Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Monte Carlo Method”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 883 records · Page 49

Sci—Thur PM: Planning and Delivery — 03: Automated delivery and quality assurance of a modulated electron radiation therapy plan

Modulated electron radiation therapy (MERT) offers the potential to improve healthy tissue sparing through increased dose conformity. Challenges remain, however, in accurate beamlet dose calculation, plan optimization, collimation method and delivery accuracy. In this work, we investigate the accuracy and efficiency of an end-to-end MERT plan and automated-delivery workflow for the electron boost portion of a previously treated whole breast irradiation case. Dose calculations were performed using Monte Carlo methods and beam weights were determined using a research-based treatment planning system capable of inverse optimization. The plan was delivered to radiochromic film placed in a water equivalent phantom for verification, using an automated motorized tertiary collimator. The automated delivery, which covered 4 electron energies, 196 subfields and 6183 total MU was completed in 25.8 minutes, including 6.2 minutes of beam-on time with the remainder of the delivery time spent on collimator leaf motion and the automated interfacing with the accelerator in service mode. The delivery time could be reduced by 5.3 minutes with minor electron collimator modifications and the beam-on time could be reduced by and estimated factor of 2–3 through redesign of the scattering foils. Comparison of the planned and delivered film dose gave 3%/3 mm gamma pass rates of 62.1, 99.8, 97.8, 98.3, and 98.7 percent for the 9, 12, 16, 20 MeV, and combined energy deliveries respectively. Good results were also seen in the delivery verification performed with a MapCHECK 2 device. The results showed that accurate and efficient MERT delivery is possible with current technologies.

60 APPLIED LIFE SCIENCES↗

Thermal ionization of helium in the quantum mechanical representation of Feynman path integrals

The method of Feynman path integrals is used to calculate the degree of ionization in a thermodynamically equilibrium, dense helium plasma. A quantum statistical calculation which is based on the 'first principles' and in which the permutation symmetry and electron spin variable are explicitly taken into account is carried out for a helium atom that is in thermal and mechanical contact with a plasma at a temperature from 30000 to 400000 K. Numerical integration over virtual paths is performed by the Monte Carlo method. When the temperature and density are varied, the amount of singly charged ions in a plasma varies nonmonotonically, reaching a maximum at a temperature of about 70 000 K and a pressure of 100 MPa. Radial profiles of the electron density around a helium nucleus are obtained, as well as contour lines of the degree of ionization in the p-T plane of the plasma states. The role of fluctuations is investigated. It is shown that the fluctuations of the local electron density near a helium ion have a radical effect on the values of the ionization-recombination equilibrium constants.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Comparative Study of Algorithms for the Numerical Simulation of Lattice QCD

Large-scale numerical simulations are the prime method for a nonperturbative study of QCD from first principles. Although the lattice simulation of the pure-gauge (or quenched-QCD) case may be performed very efficiently on parallel machines, there are several additional difficulties in the simulation of the full-QCD case, i.e. when dynamical quark effects are taken into account. We discuss the main aspects of full-QCD simulations, describing the most common algorithms. We present a comparative analysis of performance for two versions of the hybrid Monte Carlo method (the so-called R and RHMC algorithms), as provided in the MILC software package. We consider two degenerate flavors of light quarks in the staggered formulation, having in mind the case of finite-temperature QCD.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Experimental and theoretical study of the near IR emission of xenon excited by a fast electron beam

Emission of xenon excited by a 120-keV electron beam at gas pressures of 100, 200, 500, and 760 Torr nm was studied experimentally and theoretically. More than 30 spectral lines were identified in the wavelength range of 750–1000 nm. A self-consistent kinetic model is developed to calculate the emission intensity of xenon atoms in the near IR range. The model includes balance equations for the number densities of electrons, ions and excimer molecules; equations for the populations of electron levels; and the Boltzmann equation for the low-energy part of the electron energy distribution function with a source of slow electrons. Excitation and ionization rates of xenon by the beam electrons and the energy spectrum of slow electrons are calculated by the Monte Carlo method. It is shown that, under these conditions, the main mechanism of xenon atom excitation is dissociative recombination of Xe{sub 3}{sup +} ions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

