Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Measurement uncertainty”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 883 records · Page 49

Measurements of jet yield and acoplanarity using semi-inclusive $\gamma_{\text{dir}}$+jet and $\pi^{0}$+jet distributions in $p$+$p$ and central Au+Au collisions at $\sqrt{s_{NN}} = 200$ GeV by STAR

The STAR collaboration presents measurements of semi-inclusive distributions of charged jets recoiling from high transverse energy (E T ) direct photon and π 0 triggers in p+p and central Au+Au collisions at $\sqrt{s_{NN}} = 200$ GeV. Jets are reconstructed from charged particles using the anti-k T algorithm with jet resolution parameters R = 0.2 and 0.5. The large uncorrelated background in central Au+Au collisions is corrected using a mixed-event technique. This enables a jet measurement extending to low transverse momentum and large R with well-controlled systematic uncertainties. We present measurements of the jet R dependence of suppression, intra-jet broadening, and acoplanarity of π 0 +jet and γ dir +jet for trigger E T between 9–20 GeV.

Anderson, Derek↗

Measurement of Medium-induced Modification of Jet Yield and Acoplanarity Using Semi-inclusive \(\gamma _{\mathrm {dir}}+\)jet and \(\pi ^{0}+\)jet Distributions in \(p+p\) and Central Au\(+\)Au Collisions at \(\sqrt {s_{NN}} = 200\) GeV by STAR

The STAR Collaboration presents measurements of semi-inclusive distributions of charged jets recoiling from high transverse energy ($E_T$) direct photon and $π^0$ triggers in $p+p$ and central Au+Au collisions at $\sqrt{sNN}$=200 GeV. Jets are reconstructed from charged particles using the anti-$k_T$ algorithm with jet resolution parameters R=0.2 and 0.5. The large uncorrelated background in central Au+Au collisions is corrected using a mixed-event technique. This enables a jet measurement extending to low transverse momentum and large R with well-controlled systematic uncertainties. We present measurements of the jet R dependence of suppression, intra-jet broadening, and acoplanarity of $π^0$+jet and $γ_{dir}$+jet for trigger $E_T (E_{T}^{trig})$ between 9–20 GeV.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Credible Software and Simulation Uncertainty

The utility of software primarily depends on its reliability and performance; whereas, its significance depends solely on its credibility for intended use. The credibility of simulations confirms the credibility of software. The level of veracity and the level of validity of simulations determine the degree of credibility of simulations. The process of assessing this credibility in fields such as computational mechanics (CM) differs from that followed by the Defense Modeling and Simulation Office in operations research. Verification and validation (V&V) of CM simulations is not the same as V&V of CM software. Uncertainty is the measure of simulation credibility. Designers who use software are concerned with management of simulation uncertainty. Terminology and concepts are presented with a few examples from computational fluid dynamics.

Mehta, Unmeel B.↗

Measuring during a fault

Measuring instruments used in power systems will continue to report their results, even when there is a fault in the system. At such a time, the quality of the measurement is decreased, and the uncertainty of the value is increased. The uncertainty should be reported, but it rarely is. While power engineers have seemingly come to trust the results of such measurements without an uncertainty statement, in any case there is a fundamental problem with quantifying the uncertainty. The problem is not limited to power systems, though faults make it more evident. Uncertainty of the kind caused by a faulted power system can be considered definitional uncertainty, and that is normally evaluated statistically. It is not possible to perform statistics unless the measurement can be repeated at least a few times, and that is not an option outside the laboratory. This paper examines the matter from the viewpoint of measurement theory, and suggests a direction for some future work.

