Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “FLOW RATE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 883 records · Page 49

Utah FORGE: Injection and Production Test results and Reports from August 2024

This dataset includes results and reports from the injection/production test for wells 16A(78)-32 and 16B(78)-32 in August, 2024 at Utah FORGE. Materials include injection, post stimulation production, flow rate, gamma, temperature and pressure survey results. For the respective wells, injection and production profile results and interpretations are provided in .xlsx and .las file formats. Additionally, for both wells, preliminary and final reports are included and provide logging procedures and visualizations of the results.

15 GEOTHERMAL ENERGY↗

Nucleation of soot: experimental assessment of the role of polycyclic aromatic hydrocarbon (PAH) dimers

The irreversible dimerization of polycyclic aromatic hydrocarbons (PAHs) – typically pyrene (C 16 H 10 ) dimerization – is widely used in combustion chemistry models to describe the soot particle inception step. This study concerns itself with the detection and identification of dimers of flame-synthesized PAH radicals and closed-shell molecules and an experimental assessment of the role of these PAH dimers for the nucleation of soot. To this end, flame-generated species were extracted from an inverse co-flow flame of ethylene at atmospheric pressure and immediately diluted with excess nitrogen before the mixture was analyzed using flame-sampling tandem mass spectrometry with collision-induced fragmentation. Signal at m/z = 404.157 (C 32 H 20 ) and m/z = 452.157 (C 36 H 20 ) were detected and identified as dimers of closed-shell C 16 H 10 and C 18 H 10 monomers, respectively. A complex between a C 13 H 9 radical and a C 24 H 12 closed-shell PAH was observed at m/z = 465.164 (C 37 H 21 ). However, a rigorous analysis of the flame-sampled mass spectra as a function of the dilution ratio, defined as the ratio of the flow rates of the diluent nitrogen to the sampled gases, indicates that the observed dimers are not flame-born, but are produced in the sampling line. In agreement with theoretical considerations, this paper provides experimental evidence that pyrene dimers cannot be a key intermediate in particle inception at elevated flame temperatures.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

High flux boiling heat transfer enhancement using triangle shaped vertical walls in two-phase microchannel heat exchangers

Two-phase heat exchangers allow heat loads to be dissipated with lower fluid flow rates without inducing thermal gradients, and high surface area microchannels further reduce the thermal resistance of these heat exchangers. However, there are many practical limits that prevent widespread use of two-phase microchannel heat exchangers. Many authors have looked to address these practical limits by treating the channel floors or creating artificial nucleation sites. Few works look to enhance heat transfer in the walls of channels with hydraulic diameters below 200 μm. This work is aimed at increasing the efficacy of high aspect ratio silicon microchannels that use R134a as the working fluid. The 125 parallel channels are 40 μm wide, 200 μm deep, and 2 mm long and contain a 15 μm wide, 150 μm long restriction at each inlet. The thermal resistance and dryout characteristics of traditional, plain-walled channels are compared to channels with 2 area enhancement patterns each of which increases the area available for heat transfer by 41%. Furthermore, a resistance to dryout is seen in both area-enhanced test sections, and a 15.5% reduction in thermal resistance is shown for the area-enhanced part with a 6 μm triangular pitch. Only a 7.8% performance increase is seen in the test section with a 3 μm pitch. Both area enhancement patterns induce an average 27% increase in pressure drop for all tests. Heat transfer characteristics are solved for using a finite element analysis (FEA) model. By examining heat transfer coefficients and local heat fluxes, it is postulated that the area enhancement reduces heat transfer coefficients and the performance increase is caused by increasing the number of active nucleation sites.

42 ENGINEERING↗

Accuracy of HVAC Load Predictions: Validation of EnergyPlus and DOE-2 using FLEXLAB Measurements

