Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Energy proportionality”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 883 records · Page 49

Prospects for High Energy Resolution Gamma Ray Spectroscopy with Europium-Doped Strontium Iodide

Europium-doped strontium iodide scintillators offer a light yield exceeding 100,000 photons/MeV and excellent light yield proportionality, while at the same time, SrI{sub 2} is readily grown in single crystal form. Thus far, our collaboration has demonstrated an energy resolution with strontium iodide of 2.6% at 662 keV and 7.6% at 60 keV, and we have grown single crystals surpassing 30 cm{sup 3} in size (with lower resolution). Our analysis indicates that SrI{sub 2}(Eu) has the potential to offer 2% energy resolution at 662 keV with optimized material, optics, and read-out. In particular, improvements in feedstock purity may result in crystal structural and chemical homogeneity, leading to improved light yield uniformity throughout the crystal volume, and consequently, better energy resolution. Uniform, efficient light collection and detection, is also required to achieve the best energy resolution with a SrI{sub 2}(Eu) scintillator device.

36 MATERIALS SCIENCE↗

The evolution of grain boundary energy in textured and untextured Ca–doped alumina during grain growth

The role of anisotropic grain boundary energy in grain growth is investigated using textured microstructures that contain a high proportion of special grain boundaries. Textured and untextured Ca–doped alumina was prepared by slip casting inside and outside a high magnetic field, respectively. At 1600°C, the textured microstructure exhibits faster growth than the untextured microstructure and its population of low–angle boundaries increases. Atomic force microscopy (AFM) is employed to measure the geometry of thermal grooves to assess the relative grain boundary energy of these systems before and after growth. In the textured microstructure, the grain boundary energy distribution narrows and shifts to a lower average energy. Conversely, the energy distribution broadens for the untextured microstructure as it grows and exhibits abnormal grain growth. Further analysis of the boundary networks neighboring abnormal grains reveals an energy incentive that facilitates their growth. These results suggest that coarsening is not the only dominant grain growth mechanism and that the system can lower its energy effectively by replacing high energy boundaries with those of low energy. The faster growth of lower energy boundaries suggests that isotropic simulations do not adequately account for anisotropic grain growth mechanisms or anisotropic mobility.

36 MATERIALS SCIENCE↗

Electronic states in spherical GaN nanocrystals embedded in various dielectric matrices: The k ⋅ p-calculations

Using the envelope-function approximation, the single-particle states of electrons and holes in spherical GaN nanocrystals embedded in different amorphous dielectric matrices (SiO{sub 2}, Al{sub 2}O{sub 3}, HfO{sub 2} and Si{sub 3}N{sub 4}) have been calculated. Ground state energies of electrons and holes in GaN nanocrystals are determined using the isotropic approximation of the k ⋅ p -Hamiltonian. All the ground state energies are found to increase with lowering the nanocrystal size and are proportional to the R{sup −n}, where R is the nanocrystal radius, n =1.5-1.9 for electrons and 1.7-2.0 for holes. The optical gap of GaN nanocrystals changes from 3.8 to 5 eV for the nanocrystal radius ranging from 3 to 1 nm.

36 MATERIALS SCIENCE↗

INVERSE COMPTON SCATTERING MODEL FOR X-RAY EMISSION OF THE GAMMA-RAY BINARY LS 5039

We propose a model for the gamma-ray binary LS 5039 in which the X-ray emission is due to the inverse Compton (IC) process instead of the synchrotron radiation. Although the synchrotron model has been discussed in previous studies, it requires a strong magnetic field which leads to a severe suppression of the TeV gamma-ray flux in conflict with H.E.S.S. observations. In this paper, we calculate the IC emission by low energy electrons ({gamma}{sub e} {approx}< 10{sup 3}) in the Thomson regime. We find that IC emission of the low energy electrons can explain the X-ray flux and spectrum observed with Suzaku if the minimum Lorentz factor of injected electrons {gamma}{sub min} is around 10{sup 3}. In addition, we show that the Suzaku light curve is well reproduced if {gamma}{sub min} varies in proportion to the Fermi flux when the distribution function of injected electrons at higher energies is fixed. We conclude that the emission from LS 5039 is well explained by the model with the IC emission from electrons whose injection properties are dependent on the orbital phase. Since the X-ray flux is primarily determined by the total number of cooling electrons, this conclusion is rather robust, although some mismatches between the model and observations at the GeV band remain in the present formulation.

