Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “FELs”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 883 records · Page 49

SLAC National Accelerator Laboratory FACET & TEST BEAM FACILITIES PROPOSAL: Development of Electron Radiography for Material Science

The material science community is presently limited by diagnostics in both the fabrication of materials and measuring the resulting materials characteristics of these new fabrication techniques. Because of this limitation the community is forced into an empirical mode of material fabrication, where expert judgment is used to guide manufacturing processes and the resulting materials are inspected and tested for the desired characteristics. This development approach can be time consuming and costly. The solution to this problem is to improve our fundamental understanding of materials, which requires the development of new diagnostics capable of measurement at the micron length scale, during both processing and during testing. These new measurements will enable a fundamental understanding of material characteristics allowing the development of predictive models, which will in turn enable material engineering by design rather than today’s empirical approach. Solving this problem has become a grand challenge for the materials science community. Los Alamos plans to address this challenge through the development of new diagnostics capable of measurements at the smallest length scales through the Multi-Probe Diagnostic Hall (MPDH) at the planned MaRIE (Material and Radiation In Extremes) Facility. One of the probes will be a coherent photon beam generated by an FEL driven by a multi-GeV electron beam. The photons will be used for diffraction measurements as well as radiography of relatively thin samples (nearly single grains). The same multi-GeV electron beam can be used to directly radiograph thicker systems (many grains or “bulk” material), providing high resolution measurements of the density distribution of materials during both fabrication and dynamic testing. This technique, electron radiography or eRad, that has been identified by LANL as one of the probes required to meet this grand challenge has never been demonstrated with high energy electrons. We propose to begin development of this technique with the electron beam available at FACET.

47 OTHER INSTRUMENTATION↗

Theoretical and Computational Investigation of High-Brightness Beams

Theoretical and computational investigations of adiabatic thermal beams have been carried out in parameter regimes relevant to the development of advanced high-brightness, high-power accelerators for high-energy physics research and for various applications such as light sources. Most accelerator applications require high-brightness beams. This is true for high-energy accelerators such as linear colliders. It is also true for energy recovery linacs (ERLs) and free electron lasers (FELs) such as x-ray free electron lasers (XFELs). The breakthroughs and highlights in our research in the period from February 1, 2013 to November 30, 2013 were: a) Completion of a preliminary theoretical and computational study of adiabatic thermal Child-Langmuir flow (Mok, 2013); and b) Presentation of an invited paper entitled ?Adiabatic Thermal Beams in a Periodic Focusing Field? at Space Charge 2013 Workshop, CERN, April 16-19, 2013 (Chen, 2013). In this report, an introductory background for the research project is provided. Basic theory of adiabatic thermal Child-Langmuir flow is reviewed. Results of simulation studies of adiabatic thermal Child-Langmuir flows are discussed.

43 PARTICLE ACCELERATORS↗

Roughness Tolerance Studies for the Undulator Beam Pipe Chamber of LCLS-II

When a bunch passes through the undulator of LCLS-II, the wakefields of the vacuum chamber will result in an added energy variation along the bunch, one that can negatively impact the FEL performance. The wakefield of the vacuum chamber is primarily due to the resistance of the walls and the roughness of the surface. To minimize the impact of the wakes, one would like a wall surface smooth enough so that the roughness component of the wake is a small fraction of the total wake. In LCLS-I, with an undulator vacuum chamber of the same material (aluminum) and roughly the same aperture as proposed for LCLS-II, the wall roughness tolerance specified as an rms slope of the surface of (y') rms = 10–15 mr was difficult to achieve. The goal of this study is to understand the consequences to LCLS-II of loosening the roughness specification, say by a factor of 2 to 30 mr.

