Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ISOTOPE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 883 records · Page 49

Validation of Electrochemically Modulated Separations Performed On-Line with MC-ICP-MS for Uranium and Plutonium Isotopic Analyses

The most time consuming process in uranium or plutonium isotopic analyses is performing the requisite chromatographic separation of the actinides. Filament preparation for thermal ionization (TIMS) adds further delays, but is generally accepted due to the unmatched performance in trace isotopic analyses. Advances in Multi-Collector Inductively Coupled Plasma Mass Spectrometry (MC-ICP-MS) are beginning to rival the performance of TIMS. Methods, such as Electrochemically Modulated Separations (EMS) can efficiently pre-concentrate U or Pu quite selectively from small solution volumes in a matrix of 0.5 M nitric acid. When performed in-line with ICP-MS, the rapid analyte release from the electrode is fast, and large transient analyte signal enhancements of >100 fold can be achieved as compared to more conventional continuous nebulization of the original starting solution. This makes the approach ideal for very low level isotope ratio measurements. In this paper, some aspects of EMS performance are described. These include low level Pu isotope ratio behavior versus concentration by MC-ICP-MS and uranium rejection characteristics that are also important for reliable low level Pu isotope ratio determinations.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Process for the separation and purification of medical isotopes

The invention provides a method for isolating medical isotopes, the method having the steps of dissolving titanium nuclear targets to create a solution; contacting the solution with a resin so as to retain the isotopes on the resin and generate an eluent containing titanium; contacting the isotope-containing resin with acid of a first concentration to remove impurities from the resin; and contacting the isotope-containing resin with an acid of a second concentration to remove isotope from the resin.

07 ISOTOPE AND RADIATION SOURCES↗

Hydrogen isotope separation methods and systems

Methods and systems for the separation of hydrogen isotopes from one another are described. Methods include utilization of a hydrogen isotope selective separation membrane that includes a hydrogen isotope selective layer (e.g., graphene) and a hydrogen ion conductive supporting layer. An electronic driving force encourages passage of isotopes selectively across the membrane at an elevated separation temperature to enrich the product in a selected hydrogen isotope.

07 ISOTOPE AND RADIATION SOURCES↗

Natural mercury isotope variation in coal deposits and organic soils

There is a need to distinguish among sources of Hg to the atmosphere in order to more fully understand global Hg pollution. In this study we investigate whether coal deposits within the United States, China, and Russia-Kazakhstan, which are three of the five greatest coal-producing regions, have diagnostic Hg isotopic fingerprints that can be used to discriminate among Hg sources. We also investigate the Hg isotopic composition of modern organic soil horizons developed in areas distant from point sources of Hg in North America. Mercury stored in coal deposits displays a wide range of both mass dependent fractionation and mass independent fractionation. {delta}{sup 202}Hg varies in coals by 3{per_thousand} and {Delta}{sup 201}Hg varies by 0.9{per_thousand}. Combining these two Hg isotope signals results in what may be a unique isotopic 'fingerprint' for many coal deposits. Mass independent fractionation of mercury has been demonstrated to occur during photochemical reactions of mercury. This suggests that Hg found in most coal deposits was subjected to photochemical reduction near the Earth's surface prior to deposition. The similarity in MDF and MIF of modern organic soils and coals from North America suggests that Hg deposition from coal may have imprinted an isotopic signature on soils. This research offers a new tool for characterizing mercury inputs from natural and anthropogenic sources to the atmosphere and provides new insights into the geochemistry of mercury in coal and soils. 35 refs., 2 figs., 1 tab.

