Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Fire”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 883 records · Page 49

Desensitizing ignition of energetic materials when exposed to accidental fire

Composite energetic materials combine fuel and oxidizers for high energy density exothermic reactions and are used for ordnance, industrial and localized power generation applications. This study focuses on examining an additive to a mixture of aluminum (Al) and copper oxide (CuO) to decrease ignition sensitivity under accidental fire exposure conditions. Ammonium nitrate (AN) was incorporated into Al+CuO, as a 1:1 replacement for CuO, for varied equivalence ratios and examined for ignition and combustion when exposed to slow and fast heating rate ignition conditions. The goal was to develop an Al+CuO+AN formulation that would perform comparable to Al+CuO when intentionally ignited, but would not ignite in an accidental fire. Experimental results show that Al+CuO+AN with an equivalence ratio (ER) ranging from 4.0–5.5 inerts the reactants when exposed to slow heating conditions, yet ignites with comparative combustion performance to the baseline Al+CuO mixture when exposed to fast heating conditions. These results are consistent with thermochemical simulations of the heat of combustion and adiabatic flame temperature for the respective reactions. In conclusion, this study presents a new approach for tailoring composite energetic materials toward accidental fire safety by exploiting the early stage decomposition kinetics of AN, which are activated only by slow heating ignition conditions.

36 MATERIALS SCIENCE↗

Land-use history, fire regime, and large-mammal herbivory affect deer-preferred plant diversity in longleaf pine woodlands

Since ecological systems often experience multiple disturbances, understanding changes in important ecological interactions, such as plant-herbivore interactions, may require studies capable of disentangling the unique and interactive effects of multiple forms of disturbance. For example, understanding how mammalian herbivores affect plant communities may require understanding how widespread past disturbances, such as agricultural land use, interact with contemporary disturbances, such as prescribed fire. Here, we tested if past agricultural land use and contemporary fire regime modified the effects of mammalian herbivory on focal plant communities by measuring the richness of plant species preferred by deer at 26 longleaf pine woodlands containing paired open and large-mammal exclusion plots. Land-use history significantly affected the community composition of deer-preferred species, and focal species were 8.19 times more likely to be present in post-agricultural sites than non-agricultural sites. Large-mammal herbivory only affected plant species richness in woodlands with low fire frequencies wherein focal species were on average 2.23 times more likely to be present in exclusion plots than open plots. These results suggest that past and present disturbances can mediate contemporary plant-animal interactions and may explain spatial patterns in the intensity of large-mammal herbivory. Our findings also suggest that common management practices, such as use of prescribed burns, may indirectly promote plant species richness by reducing deer herbivory.

60 APPLIED LIFE SCIENCES↗

Three Western Pacific Typhoons Strengthened Fire Weather in the Recent Northwest U.S. Conflagration

Abstract Strong winds that accentuated a fire outbreak in the western United States in early September of 2020 resulted from an atmospheric wave train that spanned the Pacific Ocean. Days before the atmospheric waves developed in the United States, three western Pacific tropical cyclones (typhoons) underwent an extratropical transition over Korea within an unprecedentedly short span of 12 days. Using a climate diagnostic approach and historical forecast data, it was found that the amplitude of the atmospheric waves accompanying the western U.S. fire weather would not have been so profound if not for the influence of these typhoons. Together, the recurving typhoons provided a significant source of wave activity flux directed toward North America – amplifying the ridge over the U.S. west coast while deepening the trough in central Canada. This anomalous circulation produced the severe frontal system that caused extreme winds in western Oregon, Washington and California – rapidly spreading fire.

58 GEOSCIENCES↗

Quantifying chaotic dynamics from integrate-and-fire processes

Characterizing chaotic dynamics from integrate-and-fire (IF) interspike intervals (ISIs) is relatively easy performed at high firing rates. When the firing rate is low, a correct estimation of Lyapunov exponents (LEs) describing dynamical features of complex oscillations reflected in the IF ISI sequences becomes more complicated. In this work we discuss peculiarities and limitations of quantifying chaotic dynamics from IF point processes. We consider main factors leading to underestimated LEs and demonstrate a way of improving numerical determining of LEs from IF ISI sequences. We show that estimations of the two largest LEs can be performed using around 400 mean periods of chaotic oscillations in the regime of phase-coherent chaos. Application to real data is discussed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Downscaled CMIP5 projections of physical fire risk understate historical trends

