Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Gravity currents”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 883 records · Page 49

The development of two new KC-135 furnaces for studies on microgravity materials processing

Wyle Laboratories is currently designing and fabricating two KC-135 materials processing furnaces for Marshall Space Flight Center. The first of these, called the Rapid Melt/Rapid Quench (RM/RQ) Furnace, will be used to melt and resolidify Cu-, Al-, and Ni-based alloys and composites, all during the 20 to 30 seconds of low gravity (0.1 to 0.001 g) available in a single parabola of the KC-135. In addition, it will be capable of directional solidification of these alloys. The furnace can be configured for either liquid or gas quenching of the samples. The second furnace, called the Polymer Solidification Transparent (PST) Furnace, will use a wide range of sample translation rates to directionally solidify polymers and low-melting-point metals as the KC-135 flies a series of parabolic maneuvers. The use of transparent crucibles and an optics system between the hot and cold zones of the furnace will allow for high-resolution video monitoring of the solid-liquid interface during processing. It is hoped that the development of these two furnaces will lead to significant increases in understanding of interface kinetics, fluid flow, and heat transfer in materials during solidification in a low-gravity environment.

Fiske, Michael↗

Lunar placement of Mars quarantine facility

Advanced mission scenarios are currently being contemplated that would call for the retrieval of surface samples from Mars, from a comet, and from other places in the solar system. An important consideration for all of these sample return missions is quarantine. Quarantine facilities on the Moon offer unique advantages over other locations. The Moon offers gravity, distance, and vacuum. It is sufficiently near the Earth to allow rapid resupply and easy communication. It is sufficiently distant to lessen the psychological impact of a quarantine facility on Earth's human inhabitants. Finally, the Moon is airless, and seems to be devoid of life. It is, therefore, more suited to contamination control efforts.

Davidson, James E.↗

Mathematical modeling of acute and chronic cardiovascular changes during Extended Duration Orbiter (EDO) flights

The purpose of NASA's Extended Duration Orbiter program is a gradual extension of the capabilities of the Space Shuttle Orbiter beyond its current 7-10 day limit on mission duration, as warranted by deepening understanding of the long-term physiological effects of weightlessness. Attention is being given to the cardiovascular problem of orthostatic tolerance loss due to its adverse effects on crew performance and health during reentry and initial readaptation to earth gravity. An account is given of the results of the application of proven mathematical models of circulatory and cardiovascular systems under microgravity conditions.

White, Ronald J.↗

Modeling and new equipment definition for the vibration isolation box equipment system

Our MSAD-funded research project is to provide numerical modeling support for the VIBES (Vibration Isolation Box Experiment System) which is an IML2 flight experiment being built by the Japanese research team of Dr. H. Azuma of the Japanese National Aerospace Laboratory. During this reporting period, the following have been accomplished: A semi-consistent mass finite element projection algorithm for 2D and 3D Boussinesq flows has been implemented on Sun, HP And Cray Platforms. The algorithm has better phase speed accuracy than similar finite difference or lumped mass finite element algorithms, an attribute which is essential for addressing realistic g-jitter effects as well as convectively-dominated transient systems. The projection algorithm has been benchmarked against solutions generated via the commercial code FIDAP. The algorithm appears to be accurate as well as computationally efficient. Optimization and potential parallelization studies are underway. Our implementation to date has focused on execution of the basic algorithm with at most a concern for vectorization. The initial time-varying gravity Boussinesq flow simulation is being set up. The mesh is being designed and the input file is being generated. Some preliminary 'small mesh' cases will be attempted on our HP9000/735 while our request to MSAD for supercomputing resources is being addressed. The Japanese research team for VIBES was visited, the current set up and status of the physical experiment was obtained and ongoing E-Mail communication link was established.

