Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Instruments”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 883 records · Page 49

Resolve instrument onboard the X-Ray Imaging and Spectroscopy Mission

We present an overview of the design and in-flight performance of the Resolve soft X-ray spectrometer on the X-Ray Imaging and Spectroscopy Mission that was successfully launched on September 7, 2023, on a JAXA H-IIA rocket from the Tanegashima Space Center of Japan. The instrument has a 36-pixel array of microcalorimeters, 35 of which are at the focus of a high-throughput grazing-incidence X-ray mirror. The instrument has achieved its required operational base temperature of 0.05 K and a spectral resolution of 4.5 eV (FWHM) at 6 keV. The cooling chain was designed to provide a lifetime of at least 3 years in orbit and operate with and without liquid helium to provide redundancy and the longest operational lifetime for the instrument. Early indications are that the cryogen lifetime may reach 6 years with a cryogen-free mode thereafter. A series of onboard X-ray calibration sources produces energy scale calibration lines simultaneously while observing celestial sources. The overall design and in-flight performance of Resolve are described.

Astronomy and AstroPhysics↗

Separation of continuous lines mutually overlapping and smoothed by the instrumental function

Direct and inverse spectroscopy problems concerning superposition of overlapping continuous spectral lines, as well as smoothing of the total spectrum by the instrumental function, are considered. The direct problem is formulated in two stages: initially, the total spectrum is formed by lines with a given intensity distribution, and, then, a smoothed by the spectrometer instrumental function and noisy spectrum is obtained. The inverse problem is also formulated in two stages: initially, the Fredholm integral equation of the first kind is solved by the Tikhonov regularization method (an ill-posed problem), and, then, the problem of reconstruction of separate line-component shapes from the total spectrum is solved, which is the problem of line separation (division). The individual line components are modeled by Gaussians and Lorentzians. Numerical illustrations are shown. Gaussian and dispersion (Lorentz) instrumental functions are considered.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Cross-instrument Analysis Correlation Software

This program has been designed to assist with the tracking of a sample from one analytical instrument to another such as SEM, microscopes, micro x-ray diffraction and other instruments where particular positions/locations on the sample are examined, photographed, etc. The software is designed to easily enter the position of fiducials and locations of interest such that in a future session in the same of different instrument the positions of interest can be re-found through using the known location fiducials in the current and reference session to transform the point into the current sessions coordinate system. The software is dialog box driven guiding the user through the necessary data entry and program choices. Information is stored in a series of text based extensible markup language (XML) files.

McJunkin, TimothyR.↗

Developing Spent Fuel Assembly for Advanced NDA Instrument Calibration - NGSI Spent Fuel Project

This report summarizes the work by Oak Ridge National Laboratory to investigate the application of modeling and simulation to support the performance assessment and calibration of the advanced nondestructive assay (NDA) instruments developed under the Next Generation Safeguards Initiative Spent Fuel (NGSI-SF) Project. Advanced NDA instrument calibration will likely require reference spent fuel assemblies with well-characterized nuclide compositions that can serve as working standards. Because no reference spent fuel standard currently exists, and the practical ability to obtain direct measurement of nuclide compositions using destructive assay (DA) measurements of an entire fuel assembly is prohibitive in the near term due to the complexity and cost of spent fuel experiments, modeling and simulation will be required to construct such reference fuel assemblies. These calculations will be used to support instrument field tests at the Swedish Interim Storage Facility (Clab) for Spent Nuclear Fuel.

Hu, Jianwei↗

Aethalometer™ Instrument Handbook

The Aethalometer is an instrument that provides a real-time readout of the concentration of “Black” or “Elemental” carbon aerosol particles (BC or E) in an air stream (see Figure 1 and Figure 2). It is a self-contained instrument that measures the rate of change of optical transmission through a spot on a filter where aerosol is being continuously collected and uses the information to calculate the concentration of optically absorbing material in the sampled air stream. The instrument measures the transmitted light intensities through the “sensing” portion of the filter, on which the aerosol spot is being collected, and a “reference” portion of the filter as a check on the stability of the optical source. A mass flowmeter monitors the sample air flow rate. The data from these three measurements is used to determine the mean BC content of the air stream.

54 ENVIRONMENTAL SCIENCES↗

Gearbox Instrumentation for the Investigation of Bearing Axial Cracking

Failures in gearbox bearings have been the primary source of reliability issues for wind turbine drivetrains, leading to costly downtime and unplanned maintenance. The most common failure mode is attributed to so-called axial cracks or white-etching cracks, which primarily affect the intermediate and high-speed-stage bearings. The high-speed-shaft and bearing loads and sliding will be measured with a specially instrumented gearbox installed in a 1.5-megawatt turbine at the National Wind Technology Center in an upcoming test campaign. Additional instrumentation will also measure the tribological environment of these bearings, including bearing temperatures, lubricant temperature and water content, air temperature and humidity, and stray electrical current across the bearings. This paper fully describes the instrumentation package and summarizes initial results.

