Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Monte Carlo Sampling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 883 records · Page 49

Fossil Fuel Emission Verification Modeling at LLNL

We have an established project at LLNL to develop the tools needed to constrain fossil fuel carbon dioxide emissions using measurements of the carbon-14 isotope in atmospheric samples. In Figure 1 we show the fossil fuel plumes from Los Angeles and San Francisco for two different weather patterns. Obviously, a measurement made at any given location is going to depend on the weather leading up to the measurement. Thus, in order to determine the GHG emissions from some region using in situ measurements of those GHGs, we use state-of-the-art global and regional atmospheric chemistry-transport codes to simulate the plumes: the LLNL-IMPACT model (Rotman et al., 2004) and the WRFCHEM community code (http://www.wrf-model.org/index.php). Both codes can use observed (aka assimilated) meteorology in order to recreate the actual transport that occurred. The measured concentration of each tracer at a particular spatio-temporal location is a linear combination of the plumes from each region at that location (for non-reactive species). The challenge is to calculate the emission strengths for each region that fit the observed concentrations. In general this is difficult because there are errors in the measurements and modeling of the plumes. We solve this inversion problem using the strategy illustrated in Figure 2. The Bayesian Inference step combines the a priori estimates of the emissions, and their uncertainty, for each region with the results of the observations, and their uncertainty, and an ensemble of model predicted plumes for each region, and their uncertainty. The result is the mathematical best estimate of the emissions and their errors. In the case of non-linearities, or if we are using a statistical sampling technique such as a Markov Chain Monte Carlo technique, then the process is iterated until it converges (ie reaches stationarity). For the Bayesian inference we can use both a direct inversion capability, which is fast but requires assumptions of linearity and Gaussianity of errors, or one of several statistical sampling techniques, which are computationally slower but do not require either linearity or Gaussianity (Chow, et al., 2008; Delle Monache, et al., 2008). The emission regions we are using are based on the air-basins defined by the California Air Resources Board (CARB), see Figure 3. The only difference is that we have joined some of the smaller air basins together. The results of a test using 4 days of simulated observations using our ensemble retrieval system are shown in Figure 3 (right). The main source of the variation between the different model configurations arises from the uncertainty in the atmospheric boundary layer parameterization in the WRF model. We are currently developing a capability to constrain the boundary layer height in our carbon-14 work either by weighting the ensemble member results by the accuracy of their boundary layer height (using commercial aircraft observations), or as part of the retrieval process using an ensemble Kalman filter (EnKF) capability.

54 ENVIRONMENTAL SCIENCES↗

On Presolar Stardust Grains from CO Classical Novae

About 30%–40% of classical novae produce dust 20–100 days after the outburst, but no presolar stardust grains from classical novae have been unambiguously identified yet. Although several studies claimed a nova paternity for certain grains, the measured and simulated isotopic ratios could only be reconciled, assuming that the grains condensed after the nova ejecta mixed with a much larger amount of close-to-solar matter. However, the source and mechanism of this potential post-explosion dilution of the ejecta remains a mystery. A major problem with previous studies is the small number of simulations performed and the implied poor exploration of the large nova parameter space. In this paper, we report the results of a different strategy, based on a Monte Carlo technique, that involves the random sampling over the most important nova model parameters: the white dwarf composition; the mixing of the outer white dwarf layers with the accreted material before the explosion; the peak temperature and density; the explosion timescales; and the possible dilution of the ejecta after the outburst. We discuss and take into account the systematic uncertainties for both the presolar grain measurements and the simulation results. Only those simulations that are consistent with all measured isotopic ratios of a given grain are accepted for further analysis. We also present the numerical results of the model parameters. Lastly, we identify 18 presolar grains with measured isotopic signatures consistent with a CO nova origin, without assuming any dilution of the ejecta. Among these, the grains G270_2, M11-334-2, G278, M11-347-4, M11-151-4, and Ag2_6 have the highest probability of a CO nova paternity.

nuclear reactions↗

Evaluation of Jacobian determinants by Monte Carlo methods - Application to the quasiclassical approximation in molecular scattering.

Sampling techniques have been used previously to evaluate Jacobian determinants that occur in classical mechanical descriptions of molecular scattering. These determinants also occur in the quasiclassical approximation. A new technique is described which can be used to evaluate Jacobian determinants which occur in either description. This method is expected to be valuable in the study of reactive scattering using the quasiclassical approximation.