measurement, uncertainty, goodness of fit, degrees↗

A Tutorial on Bayesian analysis of linear shock compression data

Gas gun and other shock compression experiments often produce shock wave velocity measurements that are linearly associated with particle velocity. Traditionally, this empirical relationship is quantified with a single Hugoniot curve that is estimated using least squares regression. However, for downstream modeling and simulation tasks, it is often more useful to have multiple Hugoniot curves in the pressure–volume plane that are consistent with the data. We employ Bayesian uncertainty quantification methods as a framework for propagating measurement uncertainty through to model parameters and predictions. Specifically, this Tutorial shows how to sample multiple Hugoniot curves in the pressure–volume plane that are consistent with the shock wave-particle velocity measurements in a two-step Bayesian approach. First, we obtain an analytical expression for the posterior distribution of the linear model parameters using Bayesian linear regression. Second, we propagate samples from the posterior distribution through the Rankine–Hugoniot equations to yield Hugoniot curves in the pressure–volume plane. The procedure is demonstrated with publicly available data on argon, copper, and nickel, and compared against bootstrapping and linear regression. The Bayesian procedure is shown to be interpretable, computationally inexpensive, and less sensitive than an alternative bootstrapping approach to the removal of the point in the copper dataset that has the largest particle velocity. As a Tutorial on Bayesian methodology for the shock compression community, we provide several derivations and explanations that make this paper self-contained, and make all code and data available at github.com/llnl/BALSCD.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Temperature measurements in heavily-sooting ethylene/air flames using synchrotron x-ray fluorescence of krypton

High-fidelity temperature field measurements have been made for several heavily-sooting ethylene/air flames that have historically been challenging environments for conventional optical diagnostics. These challenges have largely been overcome here, in this study, by conducting x-ray fluorescence (XRF) measurements of a Kr fluorescent agent in the hard x-ray regime (15 keV). The current methodology presents a more economical diagnostic than a previously reported implementation of the Kr-XRF method, by limiting seeding of the expensive fluorescent agent to only the fuel stream flows. Detailed reacting flow simulations have been used to interpret experimental signals by tracking the mole fraction of the fluorescent agent in the flow field. Simulated Kr densities are in excellent agreement with measurements throughout the flow field. Temperature measurements of the flow field also agree well with simulations and recent literature studies. However, uncertainties in the measurements become increasingly large downstream of the burner surface as the krypton fraction drops due to mixing of the fuel and co-flow streams. Additionally, we demonstrate that soot particles in the heavily sooting flames studied do not impede the Kr-XRF measurements.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Critical Assessment of Electronic Structure Descriptors for Predicting Perovskite Catalytic Properties

The discovery and design of materials which can efficiently catalyze the oxygen reduction and evolution reactions at reduced temperatures is important for facilitating the widespread adoption of fuel cell and electrolyzer technologies. Numerous studies have produced correlations between catalytic properties, such as oxygen surface exchange or electrode area specific resistance (ASR), and properties of the catalyst material. However, correlations have historically been limited in scope (e.g., using only a few materials or at a single temperature) and it has been difficult to provide detailed assessments of their robustness. Here, in this study, we assess the ability of the O p-band center electronic structure descriptor, obtained from density functional theory (DFT) calculations, to correlate with oxygen surface exchange rates, diffusivities, and area specific resistances for a large database of perovskite oxide catalytic properties. By data mining the literature, we obtain 747 catalytic property value data points spanning 299 unique perovskite compositions from 313 studies. We assess linear correlations of each property with the O p-band center and find generally modest correlations that are qualitatively useful (prediction mean absolute errors of about 0.5 log units are typical), where the correlations are improved at higher temperatures (e.g., 800 °C vs. 500 °C) and significantly improve when considering fits to the subset of materials which have multiple independent measurements. These findings suggest that the spread of property data is significantly influenced by experimental uncertainty, and subsequent measurements of additional materials will likely improve the O p-band center correlations.