The aim of the project reported here was to better understand the level of accuracy of three building energy simulation (BES) engines (‘engines’) — EnergyPlus™, DOE-2.1e, and DOE-2.2 — by identifying and investigating significant deviations between the performance predicted by these engines and actual performance as measured in the FLEXLAB® test facility at Lawrence Berkeley National Laboratory (LBNL). The specific test conditions included some of those prescribed in ANSI/ASHRAE Standard 140 - Standard Method of Test for the Evaluation of Building Energy Analysis Computer Programs. Detailed measurements of FLEXLAB performance, including indoor temperatures and heat fluxes and air-flow and water flow rates and temperatures in the Heating, Ventilating and Air Conditioning (HVAC) system, together with hourly weather data, were recorded and used in analyzing the simulation results from EnergyPlus v8.8, DOE-2.2 v3.65 and DOE-2.1e v127. These engines are commonly used in the United States for building energy code compliance, federal, state, and utility incentives programs, as well as energy efficient design of new buildings and energy retrofit of existing buildings. Seven conventional overhead mixing ventilation scenarios were tested and each engine was found to have a similar level of agreement with the measurements of space-level heating and sensible cooling loads. These results provide useful information regarding the accuracy of these engines in predicting the cooling and heating load elements of whole building energy performance. This information is intended for practitioners who are concerned about transitioning between simulation tools with different engines and for managers of utility programs leveraging these tools for evaluating and/or projecting measure savings to be incentivized under their programs. The results of the comparisons of simulated and measured performance indicate that the predictions from all three engines are not significantly different. The 24-hour average value of the absolute mean bias indicates the likely magnitude of the error in any particular case. The average mean bias is reduced by cancelation of overprediction in one case by underprediction in another. The daytime absolute mean biases, which may be more important for both energy performance and occupant comfort, are ~6%, presumably because of the greater complexity involved in simulating in the presence of solar radiation. EnergyPlus typically overpredicts the cooling load and/or underpredicts the heating load by ~1.5% and the DOE-2 engines typically underpredict the cooling load by approximately the same amount. The Root Mean Square Error is relatively more sensitive to shorter term variations in the difference between predicted and measured loads; the three engines have similar values, ~10%, suggesting that the uncertainties in their predictions of peak loads may also be similar in magnitude. The implication of these results is that users, both designers and program analysts, can use EnergyPlus, DOE-2.1e, or DOE-2.2 to model conventional commercial buildings equipped with overhead mixing ventilation with a similar level of confidence. Further work is required to better understand the variability in the level of agreement between the engine predictions and FLEXLAB measurements, where a particular engine will agree well with FLEXLAB in some cases and not so well in others and another engine will agree or disagree in different cases. As the sources of this variability are identified and eliminated or reduced significantly, it is recommended that the experimental capabilities and methods developed in the study reported here should be applied to validating heating and cooling load calculations for spaces with different types of furniture and miscellaneous loads. These methods should then be applied to low energy space conditioning systems in EnergyPlus including, in particular, radiant slab and radiant ceiling panel cooling and heating systems and ‘mixed mode’ systems that combine mechanical cooling and natural ventilation systems, focusing on controls, including control of thermal mass. The work reported here addresses the conventional method of heating and cooling occupied spaces; other methods, such as the use of radiant heating and cooling systems have the potential to provide equivalent occupant comfort, or better, with lower energy consumption. These systems are addressed more explicitly in EnergyPlus but there is a need for empirical validation to give users the same level of confidence in modeling these systems that they have, or should have, in modeling conventional systems, based on the results presented here.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Pilot-Scale Evaluation of Natural Gas-Based Foam at Elevated Pressure and Temperature Conditions

