Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Microscopy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 883 records · Page 49

Single-particle detection of enhanced polarizability in Au-decorated semiconducting nanorods via scanning dielectric microscopy

Hybrid nanostructures that combine semiconducting and metallic components offer great potential for photothermal therapy, optoelectronics, and sensing, by integrating tunable optical properties with enhanced light absorption and charge transport. Boosting the integrated performance of these hybrid systems demands techniques capable of probing local variations of the physical properties inaccessible to bulk analysis. Here, we report the single-particle dielectric characterization of hybrid, semiconducting bismuth sulfide (Bi 2 S 3 ) nanorods (NR) decorated with metallic Au nanoparticles (NP), employing scanning dielectric microscopy, which uses electrostatic force microscopy in combination with finite-element numerical simulations. We reveal a pronounced enhancement in the local dielectric response of Bi2S3 upon Au decoration, attributed to interfacial polarization and electron transfer from Au to the Bi 2 S 3 matrix, thus suggesting a enhanced metallic-like polarizability at the single-particle level. Numerical simulations show that the response is dominated by the vertical component of the permittivity and that the decorating metallic Au NP produce only moderate shielding of the semiconductor Bi 2 S 3 NR core, indicating that the large increase in the dielectric response originates primarily from intrinsic modifications within the NR. Overall, these findings provide direct insight into structure–property relationships at the single-particle level, supporting the rational design of advanced hybrid nanostructures with tailored electronic functionalities.

36 MATERIALS SCIENCE↗

Unveiling Structural Heterogeneity and Imbalance of Gold Decahedral Nanoparticles using Four-dimensional Scanning Transmission Electron Microscopy

Multi-twinned structures have been observed in technologically important crystal systems, for example diamond cubic and face-centered cubic (FCC) lattices, that include materials such as diamond, silicon, a wide range of noble metals, and their nanoscale counterparts. Beyond atomic building blocks, the special arrangements also occur in the self-assembly of nanoparticles (NP) and μm-sized colloidal particles and occupy parts of their phase diagrams. Spanning a wide range of length scales, the universality of the structures arises when the systems attempt to achieve multitwinned structures by overcoming geometric misfits during minimizing surface energies with entirely {111} or close-packing facets. While it is fundamental to understand how strain is sustained upon twinned structures and symmetry breaking, the knowledge will be paramount in practical aspects such as guiding and controlling the thin film growth, anisotropic NP growth, and self-assembly of NPs. Au decahedral (Dh) NP, as the most prevalent multi-twinned model system, fits five tetrahedral motifs into a circle by sharing an axis resulting in a geometric misfit angle of 7.35°, or a disclination with power of -7.35°. Postulating how Au FCC lattice adopts the misfit, theoretical models have been developed to address the underlying lattice symmetry and inhomogeneous strain distribution separately. Yet, experimental reports regarding the former have been limited due to the relatively large X-ray beam sizes that do not fit the sizes of NPs. On the other hand, though the latter has been widely adapted in the thermodynamics of small (<10 nm) multi-twinned nanoparticles, previous literature has shown that, at edge length of 17 nm, the theory’s is invalidated by shear strain that is observed in a defect-free Au Dh NP by high-resolution transmission electron microscopy (HR-TEM) imaging. Though the advancement of aberrationcorrected scanning transmission electron microscopy (AC-STEM) imaging and ab initio calculation techniques brings new opportunities, along with challenges in complicated image analysis and limitation in particle size (usually below 10 nm), the gap between nanoscale and mesoscale has never been extended to gain insight from atomic system with straightforward interaction potentials.

4D-STEM↗

Rapid multidimensional data acquisition in scanning probe microscopy applied to local polarization dynamics and voltage dependent contact mechanics

A rapid multidimensional spectroscopic imaging approach in scanning probe microscopy is developed and applied to piezoresponse force spectroscopy. Evolution of resonance frequency, dissipation, and piezoresponse signal at each point during acquisition of local hysteresis loops provides information on polarization dynamics and voltage dependent contact mechanics of ferroelectric surfaces. The measurements illustrate significant frequency shifts during piezoresponse force spectroscopy, necessitating the use of frequency-tracking methods. The method is universal and can be extended to other scanning probe microscopy techniques. (C) 2008 American Institute of Physics.

