Marine Energy to Hydrogen Analysis Project

2021 DOE HFTO Annual Merit Review and Peer Evaluation Meeting Poster covering NREL's work reviewing the current state of knowledge as related to marine renewable energy (MRE), hydrogen, and how those two technologies could be integrated for offshore and non-grid applications.

39 EE - Hydrogen and Fuel Cell Technologies (EE-3F↗

Hydrogen Component Leak Rate Quantification for System Risk and Reliability Assessment through QRA and PHM Frameworks: Preprint

The National Renewable Energy Laboratory's (NREL) Hydrogen Safety Research and Development (HSR&D) program in collaboration with the University of Maryland's Systems Risk and Reliability Analysis Laboratory (SyRRA) are working to improve reliability and reduce risk in hydrogen systems. This approach strives to use quantitative data on component leaks and failures, together with Prognosis and Health Management (PHM), and Quantitative Risk Assessment (QRA) to identify at-risk components, reduce component failures and downtime, and predict when components require maintenance. Hydrogen component failures increase facility maintenance cost, facility downtime, and reduce public acceptance of hydrogen technologies, ultimately increasing facility size and cost because of potentially overly conservative requirements. Leaks are a predominant failure mode for hydrogen components. However, uncertainties in the amount of hydrogen emitted from leaking components and the frequency of those failure events limit the understanding of the risks that they present under real-world operational conditions. NREL has deployed a test fixture, the Leak Rate Quantification Apparatus (LRQA), to quantify the mass flow rate of leaking gases from medium and high-pressure components that have failed while in service. Quantitative hydrogen leak rate data from this system could ultimately be used to better inform risk assessment and Regulation Codes and Standards (RCS). Parallel activity explores the use of PHM and QRA techniques to assess and reduce risk, thereby improving safety and reliability of hydrogen systems. The results of QRAs could further provide a systematic and science-based foundation for the design and implementation of RCS, as in the latest versions of the NFPA 2 code for gaseous hydrogen stations. Alternatively, data-driven techniques of PHM could provide new damage diagnosis and health-state prognosis tools. This research will help end users, station owners and operators, and regulatory bodies move towards risk-informed preventative maintenance versus emergency corrective maintenance, reducing cost and improving reliability. Predictive modelling of failures could improve safety and affect RCS requirements such as setback distances at liquid refuelling sites. The combination of leak rate quantification research, PHM, and QRA can lead to better informed models enabling data-based decision to be made for hydrogen system safety improvements.

codes and standards↗

Component Reliability R&D

A review of the work done on the hydrogen Component Reliability R&D project in the last year. The National Renewable Energy Laboratory's (NREL) Hydrogen Safety Research and Development (HSR&D) program in collaboration with the University of Maryland's Systems Risk and Reliability Analysis Laboratory (SyRRA) are working to improve reliability and reduce risk in hydrogen systems through the use of use quantitative data on component leaks and failures, together with Prognosis and Health Management (PHM), and Quantitative Risk Assessment (QRA).

component↗

Safety Compliance Verification of Fuel Cell Electric Vehicle Exhaust

NREL has been developing compliance verification tools for allowable hydrogen levels prescribed by the Global Technical Regulation Number 13 (GTR-13) for hydrogen fuel cell electric vehicles (FCEVs). As per GTR-13, FCEV exhaust is to remain below 4 vol% H2 over a 3-second moving average and shall not at any time exceed 8 vol% H2 and that this requirement is to be verified with an analyzer that has a response time of less than 300 ms. To be enforceable, a means to verify regulatory requirements must exist. In response to this need, NREL developed a prototype analyzer that meets the GTR metrological requirements for FCEV exhaust analysis. The analyzer was tested on a commercial fuel cell electric vehicle (FCEV) under simulated driving conditions using a chassis dynamometer at the Emissions Research and Measurement Section of Environment and Climate Change Canada and FCEV exhaust was successfully profiled. Although the prototype FCEV Exhaust Analyzer met the metrological requirements of GTR-13, the stability of the hydrogen sensor was adversely impacted by condensed water in the sample gas. FCEV exhaust is at an elevated temperature and nearly saturated with water vapor. Furthermore, condensed water is present in the form of droplets. Condensed water in the sample gas can collect on the hydrogen sensing element, which would not only block access of hydrogen to the sensor but can also permanently damage the sensor. In the past year, the design of the gas sampling system was modified to mitigate against the transport of liquid water to the sensing element. Laboratory testing confirmed the effectiveness of the modified sampling system water removal strategy while maintaining the measurement range and response time required by GTR-13. Testing of the upgraded analyzer design on an FCEV operating on a chassis dynamometer is scheduled for the summer of 2021.

