Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Flow Conditions”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 883 records · Page 49

Experimental Validation of a High-Temperature Test Facility for Future Additive Manufactured Supercritical Carbon Dioxide Turbine Testing

For next-generation power plants to achieve high cycle efficiencies consistent with the Department of Energy's 65% efficiency target, turbomachinery capable of operating within high-temperature power cycles must be demonstrated. Pairing additively manufactured superalloy turbines with the supercritical carbon dioxide (sCO 2 ) power cycle could enable turbine inlet temperatures approaching 1300 °C while providing flexibility in turbine cooling strategies. Development of test facilities to characterize and validate such systems is crucial. In this study, a turbine test facility capable of achieving inlet conditions of 800 °C, 11 MPa, and 0.43 kg/s while accommodating complex auxiliary cooling flow requirements has been designed and constructed to support future testing of a Haynes 282 additively manufactured 30 kW turbine-generator system with advanced cooling channels. This facility enables characterization of aerodynamic performance, leakage, and windage losses. Details of the facility's construction and operation are presented, along with experimental validation tests using an orifice as an expansion device in place of the turbine. These tests confirm that the facility can reach the required conditions, distinguish regions of achievable steady and pseudo-steady conditions, and identify the heater power required for each point in the upcoming turbine campaign. The campaign confirmed that ISO 5167-2 can reliably predict orifice mass flow rates in extreme supercritical carbon dioxide conditions with deviations of 0.5–7.5%.

42 ENGINEERING↗

Modeling Efforts to Gain Insight into Historical Leak Events from the Single-Shell Tank A-105 in the Hanford 241-A Tank Farm - 20113

The 241-A Tank Farm is a single-shell tank (SST) farm constructed to store process waste from Hanford nuclear operations. Millions of gallons of nuclear waste were stored in the 241-A Tank Farm SSTs and some of the SSTs leaked in the past. In addition, spills and pipeline leaks during transfers and storage and intentional discharges to cribs and trenches resulted in releasing waste to the ground. Tank liner leaks are referred to as 'leaks' and all other discharges to the soil are referred to as 'releases.' Liquid waste that could be removed by pumping has been removed from all of the SSTs to reduce the potential for future leaks. The most significant historical leak event in 241-A Tank Farm occurred in 1965 when tank A-105 experienced a pressurized steam event. This event resulted in damage to the inner steel liner flooring of A-105, which was separated from the sidewalls over part of its circumference and buckled up to 2.5 m, vertically. During this event up to 7,570 L of contaminated liquid may have leaked to the adjacent soil. This leak occurred under extreme temperature and pressure conditions. Modeling efforts to better understand the nature and extent of historical leaks from subsurface SSTs that were used to store highly radioactive, self-boiling liquid wastes at 241-A Tank Farm have recently been undertaken. These efforts have compiled the available historical information to support a preliminary non-isothermal, multiphase flow and chemical transport modeling effort to re-create the conditions under which the leaks occurred and to formulate a conceptual model as to the extent and distribution of leaked radioactive contaminants in the adjacent soil material. The focus of this work was on developing an understanding of the key features, processes and bounding conditions related to tank A-105 leak events that occurred in the 1960's. The activities include estimation of leak composition, non-isothermal multiphase flow and transport modeling, and geochemical modeling. The STOMP{sup C} Water-Air-Energy modeling code was utilized to implement the three-dimensional representation of the subsurface tank and the surrounding flow field. Once constructed, the model was used to evaluate the conceptual understanding of leaks originating from different parts of the tank under the elevated temperature boundary conditions that were imposed by surrounding tanks at the time of the historical leaks. The chemical evolution of the liquid waste was also evaluated as it leaked from the tank under transient pressure and temperature gradients. The results of the preliminary evaluation suggested the presence of a heat-pipe effect beneath tank A-105 in which water vapor at an elevated temperature is driven away from the base of the tank to a position where water vapor cools, condenses and is then drawn back toward the tank by the strong capillary attraction of the dry soil. A non-sorbing contaminant (Tc-99) was introduced into this flow field to better understand the potential distribution patterns of leaked contaminants that may have occurred during the historical leak events. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Groundwater and Surface Water Flow (GSFLOW) model files to explore bedrock circulation depth and porosity in Copper Creek, Colorado