Sani, Robert L.↗

Exercise and osteoporosis: Methodological and practical considerations

Physical activity may have important implications for enhancing bone density prior to the initiation of space flight, for preserving bone density during zero gravity, and for rehabilitating the skeleton upon return to Earth. Nevertheless, the beneficial effects of exercise upon the skeleton have not been proven by controlled trials and no consensus exists regarding the type, duration, and intensity of exercise necessary to make significant alterations to the skeleton. The following sections review our current understanding of exercise and osteoporosis, examine some of the methodological shortcomings of these investigations, and make research recommendations for future clinical trials.

Block, Jon E.↗

Tribological Properties of a Pennzane(Registered Trademark)-Based Liquid Lubricant (Disubstituted Alkylated Cyclopentane) for Low Temperature Space Applications

The tribological properties of a disubstituted alkylated cyclopentane, Pennzane (registered) Synthesized Hydrocarbon Fluid X-1000, are presented. This compound is a lower molecular weight version of the commonly used multiply alkylated cyclopentane, Pennzane X-2000, currently used in many space mechanisms. New, lower temperature applications will require liquid lubricants with lower viscosities and pour points and acceptable vapor pressures. Properties reported include: friction and wear studies and lubricated lifetime in vacuum; additionally, typical physical properties (i.e., viscosity-temperature, pour point, flash and fire point, specific gravity, refractive index, thermal properties, volatility and vapor pressure) are reported.

Venier, Clifford↗

Ceratopteris richardii: a productive model for revealing secrets of signaling and development

Ceratopteris richardii is an aquatic fern grown in tropical and subtropical regions of the world. It is proven to be a productive model system for studies in the genetics, biochemistry, and cell biology of basic biologic processes that occur in early gametophytic development. It provides several advantages to biologists, especially those interested in gravitational biology, polarity development, and in the genetics of sexual development. It is easy to culture, has a relatively short life cycle, and offers an array of attractive features that facilitate genetic studies. The germination and early development of large populations of genetically identical spores are easy to synchronize, and both the direction of polarity development and cell-level gravity responses can be measured and readily manipulated within the first 24 h of spore development. Although there is no reliable transformation system available yet in Ceratopteris, recent studies suggest that the technique of RNA interference can be used to block translation of specific genes in a related fern, Marsilea, and current studies will soon reveal the applicability of this approach, as well as of other transformation approaches, in Ceratopteris. A recently completed expressed sequence tag (EST) sequencing project makes available the partial sequence of more than 2000 cDNAs, representing a significant percentage of the genes being expressed during the first 24 h of spore germination, when many developmentally interesting processes are occurring. A microarray of these ESTs is being constructed, so especially for those scientists interested in basic cellular phenomena that occur early in spore germination, the availability of the ESTs and of the microarray will make Ceratopteris an even more attractive model system.

NASA Discipline Plant Biology↗

High Performance Mars Liquid Cooling and Ventilation Garment Project

EVA space suit mobility in micro-gravity is enough of a challenge and in the gravity of Mars, improvements in mobility will enable the suited crew member to efficiently complete EVA objectives. The idea proposed is to improve thermal efficiencies of the liquid cooling and ventilation garment (LCVG) in the torso area in order to free up the arms and legs by removing the liquid tubes currently used in the ISS EVA suit in the limbs. By using shaped water tubes that greatly increase the contact area with the skin in the torso region of the body, the heat transfer efficiency can be increased to provide the entire liquid cooling requirement and increase mobility by freeing up the arms and legs. Additional potential benefits of this approach include reduced LCVG mass, enhanced evaporation cooling, increased comfort during Mars EVA tasks, and easing of the overly dry condition in the helmet associated with the Advanced Extravehicular Mobility Unit (EMU) ventilation loop currently under development.

