Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “GAMMA RADIATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 883 records · Page 49

Investigation of the internal electric field in cadmium zinc telluride detectors using the Pockels effect and the analysis of charge transients

The Pockels electro-optic effect can be used to investigate the internal electric field in cadmium zinc telluride (CZT) single crystals that are used to fabricate room temperature x and gamma radiation detectors. An agreement is found between the electric field mapping obtained from Pockels effect images and the measurements of charge transients generated by alpha particles. The Pockels effect images of a CZT detector along two mutually perpendicular directions are used to optimize the detector response in a dual anode configuration, a device in which the symmetry of the internal electric field with respect to the anode strips is of critical importance. The Pockels effect is also used to map the electric field in a CZT detector with dual anodes and an attempt is made to find a correlation with the simulated electric potential in such detectors. Finally, the stress-induced birefringence effects seen in the Pockels images are presented and discussed.

36 MATERIALS SCIENCE↗

GRO: Studies of High Energy Pulsars with EGRET

The Energetic Gamma-Ray Experiment Telescope (EGRET) on the Compton Gamma Ray Observatory has observed PSR B1706-44 a number of times between 1991 and 1995. From these data, a more detailed picture of the gamma radiation from this source has been developed, showing several characteristics that distinguish this pulsar from others: the light curve is complex, with evidence of three pulses; there is no detectable unpulsed emission; and the energy spectrum changes slope at 1 GeV. No two of the known gamma-ray pulsars have quite the same characteristics; this diversity makes interpretation in terms of theoretical models difficult.

Ruderman, Malvin↗

SU-E-T-94: An Advanced Rotating Gamma Ray System for Stereotactic Radiosurgery

Purpose: Co-60 beams have unique dosimetric properties that are ideally suited for cranial treatments. Co-60 sources with cone-shaped collimators provide conformal dose distributions allowing for ablative treatments with rapid dose falloff to spare nearby critical structures. This work investigates a novel, image-guided, rotational Gamma ray system that provides both superior dose conformity/gradient and accurate stereotaxy for stereotactic radiosurgery (SRS). Methods: The SupeRay system (Cyber Medical Corp., China) consists of a rotating source chamber containing 30 gamma sources focusing at the isocenter with 4 collimators measuring 3, 4, 8 and 16mm in diameter. A novel switch design enables the 30 Gamma sources to be turned off at any arbitrarily selected 60° interval in order to avoid critical structures. The 3D treatment couch provides automatic treatment positioning between individual shots and the kV imaging system provides orthogonal images with a spatial resolution of 0.24mm to facilitate target localization. Monte Carlo simulations were used to compute dose distributions and compare with measurements and other Gamma ray SRS systems. Results: Monte Carlo results confirmed the SupeRay design parameters including output factors and 3D dose distributions. Its beam penumbra/dose gradient is similar to or slightly better than that of the Elekta Gamma Knife. The penumbra in the (x,y,z) direction was (7.38mm,7.38mm,3.86mm) for the 16mm collimator, (4.83mm,4.83mm,3.12mm) for the 8mm collimator, and (3.03mm,3.03mm,2.38mm) for the 4mm collimator, respectively, on the SupeRay system while it was (9.5mm,10.0mm,2.9mm), (4.3mm,4.3mm,2.9mm) and (3.2mm,3.2mm,1.9mm) for the same collimator sizes, respectively, on the Perfexion system. The kV imaging system together with a non-invasive relocatable frame provides accurate target localization (<0.5mm) for cases requiring multiple treatment fractions. Conclusion: Because of the unique dosimetric properties of Co-60 sources and its accurate stereotaxy/dose delivery, SupeRay is ideally suited for single and multiple-session ablative treatments of cranial lesions. This work was partially supported by Cyber Medical Corp.

