Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “LCLS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 883 records · Page 49

Thermometric- and Acoustic-Based Beam Power Monitor for Ultra-Bright X-Rays

A design for an average beam power monitor for ultra-bright X-ray sources is proposed that makes simultaneous use of calorimetry and radiation acoustics. Radiation incident on a solid target will induce heating and ultrasonic vibrations, both of which may be measured to give a fairly precise value of the beam power. The monitor is intended for measuring ultra-bright Free-Electron Laser (FEL) X-ray beams, for which traditional monitoring technologies such as photo-diodes or scintillators are unsuitable. The monitor consists of a Boron Carbide (B{sub 4}C) target designed to absorb most of the incident beam's energy. Resistance temperature detectors (RTD) and piezoelectric actuators are mounted on the outward faces of the target to measure the temperature changes and ultrasonic vibrations induced by the incident beam. The design was tested using an optical pulsed beam (780 nm, 120 and 360 Hz) from a Ti:sapphire oscillator at several energies between 0.8 and 2.6 mJ. The RTDs measured an increase in temperature of about 10 K over a period of several minutes. The piezoelectric sensors recorded ringing acoustic oscillations at 580 {+-} 40 kHz. Most importantly, the amplitude of the acoustic signals was observed to scale linearly with beam power up to 2 mJ of pulse energy. Above this pulse energy, the vibrational signals became nonlinear. Several causes for this nonlinearity are discussed, including amplifier saturation and piezoelectric saturation. Despite this nonlinearity, these measurements demonstrate the feasibility of such a beam power measurement device. The advantage of two distinct measurements (acoustic and thermometric) provides a useful method of calibration that is unavailable to current LCLS diagnostics tools.

Bentsen, Gregory↗

Optimal Model-Based Fault Estimation and Correction for Particle Accelerators and Industrial Plants Using Combined Support Vector Machines and First Principles Models

Timely estimation of deviations from optimal performance in complex systems and the ability to identify corrective measures in response to the estimated parameter deviations has been the subject of extensive research over the past four decades. The implications in terms of lost revenue from costly industrial processes, operation of large-scale public works projects and the volume of the published literature on this topic clearly indicates the significance of the problem. Applications range from manufacturing industries (integrated circuits, automotive, etc.), to large-scale chemical plants, pharmaceutical production, power distribution grids, and avionics. In this project we investigated a new framework for building parsimonious models that are suited for diagnosis and fault estimation of complex technical systems. We used Support Vector Machines (SVMs) to model potentially time-varying parameters of a First-Principles (FP) description of the process. The combined SVM & FP model was built (i.e. model parameters were trained) using constrained optimization techniques. We used the trained models to estimate faults affecting simulated beam lifetime. In the case where a large number of process inputs are required for model-based fault estimation, the proposed framework performs an optimal nonlinear principal component analysis of the large-scale input space, and creates a lower dimension feature space in which fault estimation results can be effectively presented to the operation personnel. To fulfill the main technical objectives of the Phase I research, our Phase I efforts have focused on: (1) SVM Training in a Combined Model Structure - We developed the software for the constrained training of the SVMs in a combined model structure, and successfully modeled the parameters of a first-principles model for beam lifetime with support vectors. (2) Higher-order Fidelity of the Combined Model - We used constrained training to ensure that the output of the SVM (i.e. the parameters of the beam lifetime model) are physically meaningful. (3) Numerical Efficiency of the Training - We investigated the numerical efficiency of the SVM training. More specifically, for the primal formulation of the training, we have developed a problem formulation that avoids the linear increase in the number of the constraints as a function of the number of data points. (4) Flexibility of Software Architecture - The software framework for the training of the support vector machines was designed to enable experimentation with different solvers. We experimented with two commonly used nonlinear solvers for our simulations. The primary application of interest for this project has been the sustained optimal operation of particle accelerators at the Stanford Linear Accelerator Center (SLAC). Particle storage rings are used for a variety of applications ranging from 'colliding beam' systems for high-energy physics research to highly collimated x-ray generators for synchrotron radiation science. Linear accelerators are also used for collider research such as International Linear Collider (ILC), as well as for free electron lasers, such as the Linear Coherent Light Source (LCLS) at SLAC. One common theme in the operation of storage rings and linear accelerators is the need to precisely control the particle beams over long periods of time with minimum beam loss and stable, yet challenging, beam parameters. We strongly believe that beyond applications in particle accelerators, the high fidelity and cost benefits of a combined model-based fault estimation/correction system will attract customers from a wide variety of commercial and scientific industries. Even though the acquisition of Pavilion Technologies, Inc. by Rockwell Automation Inc. in 2007 has altered the small business status of the Pavilion and it no longer qualifies for a Phase II funding, our findings in the course of the Phase I research have convinced us that further research will render a workable model-based fault estimation and correction for particle accelerators and industrial plants feasible.