This data package contains integrated hydrological model input and output files for Copper Creek, Colorado (24 km2), a tributary of the East River located in the headwaters of the Upper Colorado River Basin. The model code is the U.S. Geological Survey (USGS) Groundwater and Surface Water Flow (GSFLOW) model. The model contains a 100-m grid resolution and a daily timestep. The land surface model is dynamically linked to a three-dimensional groundwater flow model that allows for streamflow gaining and losing conditions. The groundwater model contains 12 model layers and extends 400 m below land surface. The original Copper Creek model was modified to contain geologic layers representing saprolite, shallow bedrock, and deep bedrock. Endmember depth versus hydraulic conductivity relationships and porosity values for fractured crystalline rock are simulated. For the shallow case, median flow depths occur in the shallow saprolite at depths <8 m, while the deep case promotes a median groundwater flow depth of 100 m. With this modeling framework we compare streamflow response to a plausible worst-case drought lasting up to five years. Streamflow metrics of analysis include average streamflow, fraction of stream network that is dry, no-flow duration, average groundwater flow to streams and time to recovery following the drought. Results and implications are presented in a paper submitted to Geophysical Research Letters titled, "The role of bedrock circulation depth and porosity in mountain streamflow response to prolonged drought" by Rosemary WH. Carroll, Andrew H. Manning and Kenneth H Williams. A Readme.txt file provides instructions on how to download all model files and execute each model scenario. In addition to the GSFLOW output/prms/copper_drought.csv file containing daily basin water stores and fluxes (refer to GSFLOW manual) and the output/prms/copper_drought_statvar.dat file with output defined in the gsflow3.control file (refer to GSFLOW Manual), output files also include spatially distributed daily values of total evapotranspiration, canopy evaporation, precipitation, snowfall, infiltration, snow water equivalent, potential evapotranspiration, recharge, sublimation, soil moisture, contributing interflow, water table elevations, changes in groundwater storage, groundwater evapotranspiration, interbasin groundwater flow (limited to the alluvium below the stream outlet), and surface-groundwater exchanges within the river system.

54 ENVIRONMENTAL SCIENCES↗

High Fidelity Simulations of a Methane-Oxygen Rotating Detonation Rocket Engine

The rotating detonation combustor (RDC) is an important realization of pressure gain combustion for practical applications. The RDC system is characterized by a highly unsteady flow field, with multiple reflected pressure waves following the strong detonations and the existence of partially-burnt gases entrained within the detonation annulus during the injector recovery process. While experimental efforts have provided macroscopic properties of an RDC with a given fuel-oxidizer mixture and geometry, limited optical access and reduced lifespan of flow-field diagnostic equipment constrain understanding of the mechanisms that lend to wave stability, controllability, and sustainability. To this end, high-fidelity numerical simulations of the Air Force Research Laboratory (AFRL) methane-oxygen rotating detonation rocket engine (RDRE) are performed to provide detailed insight into the detonation physics and anomalous behavior within the combustor. The results highlight the merit of high-fidelity numerical studies in analyzing the combustion processes and injector dynamics of a complex combustion system. The simulations capture the general wave behavior observed within the experimental studies. Three different operating conditions, with varying global equivalence ratio and system mass flow rate, are considered: (1) baseline configuration, (2) high equivalence ratio, and (3) high mass flow rate. The high mass flow rate case results in increased detonation wave strength whereas the high equivalence ratio results in increased deflagrative heat release. The high equivalence ratio case results in chaotic behavior with two pairs of counter-rotating detonation waves, whereas a single pair of co-rotating waves is observed in the baseline and high mass flow rate cases. Further, parasitic combustion of the reactant mixture ahead of the detonation wave diminishes its strength and reduces propagation speed to approximately 50-60\% of the Chapman-Jouguet (CJ) condition. In this work, a detailed analysis of the detonation wave behavior, injector dynamics, and the statistics of combustion parameters are presented.