60 APPLIED LIFE SCIENCES↗

Radiation Testing for High-Resolution Radiation-Hardened Camera System (Final CRADA Report)

The nuclear energy industry needs higher-image quality and higher rad-hard vision systems for refueling and inspection operations that are required every 12-18 months for all operating commercial reactors. During refueling operations, the serial numbers of fuel assemblies need to be visually verified in a challenging high radiation environment with dose rates on the order of 1kGy/hr. at the top of the core (approximately 10 days after shutdown). Vega Wave Systems has developed and built a radiation hard vision system that: 1. has high radiation hardness, 2. demonstrated best in the industry image quality, 3. has small size and weight, and 4. does not suffer from radiation-induced noise. ANL-1060 (02/13/2023) The proprietary Enduray vision system from Vega Wave Systems, Inc. is designed to withstand more than 400x the radiation level of the Vidicon-based systems, currently the highest radiation tolerant system in use today. The Van De Graaff (VDG) electron accelerator at Argonne National Laboratory is ideally suited for testing of Enduray vision system. VDG provides a broad band (up to 3 MeV) x-ray source that reasonably approximates the energy and spectrum of the gamma radiation expected at the top of a nuclear core 10 days after shutdown (~1kGy/hr.), is easily controlled for variable tests, and will not activate the parts under radiation for ease of timely and close inspection and characterization of the system in case of operational issues.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Simulated Galactic Cosmic Ray and Solar Particle Event Radiation Effects on Inflatable Habitat, Composite Habitat, Space Suit and Space Hatch Cover Materials

The effect of particle radiation representative of galactic cosmic ray (GCR) and solar particle event (SPE) radiation on polymeric materials used in deep space mission environments is largely unknown. For NASA, this uncertainty represents an unquantified mission risk. To better quantify this risk, selected polymeric materials used in inflatable habitats, composite habitats, space suits and space hatch covers are irradiated at the Brookhaven National Laboratory, after which changes in relevant end-use properties are measured. The irradiated materials are lightweight candidates having critical functions such as ripstops, permeation barriers, micrometeoroids and orbital debris (MMOD) shield layers and restraint layers.The effect of several types of particle radiation are evaluated. To evaluate GCR effects, high-energy (1 GeV) protons and iron nucleons are used. To evaluate SPE effects, intermediate energy (ca. 20 to 40 MeV) protons are used. In addition, two mission scenarios are evaluated: a Mars mission cycle (space suit materials) and a worst-case 50 year deep space mission cycle (all materials). Lastly, a common polymer (high density polyethylene (HDPE)) is subjected to accelerated aging and radiation exposure to determine if a combined physical aging/radiation effect exists.The level of radiation induced property change observed in this study after exposure of polymers to kGy levels of intermediate and high energy ions is often significant and is quantitatively comparable to the level of change reported for similar materials exposed to MGy levels of low energy protons, electrons and gamma-radiation. This suggests that intermediate and high energy ions encountered in space may cause more damage than low energy forms of radiation due to displacement and linear energy transfer (LET) effects. For these reasons, it is recommended that final approval for mission use be made by the appropriate NASA material and structural review boards to ensure radiation induced changes in candidate materials do not interfere with their engineering function in the intended mission application. Since the materials tested in this report received doses exceeding actual mission doses, the results are considered conservative as a first approximation. However, caution must be exercised when evaluating radiation effects in the absence of other secondary factors know to contribute to degradation. In the addition to radiation type and energy, the results presented in this study show that molecular composition, orientation, stress and physical aging can also contribute to or influence degradation. Other factors such as polymer formulation, secondary radiation effects, stress, exposure to elevated temperature, thermal cycling and exposure to ozone were not investigated here, but must be considered when performing a comprehensive evaluation of a polymeric materials suitability for service in a space radiation environment. Only when the total sum of these factors operating in concert with radiation are accounted for, can accurate assessments of a material's suitability be made.

Jess M. Waller↗

Validation of general purpose mathematical efficiency modeling with ISOCS - 15579