01 COAL, LIGNITE, AND PEAT↗

Hydrogen Isotope Separation from Aqueous Streams using Zeolite Membranes

Efficient separation of heavy hydrogen isotopes {sup 3}H (or T, tritium) and {sup 2}H (or D, deuterium) from {sup 1}H has been a long-standing endeavor in nuclear fuel cycle research and development. For example, tritium (half-life 12.3 years) is a fission product from nuclear plants and is found as tritiated water (HTO) in effluent streams from nuclear installations. Tritium must be concentrated and removed from such aqueous streams for waste storage. The separation of deuterium from deuterated water (HDO) has applications in heavy water production, and can also be used as a nonradioactive simulant in HTO separation research. Several methods have been explored such as ion exchange/adsorption and membrane permeation. Adsorption by molecular sieving materials such as zeolites can separate tritiated water from water with moderate selectivity (HTO/H{sub 2}O separation factor∼1.2-1.4) due to a subtle difference in adsorption characteristics between the two species. However, there remains a requirement for high-selectivity continuous separation of heavy hydrogen isotopes from water. Here we demonstrate new results on the use of zeolite membranes as a potential high-performance, low-cost, radiation-stable candidate for such separations. In zeolite membranes, separation of HTO (or HDO) from water would take place by a combination of adsorption and diffusion characteristics. Here we describe the hydrogen isotope separation properties of silicoaluminophosphate (SAPO-34) membranes synthesized on porous α-alumina supports. D{sub 2}O/H{sub 2}O feed mixtures of realistic compositions are used as a non-radioactive simulant for tritiated water feeds. Our results show promising applications of zeolite membranes for hydrogen isotope separation and recovery. In summary, SAPO-34 membranes were fabricated and investigated to demonstrate their pervaporative separation properties for D{sub 2}O-H{sub 2}O binary systems. These membrane exhibit high selectivity (up to ∼19) for D{sub 2}O and good permeance (> 600 GPU) even at low concentrations of D{sub 2}O in the feed, making them highly interesting candidates for capture of heavy hydrogen isotopes (D and T) from aqueous streams encountered in the nuclear fuel cycle. The mechanism of separation appears to involve both diffusivity and adsorption differences as expected in nanoporous materials, even though detailed identification of their respective contributions is a subject of future work. We also hypothesize that tritiated (T{sub 2}O/H{sub 2}O) mixtures will also show similar performance in relation to the present deuterated mixtures. This is planned to be further investigated through pervaporation measurements. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Accumulation of gadolinium isotopes in used nuclear fuel - 14374

For the criticality safety control of damaged nuclear fuel, i.e., fuel debris, accounting for burnup credit (BUC) may become important if higher initial-uranium-enrichment fuel almost 5 wt% loaded into the reactor. In this case, if the presence of fission products (FP) could be confirmed, the negative reactivity effect of FP allows us to treat a substantially greater quantity of fuel debris in one removal and storage operation. In the technical development of the criticality safety control for fuel debris from the Fukushima accident in Japan, adopting BUC assuming the presence of the FP is being considered because the fuel used in the Fukushima Daiichi Nuclear Power Plant had a higher initial {sup 235}U enrichment, i.e., almost 5 wt%, than the fuel used at TMI-2. The Expert Group on Burnup Credit Criticality Safety (EGBUC) under the Working Party on Nuclear Criticality Safety (WPNCS) in the OECD/NEA Nuclear Science Committee carried out international burnup calculation benchmarks 'Phase-IIIB' and 'Phase-IIIC' for BWR fuel assemblies. In these benchmarks, the differences in the {sup 155}Gd calculation results of the participants generated keen interest because these differences were rather large. As the coordinators of the Phase-IIIC benchmark, the authors have conducted additional analyses on the accumulation of the gadolinium isotopes in used nuclear fuel during burnup. Without cooling time, the assembly-averaged amount of {sup 155}Gd against the burnup value depends on the burnout property of gadolinium in burnable poison rods. This is because the amount of gadolinium isotopes accumulated owing to the fission reaction is less than the residual gadolinium in the burnable poison rods. After the burnout of gadolinium isotopes in the burnable poison rods, the amount of {sup 155}Gd isotopes remains almost constant, which is defined by the balance between depletion due to the neutron capture reaction and generation due to beta-decay of {sup 155}Eu generated by the fission reaction. However, after a few years of cooling, the amount of {sup 155}Gd drastically increases owing to {sup 155}Eu decay. This effect is important for higher burnup fuel. In this case, the amount of gadolinium isotopes in the burnable poison rods is of less importance. This means that for better prediction of {sup 155}Gd, the adopted parameters and data pertaining to {sup 155}Eu generation have significantly greater importance than the burnup treatment of the burnable poison rods. The release behavior of europium as well as gadolinium during the severe accident should be examined. This paper provides basic information for considering {sup 155}Gd in the criticality safety evaluation of fuel debris. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Isotopic Constraints on the Chemical Evolution of Geothermal Fluids, Long Valley, CA

A spatial survey of the chemical and isotopic composition of fluids from the Long Valley hydrothermal system was conducted. Starting at the presumed hydrothermal upwelling zone in the west moat of the caldera, samples were collected from the Casa Diablo geothermal field and a series of monitoring wells defining a nearly linear, ~;;14 km long, west-to-east trend along the proposed fluid flow path (Sorey et al., 1991). Samples were analyzed for the isotopes of water, Sr, Ca, and noble gases, the concentrations of major cations and anions and total CO2. Our data confirm earlier models in which the variations in water isotopes along the flow path reflect mixing of a single hydrothermal fluid with local groundwater. Variations in Sr data are poorly constrained and reflect fluid mixing, multiple fluid-pathways or water-rock exchange along the flow path as suggested by Goff et al. (1991). Correlated variations among total CO2, noble gases and the concentration and isotopic composition of Ca suggest progressive fluid degassing (loss of CO2, noble gases) driving calcite precipitation as the fluid flows west-to-east across the caldera. This is the first evidence that Ca isotopes may trace and provide definitive evidence of calcite precipitation along fluid flow paths in geothermal systems.