79 ASTRONOMY AND ASTROPHYSICS↗

The Psyche Gamma-Ray and Neutron Spectrometer

A Gamma-Ray and Neutron Spectrometer (GRNS) instrument has been developed as part of the science payload for NASA’s Discovery Program Psyche mission to the M-class asteroid (16) Psyche. The GRNS instrument is designed to measure the elemental composition of Psyche with the goal to understand the origin of this mysterious, potentially metal-rich planetary body. The GRNS will measure the near-surface abundances for the elements Ni, Fe, Si, K, S, Al, and Ca, as well as the spatial distribution of Psyche’s metal-to-silicate fraction (or metal fraction). These measurements address three of the five Psyche mission science objectives: determine if Psyche is a core; determine whether small metal bodies incorporate light elements into the metal phase; and determine whether Psyche was formed under reducing conditions. The Gamma-Ray Spectrometer (GRS) uses a cryocooled, high-purity Ge (HPGe) sensor to detect cosmic-ray generated gamma rays in the 60 to 9000-keV energy range. The HPGe sensor is surrounded by a borated plastic anticoincidence shield that provides three functions: active background rejection from charged particle interactions in the HPGe sensor; fast neutron measurements; and direct measurements of the incident galactic cosmic ray flux. The Neutron Spectrometer (NS) uses three 3 He gas proportional sensors, each with different material wraps to measure thermal (<0.4 eV), low-energy epithermal (0.4 eV to 1 keV), and high-energy epithermal (up to 100 keV) neutrons. This paper provides an overview of the Psyche GRNS, including: its science and measurement objectives; the design of the instrument hardware, software, and operation; pre-launch performance measurements and its initial performance in space; and an overview of its data products and expected operation for different Psyche mission phases.