La Budde, R. A.↗

The intrinsic luminosity and initial period of pulsars

The observed properties of pulsars are modeled on the assumption that they evolve by emitting magnetic dipole radiation and have exponentially decaying magnetic fields. The models are constructed by using Monte Carlo techniques to generate a Galactic sample of pulsars having particular distributions of initial periods, magnetic dipole moments, and positions. By choosing a relationship between the radio luminosity L(r), the period (P), and the P derivative, it is determined which pulsars of the generated sample could be detected by one of the major pulsar surveys. Detailed account is taken of known selection effects in these surveys. Models in which the size of the pulsar emission cone is dependent on the period are considered. The properties of the detectable pulsars are compared with the properties of the observed pulsars, and the initial distributions and luminosity relation of the model are adjusted until a satisfactory agreement is obtained. A crucial point is that the observed relation between L(r) and P, P derivative is affected by selection effects and does not apply to the actual pulsar population. It is found that the best fits are obtained with models in which the pulsars are injected with relatively long periods, about 0.5 sec.

Emmering, Robert T.↗

Global SUSY fits

Explore the source record for details and available documents.

2D SCANS↗

Testing Different Methods for Estimating Uncertainties on Rietveld Refined Parameters Using SrRietveld

The advent of fast computing allows more computationally expensive, though possibly more accurate, approaches for estimating uncertainties on Rietveld refined parameters. Here we compare three such methods, using two different refinement programs, FullProf and GSAS. This is facilitated by the use of a new Rietveld refinement package, SrRietveld, that provides Python wrappers for FullProf and GSAS. The refined values on the parameters from two different refinement engines match each other very well. The uncertainty estimates determined using the different methods are also consistent, though FullProf and GSAS estimate the parameter uncertainties slightly differently from each other, which is discussed. More importantly, we find that the refined results are very sensitive to the statistical weights used in the least squares equation. Different weights, for example from uncertain or incorrectly propagated random errors on the data, lead to significantly different refined values. This means that uncertainty estimates on refined parameters should be increased when the random errors on the data are not well known, as for example in many cases where area detectors are used, and care should be taken to propagate errors correctly in any data preprocessing such as normalization by a smoothed spectrum. The computationally expensive bootstrap error estimation methods are facilitated by the use of SrRietveld, but are not required in most cases though may be useful in some cases, for example if the random errors on the data are not well known.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Determining the bubble nucleation efficiency of low-energy nuclear recoils in superheated C$_3$F$_8$ dark matter detectors

The bubble nucleation efficiency of low-energy nuclear recoils in superheated liquids plays a crucial role in interpreting results from direct searches for weakly interacting massive particle (WIMP) dark matter. The PICO Collaboration presents the results of the efficiencies for bubble nucleation from carbon and fluorine recoils in superheated C$_3$F$_8$ from calibration data taken with 5 distinct neutron spectra at various thermodynamic thresholds ranging from 2.1 keV to 3.9 keV. Instead of assuming any particular functional forms for the nuclear recoil efficiency, a generalized piecewise linear model is proposed with systematic errors included as nuisance parameters to minimize model-introduced uncertainties. A Markov-Chain Monte-Carlo (MCMC) routine is applied to sample the nuclear recoil efficiency for fluorine and carbon at 2.45 keV and 3.29 keV thermodynamic thresholds simultaneously. The nucleation efficiency for fluorine was found to be $\geq 50\, \%$ for nuclear recoils of 3.3 keV (3.7 keV) at a thermodynamic Seitz threshold of 2.45 keV (3.29 keV), and for carbon the efficiency was found to be $\geq 50\, \%$ for recoils of 10.6 keV (11.1 keV) at a threshold of 2.45 keV (3.29 keV). Simulated data sets are used to calculate a p-value for the fit, confirming that the model used is compatible with the data. The fit paradigm is also assessed for potential systematic biases, which although small, are corrected for. Additional steps are performed to calculate the expected interaction rates of WIMPs in the PICO-60 detector, a requirement for calculating WIMP exclusion limits.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Hadron spectroscopy of pseudoscalar and vector meson photoproduction using linearly polarised photons at CLAS

