Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Heat”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 883 records · Page 49

COMPARATIVE STUDY AMONG HYBRID GROUND SOURCE HEAT PUMP SYSTEM, COMPLETE GROUND SOURCE HEAT PUMP AND CONVENTIONAL HVAC SYSTEM

In this paper, a hotel with hybrid geothermal heat pump system (HyGSHP) in the Pensacola is selected and simulated by the transient simulation software package TRNSYS [1]. To verify the simulation results, the validations are conducted by using the monthly average entering water temperature, monthly facility consumption data, and etc. And three types of HVAC systems are compared based on the same building model and HVAC system capacity. The results are presented to show the advantages and disadvantages of HyGSHP compared with the other two systems in terms of energy consumptions, life cycle cost analysis.

15 GEOTHERMAL ENERGY↗

Full-scale 3-D finite element modeling of a two-loop pressurized water reactor for heat transfer, thermal–mechanical cyclic stress analysis, and environmental fatigue life estimation

This paper discusses a system-level finite element model of a two-loop pressurized water reactor (PWR). Based on this model, system-level heat transfer analysis and subsequent sequentially coupled thermal-mechanical stress analysis were performed for typical thermal-mechanical fatigue cycles. The in-air fatigue lives of example components, such as the hot and cold legs, were estimated on the basis of stress analysis results, ASME in-air fatigue life estimation criteria, and fatigue design curves. Furthermore, environmental correction factors and associated PWR environment fatigue lives for the hot and cold legs were estimated by using estimated stress and strain histories and the approach described in US-NRC report: NUREG-6909.

Full-scale 3-D finite element model, Pressurized w↗

State-by-State comparison of combined heat and power to photovoltaic installations at manufacturing facilities with heat and power loads

Manufacturing facilities with large electricity and steam loads commonly meet those loads with a grid and boiler (GB) system configuration. In this study, two alternatives, a natural gas turbine cycle driven combined heat and power (CHP) system configuration and a grid boiler system augmented with photovoltaics (GB-PV), are investigated sustainable manufacturing in reference to the GB system configuration. For this purpose, their discounted payback period (DPP), carbon dioxide (CO 2 ) and nitrogen oxides (NO x ) emission reductions, and primary fossil energy impacts are calculated. The major contribution of this study is that it directly compares the application of both CHP and PV technologies at an assumed manufacturing facility in all 50 states of the United States. This highlights the location-specific impacts of the facility. The examined manufacturing facility utility requirements are 5 MW of power and over 12,000 kg/h of 250 kPa and 400 K saturated steam. A DPP of less than 25 years, the technology lifetime, is found in 44 states for the CHP system configuration and 6 states for the GB-PV system configuration. GB-PV and CHP cost-effectively reduce CO 2 in 44 and 38 states, respectively. CHP is better for NO x reduction, whereas GB-PV is better for primary fossil energy reduction.

14 SOLAR ENERGY↗

Copper Outdiffusion from Copper-Plated Solar Cell Contacts during Damp Heat Exposure

Plated copper (Cu) contacts for silicon (Si) solar cells are an attractive alternative material to conventional screenprinted silver, but there are unresolved questions on the long-term integrity of plated contact structures. Here, in this work, we perform characterization on plated Cu contacts from encapsulated cells that were degraded during extended exposure to damp heat (DH) stress. First, using energy-dispersive X-ray spectroscopy, we find evidence of Cu outdiffusion upward through capping layers made of both tin and silver applied with light-induced plating, resulting in a layer of Cu on the outer contact surface. We hypothesize that if Cu is mobile in the module, it may eventually find some route by which to enter the Si cells where it can degrade performance. Subsequently, in several types of Cu-plated, DH-degraded cells, secondary ion mass spectrometry detects elevated levels of Cu at the Si surface and in the Si cell bulk, which suggests that Cu can indeed migrate from contacts into Si over the course of DH stress.

14 SOLAR ENERGY↗

Specific heat of Nb{sub 3}Sn: The case for a single gap

The important influence of multiple gaps in the superconductivity of MgB{sub 2} and Fe-based compounds, especially because of the possibility that manipulation of a second gap can significantly raise the upper critical field H{sub c2}, has refocused attention on Nb{sub 3}Sn because anomalies in both specific heat and point-contact tunneling studies have led to the proposal that Nb{sub 3}Sn is also a two-gap superconductor. Here, we search for evidence of the second gap in a careful study of the influence of the homogenization temperature on the sample uniformity. We show that it is very difficult to fabricate samples that are both homogeneous and stoichiometric. We find so-called “second-gap” anomalies disappear only after high temperature and long-term annealing. Such a well-annealed sample shows only a strong, electron-phonon-coupled, single-gap behavior. In contrast, samples reacted and annealed at lower temperatures, as in the earlier two-gap studies, show small chemical composition variations of the A15 phase. We propose that the second gap sightings are actually due to variation of T{sub c} within very difficult-to-fully homogenize samples. A curiosity of the A15 Nb{sub 3}Sn phase is that almost any mixture of Nb and Sn tries to form a stoichiometric A15 composition, but the residue of course contains off-stoichiometric A15, Nb, and other phases when the Nb:Sn ratio departs from the true 3:1 stoichiometry.