ACCPHY↗

Final Report: Development of a CW NCRF Photoinjector using Solid Freeform Fabrication

The development of very high duty cycle, high gradient photoinjectors is critical for the next generation of accelerator systems, such as X-ray free-electron lasers (FELs), inverse Compton scattering (ICS) sources, energy recovery linacs (ERLs), injectors for linear colliders, as well as a variety of industrial systems for homeland security applications. NCRF photoinjectors have a proven track record at generating the high-quality beams necessary for these applications, however they are limited in large part to relatively low duty cycles due to ohmic wall looses. Thus a key issue for high average power, normal conducting, photoinjectors is effective structure cooling [9]. The fabrication of current high average-power photoinjectors relies on conventional design and fabrication techniques with many limitations. Advances in Solid Freeform Fabrication (SFF) technology may make it possible to design and produce near net-shape copper structures for the next generation of very high rep rate, high gradient radio frequency (RF) photoinjectors. RF and thermal-management optimized geometries could be fully realized without the usual constraints and compromises of conventional machining techniques*. Further advances in SFF and powder metallurgy (P/M) techniques, with the ability to fine tune material properties, may soon make it possible to produce monolithic, thermally robust RF structures faster and cheaper than ever before.

Frigola, Pedro↗

X-ray Optics for BES Light Source Facilities

Each new generation of synchrotron radiation sources has delivered an increase in average brightness 2 to 3 orders of magnitude over the previous generation. The next evolution toward diffraction-limited storage rings will deliver another 3 orders of magnitude increase. For ultrafast experiments, free electron lasers (FELs) deliver 10 orders of magnitude higher peak brightness than storage rings. Our ability to utilize these ultrabright sources, however, is limited by our ability to focus, monochromate, and manipulate these beams with X-ray optics. X-ray optics technology unfortunately lags behind source technology and limits our ability to maximally utilize even today’s X-ray sources. With ever more powerful X-ray sources on the horizon, a new generation of X-ray optics must be developed that will allow us to fully utilize these beams of unprecedented brightness. The increasing brightness of X-ray sources will enable a new generation of measurements that could have revolutionary impact across a broad area of science, if optical systems necessary for transporting and analyzing X-rays can be perfected. The high coherent flux will facilitate new science utilizing techniques in imaging, dynamics, and ultrahigh-resolution spectroscopy. For example, zone-plate-based hard X-ray microscopes are presently used to look deeply into materials, but today’s resolution and contrast are restricted by limitations of the current lithography used to manufacture nanodiffractive optics. The large penetration length, combined in principle with very high spatial resolution, is an ideal probe of hierarchically ordered mesoscale materials, if zone-plate focusing systems can be improved. Resonant inelastic X-ray scattering (RIXS) probes a wide range of excitations in materials, from charge-transfer processes to the very soft excitations that cause the collective phenomena in correlated electronic systems. However, although RIXS can probe high-energy excitations, the most exciting and potentially revolutionary science involves soft excitations such as magnons and phonons; in general, these are well below the resolution that can be probed by today’s optical systems. The study of these low-energy excitations will only move forward if advances are made in high-resolution gratings for the soft X-ray energy region, and higher-resolution crystal analyzers for the hard X-ray region. In almost all the forefront areas of X-ray science today, the main limitation is our ability to focus, monochromate, and manipulate X-rays at the level required for these advanced measurements. To address these issues, the U.S. Department of Energy (DOE) Office of Basic Energy Sciences (BES) sponsored a workshop, X-ray Optics for BES Light Source Facilities, which was held March 27–29, 2013, near Washington, D.C. The workshop addressed a wide range of technical and organizational issues. Eleven working groups were formed in advance of the meeting and sought over several months to define the most pressing problems and emerging opportunities and to propose the best routes forward for a focused R&D program to solve these problems. The workshop participants identified eight principal research directions (PRDs), as follows: Development of advanced grating lithography and manufacturing for high-energy resolution techniques such as soft X-ray inelastic scattering. Development of higher-precision mirrors for brightness preservation through the use of advanced metrology in manufacturing, improvements in manufacturing techniques, and in mechanical mounting and cooling. Development of higher-accuracy optical metrology that can be used in manufacturing, verification, and testing of optomechanical systems, as well as at wavelength metrology that can be used for quantification of individual optics and alignment and testing of beamlines. Development of an integrated optical modeling and design framework that is designed and maintained specifically for X-ray optics. Development of nanolithographic techniques for improved spatial resolution and efficiency of zone plates. Development of large, perfect single crystals of materials other than silicon for use as beam splitters, seeding monochromators, and high-resolution analyzers. Development of improved thin-film deposition methods for fabrication of multilayer Laue lenses and high-spectral-resolution multilayer gratings. Development of supports, actuator technologies, algorithms, and controls to provide fully integrated and robust adaptive X-ray optic systems. Development of fabrication processes for refractive lenses in materials other than silicon. The workshop participants also addressed two important nontechnical areas: our relationship with industry and organization of optics within the light source facilities. Optimization of activities within these two areas could have an important effect on the effectiveness and efficiency of our overall endeavor. These are crosscutting managerial issues that we identified as areas that needed further in-depth study, but they need to be coordinated above the individual facilities. Finally, an issue that cuts across many of the optics improvements listed above is routine access to beamlines that ideally are fully dedicated to optics research and/or development. The success of the BES X-ray user facilities in serving a rapidly increasing user community has led to a squeezing of beam time for vital instrumentation activities. Dedicated development beamlines could be shared with other R&D activities, such as detector programs and novel instrument development. In summary, to meet the challenges of providing the highest-quality X-ray beams for users and to fully utilize the high-brightness sources of today and those that are on the horizon, it will be critical to make strategic investments in X-ray optics R&D. This report can provide guidance and direction for effective use of investments in the field of X-ray optics and potential approaches to develop a better-coordinated program of X-ray optics development within the suite of BES synchrotron radiation facilities. Due to the importance and complexity of the field, the need for tight coordination between BES light source facilities and with industry, as well as the rapid evolution of light source capabilities, the workshop participants recommend holding similar workshops at least biannually.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Gridded thermionic gun and integral superconducting ballistic bunch compression cavity