30 DIRECT ENERGY CONVERSION↗

Eclipse timings of the low-mass X-ray binary EXO 0748-676: Statistical arguments against orbital period changes

EXO 0748-676, an eclipsing low-mass X-ray binary, is one of only about four or five low-mass X-ray binaries for which orbital period evolution has been reported. We observed a single eclipse egress with ROSAT . The time of this egress is consistent with the apparent increase in P(sub orb) previously reported on the basis of EXOSAT and Ginga observations. Standard analysis, in which O-C (observed minus calculated) timing residuals are examined for deviations from a constant period, implicitly assume that the only uncertainty in each residual is measurement error and that these errors are independent. We argue that the variable eclipse durations and profiles observed in EXO 0748-676 imply that there is an additional source of uncertainty in timing measurements, that this uncertainty is intrinsic to the binary system, and that it is correlated from observation to observation with a variance which increases as a function of the number of binary cycles between observations. This intrinsic variability gives rise to spurious trends in O-C residuals which are misinterpreted as changes in the orbital period. We describe several statistics tests which can be used to test for the presence of intrinsic variability. We apply those statistical tests which are suitable to the EXO 0748-676 observations. The apparent changes in the orbital period of EXO 0748-676 can be completely accounted for by intrinsic variability with an rms variability of approximately 0.35 s per orbital cycle. The variability appears to be correlated from cycle-to-cycle on timescales of less than 1 yr. We suggest that the intrinsic variability is related to slow changes in either the source's X-ray luminosity or the structure of the companion star's atmosphere. We note that several other X-ray binaries and cataclysmic variables have previously reported orbital period changes which may also be due to intrinsic variability rather than orbital period evolution.

Hertz, Paul↗

The completed SDSS-IV extended Baryon Oscillation Spectroscopic Survey: cosmological implications from multitracer BAO analysis with galaxies and voids

We construct cosmic void catalogues with the dive void finder upon SDSS BOSS DR12 and eBOSS DR16 galaxy samples with BAO reconstruction, and perform a joint BAO analysis using different types of galaxies and the corresponding voids. The BAO peak is evident for the galaxy–galaxy, galaxy–void, and void–void correlation functions of all data sets, including the ones cross-correlating LRG and ELG samples. Two multitracer BAO fitting schemes are tested, one combining the galaxy and void correlation functions with a weight applied to voids, and the other using a single BAO dilation parameter for all clustering measurements. Both methods produce consistent results with mock catalogues, and on average ~10 per cent improvements of the BAO statistical uncertainties are observed for all samples, compared to the results from galaxies alone. By combining the clustering of galaxies and voids, the uncertainties of BAO measurements from the SDSS data are reduced by 5–15 per cent, yielding 0.9 per cent, 0.8 per cent, 1.1 per cent, 2.3 per cent, and 2.9 per cent constraints on the distance $D_{_{\rm V}}(z)$, at effective redshifts 0.38, 0.51, 0.70, 0.77, and 0.85, respectively. When combined with BAO measurements from SDSS MGS, QSO, and Lyα samples, as well as the BBN results, we obtain $H_0 = 67.58 \pm 0.91\, {\rm km}\, {\rm s}^{-1}\, {\rm Mpc}^{-1}$, Ω m = 0.290 ± 0.015, and $\Omega _\Lambda h^2 = 0.3241 \pm 0.0079$ in the flat-ΛCDM framework, where the 1σ uncertainties are around 6 per cent, 6 per cent, and 17 per cent smaller respectively, compared to constraints from the corresponding anisotropic BAO measurements without voids and LRG–ELG cross-correlations.

79 ASTRONOMY AND ASTROPHYSICS↗

Electron and photon reconstruction and identification with the CMS experiment at the CERN LHC

The performance is presented of the reconstruction and identification algorithms for electrons and photons with the CMS experiment at the LHC. The reported results are based on proton-proton collision data collected at a center-of-mass energy of 13 TeV and recorded in 2016–2018, corresponding to an integrated luminosity of 136 fb^-1. Results obtained from lead-lead collision data collected at √(sNN)=5.02 TeV are also presented. Innovative techniques are used to reconstruct the electron and photon signals in the detector and to optimize the energy resolution. Events with electrons and photons in the final state are used to measure the energy resolution and energy scale uncertainty in the recorded events. The measured energy resolution for electrons produced in Z boson decays in proton-proton collision data ranges from 2 to 5%, depending on electron pseudorapidity and energy loss through bremsstrahlung in the detector material. The energy scale in the same range of energies is measured with an uncertainty smaller than 0.1 (0.3)% in the barrel (endcap) region in proton-proton collisions and better than 1 (3)% in the barrel (endcap) region in heavy ion collisions. The timing resolution for electrons from Z boson decays with the full 2016–2018 proton-proton collision data set is measured to be 200 ps.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Specification of EBR-II Contact Profilometry Data