DIRECT ENERGY CONVERSION,HYDROGEN↗

The NREL Sensor Laboratory: Status and Future Directions for Hydrogen Detection

The NREL Hydrogen Sensor Laboratory was commissioned in 2010 as a resource for the national and international hydrogen community to ensure the availability and proper use of hydrogen sensors. Since then, the Sensor Laboratory has provided unbiased verification of hydrogen sensor performance for sensor developers, end-users, and regulatory agencies and has also provided active support for numerous code and standards development organizations. Although sensor performance assessment remains a core capability, the mission of the NREL Sensor Laboratory has expanded toward a more holistic approach regarding the role of hydrogen detection and its implementation strategy for both assurance of facility safety as well as for process control applications. Active monitoring for detection of unintended releases has been identified by the NFPA 2 Storage Task Group as a viable approach for improving facility safety and lowering setbacks. The current research program for the Sensor Laboratory addresses both conventional and advanced developing detection strategies in response to the emerging large-scale markets, such as those envisioned by H2@Scale. These emerging hydrogen applications may require alternative detection strategies that supplement and may ultimately supplant the use of traditional sensors for monitoring hydrogen releases. Research focus areas for the NREL Sensor Laboratory now encompasses the characterization of released hydrogen behavior to optimize detection strategies for both indoor and outdoor applications, advanced methods of hydrogen leak detection such as hydrogen wide area monitoring approaches for large scale and distributed applications, the incorporation of active monitoring as a risk reduction strategy to improve safety at hydrogen facilities, and continuing support of hydrogen safety codes and standards. In addition to assurance of safety, detection will be critical for process control applications, such as hydrogen fuel quality verification for fuel cell vehicle applications and for monitoring and controlling of hydrogen-natural gas blend composition.

codes and standards↗

NREL Hydrogen Sensor Testing Laboratory

The NREL Sensor Laboratory supports the HFTO's mission for the safe and efficient implementation of hydrogen as an energy carrier. Sensors are a critical element for a facility safety system by providing an early indication of unintended releases. Sensors can be used in process control applications (e.g., FQ verification). The Sensor Laboratory provides developers and end-users with an unbiased resource to validate sensor performance to application requirements. The Sensor Laboratory facilitates deployment through support of codes and standards development and safety research. The Sensor Laboratory supports advanced strategies for early leak detection.

detection↗

Hydrogen Contaminant Detector

This presentation describes fiscal year 2022 status and accomplishments for NREL's Hydrogen Contaminant Detector project.

analyzer↗

Component Reliability

An overview of the National Renewable Energy Laboratories Component Reliability Project including the accomplishments for the previous year.

component reliability↗

Megawatt-Scale Low Temperature Electrolyzer Research Expansion

The development and installation of a flexible low-temperature electrolyzer research capability at the multi-MW scale with integrated renewables will help lower the cost barrier to entry for electrolyzer manufactures needing at scale system and stack evaluation and enable more electrolyzer manufactures to accelerate to commercialization with building block scale demonstration and validation. This NREL capability represents a DOE HFTO investment to support the $1B DOE Clean Hydrogen Electrolysis Program working to achieve the Hydrogen Shot goal of $1 for 1 kg hydrogen in 1 decade, lower greenhouse gas emissions and criteria pollutants, build clean energy infrastructure, and provide pathways to private sector uptake.