Electron-Ion colliders such as the Medium energy Electron Ion Collider (MEIC) being developed by JLAB require high current electrons with low energy spread for electron cooling of the collider ring. Accelerator techniques for improving bunch charge, average current, emittance, and energy spread are required for Energy Recovery Linacs (ERLs) and Circulator Rings (CR) for next generation colliders for nuclear physics experiments. Example candidates include thermionic-cathode electron guns with RF accelerating structures. Thermionic cathodes are known to produce high currents and have excellent lifetime. The success of the IR and THz Free-Electron Laser (FEL) designed and installed by Advanced Energy Systems at the Fritz Haber Institute (FHI) of the Max Planck Society in Berlin [1,2] demonstrates that gridded thermionic cathodes and rf systems be considered for next generation collider technology. In Phase 1 Advanced Energy Systems (AES) developed and analyzed a design concept using a superconducting cavity pair and gridded thermionic cathode. Analysis included Beam Dynamics and thermal analysis to show that a design of this type is feasible. The latest design goals for the MEIC electron cooler were for electron bunches of 420 pC at a frequency of 952.6 MHz with a magnetic field on the cathode of 2kG. This field magnetizes the beam imparting angular momentum that provides for helical motion of the electrons in the cooling solenoid. The helical motion increases the interaction time and improves the cooling efficiency. A coil positioned around the cathode providing 2kG field was developed. Beam dynamics simulations were run to develop the particle dynamics near the cathode and grid. Lloyd Young added capability to Tstep to include space charge effects between two plates and include image charge effects from the grid. He also added new pepper-pot geometry capability to account for honeycomb grids. These additions were used to develop the beam dynamics for this gun. The general design is a modified ballistic compression cavity pair with two independently powered cells [3]. The first is a cathode cell that includes the thermionic cathode and grid to provide for beam bunching. The second is a full cell with independent phasing and field levels designed to minimize energy spread. The primary goal for Phase II is to manufacture a superconducting gun with a thermionic cathode and imbedded coil. The system developed here is applicable to many high current electron accelerators. The analysis and design constraints imposed by the magnetized cathode make the cathode system developed here more complicated and limited than one without the magnetized beam constraints. High power ERLs would benefit by a gun with the capabilities shown here, 400 mA or more of current. ERLs hold great promise for electron cooling experiments, advanced light sources and Free Electron Lasers. This high current electron injector is a technological advance that will place the requirements for an ERL capable of providing quality bunches needed for cooling within the MEIC circulator ring within reach. This injector would have application to future ERLs around the world.