15 GEOTHERMAL ENERGY↗

Experiment Isotopic Data Compiled by the OECD/NEA Expert Group on Assay Data for Spent Nuclear Fuel

An essential component of computational modeling and simulation is the availability of well-qualified experimental benchmark data against which calculation systems can be validated and the bias and uncertainty associated with the codes and data can be evaluated. The validation process is extremely important for safety and licensing to demonstrate that adequate margins for uncertainty have been included in the calculations. For safety evaluations involving spent nuclear fuel, the isotopic compositions and resulting activities calculated using depletion and decay codes must be validated against experimental determinations of the spent fuel content. In this process the isotopic concentrations predicted by the codes should be compared with corresponding measurements of spent fuel made by destructive analysis as a fundamental part of any code performance evaluation. In recent years there has been growing international interest in acquiring high-quality assay data that can be used to validate code calculations, particularly for modern fuel designs and high burnup fuels and for a wider range of nuclides important to nuclear criticality safety, radiological safety assessments, and decay heat. Assay data are required to validate a broad range of reactor and fuel-cycle applications, including reactor core simulation, postulated severe accident analysis, spent fuel handling, spent fuel transportation and interim storage, reprocessing, nuclear safeguards, and final fuel repository evaluations. In some cases researchers working on depletion code development have noted a general lack of available assay measurements that can be used to benchmark and validate their code calculations for spent fuel compositions. This perception is due in part to the fact that data have been reported in diverse publications over many years, many experimental reports are difficult to access, and there has not been a concerted and funded effort to compile and consolidate available measurements that can be easily accessed by code developers and analysts for validation. In response to the increased interest in fuel isotopic measurements and needs for consolidation and documentation of available data, an Expert Group on Assay Data for Spent Nuclear Fuel (EGADSNF) was formed in 2007 as a working group of the Organisation for Economic Cooperation and Development (OECD)/Nuclear Energy Agency (NEA) Working Party on Nuclear Criticality Safety (WPNCS). Although the group was formed by the Expert Group on Burnup Credit to coordinate isotopic assay data activities and facilitate collaboration between countries developing or implementing burnup credit in their nuclear criticality safety methodologies, the group recognized the need and value of assay data for a broad range of spent fuel applications, and the EGADSNF includes members representing not only the WPNCS, but also members from the standing technical Committee on the Safety of Nuclear Installations and the Integration Group for the Safety Case of the Radioactive Waste Management Committee. Member countries currently active in the EGADSNF include Belgium, the Czech Republic, France, Germany, Japan, Slovakia, Spain, Sweden, the United Kingdom, and the United States. The experimental database of spent fuel measurements maintained by the OECD/NEA is web-accessible. SFCOMPO (database of Spent Fuel Compositions) contains measured isotopic data, mostly for light water reactor (LWR) fuels, for about 250 fuel samples. This paper summarizes the status of SFCOMPO and current activities to expand and improve the database.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

System for recovery of daughter isotopes from a source material

A method of separating isotopes from a mixture containing at least two isotopes in a solution is disclosed. A first isotope is precipitated and is collected from the solution. A daughter isotope is generated and collected from the first isotope. The invention includes a method of producing an actinium-225/bismuth-213 product from a material containing thorium-229 and thorium-232. A solution is formed containing nitric acid and the material containing thorium-229 and thorium-232, and iodate is added to form a thorium iodate precipitate. A supernatant is separated from the thorium iodate precipitate and a second volume of nitric acid is added to the thorium iodate precipitate. The thorium iodate precipitate is stored and a decay product comprising actinium-225 and bismuth-213 is generated in the second volume of nitric acid, which is then separated from the thorium iodate precipitate, filtered, and treated using at least one chromatographic procedure. A system for producing an actinium-225/bismuth-213 product is also disclosed.

