Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Functionally Graded”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 883 records · Page 49

Model-Driven Development of Reliable Avionics Architectures for Lunar Surface Systems

This paper discusses a method used for the systematic improvement of NASA s Lunar Surface Systems avionics architectures in the area of reliability and fault-tolerance. This approach utilizes an integrated system model to determine the effects of component failure on the system s ability to provide critical functions. A Markov model of the potential degraded system modes is created to characterize the probability of these degraded modes, and the system model is run for each Markov state to determine its status (operational or system loss). The probabilistic results from the Markov model are first produced from state transition rates based on NASA data for heritage failure rate data of similar components. An additional set of probabilistic results are created from a representative set of failure rates developed for this study, for a variety of component quality grades (space-rated, mil-spec, ruggedized, and commercial). The results show that careful application of redundancy and selected component improvement should result in Lunar Surface Systems architectures that exhibit an appropriate degree of fault-tolerance, reliability, performance, and affordability.

Borer, Nicholas↗

On the grade consistent theories of micromorphic elastic solids

For the investigation of specific nonlocal phenomena the second-order displacement gradient has been added to the independent constitutive variables used in the classical theories of elastic solids. In this paper we outline the hystorical development of the subject and present a nonlinear grade consistent theory of micromorphic elastic solids in which the independent constitutive variables are the deformation gradient, the second-order displacement gradient, microdeformation tensor, and microdeformation gradient. Then, we present the linearized theory and establish a uniqueness result with no definiteness assumption on the elastic coefficients. The theory is used to obtain the basic eqations of a grade consistent theory of microstretch elastic bodies. The field equations for an isotropic and homogeneous elastic body are presented. A counterpart of the Cauchy-Kowalevski-Somigliana solution of the classical elastodynamics is established.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

GaN HEMT Fabrication for Radiation-Hardened Sensing and Communications Electronics

Gallium nitride (GaN), a wide bandgap semiconductor, has vast potential to address two environment conditions associated with the application of electronics to nuclear power: elevated temperatures, and high levels of radiation. A process was developed at The Ohio State University (OSU) to enable fabrication of complex digital and analog electronics circuits for application to nuclear power environments such as locations near or in the reactor core or in spent nuclear fuel casks. Radio frequency (RF)-grade GaN high electron mobility transistor (HEMT) devices were fabricated as part of this process. These were fabricated as depletion mode and enhancement mode devices. They have been electrically characterized and have demonstrated the expected performance. Behavioral models (Verilog-A) were developed from these device measurements to enable electrical simulation of GaN HEMT devices and circuits using common electronics simulation tools based on Simulation Program with Integrated Circuit Emphasis (SPICE). A similar set of GaN HEMT devices is being developed to provide lower speed devices for logic and analog functions. These accomplishments position this technology for effective application to sensor interfacing, signal processing, and data communications in nuclear power plants, including operation in or near the reactor core.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Design and Performance of the Vegetation Canopy Lidar (VCL) Laser Transmitter

The Vegetation Canopy Lidar (VCL) laser is a Nd:YAG Q-switched, diode side-pumped, zig-zag slab design producing 10 ns, 15 mJ pulses at 1064 nm. It employs an unstable resonator as well as a graded reflectivity output coupler with a Gaussian reflectivity profile. In order to conserve power, a conductively cooled design is employed and is designed to operate over a range of 25 C without active thermal control. The laser is an oscillator-only design and equipped with an 15X beam expander to limit the output divergence to less than 60 microrad. Thermal lensing compensation in the side-pumped slab was performed with different treatments of the x and y portions of the z-directed beam. Performance data as a function of temperature are given.