43 PARTICLE ACCELERATORS↗

IR Bandwidth and Crystal Thickness Effects on THG Efficiency and Temporal Shaping of Quasi-Rectangular UV Pulses: Part II - Incident IR Ripple

We have investigated the effect of incident ir spectral bandwidth and crystal thickness, on uv pulses produced by third harmonic generation (THG) in a crystal pair. Our focus is on the third harmonic generation efficiency and longitudinal uv intensity profile parameters of SNLO predictions that are evaluated for three incident ir spectral bandwidths and a range of crystal thicknesses. These results represent a continuation of earlier work in which the effects of the same selected ir bandwidths and range of crystal thicknesses were investigated using a pair of BBO Type I crystals in a simplistic geometry for which the longitudinal intensity plateau has a zero slope, 'flattop' profile. The current work is distinguished from the previous work by an imposed ripple on the ir intensity longitudinal profile and constitutes a portion of a Part II effort to which we have made reference. As with preceding work, all third harmonic data are net results at the exit of the second BBO crystal. Predictions are obtained with the modified SNLO code developed by Arlee Smith at the Sandia National Laboratories. This modification has allowed us to pursue the 'coupled' case in which the output of the first BBO crystal is used as input to the second one. This includes both the fundamental and second harmonic light. Defined parameters are consistent with previous work. The presented cases are best results. The criteria for selection of these reported cases are highest THG efficiency combined with minimum intensity ripple in the plateau. The incident ir pulse is quasi-rectangular with an imposed 5.2 % (rms) intensity ripple added to the plateau. The ir pulse bandwidth is centered at 800 nm. Second harmonic generation occurs in the first BBO crystal and THG occurs in the second crystal as a consequence of sum frequency generation. Type I phase matching is used throughout, so that for a negative uniaxial crystal: n{sub 2}{sup e}({theta}) = n{sub 1}{sup o};(SHG) (1.1) 3n{sub 3}{sup 3}({theta}) = 2n{sub 2}{sup o} + n{sub 1}{sup o};(THG) where n{sub 2}{sup e}({theta}) and n{sub 3}{sup e}({theta}) are the angle dependent extraordinary refractive indices for the second and third harmonics respectively, and n{sub 1}{sup 1} and n{sub 2}{sup o} are the ordinary refractive indices for the fundamental and second harmonic respectively. Although our goal at this stage has not been to comply with all the LCLS injector laser specifications, the results provided here represent a parameter study that can be used to determine candidate bandwidth dependent, crystal thickness combinations for the detailed design of compliant THG subsystems. This simplistic geometry better elucidates acceptance bandwidth limitations that are intrinsic to the crystal material.