07 ISOTOPE AND RADIATION SOURCES↗

Production of Secondary Radioactive Beams of He and Li Neutron-Rich Isotopes in the Fragmentation Reaction {sup 15}N(47 MeV/A)+{sup 9}Be

Yields of neutron-rich isotopes of He and Li produced in the reaction {sup 15}N(47 MeV/A)+{sup 9}Be have been measured. The experiment was carried out at the fragment separator COMBAS of the Flerov Laboratory of Nuclear Reactions, JINR (Dubna). Ion beams accelerated with the U-400M cyclotron and thick target were used. The products were identified according to their magnetic rigidities and time of flight (TOF) via the separator. The path length of TOF was 7,5 m. As a result of fragmentation, beams of four isotopes of Lithium and two isotopes of Helium were obtained. The inclusive velocities of reaction products were obtained and isotopes yields were calculated.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

The influence of intruder states in even-even Po isotopes

We study the role of intruder states and shape coexistence in the even-even {sup 190–206}Po isotopes, through an interacting boson model with configuration mixing calculation. We analyzed the results in the light of known systematics on various observable in the Pb region, paying special attention to the unperturbed energy systematics and quadrupole deformation. We find that shape coexistence in the Po isotopes behaves in very much the same way as in the Pt isotopes, i.e., it is somehow hidden, contrary to the situation in the Pb and the Hg isotopes.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Isotope shifts and hyperfine structure of the Fe I 372-nm resonance line

We report measurements of the isotope shifts of the 3d{sup 6}4s{sup 2} a {sup 5}D{sub 4}-3d{sup 6}4s4p z {sup 5}F{sub 5}{sup o} Fe I resonance line at 372 nm between all four stable isotopes {sup 54}Fe, {sup 56}Fe, {sup 57}Fe, and {sup 58}Fe, as well as the complete hyperfine structure of that line for {sup 57}Fe, the only stable isotope having a nonzero nuclear spin. The field and specific mass shift coefficients of the transition have been derived from the data, as well as the experimental value for the hyperfine structure magnetic dipole coupling constant A of the excited state of the transition in {sup 57}Fe: A(3d{sup 6}4s4p z {sup 5}F{sub 5}{sup o})=81.69(86) MHz. The measurements were carried out by means of high-resolution Doppler-free laser saturated absorption spectroscopy in a Fe-Ar hollow cathode discharge cell using both natural and enriched iron samples. The measured isotope shifts and hyperfine constants are reported with uncertainties at the percent level.

74 ATOMIC AND MOLECULAR PHYSICS↗

Calculation of nucleon densities in calcium, nickel, and molybdenum isotopes on the basis of the dispersive optical model

The radial distributions of proton and neutron densities in the even–even isotopes {sup 40−70}Cа and {sup 48−78}Ni and the analogous distributions of neutron densities in the even–even isotopes {sup 92−138}Mo were calculated on the basis of the mean-fieldmodel involving a dispersive optical potential. The respective root-mean-square radii and neutron-skin thicknesses were determined for the nuclei under study. In N > 40 calcium isotopes, the calculated neutron root-mean-square radius exhibits a fast growth with increasing N, and this is consistent with the prediction of the neutron-halo structure in calcium isotopes near the neutron drip line.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Selective Gaseous Extraction: Research, Development and Training for Isotope Production, Final Technical Report

General Atomics and the University of Missouri Research Reactor (MURR) completed research and development of selective gaseous extraction of fission products from irradiated fuel, which included training and education of MURR students. The process used porous fuel and after irradiation flowed product gases through the fuel to selectively removed desired fission products with the primary goal of demonstrating the removal of rhodium 105. High removal rates for the ruthenium/rhodium (Ru/Rh), tellurium/iodine (Te/I) and molybdenum/technetium (Mo/Tc) series were demonstrated. The success of this research provides for the reuse of the target for further production, significantly reducing the production of actinide wastes relative to processes that dissolve the target. This effort was conducted under DOE funding (DE-SC0007772). General Atomics objective of the project was to conduct R&D on alternative methods to produce a number of radioactive isotopes currently needed for medical and industry applications to include rhodium-105 and other useful isotopes. Selective gaseous extraction was shown to be effective at removing radioisotopes of the ruthenium/rhodium, tellurium/iodine and molybdenum/technetium decay chains while having trace to no quantities of other fission products or actinides. This adds a new, credible method to the area of certain commercial isotope production beyond current techniques, while providing significant potential reduction of process wastes. Waste reduction, along with reduced processing time/cost provides for superior economic feasibility which may allow domestic production under full cost recovery practices. This provides the potential for improved access to domestically produced isotopes for medical diagnostics and treatment at reduced cost, providing for the public good.