43 PARTICLE ACCELERATORS↗

Using superconducting undulator for enhanced imaging capabilities of MaRIE

MaRIE x-ray free electron laser (FEL) is envisioned to deliver a burst of closely spaced in time pulses for enabling the capability of studying the dynamic processes in a sample. MaRIE capability can be largely enhanced using the superconducting undulator, which has the capability of doubling its period. This technology will allow reaching the photon energy as low as ~200-500 eV. As a result, the MaRIE facility will have a broader photon energy range enabling a larger variety of experiments. The soft x-ray capability is more likely to achieve the 3D imaging of dynamic processes in noncrystal materials than the hard x-ray capability alone.

42 ENGINEERING↗

Cancellation of RF Coupler-Induced Emittance Due to Astigmatism

It is well-known that the electron beam quality required for applications such as FEL’s and ultra-fast electron diffraction can be degraded by the asymmetric fields introduced by the RF couplers of superconducting linacs. This effect is especially troublesome in the injector where the low energy beam from the gun is captured into the first high gradient accelerator section. Unfortunately modifying the established cavity design is expensive and time consuming, especially considering that only one or two sections are needed for an injector. Instead, it is important to analyze the coupler fields to understand their characteristics and help find less costly solutions for their cancellation and mitigation. This paper finds the RF coupler-induced emittance for short bunches is mostly due to the transverse spatial sloping or tilt of the field, rather than the field’s time-dependence. It is shown that the distorting effects of the coupler can be canceled with a static (DC) quadrupole lens rotated about the z-axis.

43 PARTICLE ACCELERATORS↗

Assessing the quantum physics impacts on future x-ray free-electron lasers

A new quantum mechanical theory of x-ray free electron lasers (XFELs) has been successfully developed that has placed LANL at the forefront of the understanding of quantum effects in XFELs. Our quantum theory describes the interaction of relativistic electrons with x-ray radiation in the periodic magnetic field of an undulator using the same mathematical formalism as classical XFEL theory. This places classical and quantum treatments on the same footing and allows for a continuous transition from one regime to the other eliminating the disparate analytical approaches previously used. Moreover, Dr. Anisimov, the architect of this new theory, is now considered a resource in the international FEL community for assessing quantum effects in XFELs.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Fundamental Power Coupler Technical Development - Final CRADA Report

The SLAC ‘Linac Coherent Light Source -II’ project (LCLS II) is a hard X-ray Free Electron Laser now under construction in support of photon-based material science. LCLS II uses a superconducting linac design based on the twenty year-long TESLA- Technology development effort. The TESLA proposal, the European XFEL (EU-XFEL) project, and the ILC design employ a pulsed superconducting linac with roughly 0.5% duty factor. This aspect was changed for LCLS II so that the FEL could be operated continuous-wave (CW) namely with a 100% duty factor. Several critical changes to the linac design were required including RF power distribution, cryogenic heat-load management and cavity preparation. This note lists the changes required to the fundamental power coupler (FPC). All of these changes were made by the SLAC physics and engineering teams and reviewed by the cryomodule design lead (Fermilab) and international partners. Testing was done by the LCLS II cryomodule teams (Jefferson Lab and Fermilab). The SLAC LCLS II project team managed the design and procurement process. The LCLS II fundamental power coupler design is based upon the DESY TESLA Test Facility (TTF-3) design. DESY shared their drawings with LCLS II and SLAC copied and modified them to meet the LCLS II CW operation power and heat-load requirements. LCLS II had an external reviewer evaluate and compare SLAC drawings to EU-XFEL drawings. SLAC used the same industrial partners that EU-XFEL used.

47 OTHER INSTRUMENTATION↗

Phase-Space Manipulations of Electron Beams for X-Ray Free-Electron Lasers and Inverse Compton Scattering Sources [Thesis]

This dissertation describes advanced techniques of phase space manipulations of the electron beam for improving performance and efficiency of high brightness X-ray light sources based on the free-electron Laser (FEL) and inverse-Compton scattering (ICS) processes. In particular, it first discusses a novel bunch-compression scheme based on a double transverseto-longitudinal phase-space exchanger – dubbed emittance exchanger (EEX) – separated by a demagnifying transverse-optics system. While the outline of the scheme is quite sophisticated, the basic physics behind it is quite straight-forward. The benefits and disadvantages of these scheme are compared to the conventional approach of compressing a bunch using a magnetic bunch-compression chicane.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

REACH Technology Pilot Plant

REACH technology is a very promising and novel technology to efficiently convert raw biomass into drop-in jet fuel and diesel hydrocarbon blend stocks. Preparatory R&D was successfully completed at CSIRO and Purdue University. Pre-engineering and scale-up activities were completed at Purdue, MSUBI, and the University of Maine. And FEL and other engineering activities were completed.