All contact profilometry data stored in FIPD was originally measured using the HFEF vertical contact profilometer, which was an electronic gauge to measure the diameter profile of an element or capsule continuously over the region of interest. The element could be rotated as it passed through the probes if the wire wrap was not to be removed and the element could be returned to reactor for further irradiation. If the wire wrap was removed, the element could be drawn vertically through the probes, rotated, and the process repeated. In this way any cladding ovality could be observed. Figure 1 shows the setup used to measure the fuel pin diameter profile. The ambient temperature during the measurement was ~21-23 ºC. The cladding temperature during the measurement is considered to be similar to the ambient temperature by assuming the fuel decay heat did not impact the cladding temperature. Two documents contain most of the important details about contact profilometry measurements. The first one is the operational manual of the contact profilometer (title: Element contact profilometer operation and maintenance, HFEF/N OMM 4326, DOC. NO. W0202-0007-SA-01). This manual provides: (1) description of the contact profilometer including the functions of each component (support stage, sensing head, control system, and calibration standards, etc.); (2) step-by-step guidance on calibrations, operations, and measurements; and (3) maintenance procedures and other details of the contact profilometer. The second document is a publicly accessible report entitled “A Fuel-element Profilometer for the HFEF.” This report describes the development of the contact profilometer, including the design requirements, features, and details of each component, as well as the acceptance tests for the built system. This document is important because it reports the uncertainties of the measurements with detailed deduction procedures. The reported uncertainties should apply to all hard-copy contact profilometry data in FIPD. Some key information about contact profilometry measurements was extracted from these two documents. Combining the information with other sources, a specification for interpretating the contact profilometry data in FIPD was established.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Runaway electron plateau current profile reconstruction from synchrotron imaging and Ar-II line polarization angle measurements in DIII-D

Abstract Current profile reconstructions are obtained for high current ( I p ≃ 550 kA) post-disruption runaway electron (RE) plateau plasmas in DIII-D. Two novel methods of measuring the RE current profile in high-current RE plateaus are introduced and compared: localization of the q = 2 rational surface using visible synchrotron emission (SE) imaging and the measurement of the polarization angle of line-integrated Ar-II line emission. The two methods are found to be consistent with each other within the data uncertainties. Different simulations of the RE current profile are compared with the measurements: the toroidal fluid RE model is found to best fit the data, within the measurement uncertainties. In addition to introducing two novel methods to measure the RE current profile and validating present simulation capabilities, this work demonstrates that instabilities can grow at q = 2 and q = 1 surfaces without necessarily causing a RE final loss instability. Numerical simulations are also presented to elucidate the role of these instabilities on synchrotron emission.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Probable LAGEOS contributions to a worldwide geodynamics control network

The paper describes simulations performed on the contributions which LAGEOS laser ranging data can make to the establishment of a worldwide geodynamics control network. A distribution of 10 fixed ranging stations was assumed for most of the calculations, and a single 7-day arc was used, measurements assumed to be made every 10 minutes in order to avoid artificial reductions in the uncertainties due to oversampling. Computer simulations were carried out in which the coordinates of the stations and improvements in the gravity field coefficients were solved for simultaneously. It is suggested that good accuracy for station coordinates can be expected, even with the present gravity field model uncertainties, if sufficient measurement accuracy is achieved at a reasonable distribution of stations. Further, it is found that even 2-cm range measurement errors would be likely to be the main source of station coordinate errors in retrospective analyses of LAGEOS ranging results five or six years from now.