Reliable projections of wildfire risk are important for multi-sector impacts analysis. Statistically downscaled and bias-corrected Earth system model ensemble products are routinely used to analyze regional physical wildfire risk, but evaluations of historical observed trends and variability are lacking. Here, we evaluate physical fire risk over the western United States using the Canadian Forest Fire Weather Index (FWI) by comparing model outputs from the Coupled Model Intercomparison Project Phase 5 (CMIP5), statistically downscaled via the Multivariate Adaptive Constructed Analogs (MACA) approach, against the observational target dataset gridMET, a gridded high-resolution surface meteorological product. We analyze multidecadal trends and interannual variability in seasonal average FWI for the historical period and future projections under two emissions scenarios, and we compare MACA-CMIP5 ensemble results with a simple time series model that generates historical and future projections of seasonal FWI based on bootstrapping observed historical trends and variability. Our findings indicate that MACA-CMIP5 accurately captures the magnitude and spatial patterns of seasonally averaged FWI but tends to underestimate historical decadal trends. We show that future increases in fire risk may be underestimated relative to the simple time series model that projects historical variability into the future. We also highlight that model biases in relative humidity contribute significantly to model-data differences. Our results underscore the importance of historical hindcasting exercises for informing broader multi-sector applications.

FWI↗

Climate Dynamics Preceding Summer Forest Fires in California and the Extreme Case of 2018

Recent record-breaking wildfire seasons in California prompt an investigation into the climate patterns that typically precede anomalous summer burned forest area. Using burned-area data from the U.S. Forest Service’s Monitoring Trends in Burn Severity (MTBS) product and climate data from the fifth major global reanalysis produced by the European Centre for Medium-Range Weather Forecasts (ERA5) over 1984–2018, relationships between the interannual variability of antecedent climate anomalies and July California burned area are spatially and temporally characterized. Lag correlations show that antecedent high vapor pressure deficit (VPD), high temperatures, frequent extreme high temperature days, low precipitation, high subsidence, high geopotential height, low soil moisture, and low snowpack and snowmelt anomalies all correlate significantly with July California burned area as far back as the January before the fire season. Seasonal regression maps indicate that a global midlatitude atmospheric wave train in late winter is associated with anomalous July California burned area. July 2018, a year with especially high burned area, was to some extent consistent with the general patterns revealed by the regressions: low winter precipitation and high spring VPD preceded the extreme burned area. However, geopotential height anomaly patterns were distinct from those in the regressions. Extreme July heat likely contributed to the extent of the fires ignited that month, even though extreme July temperatures do not historically significantly correlate with July burned area. While the 2018 antecedent climate conditions were typical of a high-burned-area year, they were not extreme, demonstrating the likely limits of statistical prediction of extreme fire seasons and the need for individual case studies of extreme years.

54 ENVIRONMENTAL SCIENCES↗

Schneider Springs Fire Study 2023 for Ecosystem Respiration Rates: Surface Water Chemistry and Hydrologic Sensor Data across the Yakima River Basin, Washington, USA (v2)