The field of hadron spectroscopy is informed by experiments which study excited states of the nucleon by detecting the decay products following excitation with a hadronic, leptonic or electromagnetic probe. Experiments using a polarised beam of photons provide an important contribution to the world data. This thesis describes the analysis of data from one such experiment, the CEBAF Large Acceptance Spectrometer at Jefferson Laboratory, Virginia, USA. In the experiment, an incident beam of electrons passes through a diamond radiator producing a linearly polarised photon beam of energy from 1.1 to 2.1 GeV on a liquid hydrogen target. The analysis method and results for two reaction channels are presented. In the first analysis, the polarisation observables {?, P, T, Ox, Oz} for the reaction ??? p ? K0 S ?+ are extracted simultaneously using likelihood sampling with Markov-Chain Monte-Carlo. The results are presented as angular distributions (cos ?K0S) for bins in photon energy E? for a total of 21 bins. The values extracted for T , Ox and Oz are a first measurement of these quantities for this reaction and the beam asymmetry (?) measurement supplements the one previous measurement for this quantity and extends the energy range over which it has been extracted. The measurement of the recoil polarisation, P, is consistent with previous measurements. In a second analysis, the spin density matrix elements (SDMEs) for ? p ? p ? are extracted using similar analysis techniques. The results are presented as angular distributions (cos ?? ) for bins in photon energy E? for a total of 24 bins. This work is the first to extract all nine SDMEs for the full angular range of the ? meson production. A comparison is made to the predictions of the Vector Meson Dominance (VMD) model and the results provide evidence for contributing processes other than VMD, particularly at more backward angles of the ? meson production. The data also indicate non-helicity conserving process in both the s-channel and the t-channel. The results from the first analysis have been passed to the Juelich-Bonn theory group and the effect of including the new data within their dynamical coupled channel model is described. Several nucleon resonances are affected and the impact on the pole positions, widths and photon decay amplitudes of the affected resonances is described.

Clark, Louise↗

Dimuon production in the MicroBooNE detector

This analysis studies the production of the rare signal with two muons (dimuon) in the finalstate at µB using the Booster Neutrino Beam (BNB) as source of neutrino interactions. Themain background source for the dimuon signal are pions. Differentiating muons and pions hasbeen challenging at µB because the tracks left by these particles are almost identical. Thisanalysis faces this problem using a supervised classifier algorithm called boosted decisiontree (BDT). A Monte Carlo simulation (MC) enhanced dimuon signal sample was producedto train a BDT capable of recognizing this signal. A set of variables that show somediscrimination characteristics was used to perform the training. A MC neutrino interactionsimulation sample was used to estimate the background. Estimations of dimuon productionin real data samples were made for different cases. Additionally, an analysis of the systematicuncertainties, fake data studies, and BDT performance checks were obtained.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Heating of the moon by heterogeneous accretion

Monte Carlo models of lunar accretion are developed by randomly sampling mass and velocity distributions of objects in the solar nebula in circumsolar and circumterrestrial orbits. The thermal effect of an impact is expressed as the volume of melt produced; the melt volumes produced by each Monte Carlo case are sorted into regions to produce percentage melt estimates as a function of radius. One-hundred cases are calculated to obtain a range of plausible thermal histories for lunar accretion. The average melt percentage estimates show substantial deep melting, but the spread of melt percentage values about the mean from the random sampling procedure is wide enough to include 0% melting for radii below 100 km and 100% melting for radii below 500 km.

Ransford, G. A.↗

Multi-fidelity microstructure-induced uncertainty quantification by advanced Monte Carlo methods

Quantifying uncertainty associated with the microstructure variation of a material can be a computationally daunting task, especially when dealing with advanced constitutive models and fine mesh resolutions in the crystal plasticity finite element method (CPFEM). Numerous studies have been conducted regarding the sensitivity of material properties and performance to the mesh resolution and choice of constitutive model. However, a unified approach that accounts for various fidelity parameters, such as mesh resolutions, integration time-steps and constitutive models simultaneously is currently lacking. Further, this paper proposes a novel uncertainty quantification (UQ) approach for computing the properties and performance of homogenized materials using CPFEM, that exploits a hierarchy of approximations with different levels of fidelity. In particular, we illustrate how multi-level sampling methods, such as multi-level Monte Carlo (MLMC) and multi-index Monte Carlo (MIMC), can be applied to assess the impact of variations in the microstructure of polycrystalline materials on the predictions of homogenized materials properties. We show that by adaptively exploiting the fidelity hierarchy, we can significantly reduce the number of microstructures required to reach a certain prescribed accuracy. Finally, we show how our approach can be extended to a multi-fidelity framework, where we allow the underlying constitutive model to be chosen from either a phenomenological plasticity model or a dislocation-density-based model.