Jesse, Stephen↗

Electrochemical strain microscopy with blocking electrodes: The role of electromigration and diffusion

Electrochemical strains are a ubiquitous feature of solid state ionic devices ranging from ion batteries and fuel cells to electroresistive and memristive memories. We proposed a scanning probe microscopy (SPM) based approach, referred as electrochemical strain microscopy (ESM), for probing local ionic flows and electrochemical reactions in solids based on bias-strain coupling. In ESM, the sharp SPM tip concentrates the electric field in a small (10-50 nm) region of material, inducing interfacial electrochemical processes and ionic flows. Furthermore, we use the resultant electrochemical strains to determine it from dynamic surface displacement and provide information on local electrochemical functionality. We also analyze image formation mechanism in ESM for a special case of mixed electronic-ionic conductor with blocking tip electrode, and determine frequency dependence of response, role of diffusion and electromigration effects, and resolution and detection limits.

36 MATERIALS SCIENCE↗

Half-harmonic Kelvin probe force microscopy with transfer function correction

An approach for surface potential imaging based on half-harmonic band excitation (BE) in Kelvin probe force microscopy is demonstrated. Using linear and half-harmonic BE enables quantitative correction of the cantilever transfer function. Half-harmonic band excitation Kelvin probe force microscopy (HBE KPFM) thus allows quantitative separation of surface potential and topographic contributions to the signal, obviating the primary sources of topographic cross-talk. HBE KPFM imaging and voltage spectroscopy methods are illustrated for several model systems.

Guo, Senli↗

Plasmon-Induced Optical Field Enhancement studied by Correlated Scanning and Photoemission Electron Microscopy

We use multi-photon photoemission electron microscopy (PEEM) to image the enhanced electric fields of silver nanoparticles supported on a silver thin film substrate. Electromagnetic field enhancement is measured by comparing the photoelectron yield of the nanoparticles with respect to the photoelectron yield of the surrounding silver thin film. We investigate the dependence of the photoelectron yield of the nanoparticle as a function of size and shape. Multi-photon PEEM results are presented for three average nanoparticle diameters: 122 ± 6, 75 ± 6, and 34 ± 2 nm. The enhancement in photoelectron yield of single nanoparticles illuminated with femtosecond laser pulses (400 nm, ~3.1 eV) is found to be a factor of 102 to 103 times greater than that produced by the flat silver thin film. High-resolution, multi-photon PEEM images of single silver nanoparticles reveal that the greatest enhancement in photoelectron yield is localized at distinct regions on the surface of the nanoparticle whose magnitude and spatial extent is dependent on the incident electric field polarization. In conjunction with correlated scanning electron microscopy (SEM), nanoparticles that deviate from nominally spherical shapes are found to exhibit irregular spatial distributions in the multi-photon PEEM images that are correlated with the unique shape and topology of the nanoparticle.

Environmental Molecular Sciences Laboratory↗

Intermodulation electrostatic force microscopy for imaging surface photo-voltage

We demonstrate an alternative to Kelvin Probe Force Microscopy for imaging surface potential. The open-loop, single-pass technique applies a low-frequency AC voltage to the atomic force microscopy tip while driving the cantilever near its resonance frequency. Frequency mixing due to the nonlinear capacitance gives intermodulation products of the two drive frequencies near the cantilever resonance, where they are measured with high signal to noise ratio. Analysis of this intermodulation response allows for quantitative reconstruction of the contact potential difference. We derive the theory of the method, validate it with numerical simulation and a control experiment, and we demonstrate its utility for fast imaging of the surface photo-voltage on an organic photo-voltaic material.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Characterization of LiMn 2 O 4 cathodes by electrochemical strain microscopy