This dataset supports a broader study examining the drivers of spatial variability in wildfire impacts across the Yakima River Basin. Data provided within this dataset were generated from sample collection across 17 total sites (8 sites affected by a recent wildfire, 9 sites unaffected by a recent wildfire) within multiple rivers throughout the Yakima River Basin in Washington, USA from May-July 2023. Fire affected sites are defined as those affected by the 2021 Schneider Springs Fire, based on the drainage area of the streams being within the 2021 Schneider Springs Fire burn perimeter or not (Figure 1, below). The contents include surface water geochemistry data (dissolved organic carbon; total dissolved nitrogen; total suspended solids); short-term sonde data (specific conductivity; turbidity; pH; chlorophyll A; temperature); stream depth data; stream velocity; manual chamber open channel respiration data; sensor time-series data (oxygen; water pressure; barometric pressure); field metadata (including qualitative information on in stream and river corridor characteristics); and environmental context photos taken in the field. The dataset also includes a summary file of the sensor data and plots of the sensor data. Sensors were only recovered at 15 out of the 17 sites, and not all sensors were recovered at all 15 sites (see Methods section for more details), therefore all data does not exist at all sites. Data from a 2022 study at the same sites, as well as additional sites, can be found at https://data.ess-dive.lbl.gov/view/doi:10.15485/1969566. The data package was originally published in November 2023. It was updated in June 2025 (v2; modified files). See the change history section in the readme for more details. For details on how to navigate data packages generated by this project, see https://data.ess-dive.lbl.gov/portals/PNNLRiverCorridorSFA/About. This dataset is comprised of one folder with field photos and one main data folder with two subfolders. The main data folder consists of (1) file-level metadata; (2) data dictionary; (3) field metadata; (4) field protocol; (5) readme; (6) international generic sample number (IGSN) mapping file; and (7) stream depth and averages. The sensor data subfolder consists of (1) sensor installation methods summary; (2) stream velocity; and (3) six subfolders. The BarotrollAtm (barometric pressure; temperature), DepthHOBO (water pressure; temperature), MantaRiver (specific conductivity; turbidity; pH; chlorophyll A; temperature), EXO (specific conductivity; pH; temperature), miniDOT (dissolved oxygen; temperature), and miniDOTManualChamber (dissolved oxygen; temperature) contain time-series data, plots, and summary files. The sample data subfolder consists of (1) total suspended solids (TSS) data; (2) dissolved organic carbon (DOC, measured as non-purgeable organic carbon, NPOC) data and averages; (3) total dissolved nitrogen (TN) data and averages; and (4) methods codes. All files are .csv, .pdf, .jpg, .jpeg, or .mov.

54 ENVIRONMENTAL SCIENCES↗

Literature Review on the Effects of Prescription Fire on theEcology of Site 300

Lawrence Livermore National Laboratory has historically conducted prescription burns across approximately 2,000 acres of Site 300 on an annual basis to safeguard test facilities and operations from the risk of wildfire encroachment. Prescription burns began in 1960, and although fire frequency varies among the designated burn areas, all have been burned at least once. A patchwork of native perennial grassland communities and associated special-status plant and animal populations occur onsite in many areas that have been receiving these treatments. Because the size and locations of prescription burns may shift in coming years, an evaluation is warranted to determine how these shifts may affect listed biota, including rare plants, and the distinct ecological conditions present on the site. This report presents the results of a literature review conducted by ICF International (ICF) to collect basic information on native perennial grasslands in California, the influence of fire on these grasslands, and management tools for restoring and maintaining them. The objective of this study was to review the scientific literature on California native grasslands and summarize the current state of knowledge pertaining to the possible effects -- both beneficial and detrimental -- of prescribed fire on the ecology of Site 300. The results of this review are intended to inform future management practices that may be carried out at Site 300 to maintain the plant and wildlife communities and to ensure that the ecological conditions benefit the special-status species that inhabit the Site. This review is also intended to identify a study approach to investigate changes over the next 10 years in the burned areas and in areas where burning will be discontinued.

54 ENVIRONMENTAL SCIENCES↗

Coal Fired Power Plant Configuration and Operation Impact on Plant Effluent Contaminants and Conditions

The primary objective of this project is to characterize coal contaminants in coal-fired power plant wastewater as a function of coal type, unit configurations, and unit operation profile with uncertainty analysis. This project was in response to the U.S. Department of Energy (DOE) Solicitation DE-FOA-0001842. The project duration was between September 01, 2018, and December 31, 2021 (no-cost extension filed, due to the Covid-19 pandemic restrictions, and approved). Field and lab test program was conducted with the main goal to characterize coal contaminants in coal-fired power plant wastewater as a function of coal type, unit configurations, and unit operation profile with uncertainty analysis. In this project, the team of Lehigh University (prime recipient) and Western Kentucky University identified two suitable Thermoelectric Power Plants (TTPs) firing bituminous and sub-bituminous coals respectively, designed test plans, and performed sample collection. Sampling included coal from each TTPs power generation units, Wet Flue Gas Desulfurization (WFGD) slurry material and waste-water samples taken from the outlet of the water treatment tank prior to discharge and other pertinent locations. Coal samples are dried, crushed, and pulverized according to the American Society for Testing and Materials (ASTM) methods. The prepared coal samples are analyzed for normal proximate and ultimate analysis tests in addition to the toxic metals and anions according to ASTM methods. The FGD slurry materials are analyzed for toxic metals and anions according to Electric Power Research Institute (EPRI) or Environmental Protection Agency (EPA) methods, as appropriate. The wastewater samples from the water treatment tank outlet are analyzed for toxic metals and anions according to EPA methods. The effluent species analyzed include mercury, arsenic, selenium, nitrate/nitrite, bromide, and chlorine. This project provided results of effluent conditions as a function of coal type, unit configuration, and unit operation profile, and identified the levels of uncertainty in the effluent results.