Coyle, D. Barry↗

Biosensors for EVA: Improved Instrumentation for Ground-based Studies

During lunar excursions in the EVA suit, real-time measurement of metabolic rate is required to manage consumables and guide activities to ensure safe return to the base. Metabolic rate, or oxygen consumption (VO2), is normally measured from pulmonary parameters but cannot be determined with standard techniques in the oxygen-rich environment of a spacesuit. Our group has developed novel near infrared spectroscopic (NIRS) methods to calculate muscle oxygen saturation (SmO 2), hematocrit, and pH, and we recently demonstrated that we can use our NIRS sensor to measure VO 2 on the leg during cycling. Our NSBRI project has 4 objectives: (1) increase the accuracy of the metabolic rate calculation through improved prediction of stroke volume; (2) investigate the relative contributions of calf and thigh oxygen consumption to metabolic rate calculation for walking and running; (3) demonstrate that the NIRS-based noninvasive metabolic rate methodology is sensitive enough to detect decrement in VO 2 in a space analog; and (4) improve instrumentation to allow testing within a spacesuit. Over the past year we have made progress on all four objectives, but the most significant progress was made in improving the instrumentation. The NIRS system currently in use at JSC is based on fiber optics technology. Optical fiber bundles are used to deliver light from a light source in the monitor to the patient, and light reflected back from the patient s muscle to the monitor for spectroscopic analysis. The fiber optic cables are large and fragile, and there is no way to get them in and out of the test spacesuit used for ground-based studies. With complimentary funding from the US Army, we undertook a complete redesign of the sensor and control electronics to build a novel system small enough to be used within the spacesuit and portable enough to be used by a combat medic. In the new system the filament lamp used in the fiber optic system was replaced with a novel broadband near infrared LED light source. The compact grating spectrometer was replaced with a chip-scale spectrometer. With this new design, the sensor is 4 in 2 in 0.5 in, weighs 60 g, and no fiber optic cables are needed. The sensor, which contains the light source and the spectrometer, is adhered directly to the skin with medical grade adhesive. The sensor can be powered via the USB port of the laptop computer that controls the sensor operation. Alternatively, for studies in the spacesuit, the sensor can be powered by a small battery pack and operated by an ultra-portable hand-held computer. Both the handheld computer and battery pack will easily fit within the PLSS of the test spacesuit. System automation was significantly improved, to add features suggested by our colleagues in the Cardiovascular Laboratory and the NASA JSC Exercise Physiology and Countermeasures Project. The functionality and portability of this system were demonstrated in our UMass laboratory.

Soller, B.↗

Patterns of Response After Preoperative Intensity-Modulated Radiation Therapy and Capecitabine/Oxaliplatin in Rectal Cancer: Is There Still a Place for Ecoendoscopic Ultrasound?

Purpose: The main goals of preoperative chemoradiotherapy (CHRT) in rectal cancer are to achieve pathological response and to ensure tumor control with functional surgery when possible. Assessment of the concordance between clinical and pathological responses is necessary to make decisions regarding alternative conservative procedures. The present study evaluates the patterns of response after a preoperative CHRT regimen, and the value of endoscopic ultrasound (EUS) in assessing response. Methods and Materials: A total of 51 EUS-staged T3 to T4 and/or N0 to N+ rectal cancer patients received preoperative CHRT (intensity-modulated radiation therapy and capecitabine/oxaliplatin (XELOX) followed by radical resection. Clinical response was assesed by EUS. Rates of pathological tumor regression grade (TRG) and lymph node (LN) involvement were determined in the surgical specimen. Clinical and pathological responses were compared, and the accuracy of EUS in assessing response was calculated. Results: Twenty-four patients (45%) achieved a major pathological response (complete or >95% pathological response (TRG 3+/4)). Sensitivity, specificity, negative predictive value, and positive predictive value of EUS in predicting pathological T response after preoperative CHRT were 77.8%, 37.5%, 60%, and 58%, respectively. The EUS sensitivity, specificity, negative predictive value, and positive predictive value for nodal staging were 44%, 88%, 88%, and 44%, respectively. Furthermore, EUS after CHRT accurately predicted the absence of LN involvement in 7 of 7 patients (100%) with major pathological response of the primary tumor. Conclusion: Preoperative IMRT with concomitant XELOX induces favorable rates of major pathological response. EUS has a limited ability to predict primary tumor response after preoperative CHRT, but it is useful for accurately determining LN status. EUS may have a potential value in identifying patients with a very low risk of LN involvement in association with a good pathological response as potential candidates for conservative local surgical protocols.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Research to Develop Flood Barrier Testing Strategies for Nuclear Power Plants