Prakash, Supraj↗

Conservative solute transport processes and associated transient storage mechanisms: Comparing streams with contrasting channel morphologies, land use and land cover

Abstract Land use within a watershed impacts stream channel morphology and hydrology and, therefore, in‐stream solute transport processes and associated transient storage mechanisms. This study evaluated transport processes in two contrasting stream sites where channel morphology was influenced by the surrounding land use, land cover, climate and geologic controls: Como Creek, CO, a relatively undisturbed, high gradient, forested stream with a gravel bed and complex channel morphology, and Clear Creek, IA, an incised, low‐gradient stream with low‐permeability substrate draining an agricultural landscape. We performed conservative stream tracer injections at these sites to address the following questions: (1) How does solute transport vary between streams with differing morphologies? and (2) How does solute transport at each stream site change as a function of discharge? We analysed in‐stream tracer time series data and compared results quantifying solute attenuation in surface and subsurface transient storage zones. Significant trends were observed in these metrics with varying discharge conditions at the forested site but not at the agricultural site. There was a broad range of transport mechanisms and evidence of substantial exchange with both surface and hyporheic transient storage in the relatively undisturbed, forested stream. Changing discharge conditions activated or deactivated different solute transport mechanisms in the forested site and greatly impacted advective travel time. Conversely in the simplified agricultural stream, there was a narrow range of solute transport behaviour across flows and predominantly surface transient storage at all measured discharge conditions. These results demonstrate how channel simplification inhibits available solute transport mechanisms across varying discharge conditions.

54 ENVIRONMENTAL SCIENCES↗

Numerical Investigation of Wall-Cooling Effect on Aero-Optical Distortions for Hypersonic Boundary Layer

Compressible wall-modeled large-eddy simulations of Mach 8 turbulent boundary-layer flows over a flat plate were carried out for the conditions of the hypersonic wind tunnel at Sandia National Laboratories. The simulations provide new insight into the effect of wall cooling on the aero-optical path distortions for hypersonic turbulent boundary-layer flows. Four different wall-to-recovery temperature ratios, 0.3, 0.48, 0.71, and 0.89, are considered. Despite the much lower grid resolution, the mean velocity, temperature, and resolved Reynolds stress profiles from the simulation for a temperature ratio of 0.48 are in good agreement with those from a reference direct numerical simulation. The normalized root-mean-square optical path difference obtained from the present simulations is compared with that from reference direct numerical simulations, Sandia experiments, as well as predictions obtained with a semi-analytical model by Notre Dame University. Here the present analysis focuses on the effect of wall cooling on the wall-normal density correlations, on key underlying assumptions of the aforementioned model such as the strong Reynolds analogy, and on the elevation angle effect on the optical path difference. Wall cooling is found to increase the velocity fluctuations and decrease the density fluctuations, resulting in an overall reduction of the normalized optical path distortion. Compared to the simulations, the basic strong Reynolds analogy overpredicts the temperature fluctuations for cooled walls. Also different from the strong Reynolds analogy, the velocity and temperature fluctuations are not perfectly anticorrelated. Finally, as the wall temperature is raised, the density correlation length, away from the wall but inside the boundary layer, increases significantly for beam paths tilted in the downstream direction.

42 ENGINEERING↗

Ultracentral Collisions of Small and Deformed Systems at RHIC

We study a range of collision systems involving deformed ions and compare the elliptic and triangular flow harmonics produced in a hydrodynamics scenario versus a color glass condensate (CGC) scenario. For the hydrodynamics scenario, we generate initial conditions using TRENTO and work within a linear response approximation to obtain the final flow harmonics. For the CGC scenario, we use the explicit calculation of two-gluon correlations taken in the high-p T “(semi)dilute-(semi)dilute” regime to express the flow harmonics in terms of the density profile of the collision. Here, we consider ultracentral collisions of deformed ions as a testbed for these comparisons because the difference between tip-on-tip and side-on-side collisions modifies the multiplicity dependence in both scenarios, even at zero impact parameter. We find significant qualitative differences in the multiplicity dependence obtained in the initial conditions+hydrodynamics scenario and the CGC scenario, allowing these collisions of deformed ions to be used as a powerful discriminator between models. We also find that sub-nucleonic fluctuations have a systematic effect on the elliptic and triangular flow harmonics which are most discriminating in 0–1% ultracentral symmetric collisions of small deformed ions and in 0–10% d197Au collisions. The collision systems we consider are 238 U 238 U, d 197 Au, 9 Be 197 Au, 9 Be 9 Be, 3 He 3 He, and 3 He 197 Au.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Flow maldistribution in plate heat exchangers – Impact, analysis, and solutions