CT energy weighting in the presence of scatter and limited energy resolution

Purpose: Energy-resolved CT has the potential to improve the contrast-to-noise ratio (CNR) through optimal weighting of photons detected in energy bins. In general, optimal weighting gives higher weight to the lower energy photons that contain the most contrast information. However, low-energy photons are generally most corrupted by scatter and spectrum tailing, an effect caused by the limited energy resolution of the detector. This article first quantifies the effects of spectrum tailing on energy-resolved data, which may also be beneficial for material decomposition applications. Subsequently, the combined effects of energy weighting, spectrum tailing, and scatter are investigated through simulations. Methods: The study first investigated the effects of spectrum tailing on the estimated attenuation coefficients of homogeneous slab objects. Next, the study compared the CNR and artifact performance of images simulated with varying levels of scatter and spectrum tailing effects, and reconstructed with energy integrating, photon-counting, and two optimal linear weighting methods: Projection-based and image-based weighting. Realistic detector energy-response functions were simulated based on a previously proposed model. The energy-response functions represent the probability that a photon incident on the detector at a particular energy will be detected at a different energy. Realistic scatter was simulated with Monte Carlo methods. Results: Spectrum tailing resulted in a negative shift in the estimated attenuation coefficient of slab objects compared to an ideal detector. The magnitude of the shift varied with material composition, increased with material thickness, and decreased with photon energy. Spectrum tailing caused cupping artifacts and CT number inaccuracies in images reconstructed with optimal energy weighting, and did not impact images reconstructed with photon counting weighting. Spectrum tailing did not significantly impact the CNR in reconstructed images. Scatter reduced the CNR for all energy-weighting methods; however, the effect was greater for optimal energy weighting. For example, optimal energy weighting improved the CNR of iodine and water compared to energy-integrating weighting by a factor of {approx}1.45 in the absence of scatter and by a factor of {approx}1.1 in the presence of scatter (8.9 deg. cone angle, SPR 0.5). Without scatter correction, the difference in CNR resulting from photon-counting and optimal energy weighting was negligible (<15%) for cone angles greater than 4.4 deg. (SPR>0.3). Optimal weights combined with deterministic scatter correction provided a 1.3 and 1.1 improvement in CNR compared to energy-integrating and photon-counting weighting, respectively, for the 8.9 deg. cone angle simulation. In the absence of spectrum tailing, image-based weighting demonstrated reduced cupping artifact compared to projection-based weighting; however, both weighting methods exhibited similar cupping artifacts when spectrum tailing was simulated. There were no statistically significant differences in the CNR resulting from projection and image-based weighting for any of the simulated conditions. Conclusions: Optimal linear energy weighting introduces artifacts and CT number inaccuracies due to spectrum tailing. While optimal energy weighting has the potential to improve CNR compared to conventional weighting methods, the benefits are reduced as scatter increases. Efficient methods for reducing scatter and correcting spectrum tailing effects are required to obtain the highest benefit from optimal energy weighting.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Two-photon fluorescence microscopy signal formation in highly scattering media: theoretical and numerical simulation

Using the radiative transfer theory and Monte Carlo simulations, we analyse the effect of scattering in a medium and of the size of the detector pinhole on the formation of the fluorescent signal in standard two-photon fluorescence microscopy (TPFM) systems. The theoretical analysis is based on a small-angle diffusion approximation of the radiative transfer equation, adapted to calculate the propagation of focused infrared radiation in media similar to the biological tissues in their optical properties. The accuracy of the model is evaluated by comparing the calculated excitation intensity in a highly scattering medium with the results of Monte Carlo simulations. To simulate a tightly focused Gaussian beam by the Monte Carlo method, the so called 'ray-optics' approach that correctly takes into account the finite size and shape of the beam waist is applied. It is shown that in the combined confocal and two-photon scanning microscopy systems not equipped with an external 'nondescanned' detector, the scattering significantly affects both the nonlinear excitation efficiency in the medium and the fluorescence collection efficiency of the system. In such systems, the rate of the useful TPFM signal in-depth decay is 1.5 - 2 times higher than in systems equipped with a 'nondescanned' detector. (application of lasers and laser-optical methods in life sciences)

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

SU-C-BRE-07: Sensitivity Analysis of the Threshold Energy for the Creation of Strand Breaks and of Single and Double Strand Break Clustering Conditions

Purpose: To analyse the sensitivity of the creation of strand breaks (SB) to the threshold energy (Eth) and thresholding method and to quantify the impact of clustering conditions on single strand break (SSB) and double strand break (DSB) yields. Methods: Monte Carlo simulations using Geant4-DNA were conducted for electron tracks of 280 eV to 220 keV in a geometrical DNA model composed of nucleosomes of 396 phospho-diester groups (PDGs) each. A strand break was created inside a PDG when the sum of all energy deposits (method 1) or energy transfers (method 2) was higher than Eth or when at least one interaction deposited (method 3) or transferred (method 4) an energy higher than Eth. SBs were then clustered into SSBs and DSBs using clustering scoring criteria from the literature and compared to our own. Results: The total number of SBs decreases as Eth is increased. In addition, thresholding on the energy transfers (methods 2 and 4) produces a higher SB count than when thresholding on energy deposits (methods 1 and 3). Method 2 produces a step-like function and should be avoided when attempting to optimize Eth. When SBs are grouped into damage patterns, clustering conditions can underestimated SSBs by up to 18 % and DSBs can be overestimated by up to 12 % compared to our own implementation. Conclusion: We show that two often underreported simulation parameters have a non-negligible effect on overall DNA damage yields. First more SBs are counted when using energy transfers to the PDG rather than energy deposits. Also, SBs grouped according to different clustering conditions can influence reported SSB and DSB by as much as 20%. Careful handling of these parameters is required when trying to compare DNA damage yields from different authors. Research funding from the governments of Canada and Quebec. PP acknowledges partial support by the CREATE Medical Physics Research Training Network grant of the Natural Sciences and Engineering Research Council (Grant number: 432290)