Engineering - Instrumentation related to nuclear s↗

ADVANCED MIXING MODELS

The process of recovering the waste in storage tanks at the Savannah River Site (SRS) typically requires mixing the contents of the tank with one to four dual-nozzle jet mixers located within the tank. The typical criteria to establish a mixed condition in a tank are based on the number of pumps in operation and the time duration of operation. To ensure that a mixed condition is achieved, operating times are set conservatively long. This approach results in high operational costs because of the long mixing times and high maintenance and repair costs for the same reason. A significant reduction in both of these costs might be realized by reducing the required mixing time based on calculating a reliable indicator of mixing with a suitably validated computer code. The work described in this report establishes the basis for further development of the theory leading to the identified mixing indicators, the benchmark analyses demonstrating their consistency with widely accepted correlations, and the application of those indicators to SRS waste tanks to provide a better, physically based estimate of the required mixing time. Waste storage tanks at SRS contain settled sludge which varies in height from zero to 10 ft. The sludge has been characterized and modeled as micron-sized solids, typically 1 to 5 microns, at weight fractions as high as 20 to 30 wt%, specific gravities to 1.4, and viscosities up to 64 cp during motion. The sludge is suspended and mixed through the use of submersible slurry jet pumps. To suspend settled sludge, water is added to the tank as a slurry medium and stirred with the jet pump. Although there is considerable technical literature on mixing and solid suspension in agitated tanks, very little literature has been published on jet mixing in a large-scale tank. If shorter mixing times can be shown to support Defense Waste Processing Facility (DWPF) or other feed requirements, longer pump lifetimes can be achieved with associated operational cost and schedule savings. The focus of the present work is to establish mixing criteria associated with the waste processing at SRS and to quantify the mixing time required to suspend sludge particles with the submersible jet pump. Literature results for a turbulent jet flow are reviewed briefly, since the decay of the axial jet velocity and the evolution of the jet flow patterns are important phenomena affecting sludge suspension and mixing operations. One of the main objectives in the waste processing is to provide the DWPF a uniform slurry composition at a certain weight percentage (typically {approx}13 wt%) over an extended period of time. In preparation of the sludge for slurrying to DWPF, several important questions have been raised with regard to sludge suspension and mixing of the solid suspension in the bulk of the tank: (1) How much time is required to prepare a slurry with a uniform solid composition for DWPF? (2) How long will it take to suspend and mix the sludge for uniform composition in any particular waste tank? (3) What are good mixing indicators to answer the questions concerning sludge mixing stated above in a general fashion applicable to any waste tank/slurry pump geometry and fluid/sludge combination? Grenville and Tilton (1996) investigated the mixing process by giving a pulse of tracer (electrolyte) through the submersible jet nozzle and by monitoring the conductivity at three locations within the cylindrical tank. They proposed that the mixing process was controlled by the turbulent kinetic energy dissipation rate in the region far away from the jet entrance. They took the energy dissipation rates in the regions remote from the nozzle to be proportional to jet velocity and jet diameter at that location. The reduction in the jet velocity was taken to be proportional to the nozzle velocity and distance from the nozzle. Based on their analysis, a correlation was proposed. The proposed correlation was shown to be valid over a wide range of Reynolds numbers (50,000 to 300,000) with a relative standard deviation of {+-} 11.83%. An improved correlation including the effect of circulation time was proposed by Grenville and Tilton [11] via a better fit of mixing time data for turbulent jet mixing under a wider range of jet Reynolds numbers (50,000 to 300,000). The circulation time was defined as the liquid volume divided by the entrained flow rate. They assumed that the mixing rate at the end of the jet length controls the mixing time for the entire tank by estimating the kinetic energy dissipation rate as discussed earlier. They predicted that for a given volume, an optimum geometry exists for a mixing vessel, allowing a desired mixing time to be achieved for a minimum power input. The current work will compare their correlation of the jet mixing time with CFD modeling results for their experimental tanks in an attempt to achieve a fundamental understanding of the turbulent jet mixing and to establish mixing indicators.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

FERMI LARGE AREA TELESCOPE VIEW OF THE CORE OF THE RADIO GALAXY CENTAURUS A

We present {gamma}-ray observations with the Large Area Telescope (LAT) on board the Fermi Gamma-Ray Space Telescope of the nearby radio galaxy Centaurus A (Cen A). The previous EGRET detection is confirmed, and the localization is improved using data from the first 10 months of Fermi science operation. In previous work, we presented the detection of the lobes by the LAT; in this work, we concentrate on the {gamma}-ray core of Cen A. Flux levels as seen by the LAT are not significantly different from that found by EGRET, nor is the extremely soft LAT spectrum ({Gamma} = 2.67 {+-} 0.10{sub stat} {+-} 0.08{sub sys} where the photon flux is {Phi} {proportional_to} E {sup -{Gamma}}). The LAT core spectrum, extrapolated to higher energies, is marginally consistent with the non-simultaneous HESS spectrum of the source. The LAT observations are complemented by simultaneous observations from Suzaku, the Swift Burst Alert Telescope and X-ray Telescope, and radio observations with the Tracking Active Galactic Nuclei with Austral Milliarcsecond Interferometry program, along with a variety of non-simultaneous archival data from a variety of instruments and wavelengths to produce a spectral energy distribution (SED). We fit this broadband data set with a single-zone synchrotron/synchrotron self-Compton model, which describes the radio through GeV emission well, but fails to account for the non-simultaneous higher energy TeV emission observed by HESS from 2004 to 2008. The fit requires a low Doppler factor, in contrast to BL Lac objects which generally require larger values to fit their broadband SEDs. This indicates that the {gamma}-ray emission originates from a slower region than that from BL Lac objects, consistent with previous modeling results from Cen A. This slower region could be a slower moving layer around a fast spine, or a slower region farther out from the black hole in a decelerating flow. The fit parameters are also consistent with Cen A being able to accelerate ultra-high energy cosmic-rays, as hinted at by results from the Auger observatory.