36 MATERIALS SCIENCE↗

Heat-driven spin transport in a ferromagnetic metal

As a non-magnetic heavy metal is attached to a ferromagnet, a vertically flowing heat-driven spin current is converted to a transverse electric voltage, which is known as the longitudinal spin Seebeck effect (SSE). If the ferromagnet is a metal, this voltage is also accompanied by voltages from two other sources, i.e., the anomalous Nernst effect in both the ferromagnet and the proximity-induced ferromagnetic boundary layer. By properly identifying and carefully separating those different effects, we find that in this pure spin current circuit the additional spin current drawn by the heavy metal generates another significant voltage by the ferromagnetic metal itself which should be present in all relevant experiments.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Improved methods for Feynman path integral calculations and their application to calculate converged vibrational–rotational partition functions, free energies, enthalpies, entropies, and heat capacities for methane

We present an improved version of our “path-by-path” enhanced same path extrapolation scheme for Feynman path integral (FPI) calculations that permits rapid convergence with discretization errors ranging from O(P{sup −6}) to O(P{sup −12}), where P is the number of path discretization points. We also present two extensions of our importance sampling and stratified sampling schemes for calculating vibrational–rotational partition functions by the FPI method. The first is the use of importance functions for dihedral angles between sets of generalized Jacobi coordinate vectors. The second is an extension of our stratification scheme to allow some strata to be defined based only on coordinate information while other strata are defined based on both the geometry and the energy of the centroid of the Feynman path. These enhanced methods are applied to calculate converged partition functions by FPI methods, and these results are compared to ones obtained earlier by vibrational configuration interaction (VCI) calculations, both calculations being for the Jordan–Gilbert potential energy surface. The earlier VCI calculations are found to agree well (within ∼1.5%) with the new benchmarks. The FPI partition functions presented here are estimated to be converged to within a 2σ statistical uncertainty of between 0.04% and 0.07% for the given potential energy surface for temperatures in the range 300–3000 K and are the most accurately converged partition functions for a given potential energy surface for any molecule with five or more atoms. We also tabulate free energies, enthalpies, entropies, and heat capacities.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Heat loads to divertor nearby components from secondary radiation evolved during plasma instabilities

A fundamental issue in tokamak operation related to power exhaust during plasma instabilities is the understanding of heat and particle transport from the core plasma into the scrape-off layer and to plasma-facing materials. During abnormal and disruptive operation in tokamaks, radiation transport processes play a critical role in divertor/edge-generated plasma dynamics and are very important in determining overall lifetimes of the divertor and nearby components. This is equivalent to or greater than the effect of the direct impact of escaped core plasma on the divertor plate. We have developed and implemented comprehensive enhanced physical and numerical models in the upgraded HEIGHTS package for simulating detailed photon and particle transport in the evolved edge plasma during various instabilities. The paper describes details of a newly developed 3D Monte Carlo radiation transport model, including optimization methods of generated plasma opacities in the full range of expected photon spectra. Response of the ITER divertor's nearby surfaces due to radiation from the divertor-developed plasma was simulated by using actual full 3D reactor design and magnetic configurations. We analyzed in detail the radiation emission spectra and compared the emission of both carbon and tungsten as divertor plate materials. The integrated 3D simulation predicted unexpectedly high damage risk to the open stainless steel legs of the dome structure in the current ITER design from the intense radiation during a disruption on the tungsten divertor plate.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Joule heating induced thermomigration failure in un-powered microbumps due to thermal crosstalk in 2.5D IC technology