17 WIND ENERGY↗

Light Water Reactor Sustainability Program Advanced Instrumentation, Information, and Control Systems Technologies Technical Program Plan for FY 2018

This report presents the Technical Program Plan for FY 2018 for the Department of Energy Light Water Reactor Sustainability Program – Advanced Instrumentation, Information, and Control (II&C) Systems Technologies research pathway. A summary of the vision and strategy is provided to explain how this program addresses key issues and barriers for implementing digital instrumentation and control technologies in domestic nuclear power plants. The report describes 20 pilot projects that have been formulated to develop and validate enabling technologies over a 16 year period that will result in digital alternatives to the legacy analog II&C systems in place today. This will allow much needed modernization of these systems to address reliability and obsolescence problems, as well as serve as a platform for substantial operational improvement. The report further describes key project resources and cooperative relationships, including the Electric Power Research Institute, the Nuclear Energy Institute (NEI), the Institute of Nuclear Power Operations (INPO)the Nuclear Energy Institute )NEI), the Institute of Nuclear Power Operations (INPO), the IFE Halden Reactor Project, the Nuclear Regulatory Commission, and industry suppliers, that are instrumental to the success of the program. The report also lists the schedule for all program products, including the titles and report numbers for all published reports under this program.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Cloud Condensation Nuclei Particle Counter Instrument Handbook - Airborne Version

The cloud condensation nuclei counter (CCN) is a U.S. Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) user facility instrument for measuring the concentration of aerosol particles that can act as cloud condensation nuclei. Note: ARM deploys both ground and airborne versions of this instrument. This handbook covers only the airborne instrument; the ground version is covered by DOE/SC-ARM-TR-168. The main differences between the two are that the airborne CCN operates at fixed supersaturation and adapts thermal efficiency calculation in the data process. The CCN draws sample aerosol through a column with thermodynamically unstable supersaturated water vapor that can condense onto aerosol particles. Particles that are activated, i.e., grown larger in this process, are counted (and sized) by an optical particle counter (OPC). Thus, activated ambient aerosol particle number concentration as a function of supersaturation is measured. Models CCN-100 and CCN- 200 differ only in the number of humidifier columns and related subsystems: CCN-100 has one column and CCN-200 has two columns along with dual flow systems and electronics.

54 ENVIRONMENTAL SCIENCES↗

Low-Activity Waste Glass Standards Preparation and Characterization for Calibration of Analytical Instruments

A matrix of seven low-activity waste (LAW) glasses was fabricated and characterized to be used by the Hanford Waste Treatment and Immobilization Plant (WTP) as analytical instrument calibration and matrix interference standards when measuring LAW glass compositions. The matrix of glasses was designed to represent the range of LAW glass compositions that will be generated by the WTP. Samples from each of the seven glasses were measured with electron probe microanalysis (EPMA), ion chromatography (IC), and bulk inductively coupled plasma mass spectroscopy (ICP-MS) to determine the variability and accuracy across batches and within individually poured glass bar samples. High relative percent differences and standard deviations were calculated for components with low concentrations due to instrument detection limits. IC and ICP-MS percent differences and standard deviations were higher at low component concentrations. Otherwise, variability in measured compositions from IC and ICP-MS was generally lower than measurements from EPMA, with the exclusion of Cl, F, Si, and B. Overall, the two methods proved comparable and complementary. From EPMA, IC, and ICP-MS data, volatile elements were underrepresented compared to batched compositions, which suggested loss of these elements during melting. EPMA data was statistically analyzed to evaluate homogeneity within single bars and whole compositions for each of the seven glasses. Most of the variability within glass compositions occurred at the bar-to-bar level; however, no clear systematic trends were observed. Based on these analyses, when using these glasses as reference material, it is recommended that the overall mean and variance of each composition be used for performing instrument calibrations and analytical corrections.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Data Fusion to Enhance Quality Control and Analysis with Instruments at the Marine and Coastal Research Laboratory