01 COAL, LIGNITE, AND PEAT↗

Energy Improvements of Fire Station 71

Since 2018, the City of Shawnee, Kansas has completed two phases of the State of Kansas Facility Conservation Improvement Program (FCIP), an initiative that guarantees operational cost and energy savings through targeted construction improvements on City facilities and infrastructure. The City is currently in the third phase of this FCIP, where one of the projects included an investment in energy improvements for Fire Station 71 (FS 71). The City partnered with Navitas, an Energy Service Company (ESCO), to implement a Photovoltaic Solar Array on FS71. The purpose of this project was to invest in sustainable building improvements with Energy Conservation Measures (ECM) to bring cost savings to the City and to provide sustainable benefits to the residents of Shawnee. In the first task of the project, Navitas collaborated with the City of Shawnee and the Community Development Department to determine the optimal layout and schedule for the installation of the solar array on FS 71. In the second task of the project, Navitas installed the 99.8 kW DC Photovoltaic solar array system. This system installation comprised of racking, inverters, optimizers, load center, and disconnect, which were all installed at a total ECM price of $\$$247,948. The third task focused on start-up and commissioning of the array. Navitas installed a real-time data analytics information management system integrated with utility meters, which evaluates the operations of the utility system and verifies operation of equipment and ensures optimum operation for energy efficiency. In the final task of this project, this analytics system was used for monitoring and verification, which will continue to be used to evaluate the success of the project for the coming years. The primary goal of the project was to install the 99.8 kW DC PV solar array at FS 71 to demonstrate the viability of solar energy systems in essential municipal facilities. Fire stations are energy demanding structures, as they require a constant intake of power and have a high baseline energy usage. The success of solar arrays on a fire station exemplifies their energy efficiency and effectiveness and displays their potential for application on other city facilities. By installing a solar array at such a facility, the City sought not only to offset electricity usage but also to serve as a model for ECMs in other municipal facilities and infrastructure projects. From an economic standpoint, this project demonstrates the feasibility of renewable energy at the municipal level. The total project cost of $\$$247,948 was split evenly between city funds and award funding, minimizing financial risk while ensuring guaranteed long-term savings. Any excess savings that are beyond the guaranteed minimums remain with the city, which enables future investment in sustainable energy initiatives. This project provides many benefits to the public. In addition to reducing the environmental footprint of city operations, it lowers taxpayer-funded utility spending and improves the energy security of a critical facility. The knowledge gained from this implementation motivates the City to focus on similar efforts across other public facilities in future FCIP phases and other City projects.

14 SOLAR ENERGY↗

Validation and uncertainty quantification of Fuego simulations of calorimeter heating in a wind-driven hydrocarbon pool fire.

The objective of this work is to perform an uncertainty quantification (UQ) and model validation analysis of simulations of tests in the cross-wind test facility (XTF) at Sandia National Laboratories. In these tests, a calorimeter was subjected to a fire and the thermal response was measured via thermocouples. The UQ and validation analysis pertains to the experimental and predicted thermal response of the calorimeter. The calculations were performed using Sierra/Fuego/Syrinx/Calore, an Advanced Simulation and Computing (ASC) code capable of predicting object thermal response to a fire environment. Based on the validation results at eight diversely representative TC locations on the calorimeter the predicted calorimeter temperatures effectively bound the experimental temperatures. This post-validates Sandia's first integrated use of fire modeling with thermal response modeling and associated uncertainty estimates in an abnormal-thermal QMU analysis.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Rapid Shifts in Soil Nutrients and Decomposition Enzyme Activity in Early Succession Following Forest Fire