Abstract Nitrogen (N2) and Carbon Dioxide (CO2) foams have been used as hydraulic fracturing fluids for several decades to reduce water usage and minimize damage in water-sensitive reservoirs. These foam treatments require gases to be liquefied and transported to site. An alternative approach would be to use natural gas (NG) that is readily available from nearby wells, pipelines, and processing facilities as the internal, gaseous phase to create a NG-based foam. Hydraulic fracturing with NG foam is a relatively inexpensive option, makes use of an abundant and often wasted resource, and may even provide production benefits in certain reservoirs. As part of an ongoing development project sponsored by the Department of Energy (DOE), the surface process to create NG foam is being developed and the properties of NG foam are being explored. This paper presents recent results from a rigorous pilot-scale demonstration of NG foam over a range of operating scenarios relevant to surface and bottomhole conditions with a variety of base-fluid mixtures. The Pilot-scale Foam Test Facility (PFTF) used in these investigations is first described. The PFTF is capable of generating foamed fluids at pressures up to 7,500 psig and at temperatures in excess of 300°F. Then, results from several investigations aimed at proving NG foam at conditions relevant to the field are presented. NG foam was characterized using rheology measurements and flow visualization techniques. Experiments were performed to investigate the texture and stability of NG foam generated by two different mixing methods: one using a custom designed tee to match mixing velocities in the field where the gas phase is jetted into the aqueous stream, and another to ensure comprehensive mixing for laboratory analysis. Parametric studies were conducted to explore the effects of flow rate, foam quality, and temperature on the stability of NG foam. Moreover, different fluid preparations were used to investigate the effect of base fluid and additive concentrations on the stability of NG foams. Additional laboratory studies that investigated foam stability with produced water and multicomponent NG mixtures are also reported. The NG foams explored in these investigations exhibited typical, shear-thinning behavior observed in rheological studies of N2- and CO2-based foams. The measured viscosity and observed stability indicate that NG foams are well suited for fracturing applications. Like other foams, NG foam exhibits sensitivity to operating temperature characterized by a decrease in apparent viscosity as temperature increases. Rapid foam breakdown was observed at significantly elevated temperatures exceeding 290°F. In addition to fluid characterization, these investigations also yielded several key lessons that should be applied to future field demonstrations of NG foam.

Beck, Griffin↗

Pore-Scale Oil Connectivity and Displacement by Controlled-Ionic-Composition Waterflooding Using Synchrotron X-Ray Microtomography

Controlled-ionic-composition waterflooding is an economic and effective method to improve oil recovery in carbonate oil reservoirs. Recent studies show controlling the salinity and ionic composition of injection water can alter the wettability of carbonate mineral surfaces. The pore-scale oil connectivity and displacement by controlled-ionic-composition waterflooding in heterogeneous carbonate reservoirs, especially at the early stage, is still unclear. The goal of this study is to examine the role of ion concentrations and types in the oil displacement efficiency and investigate the impact of the waterflooding on the pore-scale oil displacement using the national synchrotron facility. A carbonate rock sample was flooded with synthetic high-salinity water and other water solutions with different sulfate concentrations. The waterflooding processes were visualized with synchrotron X-ray microtomography to follow the evolution of pore-scale oil/brine interactions at typical field flow rates. Experimental results show that the water with lower sulfate concentration and higher salinity did not change the wettability of the pore surfaces. Higher sulfate ion concentrations in the water, in contrast, altered the wettability of carbonate pore surfaces from oil-wet to neutral-wet within the first few minutes of waterflooding. Finally, novel insight was gained on the ability of water with high-sulfate concentration to displace oil in the small pores and through abundant oil channels, which could consequently lead to higher oil recovery from the carbonate rock.

04 OIL SHALES AND TAR SANDS↗

Pressure Transient Analyses and Poroelastic Modeling of Hydraulic Fracture Dilation for Multiple Injections at the Devine Fracture Pilot Site

Our team has conducted electromagnetic (EM) surveys for the past six years to monitor hydraulic-fracture behavior at the Devine Fracture Pilot Site (DFPS). The sub-horizontal orientation of a shallow hydraulic fracture at the DFPS provides uniform access to the fracture area for interrogation and data collection. Ahmadian et al. (2023) suggested a possible correlation between spatiotemporal changes in the flow rate, bottomhole pressure (BHP), and the observed surface recorded electric field at the DFPS. In this paper, we present the development of poroelastic forward models and pressure transient analyses (PTAs) to support the development of a multiphysics inverse model for these EM surveys. First, we conducted PTAs of the shut-in periods after six injections out of 10 to determine the fracture closure pressure (FCP) or the overburden pressure used in a poroelastic fracture reopening model. Second, we developed a finite-element poroelastic model throughout five injection cycles to include the effect of the cumulative injected volumes due to the previous injections on current fracture dilation in the presence of highly permeable unpropped and propped zones adjacent to the cohesive layer that models fracture reopening. Fracture reopening in this poroelastic model is based on a calibrated traction-separation response using the bottomhole pressure collected in two injection campaigns in 2020 and 2022. We used the outcomes of a previous simulation study of the primary hydraulic-fracturing stimulation to define the dimension of an unpropped fracture zone ahead of the propped fracture area. The PTAs led to FCPs consistent with those obtained using the injection data collected at the DFPS in 2020. Further, these analyses showed that at later injections, the fracture closure occurred at a later time with respect to the shut-in time, inferring the effect of cumulative injected volumes in previous injections. The simulation results show that considering the propped and unpropped fracture zones improves our poroelastic model in predicting the injection-well BHP. The numerical simulation results demonstrate a significant excess pore pressure near the fracture because of the preceding formation loadings by the previous injections. The obtained fracture dilation area and fluid pressure distribution provide a basis to improve the development of a multiphysics inverse model. Furthermore, in an iteratively coupled scheme, this pressure distribution can be introduced into EM models to render a holistic view of the causative mechanisms for the surface signal anomalies.