Electrochemical strain microscopy (ESM) is a scanning probe microscopy(SPM) method in which the local electrodiffusion is probed via application of AC voltage to the SPM tip and registration of resulting electrochemical strain. In this study, we implemented ESM to measure local strain in bulk LiMn 2 O 4 cathodes of a commercial Li-battery in different states of charge to investigate distribution of Li-ion mobility and concentration. Ramped AC ESM imaging and voltage spectroscopy were used to find the most reliable regime of measurements allowing separating and diminishing different contributions to ESM. This is not a trivial task due to complex geometry of the sample and various obstacles resulting in less predictable contributions of different origins into ESM response: electrostatic tip–surface interactions, charge injection, electrostriction, and flexoelectricity. Finally, understanding and control of these contributions is an important step towards quantitative interpretation of ESM data.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

In situ dynamic transmission electron microscopy characterization of liquid-mediated crystallization of amorphous Ge

Crystal growth rates during laser-induced, liquid-mediated crystallization of amorphous Ge were measured with movie-mode dynamic transmission electron microscopy (MM-DTEM), a photoemission microscopy technique with nanosecond-scale time resolution. Films of 50-nm thick amorphous Ge were crystallized using a 12-ns laser pulse with a Gaussian spatial profile, which established high local temperature gradients in the specimen. Crystallization proceeded by the formation of a central zone with a high nucleation rate (zone I), followed by liquid-mediated outward growth of columnar grains (zone II), followed by spiraling growth (zone III) until the crystallization halted in cooler parts of the specimen. Zone II growth was imaged for several laser pulse energies with 20-ns electron pulses with 95 ns between frames. A thin liquid layer between the solid amorphous phase and the advancing crystallization front during zone II growth was imaged. The zone II growth rate for each experiment remained nearly constant although the crystallization front passes through a large temperature gradient. Measured growth rates ranged from 5.7 to 13.6 m/s, consistent with transient liquid layer mediated growth rather than solid-state growth. In contrast with a previous report, the growth rate did not increase systematically with laser energy or absorbed energy. The new results, together with previously reported data, suggest that both sets of experiments were conducted under conditions where the growth rate saturates near its maximum value. A phenomenological model based on the concept of upper and lower threshold temperatures for the zone II growth was fitted to the data from these experiments and previous MM-DTEM crystallization experiments.

36 MATERIALS SCIENCE↗

Ghost imaging second harmonic generation microscopy

Second harmonic generation (SHG) microscopy is useful for visualizing interfaces and sub-structures within a wide range of materials due to the propensity for SHG to occur in non-centrosymmetric environments. However, since SHG is a nonlinear process generally necessitating small focal sizes for higher peak powers, a raster scanning approach is usually needed to build an SHG image over a significant sample size. While raster scanning is effective, there is a cost in terms of the time needed to acquire the image and, also, some materials cannot withstand the higher optical intensities within the small focal volume. As such, we describe a SHG microscopy approach based on ghost imaging (GI), which enables imaging data to be collected in parallel rather than sequentially as in raster scanning techniques. We experimentally demonstrate the approach and combine GI-SHG with compressive sensing to make further substantial gains in reducing the amount of sampling required for image reconstruction. Furthermore, GI-SHG is shown to have significant advantages for imaging in highly scattering environments, partly because GI is a background-free approach requiring spatial correlations between photons that travel two paths, with one path entirely devoid of sample interaction. This basic property of GI means that only the photons that travel unimpeded through the sample preserve the spatial correlations needed to reconstruct the image, while more scattered photons do not contribute to the overall GI signal. Finally, we compare the image quality and sampling properties of three different reconstruction algorithms used for compressive sensing.

47 OTHER INSTRUMENTATION↗

Statistically elucidated responses from low-signal contrast mechanisms in ultrafast electron microscopy