Deploying environmental monitoring instruments in the marine environment can be challenging, facing challenges around device survivability, biofouling and corrosion, and consistent data collection. This project explores the use of data fusion – the process of integrating multiple data sources to produce more consistent, accurate, and useful information – to build a consistent long-term monitoring system at the Marine and Coastal Research Laboratory (MCRL) in Sequim, Washington. Unused instruments that had been acquired from past projects were inventoried and deployments planned on the MCRL pier and floating dock. A total of 8 instruments were deployed including a tide gauge, hydrophone, acoustic Doppler current profiler (ADCP), photosynthetically active radiation (PAR) sensors, meteorological station, and three water quality sensors. Deployments were planned to be well-protected around the pier structure and a maintenance schedule was created for cleaning and recalibration. An automated data pipeline was created to aggregate data on edge computers that push data to Amazon Web Services (AWS) cloud storage every 15 minutes, performing automated quality control and data transformations using the Time Series Data Analytical Toolkit (TSDAT). Continued efforts are underway to maintain this system into the future, take a data-driven approach to maintenance scheduling, improve the reliability of the system, and share the data with a variety of end-users.

54 ENVIRONMENTAL SCIENCES↗

Kilonova Detectability with Wide-Field Instruments

A diverse set of instruments increase the chances of detecting and identifying a kilonova. Early observations increase the probability of detection. More sensitive wide-field ultraviolet instruments are needed as GW detectors reach design sensitivity. There is a dearth of wide-field infrared instruments.

79 ASTRONOMY AND ASTROPHYSICS↗

Continuous Light Absorption Photometer (CLAP) Instrument Handbook

Reliable measurements of aerosol light absorption are crucial for quantifying the radiative forcing of climate. As a consequence, light absorption measurements are recommended for all stations in the Global Atmosphere Watch network, which is coordinated by the World Meteorological Organization. Aerosol light absorption is often dominated by soot-like particles produced by the incomplete combustion of carbonaceous fuels, commonly termed "black carbon", and optical methods are the primary way that equivalent black carbon concentrations are derived. Two basic approaches are used for determining the aerosol light absorption coefficient: in situ methods where the absorption is measured while the particles are suspended in air, and filter-based methods where the particles are deposited on a filter for real-time optical analysis. In situ methods are inherently more accurate because the physical state of the particles can be changed by the act of filtration. Unfortunately, currently available instruments for in situ measurements are more expensive and difficult to operate than filter-based methods, making them better suited for use in intensive field campaigns or as laboratory reference instruments. Filter-based instruments, because of their lower cost and simpler operation, have been the preferred choice for long-term measurements of aerosol light absorption in monitoring networks.

54 ENVIRONMENTAL SCIENCES↗

Analyze the Composition of Materials Through the Use of Characterization Instruments - CRADA 621 (Abstract)

The purpose of this project is to conduct collaborative research involving the analysis of the composition of materials using characterization instruments. The materials will be synthesized in the Nuclear Chemistry Facility in Fulmer Hall and analyzed using instruments both at WSU and PNNL. This research requires the use of several characterization instruments, namely a Biotage SEL-2SW Flash Chromatograph, a Jasco UV-Visible Near-IR V-770 spectrometer, and a Jasco FT/IT-6700 Research Spectrometer, in the Nuclear Chemistry Facility of the WSU-PNNL Nuclear Science and Technology Institute (NSTI) in Fulmer Hall on the WSU Pullman campus.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Ultra-black coatings for space instruments: a comparison of traditional Ebonol C processes and a method for future repeatability

Ultra-black coatings have served various roles in space instrumentation and hardware. The Ebonol C coating has been used for various missions requiring low reflectivity on aluminum substrates that are electrically conducting. This coating is produced through the formation of a cupric oxide structure on an intermediate layer of copper applied to the aluminum. For many years, this commercial formulation has been used ubiquitously for space instruments. The coating relies upon details of the copper base layer that have been trade secret at various finishing companies, and the availability of the Ebonol C formulated chemistry from the chemical supplier. In recent years, this product has been discontinued at various times, leaving vendors to either rely on expired stock or to formulate their own equivalents. Here, we detail the processing methods, chemistries, and resultant coating structures that produce reflectance performance equivalent to baseline historical reflectance data. This process detail will ensure equivalent performance for such coatings for future missions and link the performance to past and currently deployed instruments.

