Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “INTEGRAL DOSES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 883 records · Page 49

SU-E-T-794: Validation of the MCNPX Monte Carlo Model of the Ocular Beam Line at the Proton Therapy Center Houston

Purpose: The PTCH is preparing the ocular proton beam nozzle for clinical use. Currently commissioning measurements are being performed using films, diodes and ionization chambers. In parallel, a Monte Carlo model of the beam line was created for integration into the automated Monte Carlo treatment plan computation system, MC{sup 2}. This work aims to compare Monte Carlo predictions to measured proton doses in order to validate the Monte Carlo model. Methods: A complete model of the double scattering ocular beam line has been created and is capable of simulating proton beams with a comprehensive set of beam modifying devices, including eleven different range modulator wheels. Simulations of doses in water were scored and compare to ion chamber measurements of depth doses, lateral dose profiles extracted from half beam block exposures of films, and diode measurements of lateral penumbrae at various depths. Results: All comparison resulted in an average relative entrance dose difference of less than 3% and peak dose difference of less than 2%. All range differences were smaller than 0.2 mm. The differences in the lateral beam profiles were smaller than 0.2 mm, and the differences in the penumbrae were all smaller than 0.4%. Conclusion: All available data shows excellent agreement of simulations and measurements. More measurements will have to be performed in order to completely and systematically validate the model. Besides simulating and measuring PDDs and lateral profiles of all remaining range modulator wheels, the absolute dosimetry factors in terms of number of source protons per monitor unit have to be determined.

60 APPLIED LIFE SCIENCES↗

Electron spin resonance and photoluminescence in pyrolytic silicon nitride films irradiated with argon and molecular ions

The photoluminescence and electron spin resonance phenomena are studied at room temperature for pyrolytic silicon nitride films irradiated with argon ions or molecular nitrogen ions and annealed at temperatures in the range 500-1100{sup o}C. The absorption spectrum suggests that the broad photoluminescence band at 400-600 nm is due to electron transitions between the band tails. The low-dose irradiation with argon ions slightly reduces the photoluminescence intensity, whereas the high-dose irradiation followed by annealing at 800-900{sup o}C can induce a more than twofold increase in the intensity. At the same time, irradiation with nitrogen ions profoundly suppresses the integrated photoluminescence intensity that decreases by more than an order of magnitude. A correlation between the changes in the photoluminescence intensity and the amplitude of the ESR spectra on annealing of the silicon nitride films is observed.

36 MATERIALS SCIENCE↗

Total-dose radiation effects data for semiconductor devices, volume 3

Volume 3 of this three-volume set provides a detailed analysis of the data in Volumes 1 and 2, most of which was generated for the Galileo Orbiter Program in support of NASA space programs. Volume 1 includes total ionizing dose radiation test data on diodes, bipolar transistors, field effect transistors, and miscellaneous discrete solid-state devices. Volume 2 includes similar data on integrated circuits and a few large-scale integrated circuits. The data of Volumes 1 and 2 are combined in graphic format in Volume 3 to provide a comparison of radiation sensitivities of devices of a given type and different manufacturer, a comparison of multiple tests for a single data code, a comparison of multiple tests for a single lot, and a comparison of radiation sensitivities vs time (date codes). All data were generated using a steady-state 2.5-MeV electron source (Dynamitron) or a Cobalt-60 gamma ray source. The data that compose Volume 3 represent 26 different device types, 224 tests, and a total of 1040 devices. A comparison of the effects of steady-state electrons and Cobat-60 gamma rays is also presented.

Price, W. E.↗

A Photo-Realistic 3-D Mapping System for Extreme Nuclear Environments: Chornobyl

We present a novel stereoscopic mapping system for use in nuclear accident settings. First we discuss a radiation shielded sensor array desigtned to tolerate 10(sup 6)R of cumulative dose. Next we give procedures to ensure timely, accurate range estimation using trinocular stereo. Finally, we review the implementation of a system for the integration of range information into a 3-D, textured, metrically accurate surface mesh.

