Tunable semiconductor laser with two acousto-optic tunable filters in its external cavity

We report a laser with a linear external cavity containing a near-IR injection semiconductor optical amplifier as a gain element and two acousto-optic tunable filters (AOTFs) with quasi-collinear interaction of acoustic and light waves. At identical frequencies of RF signals that control the filters and ensure compensation for the Doppler frequency shift of light passing through the AOTFs, the steady-state laser emission linewidth can be reduced to about 25 MHz, which is almost three orders of magnitude smaller than that in the case of one filter (20 GHz). The position of the emission line, which remains narrow, slowly fluctuates within a spectral range about 3 GHz wide, which seems to be due to the large length of the external cavity and insufficient thermal stabilization of its components. This does not prevent us from obtaining light with a large coherence length. In emission wavelength sweep mode, the instantaneous emission linewidth increases with tuning rate, reaching 0.022 nm (8.8 GHz) at the highest tuning rate: 10{sup 4} nm s{sup −1}. In the case of automatic control over the output optical power at a level of 3 mW, the tuning range is 815 – 875 nm. Such instruments are of practical interest for optical coherence tomography, spectroscopy, optical metrology, and other application areas. (lasers)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Single-shot magnon interference in a magnon-superconducting-resonator hybrid circuit

Magnon interference is a hallmark of coherent magnon interactions. In this work, we demonstrate single-shot magnon interference using up to four magnon pulses in two remotely coupled yttrium iron garnet spheres mediated by a coplanar superconducting resonator. By exciting one YIG sphere with injected microwave pulses, we achieve coherent energy exchange between the two spheres, facilitating their interference processes, including Rabi-like oscillation with a single pulse, constructive and destructive interference with two pulses, and interference peak sharpening with up to four pulses—analogous to diffraction grating in optical interference. The resulting interference patterns can be precisely controlled by changing the frequency detuning and time delay of the magnon pulses. The demonstration of time-domain coherent control of remote magnon interference opens new pathways for advancing coherent information processing through multi-operation, circuit-integrated hybrid magnonic networks.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Rigid-body motion extracted from total motion of a flexible body

Control system eliminates or reduces flexibility effects on the manual and automatic control of large flexible vehicles. It extracts rigid-body and flexible-body motion and adapts well when a flexible-body frequency coincides or nearly coincides with the control mode frequency.

Howard, J. C.↗

Coupling between TOUGH3 and FLAC3D

Sandia National Laboratories has hired Itasca Consulting Group, Inc., the authors of the FLAC3D geomechanics software, to couple FLAC3D with TOUGH3, the porous media flow solver. The work is being done to enable a coupled mechanical-thermal-hydraulic analysis of a potential criticality event in a dual purpose cannister (DPC). The U.S. Department of Energy Office of Spent Fuel and Waste Science & Technology is investigating the performance of DPCs for direct geological disposal of spent nuclear fuel. Post closure criticality control is an important aspect of this investigation. Over geological timescales, it is envisioned that the canister and canister overpack will develop fractures due to stress corrosion processes. A breach in the canister could allow groundwater to fill the canister. Fresh water is a neutron moderator; thus, if the canister internals and fuel assemblies have been sufficiently degraded, a criticality event could occur. Such an event would release enough energy to boil the water between the fuel rods and pressurize the cannister. This internal pressurization may cause the initial fractures in the canister and overpack to grow. It is important to understand the change in hydraulic transmissivity between the canister and surroundings for two reasons: first, because it may control the potential for and frequency of subsequent criticality events; second, because it will control the release of radionuclides from the canister. The motivation for this work is to better understand the potential for periodic criticality events, cannister damage, and release of radionuclides during a criticality event in a DPC.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Demonstration of the frequency offset errors introduced by an incorrect setting of the Zeeman/magnetic field adjustment on the cesium beam frequency standard

The fine frequency setting of a cesium beam frequency standard is accomplished by adjusting the C field control with the appropriate Zeeman frequency applied to the harmonic generator. A novice operator in the field, even when using the correct Zeeman frequency input, may mistakenly set the C field to any one of seven major Beam I peaks (fingers) represented by the Ramsey curve. This can result in frequency offset errors of as much as 2.5 parts in ten to the tenth. The effects of maladjustment are demonstrated and suggestions are discussed on how to avoid the subtle traps associated with C field adjustments.