02 PETROLEUM↗

Condensation Particle Counter (CPC) Instrument Handbook

The Model 3772 CPC is a compact, rugged, and full-featured instrument that detects airborne particles down to 10 nm in diameter, at an aerosol flow rate of 1.0 lpm, over a concentration range from 0 to 1x104 #/cc. This CPC is ideally suited for applications without high concentration measurements, such as basic aerosol research, filter and air-cleaner testing, particle counter calibrations, environmental monitoring, mobile aerosol studies, particle shedding and component testing, and atmospheric and climate studies.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Swept-Frequency Acoustic Interferometry (SFAI) and Related Technologies

Researchers at Los Alamos National Lab have developed acoustic technologies to accurately discern the characteristics of materials within closed containers non-invasively. SFAI and related technologies use high-frequency sound to characterize liquids, gasses, mixtures, emulsions, and other fluids inside pipes and containers. SFAI offers the potential to measure material characteristics and two-and three-phase flows within pipes including flow rates and water- and gas-volume fractions all with a small-footprint device. SFAI is an enabling component of a 2014 R&D 100 Award Winner.

36 MATERIALS SCIENCE↗

Nevada National Security Site - E-Tunnel Wastewater Disposal System: Fourth Quarter 2019

This report includes the results of monthly inspections and monitoring for October, November, and December 2019. Monthly inspections and monitoring were conducted on October 15, November 26, and December 18, 2019. Inspections include a visual assessment of the berms, ponding, water levels relative to the overflow pipes, tunneling or burrowing into the berms, soil conditions on and around the berms, erosion or sloughing of the slopes of the berms, seeps at the toe of the berms, deep-rooting botanicals on the berms, and fencing. Monthly monitoring includes measurements of the instantaneous flow rate, hydrogen ion activity (pH), and specific conductance of the E-Tunnel Wastewater Disposal System (ETDS) discharge. Annual sample results of the effluent water from the ETDS are also included in this report. The effluent sample was collected on September 11, 2019, and analyzed for the parameters listed in Table 1-B of Permit NEV 96021. In addition, Permit NEV 96021 requires the collection and analysis of representative groundwater samples from Well ER 12-1 every 24 months. This summary report provides the information pertaining to the sampling and analysis of groundwater samples collected on April 10, 2019.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Deep Direct-Use Geothermal Feasibility Study for Hawthorne NV

The Hawthorne Nevada, deep direct-use geothermal study is a two-year effort funded by the U.S. Department of Energy to determine the techno-economic feasibility of implementing a large-scale, direct-use facility for the Hawthorne Army Depot (HAD) and the public facilities of the city of Hawthorne and Mineral County. The approach links a production side analysis (PSA) and a demand side analysis (DSA) into a whole-system analysis (WSA) to provide an integrated assessment of the resource and the probability of delivering economically viable direct-use energy to Hawthorne. Hawthorne, Nevada is in the western part of the Basin and Range province and has been the focus of geothermal investigations for over 40 years. Over the last 15 years, several studies completed by the U.S. Navy Geothermal Program Office (GPO) in conjunction with industry professionals quantified the existence of several low temperature geothermal prospects, the most promising of which is called Prospect A. The promise of Prospect A is based on drilling and flow testing that produced ~100 °C water at flow rates of up to 31 l/s (500 gallons per minute). Measured productivity indexes range from 40-85 l/s/MPa, suggesting a warm and productive heat source. Despite the promise of the resource, uncertainties in its spatial extent and long-term sustainability mean that techno-economic analyses must include probabilities of the sustainability of the resource under different operating scenarios. Here, the PSA is conducted by integrating a wide range of disparate data to estimate lognormal P90, P50, and P10 resource capacities. These capacities are used as input to a thermal-hydrologic (T-H) model to estimate thermal drawdown for each capacity estimate for several different DSA scenarios. Using a systems-based approach, the WSA links the dynamic T-H simulations of the PSA/DSA combinations with the techno-economic model GEOPHIRES to account for both the temporal dynamics and uncertainties in the system to produce probabilistic distributions of several performance metrics including the levelized cost of heat (LCOH) and the return on investment (ROI). This report is the final delivery for the project and documents the study's activities and results.