3-D mapping Chornobyl robot Pioneer robot Pioneer ↗

Correlated Uncertainties in Radiation Shielding Effectiveness

The space radiation environment is composed of energetic particles which can deliver harmful doses of radiation that may lead to acute radiation sickness, cancer, and even death for insufficiently shielded crew members. Spacecraft shielding must provide structural integrity and minimize the risk associated with radiation exposure. The risk of radiation exposure induced death (REID) is a measure of the risk of dying from cancer induced by radiation exposure. Uncertainties in the risk projection model, quality factor, and spectral fluence are folded into the calculation of the REID by sampling from probability distribution functions. Consequently, determining optimal shielding materials that reduce the REID in a statistically significant manner has been found to be difficult. In this work, the difference of the REID distributions for different materials is used to study the effect of composition on shielding effectiveness. It is shown that the use of correlated uncertainties allows for the determination of statistically significant differences between materials despite the large uncertainties in the quality factor. This is in contrast to previous methods where uncertainties have been generally treated as uncorrelated. It is concluded that the use of correlated quality factor uncertainties greatly reduces the uncertainty in the assessment of shielding effectiveness for the mitigation of radiation exposure.

Werneth, Charles M.↗

DirectINJECT: Dosing Systems for Concentrated Liquid Biocides

Reliable and mass-efficient techniques for biocide dosing are necessary to enable residual microbial control in spacecraft potable water systems. DirectINJECT is an approach to provide residual microbial control by injection of concentrated aqueous biocide solution (e.g., highly soluble silver salt), and associated dosing systems technology developments. This would allow for well-controlled liquid biocide injection that requires low consumable mass and is insensitive to the chemistry of the target water. With a 40 g Ag+/l solution, required dosing rates would be ~1 μl/minute during water processing (for a system similar to the ISS WPA), requiring only approximately 20 ml/crew-year of concentrate. We identified and characterized the performance of three dosing systems: pressure-driven flow through a robust micro-capillary tube, a miniature peristaltic pump, and a multi-piston pump with integrated valving. We began to address several potential system reliability concerns including prevention or segregation of gas bubbles in the concentrate reservoirs as well as long-term materials compatibility and mechanical life.

Lance Dean Delzeit↗

Martian Radiation Environment Experiment (MARIE)

Space radiation presents a very serious hazard to crews of interplanetary human missions. The two sources of this radiation are the galactic cosmic rays (GCR) and solar energetic particle (SEP) events. The GCR provides a steady source of low dose rate radiation that is primarily responsible for stochastic effects, such as cancer, and can effect the response of the central nervous system. Nuclear interactions of these components with the Martian atmosphere produces substantial flux of neutrons with high Radio Biological Effectiveness. The uncertainty in the knowledge of many fragmentation cross sections and their energy dependence required by radiation transport codes, uncertainties in the ambient radiation environment, and knowledge of the Martian atmosphere, lead to large enough uncertainties in the knowledge of calculated radiation dose in both free space (cruise phase), in Martian orbit, and on Martian surface. Direct measurements of radiation levels, the relative contributions of protons, neutrons, and heavy ions, and Martian atmospheric characteristics is thus a prerequisite for any human mission. An integrated suite of two spectrometers to provide these data will be described. The Orbiter spectrometer will measure the energy spectrum of SEP events from 15 to 500 MeV/n, and when combined with data from other space based instruments, such as the Advanced Composition Explorer (ACE), would provide accurate GCR spectra also. The Lander spectrometer would measure the absorbed dose rate, dose equivalent dose rate, and the linear energy transfer (LET) spectra and is capable of separating the relative contribution of these quantities from protons, neutrons, and high Z particles. There are two separate flight instruments, one for the Orbiter and one for the Lander, based on a common design of the backplane, the central processing unit (CPU), power supply, and onboard data storage. The Orbiter instrument consists of an energetic particle spectrometer that can measure the elemental energy spectra of charged particles over energy range of 15-500 MeV/n. The spectrometer will be mounted on the science deck and has an angular acceptance of 50 degrees. As the spacecraft orbits Mars, the axis of this field of view sweeps a cone of directions on the sky. During each orbit, the angle between the axis of the spectrometer's field of view and the mean interplanetary field direction varies from 90 degrees to 180 degrees. The Lander instrument is designed: (1) to measure the accumulated absorbed dose and dose rate in tissue as a function of time, (2) to determine the radiation quality factor, (3) to determine the energy deposition spectrum from 0.1 keV/micron to 1500 keV/micron, and (4) to separate the contribution of protons, neutrons, and HZE particles to these quantities.