Kaufmann, D. C.↗

Effect of air flow, panel curvature, and internal pressurization on field-incidence transmission loss

In the context of sound transmission through aircraft fuselage panels, equations for the field-incidence transmission loss (TL) of a single-walled panel are derived that include the effects of external air flow, panel curvature, and internal fuselage pressurization. Flow is shown to provide a modest increase in TL that is uniform with frequency up to the critical frequency. The increase is about 2 dB at Mach number M = 0.5, and about 3.5 dB at M = 1. Above the critical frequency where TL is damping controlled, the increase can be slightly larger at certain frequencies. Curvature is found to stiffen the panel, thereby increasing the TL at low frequencies, but also to introduce a dip at the 'ring frequency' of a full cylinder having the same radius as the panel. Pressurization appears to produce a slight decrease in TL throughout the frequency range, and also slightly shifts the dips at the critical frequency and at the ring frequency.

Koval, L. R.↗

Simcenter TestLab Error in uploading reference profiles

Our team exports data from Matlab to a Simcenter TestLab formatted .mat file. The .mat file is then uploaded as a reference profile for Environmental Random Control vibration testing. Operations are applied to the data before export that introduce floating point errors. We are experiencing errors uploading the generated reference profiles if the frequency values have a certain level of floating point error (1 Hz vs 1.000000000000001 Hz). I generated some test cases of reference profiles that were giving us trouble, and outlined the errors we were seeing. Two different errors, depending on how the control frequency range is defined. Error is fixed by copy/pasting the frequency column in the Profile Editor.

97 MATHEMATICS AND COMPUTING↗

Bulk Grid Frequency Support Using Electrolyzers

Increasing renewable penetration in the bulk power systems has resulted in declining inertial response of the generation during system disturbances. This results in larger frequency deviations and oscillations during such events. This paper proposes a strategy for controlled dispatch of electrolyzers as loads to improve the system’s frequency response. A droop based controller with constraints based on electrolyzer operating limits has been developed to regulate its load. Consecutively, a localized frequency based control strategy has been developed to support the bulk system during disturbances. The impact of the electrolyzer support has been demonstrated using the 23-bus SAVNW system, and the 240-bus WECC system for baseline, 25% and 50% renewable penetration. The impact of changing droop settings and the available controllable electrolyzer capacities on the system’s frequency response has also been presented. Overall, the dispatchable electrolyzers helps improve (reduce) both the maximum frequency deviation and the settling times during common disturbances like loss of load/generation, and line faults. Systems with lower inertia were seen to benefit more from the controlled electrolyzer dispatch.

39 EE - Hydrogen and Fuel Cell Technologies (EE-3F↗

Frequency domain stability criteria. i.

Frequency domain stability of loop containing single nonlinearity, using Liapunov theory to give frequency domain stability criteria

FEEDBACK CONTROL SYSTEM↗

Robustness of continuous-time adaptive control algorithms in the presence of unmodeled dynamics

This paper examines the robustness properties of existing adaptive control algorithms to unmodeled plant high-frequency dynamics and unmeasurable output disturbances. It is demonstrated that there exist two infinite-gain operators in the nonlinear dynamic system which determines the time-evolution of output and parameter errors. The pragmatic implications of the existence of such infinite-gain operators is that: (1) sinusoidal reference inputs at specific frequencies and/or (2) sinusoidal output disturbances at any frequency (including dc), can cause the loop gain to increase without bound, thereby exciting the unmodeled high-frequency dynamics, and yielding an unstable control system. Hence, it is concluded that existing adaptive control algorithms as they are presented in the literature referenced in this paper, cannot be used with confidence in practical designs where the plant contains unmodeled dynamics because instability is likely to result. Further understanding is required to ascertain how the currently implemented adaptive systems differ from the theoretical systems studied here and how further theoretical development can improve the robustness of adaptive controllers.