09 BIOMASS FUELS↗

Probing Ultrafast Electron (De)localization Dynamics in Mixed Valence Complexes Using Femtosecond X-ray Spectroscopy (Final Report)

The overall goal of this research program was to understand valence electron and vibrational motion following metal-to-metal charge transfer (MMCT) excitation in the mixed valence complexes dissolved in aqueous solution. The project objectives were (i) to observe the time-dependent re-arrangement of d electrons across two transition metal sites and the bridging ligand following photoinduced MMCT excitation on a sub-50 femtosecond timescale using femtosecond X-ray pulses generated at LCLS (ii) to simulate femtosecond X-ray absorption and emission spectra of solvated, photo-excited, transition metal mixed valence complexes using a realistic treatment of multi-electron correlations/transitions, spin-orbit coupling and final state lifetime effects and to propose and study the feasibility of nonlinear X-ray experiments on solvated transition metal mixed valence systems using future X-FEL light sources and (iii) to determine the role of coupled electronic and vibrational motions during ultrafast photoinduced charge transfer. The final report highlights the scientific results obtained during this funding period.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Ultracold Storage Ring

The modern ring upgrades aim at reaching beam low emittance while paying little attention to the beam energy spread. The purpose of this note is to conjecture on a possibility of designing a storage ring with ultimately small energy spread. This might be of interest with respect to the following two applications: increasing brightness and coherence of radiation at higher harmonics of undulator radiation and a potential of building a soft X-ray FEL on a storage ring. Throughout the tech note we are taking a 3 GeV storage ring of the NSLS-II size as an example.

43 PARTICLE ACCELERATORS↗

Final Report: Next Generation Diamond Drumhead X-Ray Optics

Problem / Opportunity Statement: Future high-impact scientific applications at synchrotron and Free-Electron Laser (FEL) X-ray sources require the development of processing and mounting methods for ultra-thin diamond crystals to meet the most challenging needs of pioneering research at next generation light source facilities. These methods should be capable of manufacturing crystal plates as thin as 10 micrometers over an area of a few mm2, and with a surface cut in different crystal orientations, such as the diamond {100}, {111}, {110} and {113} planes. Project Purpose and Approach: In Phase I, Great Lakes Crystal Technologies (GLCT) partnered with Stonybrook University (SUNY) to created thin diamond drumhead crystals. The purpose of the Phase I project is to transfer the drumhead membrane window etching technology from SUNY to GLCT. Testing of a device using the beamline at Stanford Linear Accelerator Laboratory was initially planned, however, a delay on the part of a third party service provided required us to get beamline testing done at Argonne National Laboratory. Phase I Taskwork: Testing of a high purity diamond plate thinning and etching process was performed. By SUNY and GLCT. Plates were sent to a third party service provider for thinning to ~100 microns, however, delays required that GLCT develop an in-house thinning process to complete the taskwork. GLCT successfully developed this in-house capability even though it was initially planned to be part of the Phase II Taskwork. Multiple practice and deliverable plates were provided to SUNY to be etched into the target drumhead devices. GLCT practiced and refined an in-house plate thinning process and produced five plates with thicknesses in the 60 – 150 micron range. Processing of the plates has begun and will continue in a no-cost extension period necessitated by the third party service provider delay. GLCT also procured and installed a reactive ion etching/inductively coupled plasma system. In addition, one of the thinned plates was measured at the Applied Photon Source at APL for a pre-processing assessment of the crystalline strain. After processing the plate into a drumhead and annealing, a post-processing assessment of the strain will be performed. Phase I Results: The initial data from GLCT’s plate thinning process development, SUNY’s drumhead etching processing, and characterization at APS/ANL demonstrate our teams capabilities to achieve the project goals. Commercial Applications & Benefits: The proposed technology will benefit advanced x-ray science performed at BNL and the 70+ additional advanced beamlines around the world. There are also a number of medical and homeland security applications which could benefit from the technology.