Badhwar, Gautam D.↗

Total-dose radiation effects data for semiconductor devices. 1985 supplement. Volume 2, part A

Steady-state, total-dose radiation test data, are provided in graphic format for use by electronic designers and other personnel using semiconductor devices in a radiation environment. The data were generated by JPL for various NASA space programs. This volume provides data on integrated circuits. The data are presented in graphic, tabular, and/or narrative format, depending on the complexity of the integrated circuit. Most tests were done using the JPL or Boeing electron accelerator (Dynamitron) which provides a steady-state 2.5 MeV electron beam. However, some radiation exposures were made with a Cobalt-60 gamma ray source, the results of which should be regarded as only an approximate measure of the radiation damage that would be incurred by an equivalent electron dose.

Martin, K. E.↗

File format for normalizing radiological concentration exposure rate and dose rate data for the effects of radioactive decay and weathering processes

This report specifies the electronic file format that was agreed upon to be used as the file format for normalized radiological data produced by the software tool developed under this TI project. The NA-84 Technology Integration (TI) Program project (SNL17-CM-635, Normalizing Radiological Data for Analysis and Integration into Models) investigators held a teleconference on December 7, 2017 to discuss the tasks to be completed under the TI program project. During this teleconference, the TI project investigators determined that the comma-separated values (CSV) file format is the most suitable file format for the normalized radiological data that will be outputted from the normalizing tool developed under this TI project. The CSV file format was selected because it provides the requisite flexibility to manage different types of radiological data (i.e., activity concentration, exposure rate, dose rate) from other sources [e.g., Radiological Assessment and Monitoring System (RAMS), Aerial Measuring System (AMS), Monitoring and Sampling). The CSV file format also is suitable for the file format of the normalized radiological data because this normalized data can then be ingested by other software [e.g., RAMS, Visual Sampling Plan (VSP)] used by the NA-84’s Consequence Management Program.

97 MATHEMATICS AND COMPUTING↗

WE-A-12A-01: Medical Physics 1.0 to 2.0, Session 2: Radiography, Mammography and Fluoroscopy

Medical Physics 2.0 is a bold vision for an existential transition of clinical imaging physics in face of the new realities of value-based and evidencebased medicine, comparative effectiveness, and meaningful use. It speaks to how clinical imaging physics can expand beyond traditional insular models of inspection and acceptance testing, oriented toward compliance, towards team-based models of operational engagement, prospective definition and assurance of effective use, and retrospective evaluation of clinical performance. Organized into four sessions of the AAPM, this particular session focuses on three specific modalities as outlined below. Radiography 2.0: The development of electronic capture in recent years has changed the landscape and spurred reinvestment by healthcare providers. The radiography presentation will explore how the diagnostic medical physicist must adapt to these changes to support radiographic imaging, and how she/he can add value in radiography practice over the next 5-10 years. Topics of discussion include new metrology of evaluation, new models of clinical engagement, and effective integration of new technologies. Mammography 2.0: Mammography has been an interesting testing ground on the effectiveness of close involvement of medical physicists with equipment in the past twenty years. The outcomes have clearly shown major improvements in image quality and significant reduction in the average glandular dose. However, the medical physicist's role in mammography has been largely focused to annual surveys and with limited input on operational issues with image artifacts, optimal mammographic acquisition mode and problems with image quality. This mammography presentation will address why and how medical physicists must be prepared to address the new models of practice that include new metrics of performance and the integration of new technologies (DBT, syncretized mammograms, contrast mammography, breast CT) into clinical practice. Fluoroscopy 2.0: Physics support of fluoroscopy should be operationally as opposed to compliance focused. Testing protocols must address new hardware, acquisition methods, and image processing. Future available tools are discussed. Proper configuration of acquisition parameters (focal spot size, voltage and added filter, tube current, pulse width, pulse rate, scatter removal) as a function of patient size from the neonate to bariatric patient is key to providing diagnostic image quality at properly managed radiation doses. Learning Objectives: Appreciate the limitations of the currently available tools and techniques in clinical medical physics in radiography, mammography, and fluoroscopy, and ways to improve upon current deficiencies. Appreciate the changing environment of imaging practice and the need for the medical physicist to be an expert consultant and educator in a capacity that extends beyond the annual survey of equipment. Understand the status of the rapidly changing environment in breast imaging from planar imaging to tomosynthesis and possibly to breast CT. Identify appropriate configuration of acquisition parameters as a function of patient size to manage radiation dose and ensure diagnostic image quality.