43 PARTICLE ACCELERATORS↗

QM02 Strength Measurement

In late April, Paul Emma reported that his orbit fitting program could find a reasonably good fit only if the strength of QM02 was changed from design value of -5.83 kG to -6.25 kG - a strength change of 7.3%. In late May, we made a focal length measurement of QM02 by turning off all focusing optics between YC07 and BPMS1 (in the spectrometer line) except for QM02 and adjusted the strength of QM02 so that vertical kicks by YC07 did not produce any displacements at BPMS1 (see Figure 1). The result was quoted in the LCLS elog was that QM02 appeared to 6% too weak, and approximately agreed with Paul's observation. The analysis used for the entry in the log book was based on the thin lens approximation and used the following numbers: Distance YC07 to QM02 - 5.128 m; Distance QM02 to BPMS1 - 1.778 m; and Energy - 135 MeV. These distances were computed from the X,Z coordinates given the on the large plot of the Injector on the wall of the control room. On review of the MAD output file coordinates, it seems that the distance used for QM02 to BPMS1 is not 1.778 m. The correct value is Distance, center of QM02 to BPMS1 - 1.845 m. There may be a typo on the wall chart values for the coordinates of BPMS1, or perhaps there was a misinterpretation of edge versus center of QM02. In any case, the effect of this change is that the thin lens estimate changes from 6% too weak to 9% too weak. At John Galayda's suggestion, we looked into the thin lens versus thick lens approximation. A Mathematica program was written to solve for the K value of the QM02, in the thick lens approximation, that provides point to point focusing from YC07 to BPMS1, and to compare this number with the value obtained using the thin lens approximation. The length of QM02 used in the thick lens calculation is the effective length determined by magnetic measurements of 0.108 m. The result of the Mathematica calculation is that the thin lens approximation predicts less magnet strength is required to produce the same focusing by about 1.3%. When both the distance correction and the thick lens approximation are taken into account, the result is: K{sub thick} - K{sub mm}/K{sub thick} = -7.6% where K{sub mm} is the value obtained from magnetic measurements and K{sub thick} is the value of K obtained from the focal length measurement in the thick lens approximation. That is, QM02 acts weaker than it was measured by magnetic measurements by 7.6%. This is remarkably close to Paul's original estimate. The unexpected weakness could in principle be due to several things: shorted turns, a current calibration error, magnetic measurement error; it could even be due to the presence of an gradient from QM01, which is of opposite sign and right next to QM02, despite it being set to zero current (although it was not DAC-zeroed). Plans have been implemented to remove and replace QM02 at the earliest ROD.

43 PARTICLE ACCELERATORS↗

Cold Test Measurements on the GTF Prototype RF Gun

The SSRL Gun Test Facility (GTF) was built to develop a high brightness electron injector for the LCLS and has been operational since 1996. Based on longitudinal phase space measurements showing a correlated energy spread the gun was removed and re-characterized in 2002. The low power RF measurements performed on the gun are described below. Perturbative bead measurements were performed to determine the field ratio in the two-cell gun, and network analyzer measurements were made to characterize the mode structure. A second probe was installed to monitor the RF field in the first cell, and a diagnostic was developed to monitor the high-power field ratio. Calibration of the RF probes, a model for analyzing RF measurements, and Superfish simulations of bead and RF measurements are described.

43 PARTICLE ACCELERATORS↗

Summary of QM02 Measurements

This note summarizes both the beam-based and various laboratory measurements of quadrupole magnets, units 387 and 428, used for QM02 in the LCLS Injector. These were undertaken because of a consistent discrepancy between accelerator model predictions and beam observations which seemed to indicate a weak QM02. A report 'QM02 Strength Measurement', by Welch and Wu, describes the discrepancy and beam-based measurements on unit 387. Subsequently, unit 387 was replaced by unit 428, refinements were made to analysis of the beam-based measurements were made, and additional magnetic measurements were made on unit 387 in the lab. These new results are summarized in this note. The principle results are: (1) Laboratory measurements of integrated gradient for the same magnet, or for different magnets of the same type, are all within 1% of each other at gradients of interest. These cases cover three independent types of measurements, disassembly/reassembly of the units, and extended periods of time between measurements. (2) Standardization, or lack thereof, can cause integrated gradient errors of approximately 0.2 kG, which can amount to a few percent of the strength of the magnet depending on the setting. (3) Model-independent beam-based measurements indicate the magnets are actually weaker than expected by about 2 percent, but these measurements are subject to the uncertainty of the BPMS1 location. (4) The standardization cycle is effective. (5) The stainless steel BPM vacuum chamber inside the magnets has no significant effect on the beam. The discrepancy between the accelerator model predictions and the actual orbit response is not resolved, but the evidence points away from magnetic strength errors as the source. Differences between the model locations and effective locations of BPM's is a possible culprit. This idea is explored in Section 2. Table 1 summarizes the measurement activities that were performed on the units. The dates listed correspond to the date when the relevent series of runs was completed.