Plate heat exchangers are commonly used in various industrial applications, such as refrigeration, air conditioning, heat pumps, powerplants, and chemical industries. Plate heat exchangers are well known for their superior heat transfer performance, compactness, and low refrigerant charge. Despite offering several advantages, they suffer from flow maldistribution issues. The flow maldistribution can deteriorate both the heat transfer and pressure drop performance, ultimately resulting in a lower system efficiency where plate heat exchangers are deployed. The flow maldistribution issues become more pronounced when the heat exchanger size is relatively large and the number of plates is higher, limiting the deployment of plate heat exchangers in larger industrial systems. Consequently, analyzing and understanding the flow maldistribution behavior in plate heat exchangers and finding ways to mitigate flow maldistribution related issues become essential topics of interest. Further, this review aims to address the effect of flow maldistribution on plate heat exchanger characteristics. First, the experimental and numerical works on flow maldistribution under single-phase and two-phase conditions are detailed. Subsequently, the end-channel and end-plate effects are discussed. Then, the methods to mitigate flow maldistribution in plate heat exchangers are outlined. Finally, based on a thorough literature survey and industrial requirements, future research directions are recommended.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Force Balance Model Assessment for Mechanistic Prediction of Sliding Bubble Velocity in Vertical Subcooled Boiling Flow

The bubble sliding after departing from nucleation site is frequently observed in flow boiling systems and, the crucial impact on wall heat transfer has been evidenced through many experiments. As a result, the heat transfer modeling associated with sliding bubble has become one of the subjects of great attention in CFD boiling heat transfer community. The modeling efforts are primarily aimed at improving the existing Heat Flux Partitioning (HFP) model via the implementation of sliding bubble-induced heat transfer. The performance of HFP model depends inherently on the fidelity of sub-models used to predict the fundamental bubble parameters (e.g., bubble departure/lift-off diameter). In the same context, the accurate prediction of sliding bubble parameters (e.g., sliding bubble growth, sliding bubble velocity) is essential to achieving the successful heat transfer modeling associated with sliding bubble. Of many sliding bubble parameters, this paper deals with the sliding bubble velocity. Specifically, the force balance model was assessed in view of the sliding bubble velocity prediction. The parametric effect of key sub-models (e.g., drag force, bubble growth models) used in the force balance equation was investigated. The experimental data from Maity (2000) and Yoo et al. (2016) were used for demonstrating the model predictive performance. It was found that the force balance model proposed in this study was able to predict well the bubble sliding velocity based on the accurate prediction of bubble growth during sliding. The predictive performance was proven with the experimental data measured under various subcooled boiling conditions of both water and refrigerant (NOVEC-7000) flowing upward in vertical channels.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Aerosol Particle Deposition on a Spent Nuclear Fuel Assembly Spacer Grid

The flow and particle deposition patterns on surfaces in an idealized spacer grid for a 17x17 pressurized water reactor (PWR) assembly in a spent fuel canister are modeled using computational fluid dynamics (CFD) with laminar flow. The effects of gravitational settling, non-Stokesian flow, and particle slip are first rigorously analyzed. From the analysis, non-Stokesian effects and slip may be neglected for the particle sizes and conditions expected in a canister. For particles that do not settle out, a swirling flow pattern at the corners of a spacer grid channel directs particles to the leeward side of the flow vanes where much of the deposition occurs. Particle deposition increases with increasing particle diameter. Deposition also increases with decreasing flow velocity as this provides more time for particles to settle and deposit on the leeward side of the flow vanes. The fraction of particles that are transmitted through a spacer grid is determined as a function of inlet gas velocity and particle diameter by running the CFD calculation for each set of conditions and for each particle diameter. Curve fits of the transmission curve as a function of particle diameter for a specified spacer grid and flow velocity are applied to a lognormal particle mass density function for the inlet particles. The resulting mass density function and aerosol mass fraction that passes through the spacer grid can be determined analytically without resorting to numerical iteration. A sample calculation of the analytical solution is demonstrated for a lognormal particle mass density function.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Variational encoder geostatistical analysis (VEGAS) with an application to large scale riverine bathymetry