36 MATERIALS SCIENCE↗

Multicanonical sampling of rare events in random matrices

A method based on multicanonical Monte Carlo is applied to the calculation of large deviations in the largest eigenvalue of random matrices. The method is successfully tested with the Gaussian orthogonal ensemble, sparse random matrices, and matrices whose components are subject to uniform density. Specifically, the probability that all eigenvalues of a matrix are negative is estimated in these cases down to the values of {approx}10{sup -200}, a region where simple random sampling is ineffective. The method can be applied to any ensemble of matrices and used for sampling rare events characterized by any statistics.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Collimator design for a multipinhole brain SPECT insert for MRI

Purpose: Brain single photon emission computed tomography (SPECT) imaging is an important clinical tool, with unique tracers for studying neurological diseases. Nowadays, most commercial SPECT systems are combined with x-ray computed tomography (CT) in so-called SPECT/CT systems to obtain an anatomical background for the functional information. However, while CT images have a high spatial resolution, they have a low soft-tissue contrast, which is an important disadvantage for brain imaging. Magnetic resonance imaging (MRI), on the other hand, has a very high soft-tissue contrast and does not involve extra ionizing radiation. Therefore, the authors designed a brain SPECT insert that can operate inside a clinical MRI. Methods: The authors designed and simulated a compact stationary multipinhole SPECT insert based on digital silicon photomultiplier detector modules, which have shown to be MR-compatible and have an excellent intrinsic resolution (0.5 mm) when combined with a monolithic 2 mm thick LYSO crystal. First, the authors optimized the different parameters of the SPECT system to maximize sensitivity for a given target resolution of 7.2 mm in the center of the field-of-view, given the spatial constraints of the MR system. Second, the authors performed noiseless simulations of two multipinhole configurations to evaluate sampling and reconstructed resolution. Finally, the authors performed Monte Carlo simulations and compared the SPECT insert with a clinical system with ultrahigh-resolution (UHR) fan beam collimators, based on contrast-to-noise ratio and a visual comparison of a Hoffman phantom with a 9 mm cold lesion. Results: The optimization resulted in a stationary multipinhole system with a collimator radius of 150.2 mm and a detector radius of 172.67 mm, which corresponds to four rings of 34 diSPM detector modules. This allows the authors to include eight rings of 24 pinholes, which results in a system volume sensitivity of 395 cps/MBq. Noiseless simulations show sufficient axial sampling (in a Defrise phantom) and a reconstructed resolution of 5.0 mm (in a cold-rod phantom). The authors compared the 24-pinhole setup with a 34-pinhole system (with the same detector radius but a collimator radius of 156.63 mm) and found that 34 pinholes result in better uniformity but a worse reconstruction of the cold-rod phantom. The authors also compared the 24-pinhole system with a clinical triple-head UHR fan beam system based on contrast-to-noise ratio and found that the 24-pinhole setup performs better for the 6 mm hot and the 16 mm cold lesions and worse for the 8 and 10 mm hot lesions. Finally, the authors reconstructed noisy projection data of a Hoffman phantom with a 9 mm cold lesion and found that the lesion was slightly better visible on the multipinhole image compared to the fan beam image. Conclusions: The authors have optimized a stationary multipinhole SPECT insert for MRI and showed the feasibility of doing brain SPECT imaging inside a MRI with an image quality similar to the best clinical SPECT systems available.