15 GEOTHERMAL ENERGY↗

Nevada National Security Site E-Tunnel Wastewater Disposal System Quarterly Monitoring Report, Water Pollution Control Permit NEV 96021 (First Quarter Calendar Year 2020)

This report includes the results of monthly inspections and monitoring for January, February, and March 2020. Monthly inspections and monitoring were conducted on January 15, February 12, and March 17, 2020. Inspections include a visual assessment of the berms, ponding, water levels relative to the overflow pipes, tunneling or burrowing into the berms, soil conditions on and around the berms, erosion or sloughing of the slopes of the berms, seeps at the toe of the berms, deep-rooting botanicals on the berms, and fencing. Monthly monitoring includes measurements of the instantaneous flow rate, hydrogen ion activity (pH), and specific conductance of the E-Tunnel Wastewater Disposal System discharge.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Risk Assessment and Ventilation Modeling for Hydrogen Release in Vehicle Repair Garages

The availability of repair garage infrastructure for hydrogen fuel cell vehicles is becoming increasingly important for future industry growth. Ventilation requirements for hydrogen fuel cell vehicles can affect both retrofitted and purpose-built repair garages and the costs associated with these requirements can be significant. A hazard and operability study (HAZOP) was performed to identify key risk-significant scenarios related to hydrogen vehicles in a repair garage. Detailed simulations and modeling were performed using appropriate computational tools to estimate the location, behavior, and severity of hydrogen release based on key HAZOP scenarios. This work compares current fire code requirements to an alternate ventilation strategy to further reduce potentially hazardous conditions. Overall, the amount of flammable mass of hydrogen at any one time in the simulation is low compared to the total mass of hydrogen released, due to the low flow rate of a low pressure release. It is shown that position, direction, and velocity of ventilation have a significant impact on the amount of instantaneous flammable mass in the domain.

33 ADVANCED PROPULSION SYSTEMS↗

Design and Analysis of a Double Wall, Water Cooled Window for Accelerator Based Mo-99 Production

The electron accelerator based Mo-99 production technique requires the use of Rhodotrons to generate 38 MeV, 6.32 mA pulsed electron beams. The introduction of the pulsed beam structure has introduced fatigue concerns in the vacuum-helium windows that did not exist previously for electron beam production via linear accelerators. Previous analysis has shown that temperature fluctuations of approximately 100°C above and below the steady state operating temperature of ~500°C will occur within the windows. A water cooled window will eliminate this concern by reducing the primary mechanical stress due to the 300-psig helium pressure load as well as the secondary thermally induced stress. Although a water cooled window was considered years ago, the complexities of adding an additional water line was unattractive until now. A double wall, water cooled window has been designed and analyzed for this reason. The water cooled window design is shown to decrease the helium-side window temperature to as low as 125°C, while the vacuum-side window is maintained at 161°C at a water flow rate of 3.2 GPM. These low steady state temperatures reduce the thermal stress of the helium-side window significantly. Also, the primary mechanical stress has been reduced by roughly 50% due to the reduced pressure gradient across the helium-side window (150-psig water and 300-psig helium). Considering a Mo-99 production loss of roughly 1%, the water cooled window is a drastic improvement over the previous helium cooled designs and should be greatly considered for future upgrades and redesign.