Rohrs, C. E.↗

Extended H2 synthesis for multiple degree-of-freedom controllers

H2 synthesis techniques are developed for a general multiple-input-multiple-output (MIMO) system subject to both stochastic and deterministic disturbances. The H2 synthesis is extended by incorporation of anticipated disturbances power-spectral-density information into the controller-design process, as well as by frequency weightings of generalized coordinates and control inputs. The methodology is applied to a simple single-input-multiple-output (SIMO) problem, analogous to the type of vibration isolation problem anticipated in microgravity research experiments.

Hampton, R. David↗

Parametric Comparative Analysis between Virtual Synchronous Generator and Droop-based Inertia for Inverter-Based Microgrids

This paper presents a parametric comparative analysis between the virtual synchronous generator (VSG) method and the droop control method to emulate inertia in the voltage-source inverter (VSI). Droop controllers are commonly used to regulate sharing power in microgrids and distribute power generation proportionally among VSI’s depending on their rated power. Additionally, VSG has been used to regulate the Rate-of-Change-of-Frequency (RoCoF) of the microgrid using virtual inertia. Although both methods can be used to regulate the frequency variation, the influence of each method on the closed loop eigenvalues is not the same. In this work, the transient response of the frequency is analyzed for each method to determine their advantages and disadvantages regarding frequency regulation in microgrid applications. The results were verified by conducting experimental trials using VSI’s. These experiments demonstrated that VSG is more suitable for regulating RoCoF and frequency nadir than droop controllers since it provides inertial support and improves frequency response.

Campo-Ossa, Daniel D.↗

Optimal Control Design using an H(sub 2) Method for the Glovebox Integrated Microgravity Isolation Technology (G-Limit)

The acceleration environment on the International Space Station (ISS) will likely exceed the requirements of many micro-gravity experiments. The Glovebox Integrated Microgravity Isolation Technology (g-LIMIT) is being built by the NASA Marshall Space Flight Center to attenuate the nominal acceleration environment and provide some isolation for microgravity science experiments. G-LIMIT uses Lorentz (voice-coil) magnetic actuators to isolate a platform for mounting science payloads from the nominal acceleration environment. The system utilizes payload acceleration, relative position, and relative orientation measurements in a feedback controller to accomplish the vibration isolation task. The controller provides current commands to six magnetic actuators, producing the required experiment isolation from the ISS acceleration environment. This paper presents the development of a candidate control law to meet the acceleration attenuation requirements for the g-LIMIT experiment platform. The controller design is developed using linear optimal control techniques for frequency-weighted H(sub 2) norms. Comparison of the performance and robustness to plant uncertainty for this control design approach is included in the discussion.

Calhoun, Philip C.↗

Deformation and Flexibility Equations for Idealized ARIS Umbilicals, Under Planar End-Loading Conditions

The International Space Station (ISS) relies on the Active Rack Isolation System (ARIS) as the central component of an integrated, station-wide strategy to isolate microgravity space-science experiments. ARIS uses electromechanical actuators to isolate an International Standard Payload Rack (ISPR) from disturbances due to the motion of the ISS. Disturbances to microgravity experiments on ARIS-isolated racks are primarily transmitted via the ARTS power and vacuum umbilicals. Recent experimental tests indicate that these umbilicals resonate at frequencies outside the ARIS controller's bandwidth, at levels of potential concern for certain microgravity experiments. Reduction in the umbilical resonant frequencies could help to address this issue. This report develops equations for the in-plane deflections and flexibilities of an idealized umbilical (thin, flexible, cantilever beam) under end-point, in-plane loading (inclined-force and moment). The effect of gravity is neglected due to the on-orbit application. The analysis assumes an initially straight, cantilevered umbilical with uniform cross-section, which undergoes large deflections with no plastic deformation, such that the umbilical terminus remains in a single quadrant and the umbilical slope changes monotonically. The analysis is applicable to the ARIS power and vacuum umbilicals, under the indicated assumptions.

Hampton, R. David↗