Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MAGNETIC INSTRUMENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 883 records · Page 49

Improvement on the Magnetic Shielding for the XRISM/Resolve Adiabatic Demagnetization Refrigerator

We report modeling, fabrication, cryogenic tensile testing, and magnetic field measurements of a shield around an adiabatic demagnetization stage (ADR) built for the XRISM/Resolve instrument. During testing of a near-identical stage built for Astro-H, a previous spaceflight mission, it was determined that the magnet at full current generated a field external to the shield that violated the maximum dipole-moment requirement of the spacecraft. In addition, there was an interference with the detector assembly nearby when the magnet was greater than 85% of it's typical maximum current. Starting with the Astro-H shield design, we performed a parametric study that increased the thickness of the shield in critical regions. This calculation proceeded until the magnetic field satisfied the estimated maximum field allowed at the detector array based upon the Astro-H measurements. We also performed a detailed measurement of the field generated by the ADR stage at full current as a function of relative angle between the magnet axis and a series of flux-gate magnetometers. Details and results from the calculation and subsequent measurement will be presented.

ADR↗

Hydraulic concentration of magnetic fields in the solar photosphere. II - Bernoulli effect

The magnetic filaments in the solar photosphere are subject to vigorous kneading and massaging by the convective turbulence at, and beneath, the visible surface. It is shown that the Bernoulli effect of the consequent surging of fluid up and down along the filaments is a major factor in concentrating the magnetic pressure of the filament (the mean square field). The mean field is also increased if the phase velocity of the external massaging exceeds the Alfven speed within the filament. The net observational magnetic result of the surging, then, depends upon the response of the observing instrument, and whether it essentially observes the mean field, the rms field, or whether there are saturation effects. It is suggested that the chromospheric mottles (spicules) seen in H alpha are in fact the intense magnetic filaments that carry most of the magnetic flux across the photospheric boundary of the sun.

Parker, E. N.↗

A DEDICATED CHANDRA ACIS OBSERVATION OF THE CENTRAL COMPACT OBJECT IN THE CASSIOPEIA A SUPERNOVA REMNANT

We present results of a recent Chandra X-ray Observatory observation of the central compact object (CCO) in the supernova remnant (SNR) Cassiopeia A. This observation was carried out in an instrumental configuration that combines a high spatial resolution with a minimum spectral distortion, and it allowed us to search for pulsations with periods longer than {approx}0.68 s. We found no evidence of extended emission associated with the CCO, nor statistically significant pulsations (the 3{sigma} upper limit on pulsed fraction is about 16%). The fits of the CCO spectrum with the power-law model yield a large photon index, {Gamma} {approx} 5, and a hydrogen column density larger than that obtained from the SNR spectra. The fits with the blackbody model are statistically unacceptable. Better fits are provided by hydrogen neutron star atmosphere models, with the best-fit effective temperature kT{sup {infinity}}{sub eff} {approx} 0.2 keV, but they require a small star's radius, R = 4-5.5 km, and a low mass, M {approx}< 0.8 M{sub sun}. A neutron star cannot have so small radius and mass, but the observed emission might emerge from an atmosphere of a strange quark star. More likely, the CCO could be a neutron star with a nonuniform surface temperature and a low surface magnetic field (the so-called anti-magnetar), similar to three other CCOs for which upper limits on period derivative have been established. The bolometric luminosity, L{sup {infinity}}{sub bol} {approx} 6 x 10{sup 33} erg s{sup -1}, estimated from the fits with the hydrogen atmosphere models is consistent with the standard neutron star cooling for the CCO age of 330 yr. The origin of the surface temperature's nonuniformity remains to be understood; it might be caused by anisotropic heat conduction in the neutron star crust with very strong toroidal magnetic fields.

79 ASTRONOMY AND ASTROPHYSICS↗

Imaging electron motion in graphene

A cooled scanning probe microscope (SPM) is an ideal tool to image electronic motion in graphene: the SPM tip acts as a scanning gate, which interacts with the electron gas below. We introduce the technique using our group's previous work on imaging electron flow from a quantum point contact in a GaAs 2DEG and tuning an InAs quantum dot in an InAs/InP nanowire. Carriers in graphene have very different characteristics: electrons and holes travel at a constant speed with no bandgap, and they pass through potential barriers via Klein tunneling. In this paper, we review the extension of SPM imaging techniques to graphene. We image the cyclotron orbits passing between two narrow contacts in a single-atomic-layer graphene device in a perpendicular magnetic field. Magnetic focusing produces a peak in transmission between the contacts when the cyclotron diameter is equal to the contact spacing. The charged SPM tip deflects electrons passing from one contact to the other, changing the transmission when it interrupts the flow. By displaying the change in transmission as the tip is raster scanned above the sample, an image of flow is obtained. In addition, we have developed a complementary technique to image electronic charge using a cooled scanning capacitance microscope (SCM) that uses a sensitive charge preamplifier near the SPM tip to achieve a charge noise level 0.13 e Hz -1/2 with high spatial resolution 100 nm. The cooled SPM and SCM can be used to probe the motion of electrons on the nanoscale in graphene devices.