Gamma spectroscopy is a commonly used method for radioactive waste characterization and activity determination in in-situ objects. The gamma rays emitted by radionuclides in the waste container matrix are highly penetrating and can be measured using one or more gamma ray detectors, thus allowing for a passive nondestructive assay. One problem is that a source based calibration of full energy peak efficiency can be difficult or impractical because of the large size and/or an unusual shape of the sample geometry. One attractive solution is to use mathematical efficiency modeling to calculate the full energy peak efficiency. The In-Situ Object Calibration Software (ISOCS) has successfully been used for more than a decade for mathematical efficiency modeling of template based geometries. Templates include the most common objects in waste characterization and D and D, including but not limited to: boxes, drums, and pipes with hotspots, beams, tanks and walls. Scenarios exist where these templates cannot model the desired measurement geometry. Canberra has developed a general purpose version of ISOCS where primitive objects can be combined into practically any geometry. The primitive objects are right circular cylinder, right elliptical cylinder, right circular cone, right elliptical cone, sphere, spheroid, ellipsoid, box (rectangular parallelepiped), torus, and beaker (any cylindrical symmetric object). Multiple primitive objects can be combined using the priority scheme and cut by planes into almost any desired shape. In addition, multiple objects can be defined in the same scene, for example cylinders next to each other or a pipe and a box. Collimators can be constructed as easily as in template based ISOCS. The ray tracing algorithm in ISOCS has been extended to support the new primitive objects for attenuation calculation between the radioactive source and the detector end cap. The new version uses the same vacuum efficiency response, or characterization, in the energy range 10 - 7000 keV of individual detectors to be able to calculate the efficiency as accurately as possible. MCNP has been shown to be able to calculate detection efficiencies for any geometry and the new version of ISOCS have been validated to MCNP. The vacuum efficiency is based on an MCNP model and this model was the base for constructing an identical model in MCNP as in ISOCS. The calculated efficiencies from the two codes have been compared and the agreement is within 3% except for the lowest energies for one geometry. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Neuro-behavioral Consequences of Low Dose Radiation Social Isolation and Sex Differences in the Longevity MCAT Mouse Model

The physiological responses to spaceflight elicit wide-ranging consequences and resemble aspects of aging on Earth. Previous studies have shown that oxidative damage via reactive oxygen species (ROS), contributes to aging-related pathologies. Our study uses 1-year old C57BL/6NJ male and female mice (astronaut-relevant age) that underwent exposure to 0.5 gray of gamma radiation together with social isolation and were euthanized 12 weeks after. We used the longevity MCAT mouse model in which human catalase is overexpressed in the mitochondria, for ROS quenching. We aimed to determine whether in older mice quenching ROS, will mitigate the neuro-behavioral consequences of low dose ionizing radiation and/or social isolation and whether the outcomes will differ in males and females. We have performed five mission relevant behavioral tests which focused on performance, memory, physical stance, and stress. We have detected both sex and radiation effects; the older females look physically better are faster and perform better almost in all behavioral tests compared to their male counterparts. On the other hand, they are more sensitive to low dose radiation in many cases, in some cases this effect was indeed mitigated in the MCAT mice, pointing out to the importance of ROS in response to radiation stress and social isolation. We have measured plasma (7- and 90-days post radiation), cytokines, corticosterone and hippocampal cytokine and microglial activation at the end of the experiment. We saw significant changes in the plasma markers due to radiation, sex, and genotype in both short and long post radiation period and detected long term sex and radiation effects in the brain. Our focus is now on applying advanced statistical modeling to corelate the behavioral tests with our recent molecular findings to look for specific biomarkers that could predict behavioral deficits.

radiation↗

Rare B{sub (s)} decays in the standard model and in a scenario with two universal extra dimensions

I consider the exclusive B{yields}K*{gamma}, B{yields}K*{sub 2}{gamma}, B{sub s}{yields}{phi}{gamma} and B{yields}K{eta}{sup ( Prime )}{gamma} radiative decays in the Standard Model and in a scenario with two universal extra dimensions compactified on a chiral square. Computed branching fractions depend on 1/R, the size of the extra dimensions, so that comparison with available data allows to put bounds on such a parameter. The most stringent bound comes from the mode B*{sup 0}{yields}K*{sup 0}{gamma} and reads: 1/R > 710 GeV.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Radiation and Nuclear Materials Detection Research and Development at ORNL

Research and development is underway to improve radiation and nuclear detection capabilities. This research and development in radiation and nuclear detection includes areas such as advanced materials, applied research and engineering for designing and fabricating customized detection equipment, and theoretical modeling and computational support. Oak Ridge National Laboratory (ORNL) has a distinctive set of detector materials fabrication and characterization capabilities and recently created a Center for Radiation Detection Materials and Systems. Applied research and engineering efforts have led to the development of improved detectors for specific applications including safeguards, treaty monitoring, and science experiments. All sizes, types, and capabilities of detector systems have been addressed from miniature to man-portable and from neutrons to gamma radiation. Dedicated test beds, in-house and in the field, have been established to analyze, characterize, and improve detection systems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Neutron-Irradiated Samples as Test Materials for MPEX

