Thermodynamic Modeling and Optimization of the Copper Flash Converting Process Using the Equilibrium Constant Method
Based on the principle of multiphase equilibrium, a mathematical model of the copper flash converting process was established by the equilibrium constant method, and a computational system was developed with the use of MetCal software platform. The mathematical model was validated by comparing simulated outputs, industrial data, and published data. To obtain high-quality blister copper, a low copper content in slag, and increased impurity removal rate, the model was then applied to investigate the effects of the operational parameters [oxygen/feed ratio (R{sub OF}), flux rate (R{sub F}), and converting temperature (T)] on the product weights, compositions, and the distribution behaviors of impurity elements. The optimized results showed that R{sub OF}, R{sub F}, and T should be controlled at approximately 156 Nm{sup 3}/t, within 3.0 pct, and at approximately 1523 K (1250 °C), respectively.