Terrier, Douglas↗

Spectral Mass Gauging of Unsettled Liquid with Acoustic Waves

Propellant mass gauging is one of the key technologies required to enable the next step in NASA's space exploration program. At present, there is no reliable method to accurately measure the amount of unsettled liquid propellant of an unknown configuration in a propellant tank in micro- or zero gravity. We propose a new approach to use sound waves to probe the resonance frequencies of the two-phase liquid-gas mixture and take advantage of the mathematical properties of the high frequency spectral asymptotics to determine the volume fraction of the tank filled with liquid. We report the current progress in exploring the feasibility of this approach, both experimental and theoretical. Excitation and detection procedures using solenoids for excitation and both hydrophones and accelerometers for detection have been developed. A 3% uncertainty for mass-gauging was demonstrated for a 200-liter tank partially filled with water for various unsettled configurations, such as tilts and artificial ullages. A new theoretical formula for the counting function associated with axially symmetric modes was derived. Scaling analysis of the approach has been performed to predict an adequate performance for in-space applications.

Feller, Jeffrey↗

CDC Bioreactor Configuration Method for Volume Level Control with Controlled Inlet and Outlet Flow

Environmental Control Life Support Systems and other microbiological biofilm studies often utilize small scale bioreactors. Among these options are the popular BioSurface CDC bioreactors, currently being utilized by Marshall Space Flight Center groups researching the impact of biofilms on life support systems. After a recent experimental regime, it was determined additional equipment could be added to augment the capabilities of the bioreactors. Previous research configurations such as ASTM E3161 – 18 relied on an outlet stream gravity draining from a side drain port located above sampling coupons. This limited applications to experimental conditions with a controlled inlet and uncontrolled outlet flow. With the introduction of a small single pole single throw (SPST) reed float switch, a peristaltic pump connected to the outlet drain and a chassis controller, the bioreactor is able to maintain a set level. The modification allows additional variables to be tested, including highly adjustable fill and flush cycles, bioreactor volume, draining and filling control. Once the configuration modifications were implemented through the installation of the new equipment, data was collected to ensure the stability of the level measurements. As the level control switch is a float switch, consideration was taken into account for effects of internal stirring speed, along with effects of inlet and outlet flow rate. Data presented in this study will illustrate the stability and effectiveness of the configuration changes in equipment made to the bioreactor. These configuration changes are proving an effective control method to conduct biofilm mitigation techniques for ECLSS hardware research. The controlled level capabilities allow for a constant drip feed flow rate into the bioreactors, a key aspect of the biofilm mitigation testing.

CDC Bioreactor↗

CDC Bioreactor Configuration Method for Volume Level Control with Controlled Inlet and Outlet Flow

Environmental Control Life Support Systems and other microbiological biofilm studies often utilize small scale bioreactors. Among these options are the popular BioSurface CDC bioreactors, currently being utilized by Marshall Space Flight Center groups researching the impact of biofilms on life support systems. After a recent experimental regime, it was determined additional equipment could be added to augment the capabilities of the bioreactors. Previous research configurations such as ASTM E3161-21 relied on an outlet stream gravity draining from a side drain port located above sampling coupons. This limited applications to experimental conditions with a controlled inlet and uncontrolled outlet flow. With the introduction of a small single pole single throw (SPST) reed float switch and a peristaltic pump connected to the outlet drain and a chassis controller, the bioreactor is able to maintain a set level. The modification allows additional variables to be tested, including highly adjustable fill and flush cycles, bioreactor volume, draining and filling control. Once the configuration modifications were implemented through the installation of the new equipment, data was collected to ensure the stability of the level measurements. As the level control switch is a float switch, consideration was taken into account for effects of internal stirring speed, along with effects of inlet and outlet flow rate. Data presented in this study will illustrate the stability and effectiveness of the configuration changes in equipment made to the bioreactor. These configuration changes have demonstrated control method to conduct biofilm mitigation techniques for ECLSS hardware research. The controlled level capabilities allow for a constant drip feed flow rate into the bioreactors, a key aspect of the biofilm mitigation testing.