79 ASTRONOMY AND ASTROPHYSICS↗

Observation of fast-ion Doppler-shifted cyclotron resonance with shear Alfven waves

The Doppler-shifted cyclotron resonance ({omega}-k{sub z}v{sub z}={omega}{sub f}) between fast ions and shear Alfven waves is experimentally investigated ({omega}, wave frequency; k{sub z}, axial wavenumber; v{sub z}, fast-ion axial speed; {omega}{sub f}, fast-ion cyclotron frequency). A test particle beam of fast ions is launched by a Li{sup +} source in the helium plasma of the LArge Plasma Device (LAPD) [W. Gekelman, H. Pfister, Z. Lucky, J. Bamber, D. Leneman, and J. Maggs, Rev. Sci. Instrum. 62, 2875 (1991)], with shear Alfven waves (SAW) (amplitude {delta} B/B up to 1%) launched by a loop antenna. A collimated fast-ion energy analyzer measures the nonclassical spreading of the beam, which is proportional to the resonance with the wave. A resonance spectrum is observed by launching SAWs at 0.3-0.8{omega}{sub ci}. Both the magnitude and frequency dependence of the beam-spreading are in agreement with the theoretical prediction using a Monte Carlo Lorentz code that launches fast ions with an initial spread in real/velocity space and random phases relative to the wave. Measured wave magnetic field data are used in the simulation.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Caesium Free Negative Ion Sources for Neutral Beam Injectors: a Study of Negative Ion Production on Graphite Surface in Hydrogen and Deuterium Plasma

Negative ion generation on HOPG graphite surface has been studied in hydrogen and deuterium plasma. We measure Ion Distribution Function (IDF) of negative ions coming from graphite surface bombarded by positive ions in H{sub 2}/D{sub 2} plasmas. We showed that negative ions flux was proportional to positive ion flux and was strongly dependant on impinging energy. IDF study shows two generation mechanisms are involved: sputtering of adsorbed H/D as negative ions and, in a less important way, double electron capture. We compare H{sub 2}/D{sub 2} plasmas, and point out isotopic effect between H{sup -} and D{sup -} production.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Innovative measurement of Debye shielding in plasmas by Lyman-α radiation of a probing metastable hydrogen beam

Answering to a long-standing challenge, a new way to non-intrusively measure weak electric fields in plasmas is presented. Here we show it using an H(2s) atomic probe beam, obtained from the conversion of H{sup +} ions into H(2s) either by collisions with H{sub 2} residual gas or in a resonant charge exchange cesium cell. The probe beam is sent between two polarized plates creating an electric field applied within a thermionic plasma. Indeed the interaction between a metastable H(2s) atomic hydrogen beam and an external electric field leads to the emission of the Lyman-alpha line owing to the Stark mixing of the 2s{sub 1/2} and 2p{sub 1/2} levels. When the field is weak, it can be treated as a perturbation of these two states separated by a small amount of energy called Lamb-shift. It induces a radiation with intensity proportional to the square modulus of the electric field which is measured in a direction perpendicular to the probe beam. Contrary to measurements in vacuum, the Debye sheath formation is clearly observed in the presence of plasma. This contribution reviews: presentation of Stark mixing of the 2s{sub 1/2} and 2p{sub 1/2} levels and of Lamb shift for hydrogen-like atoms, brief description of the experimental set-up, observation of the formation of a sheath between two polarized plane electrodes in a plasma, either with a probe ion beam, or atom beam.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A self-consistent regime of generation of terahertz radiation by an optical pulse with a tilted intensity front

We derived a self-consistent system of nonlinear wave equations describing the terahertz generation in dielectric uniaxial crystals by optical pulsed radiation with a tilted wavefront. The numerical analysis of the system of equations showed that the generation of a broadband one-period terahertz signal is accompanied by a red shift of the carrier frequency of the optical pulse, the magnitude of the shift being proportional to the pulse intensity. The generation efficiency with respect to energy reached a maximum at a certain distance of propagation in the crystal, after which the efficiency decreased. A satisfactory agreement was obtained between theoretical calculations and experimental data of other investigations. (generation of terahertz radiation)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Design, construction and commissioning of the Digital Hadron Calorimeter—DHCAL