Quayle, Paul↗

Accelerators for Electroweak Physics and Higgs Boson Studies

We discuss the goals, the designs, the state of technical readiness, and the critical R&D needs of the accelerators that are currently under discussion as Higgs and electroweak factories. We also address the respective staging options enabling future energy-frontier colliders. The accelerators covered are based on many different techniques and approaches. They include several circular colliders, various linear colliders, colliders based on energy recovery linacs (ERLs), ERL-ring combinations, as well as γγ colliders. The linear colliders proposed consist of options for the International Linear Collider (ILC), for the Compact Linear Collider (CLIC), for the Cold Copper Collider (C 3 ), and for the more recent Higgs-Energy Lepton Collider (HELEN). ERLs are key components of the Recycling Linear e + e - Collider (ReLiC),of the Energy Recovery Linear Collider (ERLC), and of the Circular Energy Recovery Collider (CERC). Among the more conventional ring colliders the following proposals are featured: the Future Circular Collider (FCC-ee), the Circular Electron Positron Collider (CEPC), the Electron Positron Circular Collider at Fermilab (EPCCF), and the Large Electron Positron collider #3 (LEP-3). In addition, we consider the X-ray FEL based gamma- gamma Collider Higgs Factory (XCC) and the High-Energy High-Luminosity γ-γ collider (HE&HL γγ). Finally, a Higgs factory based on a circular muon collider is mentioned for completeness.

43 PARTICLE ACCELERATORS↗

High Energy ERLs for Electron Cooling

Future electron-ion colliders such as the recently approved eRHIC collide high-intensity ion beams with high current electron beams. The electron beams take advantage of synchrotron radiation to damp emittances but the ion beams must be cooled via some beam-cooling mechanism, including electron cooling. The ion energies are typically a few hundreds of GeV per nucleon. At this energy, a DC cooler powered by an electrostatic accelerator, the preferred cooling approach on existing machines, is not feasible. An ERL, in principle, can provide the high current and brightness to cool these high-brightness ion beams. The beam quality requirements are much different from previous ERLs designs used for FELs. The cooling bunch must be very long to match the ion beam and the relative energy spread must be very small. Incoherent cooling can be enhanced with magnetized beams, but the magnetization must be maintained throughout the ERL. An alternate cooling mechanism, the so-called Coherent Electron Cooling, is, in principle, stronger and can be done with non-magnetized beams. We will present two applications of an ERL to high energy electron cooling and describe some of the technical challenges that must be overcome to operate such an ERL

Benson, Stephen↗

Analysis and Management of Microphonics in Operational SRF Cavities With Bandwidths of approximately 10 Hz

Superconducting Radio Frequency Cavity detuning can be due to several effects. These effects include helium pressure variations, vibrations driven by external narrow band sources such as HVAC motors, cooling water systems, tuner motor operation, cryogenic system machinery, and occasionally cryogenic system instabilities such as thermo-acoustic oscillations. They can also be driven by broadband white or pink noise which, in general, will excite the resonant modes of the structure. All of these affect the cavity resonant frequency. Variations that occur at frequencies above a few tenths of a Hertz are considered microphonics. CEBAF 0.7 m C100 cavities operated at 1500 MHz with 20 Hz bandwidths, changes in cavity lengths on the order of 10 nm are sufficient to shift the cavity frequency by more than one bandwidth. Jefferson Lab is the first lab to install and operate a large number of SRF cavities with relatively high loaded-Qs, 88 in CEBAF and 16 in the LERF (previously the FEL). Production was halted for several months after the first 3 production C100 cryomodules were built, and modifications were developed in order to reduce the background microphonics. Additionally, in the spring of 2016 we started a program to harden and damp the cryomodule interface structures in order to reduce the sensitivity to outside perturbations as well as to damp out the natural vibrational modes of the structures. This work will focus on the approaches and measurements that one should consider when designing a system in order to understand the modal nature of the structure, the measurement techniques for determining the extent of the microphonics, and the mitigations that can be implemented in order to reduce the effects of outside perturbances. Examples of results at various other institutions will also be presented.

Powers, Thomas↗