Estimation of riverbed profiles, also known as bathymetry, plays a vital role in many applications, such as safe and efficient inland navigation, prediction of bank erosion, land subsidence, and flood risk management. The high cost and complex logistics of direct bathymetry surveys, i.e, depth imaging, have encouraged the use of indirect measurements such as surface flow velocities. However, estimating high-resolution bathymetry from indirect measurements is an inverse problem that can be computationally challenging. Here, we propose a reduced-order model (ROM) based approach that utilizes a variational autoencoder (VAE), a type of deep neural network with a narrow layer in the middle, to compress bathymetry and flow velocity information and accelerate bathymetry inverse problems from flow velocity measurements. In our application, the shallow-water equations (SWE) with appropriate boundary conditions (BCs), e.g., the discharge and/or the free surface elevation, constitute the forward problem, to predict flow velocity. Then, ROMs of the SWEs are constructed on a nonlinear manifold of low dimensionality through a variational encoder and the bathymetry inversion problem is derived on the low-dimensional latent space in a Hierarchical Bayesian setting. Further, the reformulation allows variational inference with a small number (e.g., $\mathscr{O}$ (100) of ROM runs and efficient uncertainty quantification. We have tested our inversion approach on a one-mile reach of the Savannah River, GA, USA. Once the neural network is trained (offline stage), the proposed technique can perform the inversion operation orders of magnitude faster than traditional inversion methods that are commonly based on linear projections, such as principal component analysis (PCA), or the principal component geostatistical approach (PCGA). Furthermore, tests show that the algorithm can estimate the bathymetry with good accuracy even with sparse flow velocity measurements.

54 ENVIRONMENTAL SCIENCES↗

Pool boiling on metal-foam enhanced tube bundle: heat transfer characteristics and flow visualization

A flooded evaporator configuration is common in large central air conditioning or process cooling systems. It is basically a shell and tube heat exchanger, in which a secondary fluid (brine or water) circulates inside the tube bundle and is cooled by the vaporization of the refrigerant on the outside surface of the tubes. The enhanced pool boiling process enables the compact design of flooded evaporators, which substantially reduces the refrigerant charge. High-porosity metal foam, with a large surface-area-to-volume ratio, could provide an extended heat transfer area and a high-density of nucleation sites. This study experimentally investigated the pool boiling heat transfer and flow characteristics on metal-foam enhanced tube bundles. The enhanced bundle consists of four aluminum tubes with aluminum foam brazed around the outer surface, which are horizontally mounted in a staggered arrangement. The results showed that the metal-foam enhanced tube bundles improved the heat transfer coefficient by 100-160% with a lower wall temperature difference of 1-10°C, compared to the baseline. In addition, the tube pitch played a significant role in determining the pool boiling behavior of the tube bundles.

Yang, Cheng-Min↗

Iodine’s Wild Ride Leading to Photoinstability in Halide Perovskite Solar Cells

Understanding processes that contribute to efficiency losses during long-term operation of perovskite solar cells is crucial for achieving operational stability. Although maximum power point tracking optimizes outdoor performance, it is not uncommon that devices are kept under open-circuit conditions during sunny hours. Under these conditions, charge carriers accumulate at the interfaces rather than flowing through the circuit. In the case of the MAPbI 3 /spiro-OMeTAD interface studied here, hole accumulation leads to formation of I2 and subsequent oxidation of spiro-OMeTAD. By employing in situ absorption measurements, we show that the decrease in power conversion efficiency follows the spiro-OMeTAD oxidation while operating the device under open-circuit conditions. In short-circuit conditions, where photogenerated charge carriers are extracted in the external circuit, the I 2 -induced oxidation of spiro-OMeTAD and the device instability are minimized. The photoinduced expulsion of iodine from MAPbI 3 into spiro-OMeTAD discussed in this work provides new insight into the photoinstability of perovskite solar cells.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Accuracy of HVAC Load Predictions: Validation of EnergyPlus and DOE-2 using FLEXLAB Measurements