60 APPLIED LIFE SCIENCES↗

TH-CD-201-07: Experimentally Investigating Proton Energy Deposition On the Microscopic Scale Using Fluorescence Nuclear Track Detectors

Purpose: In order to further understand the interplay between proton physics and radiobiology it is necessary to consider proton energy deposition on the microscopic scale. In this work we used Fluorescent Nuclear Track Detectors (FNTDs) to experimentally investigate proton energy deposition, track-by-track. Methods: We irradiated 8×4×0.5mm{sup 3} FNTD chips (Landauer Inc) at seven water depths along a pristine proton Bragg peak with range=12cm. After irradiation, the FNTDs were scanned using a confocal microscope (FV1200, Olympus) with a high-power red laser and an oil-immersion objective lens (UPLSAPO60XO, NA=1.35). 10 slice image stacks were acquired with a slice-thickness of 2µm at multiple positions across each FNTD. Image-based analyses of track radius and track “mass” (integrated signal intensity) were performed using trackpy. For comparison, Monte Carlo simulated data were obtained using TOPAS and TOPAS-nBio. Results: Excellent correlation was observed between median track mass and TOPAS dose-averaged linear energy transfer. The resolution of the imaging system was determined insufficient to detect a relationship between track radius and exposure depth. Histograms of track mass (i) displayed strong repeatability across positions within an FNTD and (ii) varied in peak position and shape as a function of depth. TOPAS-nBio simulations implemented on the nanometer scale using physics lists from GEANT4-DNA yielded energy deposition distributions for individual protons and electrons scored within a virtual FNTD. Good agreement was found between these simulated datasets and the FNTD track mass distributions. Conclusion: Robust experimental measurements of the integral energy deposited by individual proton tracks can be performed using FNTDs. Monte Carlo simulations offer an exceedingly powerful approach to the quantification of proton energy deposition on the microscopic scale, but whilst they have been well validated at the macroscopic level, their microscopic validation is far from complete. Our results demonstrate that FNTD-based study can play an important role in addressing this deficit. Tracy Underwood gratefully acknowledges the support of the European Commission under an FP7 Marie Curie International Outgoing Fellowship for Career Development (#630064).

60 APPLIED LIFE SCIENCES↗

Radiotherapy Alone With Curative Intent in Patients With Stage I Extranodal Nasal-Type NK/T-Cell Lymphoma

Purpose: This study aims to evaluate the outcome and pattern of failure in a large cohort of patients with Stage I NK/T-cell lymphoma of the upper aerodigestive tract treated with radiotherapy alone. Methods and Materials: The pathological diagnosis was confirmed using standard criteria. All patients were treated with high-dose extended-field radiotherapy alone. The median dose was 50 Gy. The primary tumor was located in the nasal cavity (n = 80), Waldeyer ring (n = 5), or oral cavity (n = 2). Results: The overall response to radiotherapy was achieved in 85 of 87 (97.7%) patients, with a complete response rate of 95.4% and a partial response rate of 2.3%. The 5-year overall survival, progression-free survival, and local control rates for all patients were 80%, 69%, and 93%, respectively. Twenty patients (23%) had disease progression or relapse. Of these, 15 patients (17%) developed systemic extranodal disseminations, whereas only 4 (5%) patients had local relapse and 4 (5%) patients had lymph node relapse. Conclusions: Our study suggests that high-dose extended-field radiotherapy alone is a curative therapy and shows favorable clinical outcome in patients with Stage I disease. With the high possibility of local control and primary failure of systemic dissemination, the integration of optimal radiotherapy with more effective systematic therapy is warranted to bring additional improvement to the outcome for these patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Characterization of the polysilicon resistor in silicon strip sensors for ATLAS inner tracker as a function of temperature, pre- and post-irradiation

The high luminosity upgrade of the Large Hadron Collider, foreseen for 2029, requires the replacement of the ATLAS Inner Detector with a new all-silicon Inner Tracker (ITk). The expected ultimate total integrated luminosity of 4000 fb –1 means that the strip part of the ITk detector will be exposed to the total particle fluences and ionizing doses reaching the values of 1.6 · 10 15 1 MeV n eq /cm 2 and 0.66 MGy, respectively, including a safety factor of 1.5. Radiation hard n + -in-p micro-strip sensors were developed by the ATLAS ITk strip collaboration and are produced by Hamamatsu Photonics K.K. The active area of each ITk strip sensor is delimited by the n-implant bias ring, which is connected to each individual n + implant strip by a polysilicon bias resistor. The total resistance of the polysilicon bias resistor should be within a specified range to keep all the strips at the same potential, prevent the signal discharge through the grounded bias ring and avoid the readout noise increase. While the polysilicon is a ubiquitous semiconductor material, the fluence and temperature dependence of its resistance is not easily predictable, especially for the tracking detector with the operational temperature significantly below the values typical for commercial microelectronics. Dependence of the resistance of polysilicon bias resistor on the temperature, as well as on the total delivered fluence and ionizing dose, was studied on the specially-designed test structures called ATLAS Testchips, both before and after their irradiation by protons, neutrons, and gammas to the maximal expected fluence and ionizing dose. The resistance has an atypical negative temperature dependence. It is different from silicon, which shows that the grain boundary has a significant contribution to the resistance. Finally, we discuss the contributions by parameterizing the activation energy of the polysilicon resistance as a function of the temperature for unirradiated and irradiated ATLAS Testchips.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