The U.S. Nuclear Regulatory Commission has developed regulations regarding the siting and design of nuclear power plants (NPPs) that are aimed at addressing various natural hazards, including flooding. Flood barriers are designed to prevent water from entering NPP areas containing structures, systems, and components (SSCs) important to safety. The barriers are used at NPPs along with drains, sumps, pumps, valves, plugs, and site grading as part of the plant flood protection features that protect SSCs from experiencing external or internal flooding and mitigate the effects of flooding on NPP operations. The performance of flood protection features, including flood barriers at NPPs, has been an ongoing concern. Domestic and international operational experience provides clear indications that flood barrier performance has significant safety implications, especially for aging NPPs. The observed deficiencies show that flood barriers should be designed and installed properly, then adequately tested, inspected, and maintained in order to ensure that they perform their intended functions during flooding events. Here, this paper reviews available information related to flood barriers employed at U.S. NPPs and provides an overview and categorization of NPP flood barriers. It identifies potential domestic and international flood barrier testing facilities, including operating and decommissioned U.S. NPPs. Finally, this paper presents the technical and logistical considerations that should be made when developing specific testing strategies and protocols for flood barriers, such as the selection of flood barriers, test locations, testing approach, performance criteria, and testing parameters.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Making the Traffic Operations Case for Congestion Pricing: Operational Impacts of Congestion Pricing

Congestion begins when an excess of vehicles on a segment of roadway at a given time, resulting in speeds that are significantly slower than normal or 'free flow' speeds. Congestion often means stop-and-go traffic. The transition occurs when vehicle density (the number of vehicles per mile in a lane) exceeds a critical level. Once traffic enters a state of congestion, recovery or time to return to a free-flow state is lengthy; and during the recovery process, delay continues to accumulate. The breakdown in speed and flow greatly impedes the efficient operation of the freeway system, resulting in economic, mobility, environmental and safety problems. Freeways are designed to function as access-controlled highways characterized by uninterrupted traffic flow so references to freeway performance relate primarily to the quality of traffic flow or traffic conditions as experienced by users of the freeway. The maximum flow or capacity of a freeway segment is reached while traffic is moving freely. As a result, freeways are most productive when they carry capacity flows at 60 mph, whereas lower speeds impose freeway delay, resulting in bottlenecks. Bottlenecks may be caused by physical disruptions, such as a reduced number of lanes, a change in grade, or an on-ramp with a short merge lane. This type of bottleneck occurs on a predictable or 'recurrent' basis at the same time of day and same day of week. Recurrent congestion totals 45% of congestion and is primarily from bottlenecks (40%) as well as inadequate signal timing (5%). Nonrecurring bottlenecks result from crashes, work zone disruptions, adverse weather conditions, and special events that create surges in demand and that account for over 55% of experienced congestion. Figure 1.1 shows that nonrecurring congestion is composed of traffic incidents (25%), severe weather (15%), work zones, (10%), and special events (5%). Between 1995 and 2005, the average percentage change in increased peak traveler delay, based on hours spent in traffic in a year, grew by 22% as the national average of hours spent in delay grew from 36 hours to 44 hours. Peak delay per traveler grew one-third in medium-size urban areas over the 10 year period. The traffic engineering community has developed an arsenal of integrated tools to mitigate the impacts of congestion on freeway throughput and performance, including pricing of capacity to manage demand for travel. Congestion pricing is a strategy which dynamically matches demand with available capacity. A congestion price is a user fee equal to the added cost imposed on other travelers as a result of the last traveler's entry into the highway network. The concept is based on the idea that motorists should pay for the additional congestion they create when entering a congested road. The concept calls for fees to vary according to the level of congestion with the price mechanism applied to make travelers more fully aware of the congestion externality they impose on other travelers and the system itself. The operational rationales for the institution of pricing strategies are to improve the efficiency of operations in a corridor and/or to better manage congestion. To this end, the objectives of this project were to: (1) Better understand and quantify the impacts of congestion pricing strategies on traffic operations through the study of actual projects, and (2) Better understand and quantify the impacts of congestion pricing strategies on traffic operations through the use of modeling and other analytical methods. Specifically, the project was to identify credible analytical procedures that FHWA can use to quantify the impacts of various congestion pricing strategies on traffic flow (throughput) and congestion.