The emergence of ultrafast electron microscopy (UEM) has enabled the discovery of strongly correlated dynamic mechanisms, including electron–phonon coupling, structural phase transitions, thermal transport, and electromagnetic deflection. Most UEM systems operate stroboscopically, meaning that the technique is susceptible to artifacts, mistakes, and misinterpretation of the data due to extensive experimental effort. In contrast to the ultrafast designation, data acquisition is extraordinarily slow because the electron beam has significantly reduced signal compared to traditional transmission electron microscopy due to pulsing the electron beam. Consequently, the sample may drift, tilt, or undergo irreversible structural changes that are independent of the time-resolved dynamics throughout the experimental time frame. Furthermore, these datasets require significant user interpretation that can be problematic when proper controls are not implemented thoroughly. Here, we demonstrate a new algorithm designed to separate ultrafast structural dynamics from long-term artifacts using a LiNbO 3 sample experiencing electrically driven surface acoustic wave propagation. Additionally, we provide examples of the impact of user bias when analyzing the data and provide a methodology, which enables the extraction of time-resolved responses when the image signal is extraordinarily low. Overall, the goal of this publication is to provide methods that validate the experimental results and reduce researcher biases during UEM data interpretation.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Deformation of Néel-type skyrmions revealed by Lorentz transmission electron microscopy

Néel-type magnetic skyrmions in multilayers are promising candidates for ultra-low power spintronic devices. To image the Néel-type skyrmions using Lorentz transmission electron microscopy (L-TEM), the samples must be tilted. Thus, the external magnetic field consists of both in-plane and out-of-plane components. To date, it is still not well known on the effect of the in-plane magnetic field on the L-TEM images, leading to ambiguities in retrieving the structure of Néel-type skyrmions. Here, Néel-type skyrmions in three [Pt/Co/Ta]$_{20}$ multilayer samples, with the easy magnetization axis being tuned from the out-of-plane to the in-plane direction by increasing the Co thickness from 1.8 to 2.2 nm, are imaged. When using a smaller defocus value (-2 mm) and a higher magnification (×9100) of L-TEM, a surprising dark-bright-dark-bright double contrasted pattern, instead of the previously reported dark-bright contrasted pattern, is observed. The additional dark-bright contrasted pattern becomes more evident for thicker Co layer samples in which the magnetization axis tilts more toward the in-plane direction. Further analysis, via a combination of magnetic force microscopy experiments, micromagnetic simulations, and micromagnetic analysis to Lorentz TEM simulation, shows that the additional dark-bright features originate from the deformation of the Néel-type skyrmions within an in-plane magnetic field.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Reconstruction of the interatomic forces from dynamic scanning transmission electron microscopy data

We explore the possibility for reconstruction of the generative physical models describing interactions between atomic units in solids from observational electron microscopy data. In this work, scanning transmission electron microscopy (STEM) is used to observe the dynamic motion of Si atoms at the edge of monolayer graphene under continuous electron beam illumination. The resulting time-lapsed STEM images represent the snapshots of observed chemical states of the system. We use two approaches: potential of mean force calculation using a radial distribution function and a direct fitting of the graphene–Si interatomic pairwise potentials with force matching, to reconstruct the force fields in the materials. These studies lay the foundation for quantitative analysis of materials energetics from STEM data through the sampling of the metastable states in the chemical space of the system.

42 ENGINEERING↗

Electronic structure of epitaxially grown and regrown GaN pn junctions characterized by scanning Kelvin probe and capacitance microscopy

Epitaxial regrowth of GaN pn junctions is a key technology for realization of a variety of high-performance GaN power electronic devices. However, the regrowth process can introduce impurities and defects that degrade a device’s performance. Here, we show that scanning Kelvin probe force microscopy and scanning capacitance microscopy can be used in a cross-sectional geometry to probe dopant distributions and an electronic structure in epitaxially grown GaN pn junctions. These measurements enable profiling of potential and dopant distributions across GaN pn junctions produced by uninterrupted epitaxial growth and by regrowth on an etched surface. Clear differences are observed in comparisons to the electronic structure of these two types of junctions that can be correlated with results of complementary characterization of dopant distributions reported for similarly grown structures. These measurements also suggest the presence of defects in etch-and-regrow pn junction structures that extend nearly 1 μm below the regrown interface.