The aim of the project reported here was to better understand the level of accuracy of three building energy simulation (BES) engines (‘engines’) — EnergyPlus™, DOE-2.1e, and DOE-2.2 — by identifying and investigating significant deviations between the performance predicted by these engines and actual performance as measured in the FLEXLAB® test facility at Lawrence Berkeley National Laboratory (LBNL). The specific test conditions included some of those prescribed in ANSI/ASHRAE Standard 140 - Standard Method of Test for the Evaluation of Building Energy Analysis Computer Programs. Detailed measurements of FLEXLAB performance, including indoor temperatures and heat fluxes and air-flow and water flow rates and temperatures in the Heating, Ventilating and Air Conditioning (HVAC) system, together with hourly weather data, were recorded and used in analyzing the simulation results from EnergyPlus v8.8, DOE-2.2 v3.65 and DOE-2.1e v127. These engines are commonly used in the United States for building energy code compliance, federal, state, and utility incentives programs, as well as energy efficient design of new buildings and energy retrofit of existing buildings. Seven conventional overhead mixing ventilation scenarios were tested and each engine was found to have a similar level of agreement with the measurements of space-level heating and sensible cooling loads. These results provide useful information regarding the accuracy of these engines in predicting the cooling and heating load elements of whole building energy performance. This information is intended for practitioners who are concerned about transitioning between simulation tools with different engines and for managers of utility programs leveraging these tools for evaluating and/or projecting measure savings to be incentivized under their programs. The results of the comparisons of simulated and measured performance indicate that the predictions from all three engines are not significantly different. The 24-hour average value of the absolute mean bias indicates the likely magnitude of the error in any particular case. The average mean bias is reduced by cancelation of overprediction in one case by underprediction in another. The daytime absolute mean biases, which may be more important for both energy performance and occupant comfort, are ~6%, presumably because of the greater complexity involved in simulating in the presence of solar radiation. EnergyPlus typically overpredicts the cooling load and/or underpredicts the heating load by ~1.5% and the DOE-2 engines typically underpredict the cooling load by approximately the same amount. The Root Mean Square Error is relatively more sensitive to shorter term variations in the difference between predicted and measured loads; the three engines have similar values, ~10%, suggesting that the uncertainties in their predictions of peak loads may also be similar in magnitude. The implication of these results is that users, both designers and program analysts, can use EnergyPlus, DOE-2.1e, or DOE-2.2 to model conventional commercial buildings equipped with overhead mixing ventilation with a similar level of confidence. Further work is required to better understand the variability in the level of agreement between the engine predictions and FLEXLAB measurements, where a particular engine will agree well with FLEXLAB in some cases and not so well in others and another engine will agree or disagree in different cases. As the sources of this variability are identified and eliminated or reduced significantly, it is recommended that the experimental capabilities and methods developed in the study reported here should be applied to validating heating and cooling load calculations for spaces with different types of furniture and miscellaneous loads. These methods should then be applied to low energy space conditioning systems in EnergyPlus including, in particular, radiant slab and radiant ceiling panel cooling and heating systems and ‘mixed mode’ systems that combine mechanical cooling and natural ventilation systems, focusing on controls, including control of thermal mass. The work reported here addresses the conventional method of heating and cooling occupied spaces; other methods, such as the use of radiant heating and cooling systems have the potential to provide equivalent occupant comfort, or better, with lower energy consumption. These systems are addressed more explicitly in EnergyPlus but there is a need for empirical validation to give users the same level of confidence in modeling these systems that they have, or should have, in modeling conventional systems, based on the results presented here.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Lost Circulation Materials in Geothermal Drilling: Thermal Degradation, Viscosity, Compression, and Flow Loop Tests