CDC Bioreactor↗

Development of a Loop Antenna Deployment System for TEM-Based Subsurface Mars Water Detection

The subsurface of Mars has the potential to harbor existing deposits of liquid water, which are of great interest both scientifically (in the search for life) and as resources for future astronauts living on the red planet. However, the depth to a potential subsurface aquifer may be kilometers deep, which is well beyond what current surface or orbital approaches can survey while also confirming the unique signature for liquid water. Inspired by critical technology for exploring deep aquifers on Earth, we are developing the Transient H2O Reconnaissance (TH2OR) instrument at NASA’s Jet Propulsion Laboratory (JPL). TH2OR operates on the principle of transient electromagnetics (TEM), which leverages induction and electromotive force to induce a current in a subsurface water body using a loop-shaped antenna that provides both transmit and receive functions when placed on the surface. On Mars, TEM may be even more effective given the relative dryness of the subsurface compared to a more conductive, saline, liquid, water body on Earth. However, to probe deep within the subsurface (below 5 km) a large enclosed antenna is needed – specifically, a 100-m diameter effective loop or a shape with roughly equivalent area that can transmit at low frequencies (kHz-Hz). The deployment of a large-scale structure on the surface is complicated by the fact that the transmit wire must be both lightweight and robust to contact with the surface. Further, TH2OR may be delivered to the surface by a non-mobile vehicle, so it is desired that the deployment can be activated from a static location. This paper provides an overview of the deployment trade study, focusing on our current, favored approach, using a projectile wire launcher. Building on past approaches in the literature, we have developed and fielded an Earth-based, gas-projectile prototype for launching a triangle-shaped antenna onto analogue terrain. Our results compare simulated launch performance to actual field tests conducted under Earth gravity and pressure conditions. We discuss how Earth performance maps to a prospective Mars deployment under reduced gravity and pressure. We also provide lessons learned and next steps towards the development of an integrated TH2OR instrument for finding water on Mars.

Stamenkovic, Vlada↗

CDC Bioreactor Configuration Method for Volume Level Control with Controlled Inlet and Outlet Flow

Environmental Control Life Support Systems and other microbiological biofilm studies often utilize small scale bioreactors. Among these options are the popular BioSurface CDC bioreactors, currently being utilized by Marshall Space Flight Center groups researching the impact of biofilms on life support systems. After a recent experimental regime, it was determined additional equipment could be added to augment the capabilities of the bioreactors. Previous research configurations such as ASTM E3161-21 relied on an outlet stream gravity draining from a side drain port located above sampling coupons. This limited applications to experimental conditions with a controlled inlet and uncontrolled outlet flow. With the introduction of a small single pole single throw (SPST) reed float switch and a peristaltic pump connected to the outlet drain and a chassis controller, the bioreactor is able to maintain a set level. The modification allows additional variables to be tested, including highly adjustable fill and flush cycles, bioreactor volume, draining and filling control. Once the configuration modifications were implemented through the installation of the new equipment, data was collected to ensure the stability of the level measurements. As the level control switch is a float switch, consideration was taken into account for effects of internal stirring speed, along with effects of inlet and outlet flow rate. Data presented in this study will illustrate the stability and effectiveness of the configuration changes in equipment made to the bioreactor. These configuration changes have demonstrated control method to conduct biofilm mitigation techniques for ECLSS hardware research. The controlled level capabilities allow for a constant drip feed flow rate into the bioreactors, a key aspect of the biofilm mitigation testing.

CDC Bioreactor↗

CDC Bioreactor Configuration Method for Volume Level Control with Controlled Inlet and Outlet Flow