D and D projects of Tecnubel in Belgium and abroad

Safe decontamination is a regular requirement in the lifecycle of a nuclear plant and is integral to the careful maintenance of any nuclear installation for 4 key reasons: - To decrease the risk of radioactive contamination spreading; - To limit the radioactive doses contracted by maintenance personnel; - To limit the radioactive doses incurred during decommissioning; - To downgrade the class of radioactive waste The primary goal of decommissioning is to remove aged and/or contaminated and/or activated components of an installation, safely and securely, in as short a time as possible. There are several reasons why this may be necessary: - To eliminate the risk of radioactive contamination spreading; - To eliminate the risk of radiation; - To downgrade a site or a circuit to a point where it no longer is submitted to regular inspection; - To remove installations or parts that are no longer in service or have aged There are many different D and D techniques, tools and materials available today. What is important is knowing how best to use them. This paper describes the experiences and the future projects of Tecnubel in D and D projects in Belgium and abroad. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Federal Radiological Monitoring and Assessment Center (FRMAC) Assessment Manual, Volume 1: Overview and Methods

The Federal Radiological Monitoring and Assessment Center (FRMAC) Assessment Manual is the tool used to organize and guide activities of the FRMAC Assessment Division. The mission of the FRMAC Assessment Division in a radiological emergency is to interpret radiological data and predict worker and public doses. This information is used by Decision Makers to recommend protective actions in accordance with Protection Action Guides (PAGs) issued by government agencies. This manual integrates many health physics tools and techniques used to make these assessments. Volume 1 contains the scientific bases and computational methods for assessment calculations. These calculations are broken up into sections: Section 1 – Public Protection; Section 2 – Emergency Worker Protection; Section 3 – Ingestion Pathway Analysis; and, Section 4 – Supplemental Methods. FRMAC’s broad-based staff is the key to achieving Assessment's objectives. The staff is drawn from multiple agencies and has a variety of skills. The staff includes health physicists, data analysts, cartographers, modelers, meteorologists, and computer scientists. These professionals facilitate the analysis, interpretation, presentation and preservation of incident specific radiological data. These individuals are primarily drawn from the NNSA and the EPA. However, staff also includes members from the NRC, USDA, FDA, CDC, and other Federal agencies. State, Local, and Tribal scientific specialists are also invited to participate.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

FRMAC Assessment Manual Volume 1 Overview and Methods

The Federal Radiological Monitoring and Assessment Center (FRMAC) Assessment Manual is the tool used to organize and guide activities of the FRMAC Assessment Division. The mission of the FRMAC Assessment Division in a radiological emergency is to interpret radiological data and predict worker and public doses. This information is used by Decision Makers to recommend protective actions in accordance with Protection Action Guides (PAGs) issued by government agencies. This manual integrates many health physics tools and techniques used to make these assessments.

61 RADIATION PROTECTION AND DOSIMETRY↗

FRMAC Assessment Manual Volume 1 (Overview and Methods)

The Federal Radiological Monitoring and Assessment Center (FRMAC) Assessment Manual is the tool used to organize and guide activities of the FRMAC Assessment Division. The mission of the FRMAC Assessment Division in a radiological emergency is to interpret radiological data and predict worker and public doses. This information is used by Decision Makers to recommend protective actions in accordance with Protection Action Guides (PAGs) issued by government agencies. This manual integrates many health physics tools and techniques used to make these assessments.

54 ENVIRONMENTAL SCIENCES↗

Radiation-Hardness Data For Semiconductor Devices

Document presents data on and analysis of radiation hardness of various semiconductor devices. Data specifies total-dose radiation tolerance of devices. Volume 1 of report covers diodes, bipolar transistors, field effect transistors, silicon controlled rectifiers and optical devices. Volume 2 covers integrated circuits. Volume 3 provides detailed analysis of data in volumes 1 and 2.

Price, W. E.↗