Plasma Material Interaction (PMI) is a major concern in fusion reactor design and analysis. The Material-Plasma Exposure eXperiment (MPEX) will explore PMI under fusion reactor plasma conditions. Samples with accumulated displacements per atom (DPA) damage produced by fast neutron irradiations in the High Flux Isotope Reactor (HFIR) at Oak Ridge National Laboratory (ORNL) will be studied in the MPEX facility. This paper presents assessments of the calculated induced radioactivity and resulting radiation dose rates of a variety of potential fusion reactor plasma-facing materials (such as tungsten). The scientific code packages MCNP and SCALE were used to simulate irradiation of the samples in HFIR including the generation and depletion of nuclides in the material and the subsequent composition, activity levels, gamma radiation fields, and resultant dose rates as a function of cooling time. A challenge of the MPEX project is to minimize the radioactive inventory in the preparation of the samples and the sample dose rates for inclusion in the MPEX facility.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Optical reprocessing of gamma-ray bursts

One model for the optical flashes associated with three cosmic gamma-ray burst sources invokes the reprocessing of some of the gamma-radiation emitted by a hypothesized collapsed object in the surface layers of a nearby companion star. This model was investigated by carrying out detail, fully hydrodynamical calculations of such reprocessing in the surface layers of very low mass stars. It is found that, at most, 7 percent of the gamma-ray fluence incident on the companion star is reprocessed into the blue band; the time scale for this reprocessing is typically 100 s, which is long compared to the duration of the gamma-ray burst itself. Using this result, it is shown that there is marginal agreement between the observed and calculated ratios of gamma-ray fluence to optical fluence at earth.

Melia, F.↗

SHIELDING AND DETECTOR RESPONSE CALCULATIONS PERTAINING TO CATEGORY 1 QUANTITIES OF PLUTONIUM AND HAND-HELD PLASTIC SCINTILLATORS

Nuclear facilities sometimes use hand-held plastic scintillator detectors to detect attempts to divert special nuclear material in situations where portal monitors are impractical. MCNP calculations have been performed to determine the neutron and gamma radiation field arising from a Category I quantity of weapons-grade plutonium in various shielding configurations. The shields considered were composed of combinations of lead and high-density polyethylene such that the mass of the plutonium plus shield was 22.7 kilograms. Monte-Carlo techniques were also used to determine the detector response to each of the shielding configurations. The detector response calculations were verified using field measurements of high-, medium-, and low- energy gamma-ray sources as well as a Cf-252 neutron source.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Antiproton powered propulsion with magnetically confined plasma engines

Matter-antimatter annihilation releases more energy per unit mass than any other method of energy production, making it an attractive energy source for spacecraft propulsion. In the magnetically confined plasma engine, antiproton beams are injected axially into a pulsed magnetic mirror system, where they annihilate with an initially neutral hydrogen gas. The resulting charged annihilation products transfer energy to the hydrogen propellant, which is then exhausted through one end of the pulsed mirror system to provide thrust. The calculated energy transfer efficiencies for a low number density (10(14)/cu cm) hydrogen propellant are insufficient to warrant operating the engine in this mode. Efficiencies are improved using moderate propellant number densities (10(16)/cu cm), but the energy transferred to the plasma in a realistic magnetic mirror system is generally limited to less than 2 percent of the initial proton-antiproton annihilation energy. The energy transfer efficiencies are highest for high number density (10(18)/cu cm) propellants, but plasma temperatures are reduced by excessive radiation losses. Low to moderate thrust over a wide range of specific impulse can be generated with moderate propellant number densities, while higher thrust but lower specific impulse may be generated using high propellant number densities. Significant mass will be required to shield the superconducting magnet coils from the high energy gamma radiation emitted by neutral pion decay. The mass of such a radiation shield may dominate the total engine mass, and could severely diminish the performance of antiproton powered engines which utilize magnetic confinement. The problem is compounded in the antiproton powered plasma engine, where lower energy plasma bremsstrahlung radiation may cause shield surface ablation and degradation.

Lapointe, Michael R.↗

{beta} decay of 129Cd and excited states in 129In

The β decay of Cd 129 , produced in the relativistic fission of a U 238 beam, was experimentally studied at the RIBF facility at the RIKEN Nishina Center. From the γ radiation emitted after the β decays, a level scheme of In 129 was established comprising 31 excited states and 69 γ -ray transitions. The experimentally determined level energies are compared to state-of-the-art shell-model calculations. The half-lives of the two β -decaying states in Cd 129 were deduced and the β feeding to excited states in In 129 were analyzed. It is found that, as in most cases in the Z<50 , N≤82 region, both decays are dominated by the ν0g 7/2 →π0g 9/2 Gamow–Teller transition, although the contribution of first-forbidden transitions cannot be neglected.