Environmental Control Life Support Systems and other microbiological biofilm studies often utilize small scale bioreactors. Among these options are the popular BioSurface CDC bioreactors, currently being utilized by Marshall Space Flight Center groups researching the impact of biofilms on life support systems. After a recent experimental regime, it was determined additional equipment could be added to augment the capabilities of the bioreactors. Previous research configurations such as ASTM E3161-21 relied on an outlet stream gravity draining from a side drain port located above sampling coupons. This limited applications to experimental conditions with a controlled inlet and uncontrolled outlet flow. With the introduction of a small single pole single throw (SPST) reed float switch and a peristaltic pump connected to the outlet drain and a chassis controller, the bioreactor is able to maintain a set level. The modification allows additional variables to be tested, including highly adjustable fill and flush cycles, bioreactor volume, draining and filling control. Once the configuration modifications were implemented through the installation of the new equipment, data was collected to ensure the stability of the level measurements. As the level control switch is a float switch, consideration was taken into account for effects of internal stirring speed, along with effects of inlet and outlet flow rate. Data presented in this study will illustrate the stability and effectiveness of the configuration changes in equipment made to the bioreactor. These configuration changes have demonstrated control method to conduct biofilm mitigation techniques for ECLSS hardware research. The controlled level capabilities allow for a constant drip feed flow rate into the bioreactors, a key aspect of the biofilm mitigation testing.

CDC Bioreactor↗

Jupiter: Atmospheric Sounding and Sensing of the Interior (JASSI)

The formation of the giant planets is one of the most fundamental questions in solar system exploration. Understanding the process that led to the creation of Jupiter is essential to understanding the nature of the primordial solar nebula, and the formation of our solar system and others currently being discovered. Data from Galileo combined with HST and Ulysses results validated our basic understanding of Jupiter as a giant planet whose gaseous envelope consists of solar nebula gas enriched in elements heavier than He by in falling icy planetesimals. However, the current Galileo Probe data set does not itself allow firm conclusions about the original planetesimal composition or the process of giant planet formation - we crucially need the O and N abundances that Galileo could not determine. We propose a new and simple concept capable of determining these abundance in Jupiter plus substantial gravity science. Additional information is contained in the original extended abstract.

Bolton, S. J.↗

Validation of Mean Absolute Sea Level of the North Atlantic obtained from Drifter, Altimetry and Wind Data

Mean absolute sea level reflects the deviation of the Ocean surface from geoid due to the ocean currents and is an important characteristic of the dynamical state of the ocean. Values of its spatial variations (order of 1 m) are generally much smaller than deviations of the geoid shape from ellipsoid (order of 100 m) that makes the derivation of the absolute mean sea level a difficult task for gravity and satellite altimetry observations. Technique used by Niiler et al. for computation of the absolute mean sea level in the Kuroshio Extension was then developed into more general method and applied by Niiler et al. (2003b) to the global Ocean. The method is based on the consideration of balance of horizontal momentum.

Maximenko, Nikolai A.↗

An Ultrasonic Sampler and Sensor Platform for In-Situ Astrobiological Exploration

The search for existing or past life in the Universe is one of the most important objectives of NASA's mission. In support of this objective, ultrasonic based mechanisms are currently being developed at JPL to allow probing and sampling rocks as well as perform as a sensor platform for in-situ astrobiological analysis. The technology is based on the novel Ultrasonic/Sonic Driller/Corer (USDC), which requires low axial force, thereby overcoming one of the major limitations of planetary sampling in low gravity using conventional drills. The USDC was demonstrated to: 1) drill ice and various rocks including granite, diorite, basalt and limestone, 2) not require bit sharpening, and 3) operate at high and low temperatures. The capabilities that are being investigated including probing the ground to select sampling sites, collecting various forms of samples, and hosting sensors for measuring chemical/physical properties. A series of modifications of the USDC basic configuration were implemented leading an ultrasonic abrasion tool (URAT), Ultrasonic Gopher for deep Drilling, and the lab-on-a-drill.

robotics↗

Soil maturity and planetary regoliths - The Moon, Mercury, and the asteroids

Observations of the Moon, Mercury and the asteroids provide data which can be used to assess current ideas about the optical maturation of regoliths of bodies without atmospheres. Telescopic data show Mercury's surface to be as optically mature as the Moon's while the asteroids appear to have 'fresh' surfaces. We suggest that these cases illustrate two different paths of regolith evolution caused by differing micrometeoroid impact velocities, gravity, and in some cases composition.

Matson, D. L.↗