43 PARTICLE ACCELERATORS↗

Space-Charge Effects in a Gas Detector

Discussion of space-charge effects in a photoluminescence cell that will be used as a nondisruptive total energy monitor at the LCLS facility is presented. Regimes where primary photoelectrons will be confined within the X-ray beam aperture are identified. Effects of the space-charge on the further evolution of the electron and ion populations are discussed. Parameters of the afterglow plasma are evaluated. Conditions under which the detector output will be proportional to the pulse energy are defined.

43 PARTICLE ACCELERATORS↗

Transmission Grating Measurements of Undulator K

This study was undertaken to understand the practicalities of determine K differences in the undulator modules by measuring single-shot x-ray spectra of the spontaneous radiation with a transmissive grating spectrometer under development to measure FEL spectra. Since the quality of the FEL is dependent on a uniform K value in all the undulator modules, being able to measure the relative undulator K values is important. Preliminary results were presented in a presentation, 'Use of FEL Off-Axis Zone Plate Spectrometer to Measure Relative K by the Pinhole/Centroid Method', at the 'LCLS Beam-Based Undulator K Measurements Workshop' on November 14, 2005 (UCRL-PRES-217281). This study applies equally well to reflective gratings of the appropriate period and inclinations.

43 PARTICLE ACCELERATORS↗

Practical application of cross correlation technique to measure jitter of master-oscillator-power-amplifier laser system

The Linac coherent light source (LCLS) at the SLAC National Accelerator Laboratory (SLAC) is the world’s first hard X-ray free electron laser (XFEL) and is capable of producing high-energy, femtosecond duration X-ray pulses. A common technique to study fast timescale physical phenomena, various “pump/probe” techniques are used. In these techniques there are two lasers, one optical and one X-ray, that work as a pump and as a probe to study dynamic processes in atoms and molecules. In order to resolve phenomena that occur on femtosecond timescales, it is imperative to have very precise timing between the optical lasers and X-rays (on the order of ~ 20 fs or better). The lasers are synchronized to the same RF source that drives the accelerator and produces the X-ray laser. However, elements in the lasers cause some drift and time jitter, thereby de-synchronizing the system. This paper considers cross-correlation technique as a way to quantify the drift and jitter caused by the regenerative amplifier of the ultrafast optical laser.

cross-correlation↗

Thin-Entrance Window Process for Soft X-Ray Sensors

New free electron lasers, such as SLAC’s LCLS-II, will provide unique scientific imaging opportunities. In order to fully utilize these facilities, we need to develop detectors with shallow entrance windows that will enable detection of soft x-rays from 250 eV to 1.5 KeV. Achieving adequately shallow entrance windows is challenging because the high temperature anneal needed to activate the dopant also drives the dopant profile deeper, growing the region that is insensitive to soft x-rays. A new microwave annealing technology provides an efficient way to achieve shallow entrance windows in fully depleted high-resistivity silicon sensors. The microwave anneal technique can activate dopants at low substrate temperature, with minimal dopant diffusion, and can be used to fabricate both n-type and p-type entrance windows. SRP and SIMS measurements were used to verify dopant activation with negligible dopant diffusion. We then applied the microwave anneal process to a planar sensor wafer, using the new process to create the backside diode contact. Electrical test of the resulting sensors shows good reverse bias characteristics. The sensors have been bump-bonded to a read-out ASIC and used successfully to measure an Fe-55 x-ray spectrum. Process and device simulations were performed to characterize the quantum efficiency of the entrance window for soft x-rays. This technique is useful for other sensor applications requiring a shallow entrance window, including detectors for UV photons, low energy ions and low energy electrons.

47 OTHER INSTRUMENTATION↗

Electron-Ion Temperature Relaxation in Warm Dense Hydrogen Observed With Picosecond Resolved X-Ray Scattering

Angularly resolved X-ray scattering measurements from fs-laser heated hydrogen have been used to determine the equilibration of electron and ion temperatures in the warm dense matter regime. The relaxation of rapidly heated cryogenic hydrogen is visualized using 5.5 keV X-ray pulses from the Linac Coherent Light (LCLS) source in a 1 Hz repetition rate pump-probe setting. We demonstrate that the electron-ion energy transfer is faster than quasi-classical Landau-Spitzer models that use ad hoc cutoffs in the Coulomb logarithm.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Data reduction through optimized scalar quantization for more compact neural networks