36 MATERIALS SCIENCE↗

Photosynthetically Active Radiation (PAR) Instrument Handbook

Three photosynthetically active radiation (PAR) measurement instruments were deployed at the U.S. Department of Energy Atmospheric Radiation Measurement (ARM) User Facility’s Bankhead National Forest (BNF) observatory, installed on three different instrument towers within the forest. Each of the three instruments comprises an enclosure at the base of the tower, containing a datalogger and internal humidity sensor, connected to external PAR sensors mounted at various heights and vertical orientations on the same tower. PAR sensors measure radiation reaching the sensor with wavelengths from 400-700 nm, per unit area, per unit time, or the photosynthetic photon flux density (PPFD, µmol photons m -2 s -1 ). On the 43-meter tower of BNF supplemental site S10, sensors are located 43 m, 22 m, 10 m, and 5 m from ground level. Downwelling radiation is measured with upward-facing sensors at all heights, and upwelling radiation is measured with downward-facing sensors at 43 m and 5 m. On the two 10-m towers of BNF supplemental sites S13 and S14, upwelling radiation is measured at 8 m and 2 m, and downwelling radiation is measured at 8 m.

54 ENVIRONMENTAL SCIENCES↗

SPRUCE Bog Surface Elevation Assessments with SPRUCE Elevation Transect Instrument, Marcell Experimental Forest, Minnesota, 2013-2025

This data set reports plot-specific bog surface elevation measurements collected with the SPRUCE Elevation Transect (SET) instrument at the Spruce and Peatland Responses Under Changing Environments (SPRUCE) experimental site within the Marcell Experimental Forest in northern Minnesota, USA. The SET instrument is a modified version of the Cahoon et al. (2002) surface elevation table instrument. The device is mounted to fixed stands that are anchored in deep sediments, making it capable of identifying subtle changes in bog surface elevation over time. Measurements are reported as absolute elevation in meters above mean sea level (amsl) for two locations in each of the SPRUCE experimental treatment plots and additional ambient boardwalk plots: 4, 5, 6, 7, 8, 9, 10, 11, 13, 14, 15, 16, 17, 19, 20 and 21. Measurements were collected from June 2013 through September 2025 (2013-06-02 to 2025-09-08). Changes in bog surface elevation may indicate alterations in the carbon and water cycles due to changing environmental conditions. This data set contains one data file in comma separate (*.csv) format. Additional metadata are provided: one data dictionary and a file-level metadata file in comma separate (.csv) format and a user guide in PDF (*.pdf) format.

54 ENVIRONMENTAL SCIENCES↗

Automated instrument for assessing abrasives

An automated instrument for monitoring the destructive compressive load on abrasive grains (measuring 400–1250 μm) between two rotating rollers has been developed. A modernized version of the instrument also permits determination of the grain size, shape, and microgeometric and topographic characteristics of abrasives. Equipped with a photometric unit and a module for processing numerical information, the modernized instrument permits multiple recording of each particle by six cameras (in both directions along three orthogonal axes), with assessment of the microgeometry. Such information regarding the grains, along with identification of their shape (plates, needles, isometric form, etc.), permits their quality assessment; their subsequent separation on vibrational sorters; and their most effective use in the abrasive machining of materials characterized by different hardness, brittleness, and composition, including composites.

36 MATERIALS SCIENCE↗

A New Field Instrument for Leaf Volatiles Reveals an Unexpected Vertical Profile of Isoprenoid Emission Capacities in a Tropical Forest

Both plant physiology and atmospheric chemistry are substantially altered by the emission of volatile isoprenoids (VI), such as isoprene and monoterpenes, from plant leaves. Yet, since gaining scientific attention in the 1950’s, empirical research on leaf VI has been largely confined to laboratory experiments and atmospheric observations. Here, we introduce a new field instrument designed to bridge the scales from leaf to atmosphere, by enabling precision VI detection in real time from plants in their natural ecological setting. With a field campaign in the Brazilian Amazon, we reveal an unexpected distribution of leaf emission capacities (EC) across the vertical axis of the forest canopy, with EC peaking in the mid-canopy instead of the sun-exposed canopy surface, and moderately high emissions occurring in understory specialist species. Compared to the simple interpretation that VI protect leaves from heat stress at the hot canopy surface, our results encourage a more nuanced view of the adaptive role of VI in plants. We infer that forest emissions to the atmosphere depend on the dynamic microenvironments imposed by canopy structure, and not simply on canopy surface conditions. We provide a new emissions inventory from 52 tropical tree species, revealing moderate consistency in EC within taxonomic groups. We highlight priorities in leaf volatiles research that require field-portable detection systems. Our self-contained, portable instrument provides real-time detection and live measurement feedback with precision and detection limits better than 0.5 nmol VI m -2 leaf s -1 . We call the instrument ‘PORCO’ based on the gas detection method: photoionization of organic compounds. We provide a thorough validation of PORCO and demonstrate its capacity to detect ecologically driven variation in leaf emission rates and thus accelerate a nascent field of science: the ecology and ecophysiology of plant volatiles.

54 ENVIRONMENTAL SCIENCES↗