Taprogge, J.↗

Design of a high-temperature cell for cobalt-60 irradiations of aqueous solutions with in situ UV–visible spectroscopy

To understand the speciation of solutes in aqueous solutions in high temperature radiation environments, we report the design and fabrication of a custom-built, high temperature (≤300 °C) titanium irradiation cell with in situ optical spectroscopy capabilities, as afforded by coupled fiber optic cables. The wetted surfaces of the 8-inch tall cylindrical cell with 3.5 in. diameter are entirely made of titanium, sapphire, and gold, which are chemically and radiolytically inert. The initial benchmarking results are reported, including the baseline spectrum of deionized water as a function of temperature, the stability of a spectrum over 4 h at 100 °C, and an irradiated Fricke dosimetry solution under ambient irradiator temperature conditions (27.0 ± 0.5 °C). Further, the average gamma radiation dose rate in the cell in its current configuration is 26.1 ± 1.3 Gy min -1 . This cell has application in studying several processes throughout the nuclear fuel cycle, including the reactor coolant behavior.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Stacking Searches for Greater Than 100 MeV Gamma Ray Emission from Radio Galaxies and Seyfert Galaxies

The EGRET telescope on CGRO detected more than sixty sources of high-energy gamma radiation associated with active galactic nuclei (AGN). All but one of those belong to the blazar subclass; the only exception is the nearby radio galaxy Centaurus A. Since there is no obvious reason other than proximity to expect Cen A to be the only non-blazar AGN emitting in high-energy gamma rays, we have utilized the "stacking" technique to search for $>100$-MeV emission from two non-blazar AGN subclasses, radio galaxies and Seyfert galaxies. Maps of gamma-ray counts, exposure, and diffuse background have been created, then co-added in varying numbers based on sorts by redshift, 5-GHZ flux density, and optical brightness, and finally tested for gamma-ray emission. No detection significance greater than $2\sigma$ has been found for any subclass, sorting parameter, or number of objects co-added. Monte Carlo simulations have also been performed, to validate the technique and estimate the significance of the results.

Cillis, A. N.↗

Changes in Liver Metabolic Gene Expression from Radiation Exposure

Radiation exposure is one of the unique physiological challenges of human spaceflight that is not encountered on earth. While radiation exposure is known to impart physiological stresses and alter normal function, it is unclear how it specifically affects drug metabolism. A major concern is that the actions of medications used in spaceflight may deviate from the expectations formed from terrestrial use. This concern was investigated at the molecular level by analyzing how gamma radiation exposure affected gene expression in the livers of mice. Three different doses of radiation were administered and after various intervals of recovery time, gene expression was measured with RT-qPCR screening arrays for drug metabolism and DNA repair. After examining the results of 192 genes total from each of 72 mice, 65 genes were found to be significantly affected by at least one of the doses of radiation. In general, the genes affected are involved in the metabolism of drugs with lipid or steroid hormone-like structures, as well as the maintenance of redox homeostasis and repair of DNA damage.

Peters, C. P.↗

Validation of Spent Fuel Dose Rate Calculations Using NDA Measurement Campaign Data

The predicted radiation gamma dose rate is a key parameter to determine if a spent nuclear fuel assembly is self-protected from misuse as well as an indicator for worker/inspector safety. Recent studies showed that using state-of-the-art techniques for dose rate calculations, including the one adopted for this study, the numerical calculations of the gamma dose rates are three times lower than those from the most commonly-cited reference values for spent LWR fuel used by domestic and international agencies. With only a few publically available experimental data points worldwide for this type of benchmark study, the gamma flux measurements from the Spent Fuel Non Destructive Assay (NDA) measurement campaign can be used to help validate the physics approach used in calculating gamma dose rates. Specifically, this data would validate the gamma flux calculation from spent fuel, which is a key component of these multi-physics techniques for dose rate assessments; dose rate measurements were not part of the NDA campaign. These data are primarily the passive gamma measurements of the spent nuclear fuel assemblies from the Swedish Nuclear Fuel and Waste Management Company (SKB).

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