or an X-band (20 kW peak power). Beamwidths for Ka-bands paired with W-bands are roughly matched at 0.3 degrees. The X-band beamwidth is approximately 1 degree. Due to the narrow antenna beamwidth, ARM’s scanning cloud radars use scanning strategies unlike typical weather radars. Rather than focusing on plan position indicator, or PPI, scans, the KASACR uses range height indicator, or RHI, scans at numerous azimuths to obtain cloud volume data. Measurements collected with the KASACR are copolar and cross-polar radar reflectivity, Doppler velocity, spectra width and spectra when not scanning, and linear depolarization ratio. KASACR data from the 2018–2019 Cloud, Aerosol, and Complex Terrain Interactions (CACTI) field campaign in Argentina are now available as b1-level products. Building on the original CACTI operational data, the b1-level products feature improved data quality resulting from extensive analyses and corrections. The data are cross-calibrated to a common point, datastreams are corrected for operational issues that occurred during the campaign, and several data quality masks and basic derived products are incorporated. For more information, read the CACTI radar b1-level processing report.

54 ENVIRONMENTAL SCIENCES↗

wsacr2cfrvpt (a1)

ARM's scanning cloud radars are fully coherent dual-frequency, dual-polarization Doppler radars mounted on a common scanning pedestal. Each pedestal includes a Ka-band radar (2kW peak power) and the deployment location determines whether the second radar is a W-band (WSACR; 1.7 kW peak power) or X-band (XSACR; 20 kW peak power). Beamwidths at Ka and W bands are roughly matched at 0.3 degrees. Due to the narrow antenna beamwidth, ARM’s scanning cloud radars use scanning strategies that are unlike typical weather radars. Rather than focusing on plan position indicator, or PPI, scans, the Ka-SACR uses range height indicator, or RHI, scans at numerous azimuths to obtain cloud volume data. Measurements collected with the W-SACR are copolar and cross-polar radar reflectivity, Doppler velocity, spectra width and spectra when not scanning, and linear depolarization ration.

54 ENVIRONMENTAL SCIENCES↗

kasacr2cfrspccwrhixpol (a1)

The Ka-Band Scanning ARM Cloud Radar (KASACR) records cloud properties. ARM's scanning cloud radars are dual-frequency, dual-polarization Doppler radars mounted on a common scanning pedestal. Each pedestal includes a Ka-band radar (2kW peak power) and the deployment location determines whether the second radar is a W-band (1.7 kW peak power) or an X-band (20 kW peak power). Beamwidths for Ka-bands paired with W-bands are roughly matched at 0.3 degrees. The X-band beamwidth is approximately 1 degree. Due to the narrow antenna beamwidth, ARM’s scanning cloud radars use scanning strategies unlike typical weather radars. Rather than focusing on plan position indicator, or PPI, scans, the KASACR uses range height indicator, or RHI, scans at numerous azimuths to obtain cloud volume data. Measurements collected with the KASACR are copolar and cross-polar radar reflectivity, Doppler velocity, spectra width and spectra when not scanning, and linear depolarization ratio. KASACR data from the 2018–2019 Cloud, Aerosol, and Complex Terrain Interactions (CACTI) field campaign in Argentina are now available as b1-level products. Building on the original CACTI operational data, the b1-level products feature improved data quality resulting from extensive analyses and corrections. The data are cross-calibrated to a common point, datastreams are corrected for operational issues that occurred during the campaign, and several data quality masks and basic derived products are incorporated. For more information, read the CACTI radar b1-level processing report.