A novel hadron calorimeter is being developed for future lepton colliding beam detectors. The calorimeter is optimized for the application of Particle Flow Algorithms (PFAs) to the measurement of hadronic jets and features a very finely segmented readout with 1 × 1 cm(2) cells. The active media of the calorimeter are Resistive Plate Chambers (RPCs) with a digital, i.e. one-bit, readout. To first order the energy of incident particles in this calorimeter is reconstructed as being proportional to the number of pads with a signal over a given threshold. A large-scale prototype calorimeter with approximately 500,000 readout channels has been built and underwent extensive testing in the Fermilab and CERN test beams. This paper reports on the design, construction, and commissioning of this prototype calorimeter.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Tight upper bound of the maximum speed of evolution of a quantum state

I report a tight upper bound of the maximum speed of evolution from one quantum state {rho} to another {rho}{sup '} with fidelity F({rho},{rho}{sup '}) less than or equal to an arbitrary but fixed value under the action of a time-independent Hamiltonian. Since the bound is directly proportional to the average absolute deviation from the median of the energy of the state DE, one may interpret DE as a meaningful measure of the maximum information-processing capability of a system.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Centrality-Dependent Modification of Jet-Production Rates in Deuteron-Gold Collisions at s N N = 200 GeV

We measured jet production rates in p+p and d+Au collisions at s N N = 200 GeV recorded in 2008 with the PHENIX detector at the Relativistic Heavy Ion Collider. Jets are reconstructed using the R=0.3 anti-k t algorithm from energy deposits in the electromagnetic calorimeter and charged tracks in multiwire proportional chambers, and the jet transverse momentum (p T ) spectra are corrected for the detector response. Spectra are reported for jets with 12 T <50 GeV/c, within a pseudorapidity acceptance of |η|<0.3. The nuclear-modification factor (R dAu ) values for 0%–100% d+Au events are found to be consistent with unity, constraining the role of initial state effects on jet production. Nonetheless, the centrality-selected R dAu values and central-to-peripheral ratios (R CP ) show large, p T -dependent deviations from unity, challenging the conventional models that relate hard-process rates and soft-particle production in collisions involving nuclei.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Superficial dosimetry imaging based on Čerenkov emission for external beam radiotherapy with megavoltage x-ray beam

Purpose: Čerenkov radiation emission occurs in all tissue, when charged particles (either primary or secondary) travel at velocity above the threshold for the Čerenkov effect (about 220 KeV in tissue for electrons). This study presents the first examination of optical Čerenkov emission as a surrogate for the absorbed superficial dose for MV x-ray beams.Methods: In this study, Monte Carlo simulations of flat and curved surfaces were studied to analyze the energy spectra of charged particles produced in different regions near the surfaces when irradiated by MV x-ray beams. Čerenkov emission intensity and radiation dose were directly simulated in voxelized flat and cylindrical phantoms. The sampling region of superficial dosimetry based on Čerenkov radiation was simulated in layered skin models. Angular distributions of optical emission from the surfaces were investigated. Tissue mimicking phantoms with flat and curved surfaces were imaged with a time domain gating system. The beam field sizes (50 × 50–200 × 200 mm{sup 2}), incident angles (0°–70°) and imaging regions were all varied.Results: The entrance or exit region of the tissue has nearly homogeneous energy spectra across the beam, such that their Čerenkov emission is proportional to dose. Directly simulated local intensity of Čerenkov and radiation dose in voxelized flat and cylindrical phantoms further validate that this signal is proportional to radiation dose with absolute average discrepancy within 2%, and the largest within 5% typically at the beam edges. The effective sampling depth could be tuned from near 0 up to 6 mm by spectral filtering. The angular profiles near the theoretical Lambertian emission distribution for a perfect diffusive medium, suggesting that angular correction of Čerenkov images may not be required even for curved surface. The acquisition speed and signal to noise ratio of the time domain gating system were investigated for different acquisition procedures, and the results show there is good potential for real-time superficial dose monitoring. Dose imaging under normal ambient room lighting was validated, using gated detection and a breast phantom.Conclusions: This study indicates that Čerenkov emission imaging might provide a valuable way to superficial dosimetry imaging in real time for external beam radiotherapy with megavoltage x-ray beams.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-E-J-09: A Monte Carlo Analysis of the Relationship Between Cherenkov Light Emission and Dose for Electrons, Protons, and X-Ray Photons