Advanced Research on Integrated Energy Systems (AR↗

Copolymers containing pendant ionomeric carbosilane groups

Cationic polymers are provided that comprise monomeric units of Formula (V). (V) Each asterisk (*) indicates an attachment position to another monomeric unit; R is hydrogen or methyl; each R 2 is each independently an alkyl, aryl, or a combination thereof; L is a linking group comprising an alkylene group; and +R 3</sup? is a cationic nitrogen-containing group free of any N—H bonds. Membranes formed from said cationic polymers, devices including such membranes, and methods of making such cationic polymers are also provided.

Hartmann-Thompson, Claire↗

Megawatt-Scale Low Temperature Electrolyzer Research Capability

The development and installation of a flexible low-temperature electrolyzer research capability at the multi-MW scale with integrated renewables will help lower the cost barrier to entry for electrolyzer manufactures needing at scale system and stack evaluation and enable more electrolyzer manufactures to accelerate to commercialization with building block scale demonstration and validation. This NREL capability represents a DOE HFTO investment to support the $1B DOE Clean Hydrogen Electrolysis Program working to achieve the Hydrogen Shot goal of $1 for 1 kg hydrogen in 1 decade, lower greenhouse gas emissions and criteria pollutants, build clean energy infrastructure, and provide pathways to private sector uptake.

electrical grid↗

Component Failure R&D

This presentation is to establish a scientific basis for risk and reliability analysis through integrated work with data collection, model development, and stakeholder engagement.

availability↗

The NREL Sensor Laboratory: Hydrogen Leak Detection for Large Scale Deployments: Preprint

The NREL Hydrogen Sensor Laboratory was commissioned in 2010 as a resource for sensor developers, end-users, and regulatory agencies within the national and international hydrogen community. The Laboratory continues to provide as its core capability the unbiased verification of hydrogen sensor performance to assure sensor availability and their proper use. However, the mission and strategy of the NREL Sensor Laboratory has evolved to meet the needs of the growing hydrogen market. The Sensor Laboratory program has expanded to support research in conventional and alternative detection methods as hydrogen use expands to large-scale markets as envisioned by the DOE National Clean Hydrogen Strategy and Roadmap. Current research encompasses advanced methods of hydrogen leak detection including stand-off and wide area monitoring approaches for large scale and distributed applications. In addition to safety applications, low-level detection strategies to support the potential environmental impacts of hydrogen and hydrogen product losses along the value chain are being explored. Many of these applications utilize detection strategies that supplement and may supplant the use of traditional point sensors. The latest results of the hydrogen detection strategy research at NREL will be presented.

detection↗

Towards Unlocking Insights from Logbooks Using AI

Electronic logbooks contain valuable information about activities and events concerning their associated particle accelerator facilities. However, the highly technical nature of logbook entries can hinder their usability and automation. As natural language processing (NLP) continues advancing, it offers opportunities to address various challenges that logbooks present. This work explores jointly testing a tailored Retrieval Augmented Generation (RAG) model for enhancing the usability of particle accelerator logbooks at institutes like DESY, BESSY, Fermilab, BNL, SLAC, LBNL, and CERN. The RAG model uses a corpus built on logbook contributions and aims to unlock insights from these logbooks by leveraging retrieval over facility datasets, including discussion about potential multimodal sources. Our goals are to increase the FAIR-ness (findability, accessibility, interoperability, and reusability) of logbooks by exploiting their information content to streamline everyday use, enable macro-analysis for root cause analysis, and facilitate problem-solving automation.