54 ENVIRONMENTAL SCIENCES↗

W-Band ARM Scanning Cloud Radar (WSACR) 2nd Generation CF-Radial Spectral Data, Vertically-Pointing Scan, Co-Polarization Mode (a1)

ARM's scanning cloud radars are fully coherent dual-frequency, dual-polarization Doppler radars mounted on a common scanning pedestal. Each pedestal includes a Ka-band radar (2kW peak power) and the deployment location determines whether the second radar is a W-band (WSACR; 1.7 kW peak power) or X-band (XSACR; 20 kW peak power). Beamwidths at Ka and W bands are roughly matched at 0.3 degrees. Due to the narrow antenna beamwidth, ARM’s scanning cloud radars use scanning strategies that are unlike typical weather radars. Rather than focusing on plan position indicator, or PPI, scans, the Ka-SACR uses range height indicator, or RHI, scans at numerous azimuths to obtain cloud volume data. Measurements collected with the W-SACR are copolar and cross-polar radar reflectivity, Doppler velocity, spectra width and spectra when not scanning, and linear depolarization ration.

54 ENVIRONMENTAL SCIENCES↗

Ka-Band Scanning ARM Cloud Radar (KASACR), 2nd Generation CF-Radial Spectral Data, Vertically-Pointing Scan, Cross-Polarization Mode (a1-level)

The Ka-Band Scanning ARM Cloud Radar (KASACR) records cloud properties. ARM's scanning cloud radars are dual-frequency, dual-polarization Doppler radars mounted on a common scanning pedestal. Each pedestal includes a Ka-band radar (2kW peak power) and the deployment location determines whether the second radar is a W-band (1.7 kW peak power) or an X-band (20 kW peak power). Beamwidths for Ka-bands paired with W-bands are roughly matched at 0.3 degrees. The X-band beamwidth is approximately 1 degree. Due to the narrow antenna beamwidth, ARM’s scanning cloud radars use scanning strategies unlike typical weather radars. Rather than focusing on plan position indicator, or PPI, scans, the KASACR uses range height indicator, or RHI, scans at numerous azimuths to obtain cloud volume data. Measurements collected with the KASACR are copolar and cross-polar radar reflectivity, Doppler velocity, spectra width and spectra when not scanning, and linear depolarization ratio. KASACR data from the 2018–2019 Cloud, Aerosol, and Complex Terrain Interactions (CACTI) field campaign in Argentina are now available as b1-level products. Building on the original CACTI operational data, the b1-level products feature improved data quality resulting from extensive analyses and corrections. The data are cross-calibrated to a common point, datastreams are corrected for operational issues that occurred during the campaign, and several data quality masks and basic derived products are incorporated. For more information, read the CACTI radar b1-level processing report.

54 ENVIRONMENTAL SCIENCES↗

kasacr2cfrspccwrhicross (a1)

The Ka-Band Scanning ARM Cloud Radar (KASACR) records cloud properties. ARM's scanning cloud radars are dual-frequency, dual-polarization Doppler radars mounted on a common scanning pedestal. Each pedestal includes a Ka-band radar (2kW peak power) and the deployment location determines whether the second radar is a W-band (1.7 kW peak power) or an X-band (20 kW peak power). Beamwidths for Ka-bands paired with W-bands are roughly matched at 0.3 degrees. The X-band beamwidth is approximately 1 degree. Due to the narrow antenna beamwidth, ARM’s scanning cloud radars use scanning strategies unlike typical weather radars. Rather than focusing on plan position indicator, or PPI, scans, the KASACR uses range height indicator, or RHI, scans at numerous azimuths to obtain cloud volume data. Measurements collected with the KASACR are copolar and cross-polar radar reflectivity, Doppler velocity, spectra width and spectra when not scanning, and linear depolarization ratio. KASACR data from the 2018–2019 Cloud, Aerosol, and Complex Terrain Interactions (CACTI) field campaign in Argentina are now available as b1-level products. Building on the original CACTI operational data, the b1-level products feature improved data quality resulting from extensive analyses and corrections. The data are cross-calibrated to a common point, datastreams are corrected for operational issues that occurred during the campaign, and several data quality masks and basic derived products are incorporated. For more information, read the CACTI radar b1-level processing report.

54 ENVIRONMENTAL SCIENCES↗