Raw data generation for several existing and planned large physics experiments now exceeds TB/s rates, generating untenable data sets in very little time. Those data often demonstrate high dimensionality while containing limited information. Meanwhile, Machine Learning algorithms are now becoming an essential part of data processing and data analysis. Those algorithms can be used offline for post processing and post data analysis, or they can be used online for real time processing providing ultra low latency experiment monitoring. Both use cases would benefit from data throughput reduction while preserving relevant information: one by reducing the offline storage requirements by several orders of magnitude and the other by allowing ultra fast online inferencing with low complexity Machine Learning models. Moreover, reducing the data source throughput also reduces material cost, power and data management requirements. In this work we demonstrate optimized nonuniform scalar quantization for data source reduction. This data reduction allows lower dimensional representations while preserving the relevant information of the data, thus enabling high accuracy Tiny Machine Learning classifier models for online fast inferences. We demonstrate this approach with an initial proof of concept targeting the CookieBox, an array of electron spectrometers used for angular streaking, that was developed for LCLS-II as an online beam diagnostic tool. We used the Lloyd-Max algorithm with the CookieBox dataset to design an optimized nonuniform scalar quantizer. Optimized quantization lets us reduce input data volume by 69% with no significant impact on inference accuracy. When we tolerate a 2% loss on inference accuracy, we achieved 81% of input data reduction. Finally, the change from a 7-bit to a 3-bit input data quantization reduces our neural network size by 38%.

97 MATHEMATICS AND COMPUTING↗

Microscopy X-ray imaging enriched with small angle X-ray scattering for few nanometer resolution reveals shock waves and compression in intense short pulse laser irradiation of solids

Understanding how laser pulses compress solids into high-energy-density states requires diagnostics that simultaneously resolve macroscopic geometry and nanometer-scale structure. Here we present a combined X-ray imaging (XRM) and small-angle X-ray scattering (SAXS) approach that bridges this diagnostic gap. Using the Matter in Extreme Conditions end station at LCLS, we irradiated 25 μm copper wires with 45 fs, 0.9 J, 800 nm pulses at 3.5 × 10 19 W/cm 2 while probing with 8.2 keV XFEL pulses. XRM visualizes the evolution of ablation, compression, and inward-propagating fronts with ∼ 200 nm resolution, while SAXS quantifies their nanometer-scale sharpness via the time-resolved evolution of scattering streaks. The joint analysis reveals that an initially smooth compression steepens into a nanometer-sharp shock front after t sh ≈ (18 ± 3) ps, consistent with an analytical steepening model and hydrodynamic simulations. The front reaches a velocity of c sh ≈ 25 k m / s and a lateral width of several tens of microns, demonstrating direct observation of shock formation and decay at solid density for the first time with few-nanometer precision. This integrated XRM–SAXS method establishes a quantitative, multi-scale diagnostic of laser-driven shocks in dense plasmas relevant to inertial confinement fusion, warm dense matter, and planetary physics.

Kluge, Thomas [Helmholtz-Zentrum Dresden-Rossendor↗

Case Study of High-Throughput Drug Screening and Remote Data Collection for SARS-CoV-2 Main Protease by Using Serial Femtosecond X-ray Crystallography

Since early 2020, COVID-19 has grown to affect the lives of billions globally. A worldwide investigation has been ongoing for characterizing the virus and also for finding an effective drug and developing vaccines. As time has been of the essence, a crucial part of this research has been drug repurposing; therefore, confirmation of in silico drug screening studies have been carried out for this purpose. Here we demonstrated the possibility of screening a variety of drugs efficiently by leveraging a high data collection rate of 120 images/second with the new low-noise, high dynamic range ePix10k2M Pixel Array Detector installed at the Macromolecular Femtosecond Crystallography (MFX) instrument at the Linac Coherent Light Source (LCLS). The X-ray Free-Electron Laser (XFEL) is used for remote high-throughput data collection for drug repurposing of the main protease (Mpro) of SARS-CoV-2 at ambient temperature with mitigated X-ray radiation damage. We obtained multiple structures soaked with nine drug candidate molecules in two crystal forms. Although our drug binding attempts failed, we successfully established a high-throughput Serial Femtosecond X-ray crystallographic (SFX) data collection protocol.