Bender, P. L.↗

Discovery of a Doppler-limited CO line in the upper mesosphere of Venus - A new dynamical probe

The presence of CO in the upper atmosphere of Venus is a consequence of the photochemistry of CO2, the dominant atmospheric constituent. In December 1989 the J = 1-2 transition of CO was observed at 230 GHz. In addition to the broad absorption line first reported by Kakar et al. (1976), a narrow absorption feature at the center of the line due to upper mesospheric CO, where the temperature profile starts to exhibit diurnal variation with altitude. The narrow feature is approximately 600 kHz wide and is predominantly Doppler-broadened. The Doppler core provides a new means of measuring wind velocities at these altitudes in the atmosphere of Venus. Detection of small Doppler shifts in the line core can in principle be used to measure winds with an accuracy of 10 m/s. Results are presently limited by the 17 kHz uncertainty in the measured rest frequency, corresponding to a systematic error in wind velocity up to 22 m/s, and the absence of laboratory measurements of the pressure shift in CO by CO2.

Buhl, David↗

Mass Spectrometric Measurement of Martian Krypton and Xenon Isotopic Abundance

The Viking gas chromatograph mass spectrometer experiment provided significant data on the atmospheric composition at the surface of Mars, including measurements of several isotope ratios. However, the limited dynamic range of this mass spectrometer resulted in marginal measurements for the important Kr and Xe isotopic abundance. The Xe-129 to Xe-132 ratio was measured with an uncertainty of 70%, but none of the other isotope ratios for these species were obtained. Accurate measurement of the Xe and Kr isotopic abundance in this atmosphere provides an important data point in testing theories of planetary formation and atmospheric evolution. The measurement is also essential for a stringent test for the Martian origin of the SNC meteorites, since the Kr and Xe fractionation pattern seen in gas trapped in glassy nodules of an SNC (EETA 79001) is unlike any other known solar system resevoir. Current flight mass spectrometer designs combined with the new technology of a high-performance vacuum pumping system show promise for a substantial increase in gas throughput and the dynamic range required to accurately measure these trace species. Various aspects of this new technology are discussed.

Mahaffy, P.↗

Spectralon BRDF and DHR Measurements in Support of Satellite Instruments Operating Through Shortwave Infrared

Satellite instruments operating in the reflective solar wavelength region require accurate and precise determination of the Bidirectional Reflectance Distribution Functions (BRDFs) of the laboratory and flight diffusers used in their pre-flight and on-orbit calibrations. This paper advances that initial work and presents a comparison of spectral Bidirectional Reflectance Distribution Function (BRDF) and Directional Hemispherical Reflectance (DHR) of Spectralon*, a common material for laboratory and onorbit flight diffusers. A new measurement setup for BRDF measurements from 900 nm to 2500 nm located at NASA Goddard Space Flight Center (GSFC) is described. The GSFC setup employs an extended indium gallium arsenide detector, bandpass filters, and a supercontinuum light source. Comparisons of the GSFC BRDF measurements in the ShortWave InfraRed (SWIR) with those made by the NIST Spectral Trifunction Automated Reference Reflectometer (STARR) are presented. The Spectralon sample used in this study was 2 inch diameter, 99% white pressed and sintered Polytetrafluoroethylene (PTFE) target. The NASA/NIST BRDF comparison measurements were made at an incident angle of 0 deg and viewing angle of 45 deg. Additional BRDF data not compared to NIST were measured at additional incident and viewing angle geometries and are not presented here The total combined uncertainty for the measurement of BRDF in the SWIR range made by the GSFC scatterometer is less than 1% (k=1). This study is in support of the calibration of the Joint Polar Satellite System (JPSS) Radiation Budget Instrument (RBI) and Visible Infrared Imaging Radiometer Suite (VIIRS) of and other current and future NASA remote sensing missions operating across the reflected solar wavelength region.