43 PARTICLE ACCELERATORS↗

Improving AHU Performance by Minimizing Approach Temperature, Reducing Air Maldistribution, and Efficiently Handling Sensible and Latent Loads (Phase 1 Interim Final Technical Report)

Residential air handling units (AHUs) have stayed the same in form and efficiency for the past 30+ years, with incremental improvements made to address safety, functionality, and energy-efficiency. The purpose of this research in Phase I, Topic 9a: Next Generation Residential Air Handlers, was to improve AHU performance by minimizing heat exchanger (HX) approach temperature, reducing air maldistribution, and developing alternative system configurations which more efficiently handle sensible and latent loads. In this research Optimized Thermal Systems (OTS) developed, modeled, and evaluated multiple alternative system concepts. A dual vapor compression system separate sensible and latent cooling (SSLC) concept was studied to inform work on alternative concepts and to show best-case performance benefit. System concepts included ejector enhanced vapor compression cycles, desiccant assisted dehumidification, dual evaporator SSLC, and alternative AHU HX configurations. A dual vapor compression system showed COP improvement of 20%, however, required additional components, increased unit size, and increased cost. Two types of ejector enhanced vapor compression cycles with dual evaporators improved system COP by 9 to 11%, and reduced AHU losses by as much as 18%, with design changes limited to the AHU, no unit physical size increase, and a moderate increase to system first cost. Desiccant assisted air-conditioning required increased air flow rate resulting in higher fan power and the desiccant wheel increased sensible heat load leading to increased compressor power and reduced system COP. Dual evaporator cycles were found to degrade performance due to increased expansion losses. Optimized single slab HX designs used in place of the traditional A-coil HX led to 44–49% reduction in aluminum, 47–60% less refrigerant charge, and improved HX velocity distribution.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Evaluation of High Vacuum Pump for Tritium Service

In tritium process systems, vacuum pumps are typically used to evacuate volumes and piping, as well as transfer gas to other parts of the process. This was done using the combination of an all-metal scroll pump with a metal bellows backing pump. The all-metal scroll pump, manufactured by Normetex, has been unavailable since 2012, and efforts continue to find a suitable replacement. The main obstacle is finding a pump that has no oils or polymer components, which degrade when exposed to tritium and introduce corrosive and/or hazardous impurities into the process. Since turbomolecular pumps are used in tritium processing, it is thought that pumps similar to the turbomolecular pumps would be of interest. A newer model turbomolecular pump with a variable rotation speed has been identified for use in tritium processing. The turbomolecular pump, backed by a Metal Bellows MB-601 pump with the pump heads in series, was characterized for static and gas flow conditions to determine the suction pressure at various discharge pressures or flow rates for various gases.

42 ENGINEERING↗

Comparison of Extended and Accelerated VOG Tests

The reprocessing of used nuclear fuel would release volatile radionuclides into the off-gas streams of a processing plant, including ¹²⁹I. The dissolver off-gas and more dilute vessel off-gas streams (VOG) must both be targeted when mitigating ¹²⁹I environmental release because each contains some amount of iodine. Iodine-129 will likely be found as elemental iodine (I₂) and methyl iodide (CH₃I) in these off-gas streams. Reduced silver-exchanged mordenite (AgZ or Ag⁰Z) has been investigated as a potential sorbent for iodine abatement and is studied here under prototypic VOG conditions. Because of the relatively low iodine abundance and high flow rates of the VOG, total iodine concentrations are expected to be in the parts per billion range. Thus, VOG experiments need to run for extended durations at low concentrations to reach sorbent saturation. Because the sorbent will be exposed to oxidizing gas streams for extended periods of time, aging effects and sorbent degradation need to be considered when designing a sorbent-based abatement system. Three sets of experiments were performed with the aim of determining how the adsorption of iodine by AgZ is affected by differing test durations and gas compositions. The first tested the capacity of sorbent aged for 8 months under a humid air stream. The second tested differences in sorbent capacity and mass transfer zone (MTZ) length during high-concentration (1200 ppb v ) CH₃I loading in a humid nitrogen gas (N₂) stream and a humid air gas stream over 28 days. The third tested sorbent capacity and MTZ length during low concentration (< 200 ppb v ) CH₃I and I₂ loading in a humid air stream over 9 months. The results of these tests suggest that AgZ capacity drops by ~50% after 1 month of aging, by ~60% after 2 months of aging, and then does not continue to decrease significantly at up to 8 months of aging. One-month aging tests that compared N₂ and air as the gas stream diluent resulted in similar maximum loading capacities and overall loading curves, indicating that the effects of aging cannot be mitigated by avoiding air as the balance gas. The 9-month extended VOG tests did not result in clear sorbent saturation at the inlet, but it can be inferred using an assumption of a maximum capacity of 45 mg I/g AgZ. Applying this assumption, then the MTZ of CH₃I is 12.8 cm, and the MTZ of I₂ is 12.4 cm. These results are similar to previous tests. Comparisons to tests completed at Idaho National Laboratory suggest that the CH₃I MTZ may be dependent on concentration. Future work should re-evaluate the design of the VOG iodine capture system with this updated data and should seek to understand fundamental characteristics of CH₃I adsorption by AgZ, such as the effect of concentration, gas velocity, and gas composition.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Integrated Optimization and Control of a Hybrid Gas Turbine/sCO 2 Power System