99 GENERAL AND MISCELLANEOUS↗

SPECs Early-Stage Decision Model: User Manual

The SPECs Early-Stage Decision (ESD) model is central to the SPECs procurement solutions toolkit. The ESD model is an Excel-based spreadsheet model, which provides information about the economic and strategic value of a proposed battery-storage project or solar-plus-storage (solar-plus) project. The model can be used to explore combinations of storage-related project value streams in order to define a potential project, while educating co-op decision-makers about project benefits and costs. A sensitivity analysis function speeds the development of "what-if" scenarios. A gap analysis function solves for top-priority metrics and supports the inclusion of hard-to-monetize strategic values, such as the value of storage to defer costly system upgrades in light of increasing distributed solar and other distributed energy resources (DERs). Model outputs include the utility data, assumptions, and use-case scenarios that are recommended content for the requests for proposals (RFPs). The model may also provide an initial "sanity check" for RFP responses, supporting further discussions among utility staff, vendors and stakeholders. The ESD is not a "finance-grade" modeling tool, and users are cautioned to be mindful of its limitations, but the model has been reviewed by users, who recommend it as a way to drive faster and better project design and planning, as well as to facilitate better communications with vendors, grid partners, and stakeholders.

14 SOLAR ENERGY↗

Effects of Texture and Silica Content on Crack Growth in Boron Nitrides

Boron nitride is used in applications such as crucibles for melting and casting glasses and metals, insulators for furnaces, molds for hot pressing, and neutron absorbers. Historically, various grades of hot pressed hexagonal boron nitride (BN) have been used. This study investigates the fracture toughness and slow crack growth parameters of several commercially available BN grades. Prior work revealed that some grades of BN absorb water and change strength, thus presenting a philosophical conundrum on crack growth test methods. The grades selected for this study are of interest because their available billet size is sufficient for large components, or because they have heritage in specific applications. Ultimately, the data will be used to perform material selection, system design and reliability analyses of components of interest. Boron nitrides exhibit limited slow crack growth in humidity, with an orientation dependence due to crystallographic texture: orientations with van der Waal bonds are insensitive to water whereas those with covalent bonds are sensitive. Fracture toughness is low, around that of glass, and is also a function of orientation (bond type), with fracture occurring more readily along van der Waal bonds between hexagonal BN platelets than at covalent bonds across platelets. Silica additions toughen BN, but increase slow crack growth susceptibility.