This dataset provides a set of experimental data on the performance of lost circulation materials (LCMs) used in geothermal drilling operations. It includes results from four distinct tests: thermal degradation, viscosity measurements, compression tests, and high-temperature flow loop experiments. The materials tested, such as cedar fiber, cotton seed hulls, magma fiber, microcellulose, and sawdust, were analyzed under a range of conditions to assess their effectiveness in mitigating fluid losses in geothermal wells. Data on thermal degradation explores mass loss, water loss, and gas release for each material when subjected to temperatures between 90C and 250C. Viscosity measurements capture the behavior of LCM mixtures under different temperatures, while compression tests investigate the structural integrity of both undegraded and thermally degraded materials. The high-temperature flow loop experiments simulate geothermal well conditions, analyzing how different materials and mixtures affect fluid flow and sealing performance in a fractured reservoir environment. In addition to the experimental data, the dataset includes photos documenting the materials, schematics of test setups, and several published manuscripts that provide detailed insights into the experimental methods and findings.

15 GEOTHERMAL ENERGY↗

Aerodynamic Analysis of Wind Loading on Parabolic Trough Collectors Using High-Fidelity CFD Modeling

Wind loading on parabolic solar collector support structures is the key driver for material costs. As identified by NREL's CSP Best Practices project [1], ability to predict wind-loading in deep-arrays and the impact of edge effects has potential to decrease levelized cost of electricity (LCoE) by 15%. In this study, we present a high-fidelity computational model that can model the flow around deep arrays of parabolic troughs under varying turbulent inflow conditions. Ability to accurately reproduce atmospheric boundary layer (ABL) profiles is first demonstrated through Large Eddy Simulation (LES) simulations and compared against wind tunnel measurements. Thereafter, unsteady turbulent flow past single row and six row configurations is computed using hybrid RANS/LES simulations. Investigations of wind loading, through parametric tilt angle variations of single row and on waked collectors in six-row configuration, are used to highlight design considerations for parabolic troughs only possible through high-fidelity unsteady calculations.

aerodynamics↗

$c$-functions in flows across dimensions

We explore the notion of c-functions in renormalization group flows between theories in different spacetime dimensions. We discuss functions connecting central charges of the UV and IR fixed point theories on the one hand, and functions which are monotonic along the flow on the other. First, using the geometric properties of the holographic dual RG flows across dimensions and the constraints from the null energy condition, we construct a monotonic holographic c-function and thereby establish a holographic c-theorem across dimensions. Second, we use entanglement entropies for two different types of entangling regions in a field theory along the RG flow across dimensions to construct candidate c-functions which satisfy one of the two criteria but not both. In due process we also discuss an interesting connection between corner contributions to the entanglement entropy and the topology of the compact internal space. As concrete examples for both approaches, we holographically study twisted compactifications of 4d N =4 SYM and compactifications of 6d N = (2, 0) theories.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Controlling product selectivity in hybrid gas/liquid reactors using gas conditions, voltage, and temperature

For the conversion of CO 2 into fuels and chemical feedstocks, hybrid gas/liquid-fed electrochemical flow reactors provide advantages in selectivity and production rates over traditional liquid phase reactors. However, fundamental questions remain about how to optimize conditions to produce desired products. Here, using an alkaline electrolyte to suppress hydrogen formation and a gas diffusion electrode catalyst composed of copper nanoparticles on carbon nanospikes, we investigate how hydrocarbon product selectivity in the CO 2 reduction reaction in hybrid reactors depends on three experimentally controllable parameters: (1) supply of dry or humidified CO 2 gas, (2) applied potential, and (3) electrolyte temperature. Changing from dry to humidified CO 2 dramatically alters product selectivity from C 2 products ethanol and acetic acid to ethylene and C 1 products formic acid and methane. Water vapor evidently influences product selectivity of reactions that occur on the gas-facing side of the catalyst by adding a source of protons that alters reaction pathways and intermediates.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