43 PARTICLE ACCELERATORS↗

Hydrogen Component Reliability Database (HyCReD)

The Hydrogen Component Reliability Database (HyCReD) is a collaborative project between the National Renewable Energy Laboratory, the University of Maryland, and hydrogen stakeholders to improve safety reliability for hydrogen facilities by integrating risk reduction methodologies and component reliability data taxonomies that support hydrogen infrastructure failure rate analysis.

availability↗

Hydrogen Detection Strategies to Support H2@SCALE - The NREL Sensor Laboratory

Hydrogen represents a major pathway to decarbonize and stabilize the national and international energy industry and select manufacturing markets. To facilitate the development of hydrogen markets, the US Department of Energy initiated H2@Scale to bring together stakeholders to advance affordable hydrogen production, transport, storage, and utilization to increase revenue opportunities in multiple energy sectors. One major impediment to hydrogen implementation is cost. To expedite the use of hydrogen in energy and other markets, the United States announced in 2021 the Hydrogen Shot, which seeks to reduce the cost of clean hydrogen by 80% to $1 per 1 kilogram in 1 decade ("1 1 1"). As the cost of hydrogen drops, new applications will emerge that will require unique configurations of existing equipment and infrastructure, and eventually lead to advances in the generation and utilization of hydrogen. As the hydrogen economy expands, sensors and detection methods will need to adapt to changing infrastructure demands to address the primary targets of health & safety, emissions monitoring, and process control. The NREL Sensor Laboratory is playing a pivotal role in advancing the use of hydrogen sensors and detection methodologies in each of these categories to support DOE's mission for safe and efficient utilization in emerging markets. Health & safety monitors are required to ensure that operators and facilities can react to unintended hydrogen releases, either as GH2, LH2, or as a constituent of blends (e.g., natural gas or ammonia). Current detection methodologies focus on safety applications to detect near its lower flammable limit (4 vol %), and typically include point sensors in applications such as fixed or mobile detectors (e.g., personal gas monitors). Methodologies amenable for area detection include acoustic, emerging optical imaging methods, and flame detectors. Comparable detection strategies can be utilized for emissions monitoring and quantization, however few methods can simultaneously cover both low (emissions) and high (health & safety) levels. Deployment of emission level detectors will be required to 1) reduce product loss through small but potentially significant leaks from an environmental or cost perspective, 2) reduce downtime of high demand systems by early identification of eminent system failures (leaks through pump or compressor seals indicative of impending failure), and 3) address potential emission monitoring requirements that may be set by regulating bodies. The first two points should be adopted by industry to reduce the cost-of-goods-sold. The third main category for hydrogen detection relates to process control and may be advantageous for many existing applications. Two main applications are emerging. For example, the purity requirements for hydrogen that is dispensed from refueling systems for hydrogen fuel cell electric vehicles (FCEV) is rigorously regulated by the Standard SAE J2719, which prescribes maximum allowable levels of multiple impurities in the hydrogen fuel and must be verified by a regulatory body. Hydrogen contaminant detectors (HCD) integrated to the fueling station can assure this compliance. HCDs must be able operate in 100% H2 backgrounds and be able to distinguish between multiple contaminants at low ppm to low ppb levels. Secondly, as a strategy to decarbonize the natural gas grid, there are proposals to blend hydrogen with natural gas. This blending will affect transport applications (pipeline infrastructure), stationary combustion systems (turbines), and consumer and commercial appliances. In the short-term, hydrogen levels up to 20% are proposed. Variations in the hydrogen level can have dramatic impact on the combustion process and on the potential response of safety sensors. These mixtures may be regulated so that the concentration at a delivery point must be monitored with high precision. However, routine maintenance may introduce background gases such as ambient air (with water) or maintenance gases (introduced with welding processes or adhesive outgassing.) Therefore, the detection methodology must be robust enough to recover or respond to various contaminants. Several reviews can be found in literature addressing sensing and detection technologies, including their limitations and applications. However, for most applications, limitations can be alleviated by combining various detection techniques either through system integration or implementation of machine learning methods (artificial intelligence). In this presentation, we will discuss several applications, highlight their current approach for hydrogen detection, and suggest detection strategies to supplement their limitations.