During phase-I, the project team led by Echogen Power Systems (EPS) had two primary objectives based on investigating the application of gas turbines with supercritical carbon dioxide (sCO 2 ) power cycles. The first objective was to improve the overall efficiency and performance of a hybrid gas turbine/sCO 2 power system through a joint optimization of the two subsystems (gas turbine and sCO 2 power cycle) using non-linear optimization techniques that simultaneously evaluate thermal performance of the combined cycle. The hybrid power system included several points of interaction, including (but not limited to) gas turbine exhaust, fuel heating, inlet chilling and turbine cooling. The second objective was to establish a baseline transient response model of the hybrid power system and a notional microgrid and begin steps to integrate the control systems of the three major elements (gas turbine, sCO 2 cycle and grid controller). The project team established a baseline performance for a combined cycle power plant using a production gas turbine and scaled sCO 2 power cycle only utilizing exhaust heat recovery. Echogen’s non-linear techno-economic optimization code was extended by adding gas turbine component models derived from a in-house developed gas turbine design code. With the two cycles coupled by the gas turbine exhaust, design parameters of both cycles were allowed to vary simultaneously to determine performance opportunity versus isolated designs. Returning to the baseline gas turbine/sCO 2 power cycle transient models: Echogen had in-house developed sCO 2 cycle transient model in GT-Suite system simulation software, and had partnered with Siemens Finspång for gas turbine transient model, and Siemens PTI group to provide micro-grid load profile as well as hybrid power cycle generated load (power and frequency) analysis. The transient model for the SGT-750 Siemens gas turbine was a “black-box” functional mock-up interface (FMI) model developed by Siemens Industrial Turbomachinery in Finspång, Sweden. The SGT-750 is a twin-shaft gas turbine that produces 40 MW electricity with an efficiency of about 40% at ISO conditions. At 100% gas turbine throttle (load), the SGT-750 has average exhaust conditions of 114.6 kg/s and 469.8°C. The transient model for sCO 2 power cycle was developed by Echogen in GT-SUITE 1D system simulation software platform. The basic CO 2 flow circuit has single-shaft turbomachinery with net 11.5 MW electrical power output at design conditions. The power turbine has a double-ended shaft with one end connected to synchronous generator through a fixed-ratio gearbox. The other end of power turbine is connected to the compressor through a continuously variable transmission. The major components of the sCO 2 power cycle modeled include air cooled condenser/cooler, CO 2 compressor, recuperator, two waste heat exchanger coils, power turbine, continuous variable transmission, gearbox and generator. Integration of SGT-750 transient model and sCO 2 power cycle transient model was done in Matlab Simulink. In the integrated model, the gas turbine and sCO 2 power cycle interacted at two points, first one being the gas turbine exhaust gas flow rate and temperature, which were inputs to sCO 2 power cycle model. The second point was the distribution of micro-grid load demand signal between the SGT-750 generator and sCO 2 cycle generator. For a given combined-cycle load demand, the gas turbine load demand was equal to the total demand minus the sCO 2 cycle power generated. In the present study the integrated model was simulated for two cases of grid load demand: (i) for a step change, both positive-step and negative-step, in grid load demand (ii) for a micro-grid load demand curve provided by Siemens PTI group. Finally, the time series plots representing load demand versus integrated system response were presented including the sCO 2 power cycle control system performance plots. The actual generated power and frequency of both the generators, gas turbine and sCO 2 power cycle, was supplied to Siemens PTI group for dynamic grid assessment, results of which are provided in appendices.

03 NATURAL GAS↗