Georgiev, Georgi T.↗

Surface erythemal UV irradiance in the continental United States derived from ground-based and OMI observations: quality assessment, trend analysis and sampling issues

Surface full-sky erythemal dose rate (EDR) from the Ozone Monitoring Instrument (OMI) at both satellite overpass time and local noon time is evaluated against ground measurements at 31 sites from the US Department of Agriculture's (USDA) UV-B Monitoring and Research Program (UVMRP) over the period of 2005–2017. We find that both OMI overpass and solar noon time EDR are highly correlated with the measured counterparts (with a linear correlation coefficient of 0.90 and 0.88, respectively). Although the comparison statistics are improved with a longer time window (0.5–1.0 h) for pairing surface and OMI measurements, both OMI overpass and local noon time EDRs have 7 % overestimation that is larger than 6 % uncertainty in the ground measurements and show different levels of dependence on solar zenith angle (SZA) and to lesser extent on cloud optical depth. The ratio of EDR between local noon and OMI overpass time is often (95 % in frequency) larger than 1 with a mean of 1.18 in the OMI product; in contrast, the same ratio from surface observation is normally distributed with 22 % of the times less than 1 and a mean of 1.38. This contrast in part reflects the deficiency in the OMI surface UV algorithm that assumes constant atmospheric conditions between overpass and noon time. The probability density functions (PDFs) for both OMI and ground measurements of noontime EDR are in statistically significant agreement, showing dual peaks at ∼20 and ∼200 mW/sq. m, respectively; the latter is lower than 220 mW/ sq. m, the value at which the PDF of daily EDR from ground measurements peaks, and this difference indicates that the largest EDR value for a given day may not often occur at local noon. Lastly, statistically significant positive trends of EDR are found in the northeastern US in OMI data, but opposite trends are found within ground-based data (regardless of sampling for either noontime or daily averages). While positive trends are consistently found between OMI and surface data for EDR over the southern Great Plains (Texas and Oklahoma), their values are within the uncertainty of ground measurements. Overall, no scientifically sound trends can be found among OMI data for aerosol total and absorbing optical depth, cloud optical depth and total ozone to explain coherently the surface UV trends revealed either by OMI or ground-based estimates; these data also cannot reconcile trend differences between the two estimates (of EDR from OMI and surface observations). Future geostationary satellites with better spatiotemporal resolution data should help overcome spatiotemporal sampling issues inherent in OMI data products and therefore improve the estimates of surface UV flux and EDR from space.

Ozone Monitoring Instrument (OMI)↗

SeaWiFS Postlaunch Technical Report Series: The SeaWiFS Solar Radiation-Based Calibration and the Transfer-to-Orbit Experiment - Volume 5

The solar radiation-based calibration (SRBC) of the Sea-viewing Wide Field-of-view Sensor (SeaWiFS) was performed on 1 November 1993. Measurements were made outdoors in the courtyard of the instrument manufacturer. SeaWiFS viewed the solar irradiance reflected from the sensor's diffuser in the same manner as viewed on orbit. The calibration included measurements using a solar radiometer designed to determine the transmittances of principal atmospheric constituents. The primary uncertainties in the outdoor measurements are the transmission of the atmosphere and the reflectance of the diffuser. Their combined uncertainty is about 5 or 6%. The SRBC also requires knowledge of the extraterrestrial solar spectrum. Four solar models are used. When averaged over the responses of the SeaWiFS bands, the irradiance models agree at the 3.6% level, with the greatest difference for SeaWiFS band 8. The calibration coefficients from the SRBC are lower than those from the laboratory calibration of the instrument in 1997. For a representative solar model, the ratios of the SRBC coefficients to laboratory values average 0.962 with a standard deviation of 0.012. The greatest relative difference is 0.946 for band 8. These values are within the estimated uncertainties of the calibration measurements. For the transfer-to-orbit experiment, the measurements in the manufacturer's courtyard are used to predict the digital counts from the instrument on its first day on orbit (August 1, 1997). This experiment requires an estimate of the relative change in the diffuser response for the period between the launch of the instrument and its first solar measurements on orbit (September 9, 1997). In relative terms, the counts from the instrument on its first day on orbit averaged 1.3% higher than predicted, with a standard deviation of 1.2% and a greatest difference of 2.4% or band 7. The estimated uncertainty for the transfer-to-orbit experiment is about 3 or 4%.

Hooker, Stanford B.↗