36 MATERIALS SCIENCE↗

A visualization instrument to investigate the mechanical-electro properties of high temperature superconducting tapes under multi-fields

We construct a visible instrument to study the mechanical-electro behaviors of high temperature superconducting tape as a function of magnetic field, strain, and temperature. This apparatus is directly cooled by a commercial Gifford-McMahon cryocooler. The minimum temperature of sample can be 8.75 K. A proportion integration differentiation temperature control is used, which is capable of producing continuous variation of specimen temperature from 8.75 K to 300 K with an optional temperature sweep rate. We use an external loading device to stretch the superconducting tape quasi-statically with the maximum tension strain of 20%. A superconducting magnet manufactured by the NbTi strand is applied to provide magnetic field up to 5 T with a homogeneous range of 110 mm. The maximum fluctuation of the magnetic field is less than 1%. We design a kind of superconducting lead composed of YBa2Cu3O7-x coated conductor and beryllium copper alloy (BeCu) to transfer DC to the superconducting sample with the maximum value of 600 A. Most notably, this apparatus allows in situ observation of the electromagnetic property of superconducting tape using the classical magnetic-optical imaging.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

TRW plasma wave experiment for the IMP-H mission

The IMP-H plasma wave experiment is designed to extend knowledge of wave-particle interactions in the disturbed cislunar region, the distant geomagnetic tail, the upstream solar wind, and the flanks of the magnetosheath-shock interface. It is expected to identify plasma instabilities, study particle acceleration and heating at collisionless shocks and other discontinuities, analyze turbulent conductivity and field line merging, and provide new information on dissipation processes for suprathermal particles. Instrumentation for the plasma wave experiment is designed to measure local electric and magnetic field oscillations over the frequency range 10 Hz to 100 kHz. A 24 inch electric dipole, a 7 inch diameter air core search coil, and the associated preamplifiers are mounted on a spacecraft counterweight boom. The frequency range of 10 Hz to 100 kHz for both E and B is processed using an eight-channel spectrum analyzer located in the instrument main-body package (a standard IMP trapezoidal module, 3 inches high). Electric fields as small as 10-100 microvolts/meter and magnetic signals as small as 1-3 milligamma will be detected.

Virobik, P. F.↗

TESTING OF NB{sub 3}SN QUADRUPOLE COILS USING MAGNETIC MIRROR STRUCTURE

This paper describes the design and parameters of a quadrupole mirror structure for testing the mechanical, thermal and quench performance of single shell-type superconducting quadrupole coils at field, current and force levels similar to that of real magnet. The concept was experimentally verified by testing two quadrupole coils, previously used in quadrupole models, in the developed mirror structure in the temperature range from 4.5 to 1.9 K. The coils were instrumented with voltage taps, heaters, and strain gauges to monitor their mechanical and thermal properties and quench performance. A new quadrupole coil made of improved Nb{sub 3}Sn RRP-108/127 strand and cable insulation based on E-glass tape was also tested using this structure. The fabrication and test results of the quadrupole mirror models are reported and discussed.

36 MATERIALS SCIENCE↗

Enabling resonant ultrasound spectroscopy in high magnetic fields

Resonant ultrasound spectroscopy (RUS) is a powerful method to determine elastic constants with high accuracy and precision from a single measurement of the mechanical resonances of a sample. Conventionally, the quantitative extraction of elastic moduli with RUS assumes free boundary conditions which can often lead to the adoption of unstable sample positioning between ultrasonic transducers that is incompatible with extreme environments like high magnetic fields. We show that, under specific conditions, introducing a small amount of adhesive between a RUS sample and ultrasonic transducers introduces a perturbation to the free resonance condition which can be accounted for by a simple model. This means elastic constants can be determined to within the uncertainty of conventional RUS, but with significant improvements including sample stability and control of sample orientation. We demonstrate the efficacy of this approach with measurements on a range of materials including room temperature measurements on polycrystalline metals, temperature-dependent measurements of the structural phase transition in strontium titanate single crystals, and magnetic field-dependent measurements of magnetic phase transitions in gadolinium polycrystals up to 14 T.