Kim, Tae-Hyeon (ORCID:0000000341530617)↗

Resolving surface potential variation in Ge/MoS 2 heterostructures with Kelvin probe force microscopy

In this work, we employ an atomic force microscopy-based technique, Kelvin probe force microscopy, to analyze heterogeneities of four different 2D/3D Ge/MoS 2 heterostructures with Ge chemical vapor deposition (CVD) time. High-contrast spatially resolved contact potential difference (CPD) maps reveal the evolution of the samples by Ge deposition. The CPD map in an as-prepared sample does not display any heterogeneity, but CPD contrasts along the grain boundaries are obviously noticed as Ge is deposited on MoS 2 . With a sufficiently long Ge CVD deposition time, strong grain-to-grain CPD variations over the 2D/3D heterostructures are observed. The results show the variations of the work function from grain to grain that are attributed to the strain induced by the Ge island formation on the cracked MoS2 initiated by sulfur vacancies.

36 MATERIALS SCIENCE↗

Broadband coherent anti-Stokes Raman scattering (BCARS) microscopy for rapid, label-free biological imaging

Broadband coherent anti-Stokes Raman scattering (BCARS) microscopy is a label-free imaging approach that provides detailed chemical information at high spatial resolution in a sample through nonlinear, coherent excitation of molecular vibrations and detection of Raman spectra. While its utility for biological imaging has been demonstrated, many aspects of this technique must mature before it can be widely adopted. One of the areas of required improvement is imaging speed—most BCARS implementations involve sample rastering, which limits imaging speed. Beam scanning can provide faster BCARS imaging but presents some unique challenges. Here, we describe a beam-scanning BCARS microscopy system that improves spatial resolution twofold and imaging speed by fivefold over a previous beam-scanning implementation. These enhancements were enabled by an improvement in supercontinuum power and the use of a sCMOS camera for its high data transfer rate and low read noise. Implementation of the sCMOS camera required correction for the significant pixel-to-pixel background and photon response nonuniformity. Here, we report on the method that we implemented for calibrating and correcting the pixel-to-pixel differences in sCMOS camera noise.

Dixon, Jessica Z. [Georgia Institute of Technology↗

Automated scanning probe microscopy of combinatorial ferroelectric libraries: Gaussian-process-guided exploration and noise-aware experiment planning

Combinatorial materials libraries provide an efficient route for mapping composition–property relationships, but their broader impact depends on rapid, quantitative, and functionally relevant characterization. Scanning Probe Microscopy (SPM), including piezoresponse force microscopy (PFM), offers significant potential for quantitative, functionally relevant combi-library readouts. Here, we implement a fully automated SPM workflow for ferroelectric combinatorial libraries and benchmark Gaussian-process-based Bayesian optimization strategies for autonomous experiment planning. The workflow integrates automated probe motion, contact optimization, imaging, and dual amplitude resonance tracking-PFM spectroscopy, and uses scalarized spectroscopic observables to guide subsequent measurements. Stage motion, probe engagement, in-contact tuning, imaging, spectroscopy, and the choice of the next measurement location all proceed without human input. We demonstrate the approach on Sm-doped BiFeO 3 and Zn x Mg 1−x O libraries. By comparing vanilla Bayesian optimization with a measured-noise variant, we show that explicit treatment of local reproducibility can improve modeling of composition-dependent response when the measured variance is physically meaningful, but can also reduce robustness when variability is dominated by outliers or topographic artifacts. Furthermore, these results establish automated SPM as a bridge between combinatorial synthesis and quantitative functional characterization.

Liu, Yu [University of Tennessee, Knoxville, TN (U↗

Scanning photoelectron microscopy using a pointed capillary probe

The possibilities of a new type of scanning probe microscopy (SPM) for two different samples are experimentally demonstrated. The method is based on the use of a pointed capillary, which can simultaneously act as a ‘classical’ SPM probe and also as a controlled thin channel for transporting charged particles emitted by the surface to the detector. In the experiment, photoelectrons pass through a dielectric hollow cone probe with an aperture radius of 1 μm and detected by microchannel plates at different points of the investigated conducting surface irradiated by the second harmonic of a femtosecond Ti : sapphire laser. As a result, the sample’s surface profile is visualised with a subwavelength spatial resolution. This method makes it possible to control spatially localised beams of electrons, ions, neutral atoms (molecules) and soft X-ray radiation, as well as opens a possibility for research in the field of nanoscale photodesorption of molecular ions. (electron microscopy)

74 ATOMIC AND MOLECULAR PHYSICS↗