60 APPLIED LIFE SCIENCES↗

Brownian dynamics of confined rigid bodies

We introduce numerical methods for simulating the diffusive motion of rigid bodies of arbitrary shape immersed in a viscous fluid. We parameterize the orientation of the bodies using normalized quaternions, which are numerically robust, space efficient, and easy to accumulate. We construct a system of overdamped Langevin equations in the quaternion representation that accounts for hydrodynamic effects, preserves the unit-norm constraint on the quaternion, and is time reversible with respect to the Gibbs-Boltzmann distribution at equilibrium. We introduce two schemes for temporal integration of the overdamped Langevin equations of motion, one based on the Fixman midpoint method and the other based on a random finite difference approach, both of which ensure that the correct stochastic drift term is captured in a computationally efficient way. We study several examples of rigid colloidal particles diffusing near a no-slip boundary and demonstrate the importance of the choice of tracking point on the measured translational mean square displacement (MSD). We examine the average short-time as well as the long-time quasi-two-dimensional diffusion coefficient of a rigid particle sedimented near a bottom wall due to gravity. For several particle shapes, we find a choice of tracking point that makes the MSD essentially linear with time, allowing us to estimate the long-time diffusion coefficient efficiently using a Monte Carlo method. However, in general, such a special choice of tracking point does not exist, and numerical techniques for simulating long trajectories, such as the ones we introduce here, are necessary to study diffusion on long time scales.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

On choosing the order parameter of modulated magnetic structures

Long-period modulated structures in the anisotropic Ising model with competing interactions (the ANNNI model) are studied by Monte Carlo methods. A new order parameter in the form of modulated phase amplitude is proposed for describing modulated structures. It is shown that the properties of the modulated phase-paramagnetic phase transition can be investigated by using the amplitude as the order parameter.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Simulation of Experiment on Measurement of Neutron Lifetime Using the Big Gravitational Trap of Ultracold Neutrons with the Absorber

At present, the experiment on measuring neutron lifetime using a big gravitational trap is being performed at Petersburg Nuclear Physics Institute. It is planned to achieve a measurement precision of 0.2 s, which is four times better than the best existing level of precision. The modified installation is simulated using the Monte Carlo method. It has been shown that the application of the absorber in the installation design increases the number of stored ultracold neutrons in the trap by a factor of approximately three and reduces the duration of the measurement cycle.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Describing the Influence of Ball-milling on the Amorphization of Flubendazole Using the PDF and RMC Methods with X-ray Powder Diffraction Data

Flubendazole (FBZ) is a poorly water-soluble drug, and different methodologies have been proposed to improve its oral bioavailability. Obtaining the amorphous drug phase is an alternative to improve its water solubility. Several techniques for drug amorphization, such as spray drying, lyophilization, melt quenching, solvent-evaporation, and ball milling, can yield various types of structural disorder and possibly render variations in physicochemical properties. Herein, we focus on evaluating the influence of the ball-milling process on the amorphization of FBZ. The characterization of the average global and local structures before, during, and after the milling process is described by sequential Rietveld refinements, pair distribution function analysis, and the Reverse Monte Carlo method. In conclusion, we show that preserving the local structure (nearest molecules) can be responsible for avoiding the fast structure recrystallization commonly observed when using the solvent-evaporation process for the studied drug.

60 APPLIED LIFE SCIENCES↗

Neutron flux measurement using activated radioactive isotopes at the Baksan underground scintillation telescope

Preliminary results of a neutron background measurement at the Baksan underground scintillation telescope (BUST) are presented. The external planes of the BUST are fully covered with standard scintillation detectors shielding the internal planes and suppressing thus background events due to cosmogenic and local radioactivity. The shielded internal planes were used as target for the neutron flux registration. The experimental method is based on the delayed coincidences between signals from any of the BUST counters. It is assumed that the first signal is due to inelastic interaction of a neutron with the organic scintillator, while the second signal comes from the decay of an unstable radioactive isotope formed when the fast neutron interacts with the {sup 12}C nuclei. Using the Monte-Carlo method (GEANT4) we also simulated propagation of neutrons through a layer of scintillator. The experimentally found muon induced neutron flux is j =1.3{sup +0.7}{sub -0.3} ×10{sup -10}cm{sup -2}s{sup -1} for neutron energies E ≥ 22MeV, which is in a qualitative agreement with similar measurements of other underground laboratories as well as with predictions of the GEANT4.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Estimation of proton distribution by means of three-dimensional reconstruction of prompt gamma rays