60 APPLIED LIFE SCIENCES↗

A Comparison of the FW-CADIS and MR-CADIS Variance Reduction Methods

The Consistent Adjoint Driven Importance Sampling (CADIS) method, which uses an adjoint deterministic estimate for making variance reduction parameters that optimize Monte Carlo (MC) shielding calculations, was introduced in 1998. This method was designed to optimize a single tally, typically an integrated response such as a detector count rate or a dose rate. Because both deterministic and stochastic methods are employed, CADIS is referred to as a hybrid method. In 2007, the forward-weighted CADIS (FW-CADIS) method was introduced to optimize several tallies at once, giving more uniform relative uncertainties among the tallies for both high-flux and low-flux areas of the problem. This method can be used for several small detectors, for semi-global problems (mesh tally over a large fraction of the problem), or for global problems (mesh tally over the entire problem). Optimization can be done for an integrated response such as a dose rate D(r) as a function of position, the total flux {phi}(r) as a function of position, or the space/energy flux {phi}(r,E). Both the CADIS and FW-CADIS methods have been in the MAVRIC sequence of SCALE for three versions (6.0 in 2009, 6.1 in 2011, and 6.2 in 2016). The ADVANTG package released in 2015 uses the CADIS and FW-CADIS methods to accelerate MCNP neutron/photon shielding calculations. In 2014, the multi-response CADIS (MR-CADIS) method was presented as a way to obtain even more uniform relative uncertainties for problems with multiple tallies than those obtained with FW-CADIS. The method does not use a forward deterministic calculation but instead uses one adjoint calculation for every tally to be optimized in the Monte Carlo calculation. This work compares the above methods.

42 ENGINEERING↗

DEVELOPING ATMOSPHERIC RETRIEVAL METHODS FOR DIRECT IMAGING SPECTROSCOPY OF GAS GIANTS IN REFLECTED LIGHT. I. METHANE ABUNDANCES AND BASIC CLOUD PROPERTIES

Upcoming space-based coronagraphic instruments in the next decade will perform reflected light spectroscopy and photometry of cool directly imaged extrasolar giant planets. We are developing a new atmospheric retrieval methodology to help assess the science return and inform the instrument design for such future missions, and ultimately interpret the resulting observations. Our retrieval technique employs a geometric albedo model coupled with both a Markov chain Monte Carlo Ensemble Sampler ( emcee ) and a multimodal nested sampling algorithm ( MultiNest ) to map the posterior distribution. This combination makes the global evidence calculation more robust for any given model and highlights possible discrepancies in the likelihood maps. As a proof of concept, our current atmospheric model contains one or two cloud layers, methane as a major absorber, and a H{sub 2}–He background gas. This 6-to-9 parameter model is appropriate for Jupiter-like planets and can be easily expanded in the future. In addition to deriving the marginal likelihood distribution and confidence intervals for the model parameters, we perform model selection to determine the significance of methane and cloud detection as a function of expected signal-to-noise ratio in the presence of spectral noise correlations. After internal validation, the method is applied to realistic spectra of Jupiter, Saturn, and HD 99492c, a model observing target. We find that the presence or absence of clouds and methane can be determined with high confidence, while parameter uncertainties are model dependent and correlated. Such general methods will also be applicable to the interpretation of direct imaging spectra of cloudy terrestrial planets.