In post-disturbance landscapes nutrient availability has proven a major control on ecological succession. In this study, we examined variation in connections between soil nutrient availability and decomposition extracellular enzyme activity (EEA) across post fire secondary succession in forest soils as well as after a secondary flood disturbance. We also examined possible linkages between edaphic properties and bacterial communities based on 16S rRNA gene analysis. We found that with advancing succession in a post-fire landscape, the relationship between soil nutrients and EEA became stronger over time. In general, late successional soils showed stronger connections between EEA and soil nutrient status, while early successional soils were marked by a complete decoupling of nutrients and EEA. We also found that soil moisture and bacterial communities of post-fire disturbance soils were susceptible to change following the secondary flood disturbance, while undisturbed, reference forest soils were not. Our results demonstrate that nutrient pools correlating with EEA change over time. While past work has largely focused on ecosystem succession on decadal timescales, our work suggests that nutrients shift in their relative importance as a control of decomposition EEA in the earliest stages of secondary succession. Furthermore, this work emphasizes the relevance of successional stage, even on short timescales, in predicting rates of carbon and nitrogen cycling, especially as disturbances become more frequent in a rapidly changing world.

54 ENVIRONMENTAL SCIENCES↗

STABILITY TESTS OF MONOPROPELLANTS EXPOSED TO FLAMES AND RIFLE FIRE

Tests of the stability of several monopropellants under the effects of impact and heat were conducted in order to assess the potential hazard in a propellant storage area from major fires and enemy attack. Hydrazine, hydrazine nitrate solution, n-propyl nitrate, and ethylene oxide were all tested in one-gallon aluminum containers (half of them filled to 25% and half to 95% capacity) by being subjected to oil bonfires and wood bonfires, and 20-mm incendiary, 20mm high explosive incendiary, and .30-caliber rifle fire. Aviation gasoline was tested in the same manner, for comparison. In the bonfire tests, all four monopropellants generally gave explosion intensities equivalent to one another regardless of the type of bonfire (oil or wood) or the amount of liquid in the test container. Occasionally, however, with hydrazine, hydrazine nitrate solution, and n-propyl nitrate, anomalous results occurred: there was either (a) no explosion or (b) an explosion of above average intensity. Ethylene oxide more nearly approximated the behavior of aviation gasoline than did the other monopropellants. In the rifle-fire tests, n-propyl nitrate appeared to be most shock- sensitive since it was exploded by all three types of ammunition. Hydrazine and hydrazine nitrate solution were exploded by the high-explosive ammunition, but not by the incendiary or .30-dber ammunition. Ethylene oxide was not exploded by any of the gunfire, but the liquid was ignited by both incendiary and high-explosive incendiary ammunition.

FIRING↗

Display Developer for Firing Room Applications

The firing room at Kennedy Space Center (KSC) is responsible for all NASA human spaceflight launch operations, therefore it is vital that all displays within the firing room be properly tested, up-to-date, and user-friendly during a launch. The Ground Main Propulsion System (GMPS) requires a number of remote displays for Vehicle Integration and Launch (VIL) Operations at KSC. My project is to develop remote displays for the GMPS using the Display Services and Framework (DSF) editor. These remote displays will be based on model images provided by GMPS through PowerPoint. Using the DSF editor, the PowerPoint images can be recreated with active buttons associated with the correct Compact Unique Identifiers (CUIs). These displays will be documented in the Software Requirements and Design Specifications (SRDS) at the 90% GMPS Design Review. In the future, these remote displays will be available for other developers to improve, edit, or add on to so that the display may be incorporated into the firing room to be used for launches.

Firing Room Application↗

A New Application to Facilitate Post-Fire Recovery and Rehabilitation in Savanna Ecosystems

The U.S. government spends an estimated $3billion per year to fight forest fires in the United States. Post-fire rehabilitation activities represent a small but essential portion of that total. The Rehabilitation Capability Convergence for Ecosystem Recovery (RECOVER) system is currently under development for Savanna ecosystems in the western U.S. The prototype of this system has been built and will have realworld testing during the summer 2013 fire season. When fully deployed, the RECOVER system will provide the emergency rehabilitation teams with critical and timely information for management decisions regarding stabilization and rehabilitation strategies.