In proton therapy, the dose distribution of proton beams in the human body needs to be measured accurately. The distribution of prompt gamma rays emitted from patients during irradiation is strongly associated with the dose distribution of the proton beam. The (three-dimensional) 3D distribution of the prompt gamma rays detected by a single photon emission computed tomography was simulated using a Monte Carlo method. The 3D distribution of the prompt gamma rays was well matched with the dose distribution of the proton beam and was superior to the (two-dimensional) distribution of the prompt gamma rays detected using a conventional gamma camera.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Studies on Beam Formation in an Atomic Beam Source

Atomic beam sources (ABS) are widely used workhorses producing polarized atomic beams for polarized gas targets and polarized ion sources. Although they have been used for decades the understanding of the beam formation processes is crude. Models were used more or less successfully to describe the measured intensity and beam parameters. ABS's are also foreseen for future experiments, such as PAX [1]. An increase of intensity at a high polarization would be beneficial. A direct simulation Monte-Carlo method (DSMC)[2] was used to describe the beam formation of a hydrogen or deuterium beam in an ABS. For the first time a simulation of a supersonic gas expansion on a molecular level for this application was performed. Beam profile and Time-of-Flight measurements confirmed the simulation results. Furthermore a new method of beam formation was tested, the Carrier Jet method [3], based on an expanded beam surrounded by an over-expanded carrier jet.

43 PARTICLE ACCELERATORS↗

The Model of Decomposition of a Fe–Cu Alloy with Concentration-Depending Interatomic Interactions

The thermodynamics and kinetics of decomposition of a Fe–Cu alloy are investigated in the context of a simple ab initio parameterization model taking into account the concentration dependence of the magnetic contribution to the free energy. It is shown that taking into account a difference between the short-range and long-range magnetic orders near the Curie temperature is very important for calculating the solubility of copper in iron. The solubility of copper in bcc iron and the stability limit of a homogeneous state (physical spinodal) are evaluated via the kinetic Monte Carlo method. The impact of structural defects (dislocations and grain boundaries) on these curves, as well as on the kinetic time–temperature—transformation (TTT) diagram, is also discussed.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Optical and Kinetic Characteristics of an Atmospheric Pressure Pulsed Discharge in Helium with Iron Vapor

The emission spectrum of a near-cathode plasma of a pulsed discharge in atmospheric pressure helium reveals spectral lines of electrode material. Numerical simulation of the kinetics by the Monte Carlo method shows that starting with a fraction of percent, the addition of iron atoms to helium strongly affect the ionization-drift characteristics of electrons in gas.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Online quantitative analysis of multispectral images of human body tissues

A method is developed for online monitoring of structural and morphological parameters of biological tissues (haemoglobin concentration, degree of blood oxygenation, average diameter of capillaries and the parameter characterising the average size of tissue scatterers), which involves multispectral tissue imaging, image normalisation to one of its spectral layers and determination of unknown parameters based on their stable regression relation with the spectral characteristics of the normalised image. Regression is obtained by simulating numerically the diffuse reflectance spectrum of the tissue by the Monte Carlo method at a wide variation of model parameters. The correctness of the model calculations is confirmed by the good agreement with the experimental data. The error of the method is estimated under conditions of general variability of structural and morphological parameters of the tissue. The method developed is compared with the traditional methods of interpretation of multispectral images of biological tissues, based on the solution of the inverse problem for each pixel of the image in the approximation of different analytical models. (biomedical optics)

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Effect of a magnetic field in simulating the plume field of an anode layer Hall thruster

In this study, we present axisymmetric simulations of xenon plasma plume flow fields from a D55 anode layer Hall thruster. A hybrid particle-fluid method is used for the simulations. The magnetic field surrounding the Hall thruster exit is included in the calculation. The plasma properties obtained from a hydrodynamic model are used as boundary conditions for the simulations. The electron properties are calculated using the Boltzmann model and a detailed fluid model, collisions of heavy particle are modeled with the direct simulation Monte Carlo method, and ion transport in the electric field uses the particle-in-cell technique. The accuracy of the simulation is assessed through comparison with various measured data. It is found that a magnetic field significantly affects the profile of the plasma in the detailed model. The plasma has a potential of 80 V at 10 mm from the thruster exit in the case of zero magnetic field, which decreases to 60 V when the magnetic field is included. Results predicted by the detailed model with the magnetic field are found to be in better agreement with experimental data.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