Thermal-crosstalk induced thermomigration failure in un-powered microbumps has been found in 2.5D integrated circuit (IC) circuit. In 2.5D IC, a Si interposer was used between a polymer substrate and a device chip which has transistors. The interposer has no transistors. If transistors are added to the interposer chip, it becomes 3D IC. In our test structure, there are two Si chips placed horizontally on a Si interposer. The vertical connections between the interposer and the Si chips are through microbumps. We powered one daisy chain of the microbumps under one Si chip; however, the un-powered microbumps in the neighboring chip are failed with big holes in the solder layer. We find that Joule heating from the powered microbumps is transferred horizontally to the bottom of the neighboring un-powered microbumps, and creates a large temperature gradient, in the order of 1000 °C/cm, through the un-powered microbumps in the neighboring chip, so the latter failed by thermomigration. In addition, we used synchrotron radiation tomography to compare three sets of microbumps in the test structure: microbumps under electromigration, microbumps under thermomigration, and microbumps under a constant temperature thermal annealing. The results show that the microbumps under thermomigration have the largest damage. Furthermore, simulation of temperature distribution in the test structure supports the finding of thermomigration.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Kinetic corrections to heat-flow and Nernst advection for laser heated plasmas

Reduced models for approximating the impact of kinetic electron behavior on the transport of thermal energy and magnetic field are investigated. The thermal flux limiter has improved agreement with Vlasov–Fokker–Planck data when a harmonic form is used that adjusts the electron mean free path to account for electron–electron collisions; these results apply to both unmagnetized and magnetized plasmas. Once a magnetic field is incorporated, the mean free path should also be modified using the electron gyroradius. A flux limiter on Nernst advection of magnetic fields is also required; a form that limits Nernst by the same fraction as the thermal heat-flow best reproduces kinetic simulations. A flux limiter form for the cross terms (Righi–Leduc and cross-gradient-Nernst) is also suggested. Hohlraum simulations relevant to fusion experiments on the National Ignition Facility are found to be sensitive to all of these details.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Investigation of Some Transparent Metal Oxides as Damp Heat Protective Coating for CIGS Solar Cells: Preprint

We investigated the protective effectiveness of some transparent metal oxides (TMO) on CIGS solar cell coupons against damp heat (DH) exposure at 85oC and 85% relative humidity (RH). Sputter-deposited bilayer ZnO (BZO) with up to 0.5-um Al-doped ZnO (AZO) layer and 0.2-um bilayer InZnO were used as 'inherent' part of device structure on CdS/CIGS/Mo/SLG. Sputter-deposited 0.2-um ZnSnO and atomiclayer deposited (ALD) 0.1-um Al2O3 were used as overcoat on typical BZO/CdS/CIGS/Mo/SLG solar cells. The results were all negative -- all TMO-coated CIGS cells exhibited substantial degradation in DH. Combining the optical photographs, PL and EL imaging, SEM surface micro-morphology, coupled with XRD, I-V and QE measurements, the causes of the device degradations are attributed to hydrolyticcorrosion, flaking, micro-cracking, and delamination induced by the DH moisture. Mechanical stress and decrease in crystallinity (grain size effect) could be additional degrading factors for thicker AZO grown on CdS/CIGS.

14 SOLAR ENERGY↗

Orientation of heated premise in the design of insolation passive heating systems

The technique for calculating the start and end times and the direct sunlight illumination period is described. The cumulative solar radiation (SR) falling on the front surface of translucent enclosures (TE) of heated premise (HP) is found. The final design results are based on processing 4-year generalized data from the Parkent weather station.

14 SOLAR ENERGY↗

Exploring the Relationship Between Octane Sensitivity and Heat-of-Vaporization

The latent heat-of-vaporization (HoV) of blends of biofuel and hydrocarbon components into gasolines has recently experienced expanded interest because of the potential for increased HoV to increase fuel knock resistance in direct-injection (DI) engines. Several studies have been conducted, with some studies identifying an additional anti-knock benefit from HoV and others failing to arrive at the same conclusion. Consideration of these studies holistically shows that they can be grouped according to the level of fuel octane sensitivity variation within their fuel matrices. When comparing fuels of different octane sensitivity significant additional anti-knock benefits associated with HoV are sometimes observed. Studies that fix the octane sensitivity find that HoV does not produce additional anti-knock benefit. New studies were performed at ORNL and NREL to further investigate the relationship between HoV and octane sensitivity. Three fuels were formulated for the ORNL study with matched RON and octane sensitivity, but with differing HoV. Experiments with these fuels in a 1.6-liter GTDI engine showed that the fuels exhibited very similar combustion phasing under knock-limited spark advance (KLSA) conditions. Fuels having a range of RON, octane sensitivity, and HoV were tested at NREL in a single-cylinder GDI engine under conditions where octane sensitivity has little effect on knock resistance. KLSA was found to be well correlated with RON. These results reinforce the concept that HoV anti-knock effects can be viewed as a contributor to octane sensitivity. From this viewpoint, HoV effects manifest themselves as increases in octane sensitivity.

30 DIRECT ENERGY CONVERSION↗