Salem, Jonathan A.↗

Radiosurgery for Large Brain Metastases

Purpose: To determine the efficacy and safety of radiosurgery in patients with large brain metastases treated with radiosurgery. Patients and Methods: Eighty patients with large brain metastases (>14 cm{sup 3}) were treated with radiosurgery between 1998 and 2009. The mean age was 59 {+-} 11 years, and 49 (61.3%) were men. Neurologic symptoms were identified in 77 patients (96.3%), and 30 (37.5%) exhibited a dependent functional status. The primary disease was under control in 36 patients (45.0%), and 44 (55.0%) had a single lesion. The mean tumor volume was 22.4 {+-} 8.8 cm{sup 3}, and the mean marginal dose prescribed was 13.8 {+-} 2.2 Gy. Results: The median survival time from radiosurgery was 7.9 months (95% confidence interval [CI], 5.343-10.46), and the 1-year survival rate was 39.2%. Functional improvement within 1-4 months or the maintenance of the initial independent status was observed in 48 (60.0%) and 20 (25.0%) patients after radiosurgery, respectively. Control of the primary disease, a marginal dose of {>=}11 Gy, and a tumor volume {>=}26 cm{sup 3} were significantly associated with overall survival (hazard ratio, 0.479; p = .018; 95% CI, 0.261-0.880; hazard ratio, 0.350; p = .004; 95% CI, 0.171-0.718; hazard ratio, 2.307; p = .006; 95% CI, 1.274-4.180, respectively). Unacceptable radiation-related toxicities (Radiation Toxicity Oncology Group central nervous system toxicity Grade 3, 4, and 5 in 7, 6, and 2 patients, respectively) developed in 15 patients (18.8%). Conclusion: Radiosurgery seems to have a comparable efficacy with surgery for large brain metastases. However, the rate of radiation-related toxicities after radiosurgery should be considered when deciding on a treatment modality.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Tumor histology and location predict deep nuclei toxicity: Implications for late effects from focal brain irradiation

Normal tissue toxicity resulting from both disease and treatment is an adverse side effect in the management of patients with central nervous system malignancies. We tested the hypothesis that despite these improvements, certain tumors place patients at risk for neurocognitive, neuroendocrine, and neurosensory late effects. Defining patient groups at risk for these effects could allow for development of preventive strategies. Fifty patients with primary brain tumors underwent radiation planning with magnetic resonance imaging scan and computed tomography datasets. Organs at risk (OAR) responsible for neurocognitive, neuroendocrine, and neurosensory function were defined. Inverse-planned intensity-modulated radiation therapy was optimized with priority given to target coverage while penalties were assigned to exceeding normal tissue tolerances. Tumor laterality, location, and histology were compared with OAR doses, and analysis of variance was performed to determine the significance of any observed correlation. The ipsilateral hippocampus exceeded dose limits in frontal (74%), temporal (94%), and parietal (100%) lobe tumor locations. The contralateral hippocampus was at risk in the following tumor locations: frontal (53%), temporal (83%), or parietal (50%) lobe. Patients with high-grade glioma were at risk for ipsilateral (88%) and contralateral (73%) hippocampal damage (P <0.05 compared with other histologies). The pituitary gland and hypothalamus exceeded dose tolerances in patients with pituitary tumors (both 100%) and high-grade gliomas (50% and 75%, P <0.05 compared with other histologies), respectively. Despite application of modern radiation therapy, certain tumor locations and histologies continue to place patients at risk for morbidity. Patients with high-grade gliomas or tumors located in the frontal, temporal, or parietal lobes are at risk for neurocognitive decline, likely because of larger target volumes and higher radiation doses. Data from this study may help to stratify patients at risk for late effects to develop strategies to reduce frequency and severity of radiation sequelae.

61 RADIATION PROTECTION AND DOSIMETRY↗

The 30/20 GHz mixed user architecture development study: Executive summary

The baseline 30/30 GHz satellite communication system, designed for cost-effective communications in the years 1990 to 2000, incorporates on-board satellite demodulation and routing of individual 64 kbps digital voice-grade circuits. This level of routing flexibility is necessary to provide efficient communications to the large number of direct-to-user terminals (DTU) projected. The circuit interfacing hardware is distributed among all the DTU and master control stations. The switching circuitry which provides full interconnectivity between 30 to 45 thousand circuits is in the satellite. The DTU terminal cost, perhaps the largest element in the system cost, represents the largest economic value element of the system because it avoids using terrestrial signal distribution and routing and the charges associated with these functions. Satellite baseline design and power requirements for the system are examined.