60 APPLIED LIFE SCIENCES↗

Measurements of Long-range Electronic Correlations During Femtosecond Diffraction Experiments Performed on Nanocrystals of Buckminsterfullerene

The precise details of the interaction of intense X-ray pulses with matter are a topic of intense interest to researchers attempting to interpret the results of femtosecond X-ray free electron laser (XFEL) experiments. An increasing number of experimental observations have shown that although nuclear motion can be negligible, given a short enough incident pulse duration, electronic motion cannot be ignored. The current and widely accepted models assume that although electrons undergo dynamics driven by interaction with the pulse, their motion could largely be considered 'random'. This would then allow the supposedly incoherent contribution from the electronic motion to be treated as a continuous background signal and thus ignored. The original aim of our experiment was to precisely measure the change in intensity of individual Bragg peaks, due to X-ray induced electronic damage in a model system, crystalline C 60 . Contrary to this expectation, we observed that at the highest X-ray intensities, the electron dynamics in C 60 were in fact highly correlated, and over sufficiently long distances that the positions of the Bragg reflections are significantly altered. Our paper describes in detail the methods and protocols used for these experiments, which were conducted both at the Linac Coherent Light Source (LCLS) and the Australian Synchrotron (AS) as well as the crystallographic approaches used to analyse the data.

43 PARTICLE ACCELERATORS↗

Combining Particle Tracking with Electromagnetic Radiation Showers: Merging GPT and Geant4 with Visualization

Field emitted electrons can seriously affect the operation of high-field, high-duty factor electron accelerators. Accelerated field emission can result in high average power beams which can radiation damage beamline components. In addition, localized losses generate thermal hot spots whose outgassing degrades the ultra-high vacuum required in photoinjectors and cryomodules. However, despite their importance, the effects of field emission are rarely included in the design and engineering of electron injectors. This work attempts to remedy this situation by combining two well-known and well-documented programs, GPT and Geant4, to track electrons and their losses in an injector beamline. This paper describes a system of programs which simulates electron paths and losses along the beamline. In addition, the tracking results can be zoomed and panned along and about the beampipe envelope using an open-source 3D CAD program. The scattering albedo calculations of the combined program, GPT-Geant4, are shown to be in good agreement with the literature albedos. The paper concludes with a dark current simulation for the LCLS-II injector from the cathode to the collimator at 1.5 m from the cathode.

Dowell, David H.↗

Second-order microscopic nonlinear susceptibility in a centrosymmetric material: application to imaging valence electron motion

We report measurements of phase-matched nonlinear x-ray and optical sum-frequency generation from single-crystal silicon using sub-resonant 0.95 eV laser pulses and 9.5 keV hard x-ray pulses from the LCLS free-electron laser. The sum-frequency signal appears as energy and momentum sidebands to the elastic Bragg peak. It is proportional to the magnitude squared of the relevant temporal and spatial Fourier components of the optically induced microscopic charges/currents. We measure the first- and second-order sideband to the 220 Bragg peak and find that the efficiency is maximized when the applied field is along the reciprocal lattice vector. For an optical intensity of $\sim10^{12} \text{W}/\text{cm}^2$, we measure peak efficiencies of $3\times 10^{-7}$ and $3\times 10^{-10}$ for the first and second-order sideband respectively (relative to the elastic Bragg peak). The first-order sideband is consistent with induced microscopic currents along the applied electric field (consistent with an isotropic response). The second-order sideband depends nontrivially on the optical field orientation and is consistent with an anisotropic response originating from induced charges along the bonds with C$_{3v}$ site symmetry. The results agree well with first-principles Bloch-Floquet calculations.

FOS: Physical sciences↗

Two techniques for mapping and area estimation of small grains in California using Landsat digital data

Two techniques have been developed for the mapping and area estimation of small grains in California from Landsat digital data. The two techniques are Band Ratio Thresholding, a semi-automated version of a manual procedure, and LCLS, a layered classification technique which can be fully automated and is based on established clustering and classification technology. Preliminary evaluation results indicate that the two techniques have potential for providing map products which can be incorporated into existing inventory procedures and automated alternatives to traditional inventory techniques and those which currently employ Landsat imagery.

Sheffner, E. J.↗