Purpose: A number of recent studies have proposed that light emitted by the Cherenkov effect may be used for a number of radiation therapy dosimetry applications. Here we investigate the fundamental nature and accuracy of the technique for the first time by using a theoretical and Monte Carlo based analysis. Methods: Using the GEANT4 architecture for medically-oriented simulations (GAMOS) and BEAMnrc for phase space file generation, the light yield, material variability, field size and energy dependence, and overall agreement between the Cherenkov light emission and dose deposition for electron, proton, and flattened, unflattened, and parallel opposed x-ray photon beams was explored. Results: Due to the exponential attenuation of x-ray photons, Cherenkov light emission and dose deposition were identical for monoenergetic pencil beams. However, polyenergetic beams exhibited errors with depth due to beam hardening, with the error being inversely related to beam energy. For finite field sizes, the error with depth was inversely proportional to field size, and lateral errors in the umbra were greater for larger field sizes. For opposed beams, the technique was most accurate due to an averaging out of beam hardening in a single beam. The technique was found to be not suitable for measuring electron beams, except for relative dosimetry of a plane at a single depth. Due to a lack of light emission, the technique was found to be unsuitable for proton beams. Conclusions: The results from this exploratory study suggest that optical dosimetry by the Cherenkov effect may be most applicable to near monoenergetic x-ray photon beams (e.g. Co-60), dynamic IMRT and VMAT plans, as well as narrow beams used for SRT and SRS. For electron beams, the technique would be best suited for superficial dosimetry, and for protons the technique is not applicable due to a lack of light emission. NIH R01CA109558 and R21EB017559.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Generation of Terahertz Waves under Laser Action on Hot Dense Plasma

Generation of terahertz waves by hot dense plasma under the action of a femtosecond laser pulse in the regime of anomalous skin effect is considered. The spectral, angular, and energy characteristics of terahertz waves are studied as functions of the plasma and laser parameters. It is shown that, under the conditions of anomalous skin effect, which takes place in ultradense hot plasma, the total energy of the terahertz signal is independent of the electron density, proportional to the square of the electron temperature, and maximal at tight focusing of the laser pulse.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Second-order microscopic nonlinear susceptibility in a centrosymmetric material: application to imaging valence electron motion

We report measurements of phase-matched nonlinear x-ray and optical sum-frequency generation from single-crystal silicon using sub-resonant 0.95 eV laser pulses and 9.5 keV hard x-ray pulses from the LCLS free-electron laser. The sum-frequency signal appears as energy and momentum sidebands to the elastic Bragg peak. It is proportional to the magnitude squared of the relevant temporal and spatial Fourier components of the optically induced microscopic charges/currents. We measure the first- and second-order sideband to the 220 Bragg peak and find that the efficiency is maximized when the applied field is along the reciprocal lattice vector. For an optical intensity of $\sim10^{12} \text{W}/\text{cm}^2$, we measure peak efficiencies of $3\times 10^{-7}$ and $3\times 10^{-10}$ for the first and second-order sideband respectively (relative to the elastic Bragg peak). The first-order sideband is consistent with induced microscopic currents along the applied electric field (consistent with an isotropic response). The second-order sideband depends nontrivially on the optical field orientation and is consistent with an anisotropic response originating from induced charges along the bonds with C$_{3v}$ site symmetry. The results agree well with first-principles Bloch-Floquet calculations.

FOS: Physical sciences↗