47 OTHER INSTRUMENTATION↗

The Magnetospheric Multiscale Constellation

The Magnetospheric Multiscale (MMS) mission is the fourth mission of the Solar Terrestrial Probe (STP) program of the National Aeronautics and Space Administration (NASA). The MMS mission was launched on March 12, 2015. The MMS mission consists of four identically instrumented spin-stabilized observatories which are flown in formation to perform the first definitive study of magnetic reconnection in space. The MMS mission was presented with numerous technical challenges, including the simultaneous construction and launch of four identical large spacecraft with 100 instruments total, stringent electromagnetic cleanliness requirements, closed-loop precision maneuvering and pointing of spinning flexible spacecraft, on-board GPS based orbit determination far above the GPS constellation, and a flight dynamics design that enables formation flying with separation distances as small as 10 km. This paper describes the overall mission design and presents an overview of the design, testing, and early on-orbit operation of the spacecraft systems and instrument suite.

Space mission design↗

Markov properties of the magnetic field in the quiet solar photosphere

The observed magnetic field on the solar surface is characterized by a very complex spatial and temporal behavior. Although feature-tracking algorithms have allowed us to deepen our understanding of this behavior, subjectivity plays an important role in the identification and tracking of such features. In this paper, we study the temporal stochasticity of the magnetic field on the solar surface without relying on either the concept of magnetic feature or on the subjective assumptions about their identification and interaction. The analysis is applied to observations of the magnetic field of the quiet solar photosphere carried out with the Imaging Magnetograph eXperiment (IMaX) instrument on board the stratospheric balloon, Sunrise. We show that the joint probability distribution functions of the longitudinal (B{sub ∥}) and transverse (B{sub ⊥}) components of the magnetic field, as well as of the magnetic pressure (B{sup 2}=B{sub ⊥}{sup 2}+B{sub ∥}{sup 2}), verify the necessary and sufficient condition for the Markov chains. Therefore, we establish that the magnetic field as seen by IMaX with a resolution of 0.″15–0.″18 and 33 s cadence, which can be considered as a memoryless temporal fluctuating quantity.

79 ASTRONOMY AND ASTROPHYSICS↗

Geodetic Investigations of the Mission Concept MAGIC to Reveal Callisto’s Internal Structure

Geodetic and geophysical investigations of the Galilean moon Callisto address fundamental questions regarding the formation and evolution of the Jovian system. Callisto's evolution and internal structure appear to significantly differ from the other Jovian satellites. Similarly-sized Ganymede is a highly evolved ice-rock moon with a differentiated interior, intrinsic magnetic field, and abundant surface evidence of internal activity. In contrast, Callisto's surface is ancient, and Galileo spacecraft data suggest its interior is only incompletely differentiated, despite the presumed presence of a sub-surface ocean. These properties make Callisto uniquely able to constrain the timing and nature of the Jovian system formation. The Magnetics, Altimetry, Gravity, and Imaging of Callisto (MAGIC) mission concept is conceived to fully characterize the properties of this enigmatic moon from its deep interior to the icy shell. Three main instruments are included as a scientific payload. Highly accurate measurements of Callisto's topography, magnetic field, and morphology are obtained by the onboard laser altimeter, magnetometer, and camera, respectively. The telecommunication system supports an additional gravity and radio science investigation. Long- and short-wavelength gravity anomalies afford powerful constraints on internal differentiation and the properties of the hydrosphere (water and ice). Comprehensive numerical simulations and covariance analyses of MAGIC mission scenarios presented in this paper show that the gravitational degree-2 normalized coefficients and the pole obliquity enable the determination of the moment of inertia with an accuracy better than 0.015%. The combination of gravity and altimetry measurements acquired by MAGIC are essential to the characterization of Callisto's interior if – as is likely – the degree-2 gravity includes non-hydrostatic terms. MAGIC's radio science data yield the estimation of Callisto's gravity field with spatial resolutions of <100 km. The combination of gravitational and deformation tides that are retrieved by the radio science and altimetry investigations, respectively, leads to the recovery of the rigid ice shell thickness to within ∼3 km. Together these datasets would resolve ambiguities inherent in Galileo flyby data, revealing Callisto's interior structure as well as the existence and properties of its postulated internal ocean.