79 ASTRONOMY AND ASTROPHYSICS↗

Comparison of ADVANTG Simulations to Simple Shielding Measurements - Paper 36

Monte Carlo (MC) radiation transport simulations, like those performed using Monte Carlo N-Particle (MCNP), can be highly accurate but require time to reduce the statistical uncertainties in the calculated detector response(s). Many different 'variance reduction' techniques devised over the years increase the efficiency of MC calculations, but these methods can be more art than science. Many of these methods are problem specific or require careful tuning of parameters for good performance. One of the best variance reduction methods, in terms of both reliable performance increases and ease of use, is the use of weight windows. Weight windows are derived from an importance map in space and energy that allows the transport code to focus more simulation time on particles that have a higher likelihood of being important to the final detector response. Less time is spent simulating particles that have little chance of making a contribution to the detector response. MCNP already includes the abilities to generate and use weight windows. Unfortunately, generating weight windows can take a very long time, perhaps longer than the original problem. Oak Ridge National Laboratory has led the development of hybrid methods using a discrete ordinates adjoint calculation to quickly develop an importance map (weight windows) for use in a Monte Carlo code. The Consistent Adjoint Driven Importance Sampling (CADIS) method uses an adjoint calculation to develop both an importance map and a biased source distribution that work together. This method is reasonably automatic, is easy to use, and has been implemented in the Automated Variance reduction Generator (ADVANTG) package that works with MCNP5. ADVANTG reads an MCNP input file and a small amount of extra user information and then runs an adjoint deterministic calculation using Denovo. The importance map and biased source distribution derived from the CADIS method can then be incorporated back into the original MCNP input file to enhance the figure-of-merit (FOM) of the calculation. The FOM is a measure of the efficiency of the calculation using the amount of run time and corresponding level of statistical uncertainty in the detector result. ADVANTG-enhanced MCNP input files have been shown to increase the FOM of many types of problems, obtaining the same level of statistical uncertainty in a shorter time compared to standard MCNP. ADVANTG can also generate variance reduction parameters (importance map and biased source) using the Forward-Weighted CADIS (FW-CADIS) method for optimizing mesh tallies. The CADIS method creates variance reduction parameters that optimize a tally's total quantity (flux, dose rate, interaction rate, etc.) and will not generally increase performance for all parts of a segmented tally. To optimize a segmented tally, the FW-CADIS method uses two discrete ordinates calculations to make variance reduction parameters that help compute a segmented tally with uniform relative uncertainties in each bin. This report will demonstrate that using ADVANTG for neutron and photon radiation shielding problems will (1) preserve the standard MCNP results and (2) obtain those results either with less statistical uncertainty or in shorter times than the standard MCNP calculation. The four demonstration problems in this report are based on simple neutron or photon transmission measurements through different materials. All of the problems here used the CADIS method and still saw improvement across the flux tallies segmented by particle energy. (authors)

61 RADIATION PROTECTION AND DOSIMETRY↗

MEASURING X-RAY VARIABILITY IN FAINT/SPARSELY SAMPLED ACTIVE GALACTIC NUCLEI

We study the statistical properties of the normalized excess variance of variability process characterized by a ''red-noise'' power spectral density (PSD), as in the case of active galactic nuclei (AGNs). We perform Monte Carlo simulations of light curves, assuming both a continuous and a sparse sampling pattern and various signal-to-noise ratios (S/Ns). We show that the normalized excess variance is a biased estimate of the variance even in the case of continuously sampled light curves. The bias depends on the PSD slope and on the sampling pattern, but not on the S/N. We provide a simple formula to account for the bias, which yields unbiased estimates with an accuracy better than 15%. We show that the normalized excess variance estimates based on single light curves (especially for sparse sampling and S/N < 3) are highly uncertain (even if corrected for bias) and we propose instead the use of an ''ensemble estimate'', based on multiple light curves of the same object, or on the use of light curves of many objects. These estimates have symmetric distributions, known errors, and can also be corrected for biases. We use our results to estimate the ability to measure the intrinsic source variability in current data, and show that they could also be useful in the planning of the observing strategy of future surveys such as those provided by X-ray missions studying distant and/or faint AGN populations and, more in general, in the estimation of the variability amplitude of sources that will result from future surveys such as Pan-STARRS and LSST.

79 ASTRONOMY AND ASTROPHYSICS↗

Accelerated radiation transport modeling techniques for pencil beam computed tomography using gamma rays

Monte Carlo radiation transport modeling studies were performed for a compact, and high-resolution gamma-ray computed tomography system designed for imaging irradiated nuclear fuel. The system comprises a 60 Co source – chosen for its highly penetrating 1173 keV and 1332 keV gamma rays – a pair of high-aspect-ratio pencil beam collimators, and an inorganic scintillator detector. Here two acceleration methods are proposed to rapidly model a transmission type gamma-ray tomography system. The first, a variance reduction technique, is based on performing Monte Carlo simulations with a monodirectionally-biased source, sampled from a characteristic sub-volume of the full source volume. The second acceleration method is based on the deterministic calculations using the Beer–Lambert law and detector response characteristics. Comparison of simulations using acceleration approaches with analog simulations of the fully isotropic, full-volume equivalent, show that the Monte Carlo variance reduction technique gives quantitatively accurate predictions for large collimator aspect ratios while the deterministic calculations are semi-quantitative but converge close to the correct result as the collimator aspect ratio increases. As such, these techniques can be used to reduce the computational cost in generating simulated radiographs and tomographs by several orders of magnitude. Experimental validation efforts are currently underway and will be demonstrated in future work.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