Source record↗

Fractionated Conformal Radiotherapy in the Management of Cavernous Sinus Meningiomas: Long-Term Functional Outcome and Tumor Control at a Single Institution

Purpose: To evaluate long-term outcome of cavernous sinus meningioma (CSM) treated with fractionated conformal radiotherapy (FCR). Patients and Methods: Fifty-three patients with CSMs (16 men [30.2%], 37 women [69.8%], aged 53 {+-} 13.0 years [mean {+-} SD]) were treated by FCR. In 28 patients (52.8%) FCR was performed as first-line treatment and in 25 patients (47.2%) as adjuvant treatment. All patients received FCR with a dose of 52.9 {+-} 1.8 Gy in 29.4 {+-} 1.0 fractions over 6 weeks. Dose per fraction was 1.9 {+-} 0.1 Gy. Radiotherapy was delivered stereotactically in 47 cases (88.7%) and conformally in 6 (11.3%) Results: The median follow-up was 6.9 years (range, 3-19 years). According to Sekhar's classification, 19 patients (35.8%) were Grade 1-2, 30 patients (56.6%) were Grade 3-4, and 4 patients (7.6%) were Grade 5. Pretreatment tumor volume was determined in 46 patients, and tumor volume was 12.6 {+-} 8.2 cm{sup 3}. In these patients, the distance between tumor and optic apparatus was 1.62 {+-} 1.2 mm. Actuarial 5- and 10-year progression-free survival rates were 98.1% and 95.8%, respectively. Clinical improvement was observed in 31 patients (58.5%), and 20 patients (37.7%) remained unchanged. Radiologic response was observed in 18 patients (30.2%), and 35 patients (66.0%) showed stable lesions. Two patients (3.8%) showed tumor progression during follow-up. Transient morbidity was observed in 3 patients (5.7%) and permanent morbidity in 1 (1.9%). Conclusion: Fractionated conformal radiotherapy affords satisfactory long-term tumor control and low treatment morbidity.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

No Clinically Significant Changes in Pulmonary Function Following Stereotactic Body Radiation Therapy for Early- Stage Peripheral Non-Small Cell Lung Cancer: An Analysis of RTOG 0236

Purpose: To investigate pulmonary function test (PFT) results and arterial blood gas changes (complete PFT) following stereotactic body radiation therapy (SBRT) and to see whether baseline PFT correlates with lung toxicity and overall survival in medically inoperable patients receiving SBRT for early stage, peripheral, non-small cell lung cancer (NSCLC). Methods and Materials: During the 2-year follow-up, PFT data were collected for patients with T1-T2N0M0 peripheral NSCLC who received effectively 18 Gy × 3 in a phase 2 North American multicenter study (Radiation Therapy Oncology Group [RTOG] protocol 0236). Pulmonary toxicity was graded by using the RTOG SBRT pulmonary toxicity scale. Paired Wilcoxon signed rank test, logistic regression model, and Kaplan-Meier method were used for statistical analysis. Results: At 2 years, mean percentage predicted forced expiratory volume in the first second and diffusing capacity for carbon monoxide declines were 5.8% and 6.3%, respectively, with minimal changes in arterial blood gases and no significant decline in oxygen saturation. Baseline PFT was not predictive of any pulmonary toxicity following SBRT. Whole-lung V5 (the percentage of normal lung tissue receiving 5 Gy), V10, V20, and mean dose to the whole lung were almost identical between patients who developed pneumonitis and patients who were pneumonitis-free. Poor baseline PFT did not predict decreased overall survival. Patients with poor baseline PFT as the reason for medical inoperability had higher median and overall survival rates than patients with normal baseline PFT values but with cardiac morbidity. Conclusions: Poor baseline PFT did not appear to predict pulmonary toxicity or decreased overall survival after SBRT in this medically inoperable population. Poor baseline PFT alone should not be used to exclude patients with early stage lung cancer from treatment with SBRT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Use of the drift-time method to measure the electron lifetime in long-drift-length CdZnTe detectors