Antonio Genova↗

LabVIEW-based control software for para-hydrogen induced polarization instrumentation

The elucidation of cell metabolic mechanisms is the modern underpinning of the diagnosis, treatment, and in some cases the prevention of disease. Para-Hydrogen induced polarization (PHIP) enhances magnetic resonance imaging (MRI) signals over 10 000 fold, allowing for the MRI of cell metabolic mechanisms. This signal enhancement is the result of hyperpolarizing endogenous substances used as contrast agents during imaging. PHIP instrumentation hyperpolarizes Carbon-13 ({sup 13}C) based substances using a process requiring control of a number of factors: chemical reaction timing, gas flow, monitoring of a static magnetic field (B{sub o}), radio frequency (RF) irradiation timing, reaction temperature, and gas pressures. Current PHIP instruments manually control the hyperpolarization process resulting in the lack of the precise control of factors listed above, resulting in non-reproducible results. We discuss the design and implementation of a LabVIEW based computer program that automatically and precisely controls the delivery and manipulation of gases and samples, monitoring gas pressures, environmental temperature, and RF sample irradiation. We show that the automated control over the hyperpolarization process results in the hyperpolarization of hydroxyethylpropionate. The implementation of this software provides the fast prototyping of PHIP instrumentation for the evaluation of a myriad of {sup 13}C based endogenous contrast agents used in molecular imaging.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Atomic scale electron vortices for nanoresearch

Electron vortex beams were only recently discovered and their potential as a probe for magnetism in materials was shown. Here we demonstrate a method to produce electron vortex beams with a diameter of less than 1.2 Angst . This unique way to prepare free electrons to a state resembling atomic orbitals is fascinating from a fundamental physics point of view and opens the road for magnetic mapping with atomic resolution in an electron microscope.

36 MATERIALS SCIENCE↗

Energetic ion observations in the magnetic cloud of 14-15 January 1988 and their implications for the magnetic field topology

On 14-15 January 1988, a magnetic cloud with a local field topology consistent with an east-west aligned cylindrical flux-rope and which formed the driver of an interplanetary shock passed the earth. Using 0.5-4 MeV/n ion data from the instrument on IMP 8, the paper addresses the question of whether or not magnetic field lines within the magnetic cloud were connected to the sun. An impulsive solar particle event was detected inside the magnetic cloud strongly suggesting that the field lines were rooted at the sun.

Richardson, I. G.↗

HOMOLOGOUS HELICAL JETS: OBSERVATIONS BY IRIS, SDO, AND HINODE AND MAGNETIC MODELING WITH DATA-DRIVEN SIMULATIONS

We report on observations of recurrent jets by instruments on board the Interface Region Imaging Spectrograph, Solar Dynamics Observatory (SDO), and Hinode spacecraft. Over a 4 hr period on 2013 July 21, recurrent coronal jets were observed to emanate from NOAA Active Region 11793. Far-ultraviolet spectra probing plasma at transition region temperatures show evidence of oppositely directed flows with components reaching Doppler velocities of ±100 km s{sup −1}. Raster Doppler maps using a Si iv transition region line show all four jets to have helical motion of the same sense. Simultaneous observations of the region by SDO and Hinode show that the jets emanate from a source region comprising a pore embedded in the interior of a supergranule. The parasitic pore has opposite polarity flux compared to the surrounding network field. This leads to a spine-fan magnetic topology in the coronal field that is amenable to jet formation. Time-dependent data-driven simulations are used to investigate the underlying drivers for the jets. These numerical experiments show that the emergence of current-carrying magnetic field in the vicinity of the pore supplies the magnetic twist needed for recurrent helical jet formation.

79 ASTRONOMY AND ASTROPHYSICS↗

On ultrafast x-ray scattering methods for magnetism

With the introduction of x-ray free electron laser sources around the world, new scientific approaches for visualizing matter at fundamental length and time-scales have become possible. As it relates to magnetism and ‘magnetic-type’ systems, advanced methods are being developed for studying ultrafast magnetic responses on the time-scales at which they occur. We describe three capabilities which have the potential to seed new directions in this area and present original results from each: pump-probe x-ray scattering with low energy excitation, x-ray photon fluctuation spectroscopy, and ultrafast diffuse x-ray scattering. By combining these experimental techniques with advanced modeling together with machine learning, we describe how the combination of these domains allows for a new understanding in the field of magnetism. Finally, we give an outlook for future areas of investigation and the newly developed instruments which will take us there.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