07 ISOTOPE AND RADIATION SOURCES↗

Structure and superconductivity of isotope-enriched boron-doped diamond

Superconducting boron-doped diamond samples were synthesized with isotopes of {sup 10}B, {sup 11}B, {sup 13}C and {sup 12}C. We claim the presence of a carbon isotope effect on the superconducting transition temperature, which supports the 'diamond-carbon'-related nature of superconductivity and the importance of the electron-phonon interaction as the mechanism of superconductivity in diamond. Isotope substitution permits us to relate almost all bands in the Raman spectra of heavily boron-doped diamond to the vibrations of carbon atoms. The 500 cm{sup 01} Raman band shifts with either carbon or boron isotope substitution and may be associated with vibrations of paired or clustered boron. The absence of a superconducting transition (down to 1.6 K) in diamonds synthesized in the Co-C-B system at 1900 K correlates with the small boron concentration deduced from lattice parameters.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Discovery of the Isotopes with 11{<=}Z{<=}19

A total of 194 isotopes with 11{<=}Z{<=}19 have been identified to date. The discovery of these isotopes which includes the observation of unbound nuclei, is described. For each isotope a brief summary of the first refereed publication, including the production and identification method, is presented.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

IRON-60 HETEROGENEITY AND INCOMPLETE ISOTOPE MIXING IN THE EARLY SOLAR SYSTEM

Short-lived radionuclides (e.g., {sup 26}Al, {sup 53}Mn, {sup 60}Fe, {sup 182}Hf) are widely used to refine the chronology of the early solar system. They provide chronological information, however, only if they were homogeneously distributed in the source region of the objects under scrutiny at the time of their formation. With the high level of precision now achieved on isotopic measurements, very short time intervals can in principle be resolved and a precise evaluation of the initial homogeneity degree becomes increasingly crucial. High-precision nickel isotope data for differentiated meteorites (angrites, ureilites) and chondritic (CB) components allow us to test the initial distribution of radioactive {sup 60}Fe and stable Ni isotopes. Although these meteorites appear to have formed nearly contemporaneously, they yield variable initial {sup 60}Fe/{sup 56}Fe ratios. Besides, the CB metal nodules and ureilite silicates show nucleosynthetic anomalies. The new data presented here do not confirm the recently inferred late injection of {sup 60}Fe into the protoplanetary disk. Instead, live {sup 60}Fe was present, but heterogeneously distributed, from the start of the solar system, revealing an incomplete mixing of material from various nucleosynthetic sources and restricting the use of the {sup 60}Fe-{sup 60}Ni system as a chronometer.

79 ASTRONOMY AND ASTROPHYSICS↗

LITHIUM-BERYLLIUM-BORON ISOTOPIC COMPOSITIONS IN METEORITIC HIBONITE: IMPLICATIONS FOR ORIGIN OF {sup 10}Be AND EARLY SOLAR SYSTEM IRRADIATION

NanoSIMS isotopic measurements of Li, Be, and B in individual hibonite grains extracted from the Murchison meteorite revealed that {sup 10}B excesses correlate with the {sup 9}Be/{sup 11}B ratios in {sup 26}Al-free PLAty hibonite Crystals. From these data, an initial {sup 10}Be/{sup 9}Be = (5.5 {+-} 1.6) x 10{sup -4} (2{sigma}) and {sup 10}B/{sup 11}B = 0.2508 {+-} 0.0015 can be inferred. On the other hand, chondritic boron isotopic compositions were found in {sup 26}Al-bearing Spinel-HIBonite spherules, most likely due to contamination with normal boron. No {sup 7}Li excesses due to {sup 7}Be decay were observed. When combined with previously reported data, the new data yield the best defined {sup 10}Be/{sup 9}Be = (5.3 {+-} 1.0) x 10{sup -4} (2{sigma}) and {sup 10}B/{sup 11}B = 0.2513 {+-} 0.0012 for PLACs. A comparison of this value and the best constrained {sup 10}Be/{sup 9}Be = (8.8 {+-} 0.6) x 10{sup -4} in CV Ca-Al-rich inclusions supports a heterogeneous distribution of {sup 10}Be and its protosolar irradiation origin. We consider two possible irradiation scenarios that could potentially lead to the observed Li-Be-B isotopic compositions in PLACs. Although in situ irradiation of solids with hibonite chemistry seems to provide the simplest explanation, more high quality data will be needed for quantitatively constraining the irradiation history.

79 ASTRONOMY AND ASTROPHYSICS↗