The traditional method for electron lifetime measurements of CdZnTe (CZT) detectors relies on using the Hecht equation. The procedure involves measuring the dependence of the detector response on the applied bias to evaluate the μτ product, which in turn can be converted into the carrier lifetime. Despite general acceptance of this technique, which is very convenient for comparative testing of different CZT materials, the assumption of a constant electric field inside a detector is unjustified. In the Hecht equation, this assumption means that the drift time would be a linear function of the distance. This condition is not fulfilled in practice at low applied biases, where the Hecht equation is most sensitive to the μτ product. As a result, researchers usually take measurements at relatively high biases, which work well in the case of the low μτ-product material, <10 -3 cm 2 /V, but give significantly underestimated values for the case of high μτ-product crystals. In this paper, we applied the drift-time method to measure the electron lifetimes in long-drift-length (4 cm) standard-grade CZT detectors produced by the Redlen Technologies. We found that the electron μτ product of tested crystals is in the range 0.1–0.2 cm 2 /V, which is an order of the magnitude higher than any value previously reported for a CZT material. Finally, in comparison, using the Hecht equation fitting, we obtained μτ = 2.3 × 10 -2 cm 2 /V for a 2-mm thin planar detector fabricated from the same CZT material.

47 OTHER INSTRUMENTATION↗

MATERIAL CONTROL ACCOUNTING INMM

Since 1996, the Mining and Chemical Combine (MCC - formerly known as K-26), and the United States Department of Energy (DOE) have been cooperating under the cooperative Nuclear Material Protection, Control and Accounting (MPC&A) Program between the Russian Federation and the U.S. Governments. Since MCC continues to operate a reactor for steam and electricity production for the site and city of Zheleznogorsk which results in production of the weapons grade plutonium, one of the goals of the MPC&A program is to support implementation of an expanded comprehensive nuclear material control and accounting (MC&A) program. To date MCC has completed upgrades identified in the initial gap analysis and documented in the site MC&A Plan and is implementing additional upgrades identified during an update to the gap analysis. The scope of these upgrades includes implementation of MCC organization structure relating to MC&A, establishing material balance area structure for special nuclear materials (SNM) storage and bulk processing areas, and material control functions including SNM portal monitors at target locations. Material accounting function upgrades include enhancements in the conduct of physical inventories, limit of error inventory difference procedure enhancements, implementation of basic computerized accounting system for four SNM storage areas, implementation of measurement equipment for improved accountability reporting, and both new and revised site-level MC&A procedures. This paper will discuss the implementation of MC&A upgrades at MCC based on the requirements established in the comprehensive MC&A plan developed by the Mining and Chemical Combine as part of the MPC&A Program.

99 GENERAL AND MISCELLANEOUS↗

Evaluation of pGL1-TNF-alpha therapy in combination with radiation

Long-term control of high-grade brain tumors is rarely achieved with current therapeutic regimens. In this study a new plasmid-based human tumor necrosis factor-alpha (TNF-alpha) expression vector was synthesized (pGL1-TNF-alpha) and evaluated together with radiation in the aggressive, rapidly growing C6 rat glioma model. pGL1-TNF-alpha was successfully transfected into C6 cells in vitro using a cationic polyamine method. Expression was detected up to 7 days and averaged 0.4 ng of TNF-alpha in the culture medium from 1x10(5) cells. The expressed protein was biologically functional, as evidenced by growth inhibition of L929, a TNF-alpha-susceptible cell line. Using fluorescence-labeled monoclonal antibodies and laser scanning cytometry, we confirmed that both the P55 and P75 receptors for TNF-alpha were present on the C6 cell membrane. However, the receptors were present at low density and P55 was expressed more than the P75 receptor. These findings were in contrast to results obtained with TNF-alpha-susceptible L929 cells. Tests in athymic mice showed that pGL1-TNF-alpha administered intratumorally 16-18 h before radiation (each modality given three times) significantly inhibited C6 tumor progression (P<0.05). This effect was more than additive, because pGL1-TNF-alpha alone did not slow tumor growth and radiation alone had little effect on tumor growth. These results indicate that pGL1-TNF-alpha has potential to augment the antitumor effects of radiation against a tumor type that is virtually incurable.

Non-NASA Center↗