post-fire↗

Ecosystem Carbon Emissions from 2015 Forest Fires in Interior Alaska

In the summer of 2015, hundreds of wildfires burned across the state of Alaska, and consumed more than 1.6 million ha of boreal forest and wetlands in the Yukon-Koyukuk region. Mapping of 113 large wildfires using Landsat satellite images from before and after 2015 indicated that nearly 60% of this area was burned at moderate-to-high severity levels. Field measurements near the town of Tanana on the Yukon River were carried out in July of 2017 in both unburned and 2015 burned forested areas (nearly adjacent to one-another) to visually verify locations of different Landsat burn severity classes (low, moderate, or high). Results: Field measurements indicated that the loss of surface organic layers in boreal ecosystem fires is a major factor determining post-fire soil temperature changes, depth of thawing, and carbon losses from the mineral topsoil layer. Measurements in forest sites showed that soil temperature profiles to 30 cm depth at burned forest sites increased by an average of 8o - 10o C compared to unburned forest sites. Sampling and laboratory analysis indicated a 65% reduction in soil carbon content and a 58% reduction in soil nitrogen content in severely burned sample sites compared to soil mineral samples from nearby unburned spruce forests. Conclusions: Combined with nearly unprecedented forest areas severely burned in the Interior region of Alaska in 2015, total ecosystem fire emission of carbon to the atmosphere exceeded most previous estimates for the state.

Ecosystem↗

Model Development of Large-Scale Spacecraft Fires During the Saffire-IV Experiments

An accidental fire can pose dire consequences to crew safety and mission success. The Saffire Project aims to investigate large-scale fire behavior in microgravity in order to aid in the prediction of spacecraft fires. These series of experiments ignite solid materials within the Northrup Grumman Cygnus vehicle after it departs from a resupply mission to the International Space Station. A model of the Cygnus vehicle during the Saffire-IV experiment was developed using the commercial software PyroSim. The cargo arranged during the descent phase was used for the geometry of the model. In the model, cabin air flows into the Saffire payload while heat and combustion species flow out of the Saffire downstream through a standoff to a bed of sensors called the Far Field Diagnostic (FFD). The temperature sensors near the Saffire payload were used to determine the heat release rate at the outlet of Saffire, while the details of the combustion and stoichiometry are used to determine the species flow at the outlet. Gas measurements previously reported for the Saffire-IV experiments are compared against the simulation results and sources of error are discussed.

Modeling↗

Nevada Wildland Fires: Mapping Historical Burned Areas and Identifying Drivers of Fuel Load Growth to Inform Desert Tortoise Habitat Management in Southern Nevada

Wildfire frequency and intensity in the Mojave desert are increasing, driven by invasive grasses that outcompete native vegetation not well-adapted to wildfire. These grasses, primarily cheatgrass (Bromus tectorum) and red brome (Bromus rubens), and the wildfires that occur when the grasses ignite, are a serious threat to the critically endangered Mojave desert tortoise (Gopherus agassizii). Declining Mojave desert tortoise populations are of great concern to project partners, the Bureau of Land Management Southern Nevada District Office, the US Forest Service’s Rocky Mountain Research Station, and the US Department of Agriculture Agricultural Research Service’s Arid Lands Ecology Lab, who currently lack the resources for fire recovery studies essential for informed fire and invasive grass management. To address this gap, the team utilized NASA Earth observations including Aqua Moderate Resolution Imaging Spectroradiometer (MODIS), Terra MODIS, Landsat 5 Thematic Mapper (TM), and Landsat 8 Operational Land Imager (OLI), to analyze trends in burned areas over the past 20 years through historic burn maps and to examine fuel load growth drivers, with a focus on invasive vegetation. These historical burn maps revealed a pattern of precipitation anomalies that strongly correlate with higher Normalized Difference Vegetation Index (NDVI) values. Years with significant precipitation and NDVI spikes led to greater fuel load in the dry season and larger burns. Additionally, El Niño years correlated significantly with precipitation anomalies which may provide our partners with insights into burn trends and enable better allocation of fuel load treatment practices. However, while identifying drivers of fuel load growth proved feasible, a lack of in situ data hindered attempts to analyze pre-fire growth of invasive grasses compared with native grasses. Despite this limitation, the project demonstrated the feasibility of using Earth observations for wildfire and habitat management, ultimately benefiting conservation efforts for the Mojave desert tortoise.

fuel load↗