Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Energy Management”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 883 records · Page 49

Solar Photovoltaic Systems in Hurricanes and Other Severe Weather

Field examinations of hurricane-damaged photovoltaic systems have revealed important design, construction, and operational factors that greatly influence a system's survivability from a severe weather event. The U.S. Department of Energy Federal Energy Management Program (FEMP) is expanding its recommended design specifications to include factors and best practices for system survivability identified from 2017 hurricanes. This fact sheet provides an overview of the upcoming additions to these design specifications.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Appliance Commitment for Household Load Scheduling

This paper presents a novel appliance commitment algorithm that schedules thermostatically-controlled household loads based on price and consumption forecasts considering users comfort settings to meet an optimization objective such as minimum payment or maximum comfort. The formulation of an appliance commitment problem was described in the paper using an electrical water heater load as an example. The thermal dynamics of heating and coasting of the water heater load was modeled by physical models; random hot water consumption was modeled with statistical methods. The models were used to predict the appliance operation over the scheduling time horizon. User comfort was transformed to a set of linear constraints. Then, a novel linear, sequential, optimization process was used to solve the appliance commitment problem. The simulation results demonstrate that the algorithm is fast, robust, and flexible. The algorithm can be used in home/building energy-management systems to help household owners or building managers to automatically create optimal load operation schedules based on different cost and comfort settings and compare cost/benefits among schedules.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Status Report on the High-Temperature Steam Electrolysis Plant Model Developed in the Modelica Framework (FY17)

This report has been prepared as part of an effort to design and build a modeling and simulation (M&S) framework to assess the economic viability of a nuclear-renewable hybrid energy system (N-R HES). In order to facilitate dynamic M&S of such an integrated system, research groups in multiple national laboratories have been developing various subsystems as dynamic physics-based components using the Modelica programming language. In fiscal year 2015 (FY15), Idaho National Laboratory (INL) performed a dynamic analysis of two region-specific N-R HES configurations, including the gas-to-liquid (natural gas to Fischer-Tropsch synthetic fuel) and brackish water reverse osmosis desalination plants as industrial processes. In FY16, INL developed two additional subsystems in the Modelica framework: (1) a high-temperature steam electrolysis (HTSE) plant as a high priority industrial plant to be integrated with a light water reactor (LWR) within an N-R HES and (2) a gas turbine power plant as a secondary energy supply. In FY17, five new components (i.e., a feedwater pump, a multi-stage compression system, a sweep-gas turbine, flow control valves, and pressure control valves) have been incorporated into the HTSE system proposed in FY16, aiming to better realistically characterize all key components of concern. Special attention has been given to the controller settings based on process models (i.e., direct synthesis method), aiming to improve process dynamics and controllability. A dynamic performance analysis of the improved LWR/HTSE integration case was carried out to evaluate the technical feasibility (load-following capability) and safety of such a system operating under highly variable conditions requiring flexible output. The analysis (evaluated in terms of the step response) clearly shows that the FY17 model resulted in superior output responses with much smaller settling times and less oscillatory behavior in response to disturbances in the electric load than those observed with the FY16 model. Simulation results involving several case studies show that the suggested control scheme could maintain the controlled variables (including the steam utilization factor, cathode stream inlet composition, and temperatures and pressures of the process streams at various locations) within desired limits under various plant operating conditions. The results also indicate that the proposed HTSE plant could provide operational flexibility to participate in energy management at the utility scale by dynamically optimizing the use of excess plant capacity within an N-R HES.

08 HYDROGEN↗

Quick Guide: Power Purchase Agreements (Fact Sheet)

Introduction to Federal power purchase agreements (PPAs), including available FEMP services and technical assistance as well as questions to ask when evaluating PPAs for a Federal renewable energy project.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Optimal control of a repowered vehicle: Plug-in fuel cell against plug-in hybrid electric powertrain

This paper describes two different powertrain configurations for the repowering of a conventional vehicle, equipped with an internal combustion engine (ICE). A model of a mid-sized ICE-vehicle is realized and then modified to model both a parallel plug-in hybrid electric powertrain and a proton electrolyte membrane (PEM) fuel cell (FC) hybrid powertrain. The vehicle behavior under the application of an optimal control algorithm for the energy management is analyzed for the different scenarios and results are compared.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Analysis of Application Power and Schedule Composition in a High Performance Computing Environment

As the capacity of high performance computing (HPC) systems continues to grow, small changes in energy management have the potential to produce significant energy savings. In this paper, we employ an extensive informatics system for aggregating and analyzing real-time performance and power use data to evaluate energy footprints of jobs running in an HPC data center. We look at the effects of algorithmic choices for a given job on the resulting energy footprints, and analyze application-specific power consumption, and summarize average power use in the aggregate. All of these views reveal meaningful power variance between classes of applications as well as chosen methods for a given job. Using these data, we discuss energy-aware cost-saving strategies based on reordering the HPC job schedule. Using historical job and power data, we present a hypothetical job schedule reordering that: (1) reduces the facility's peak power draw and (2) manages power in conjunction with a large-scale photovoltaic array. Lastly, we leverage this data to understand the practical limits on predicting key power use metrics at the time of submission.

97 MATHEMATICS AND COMPUTING↗

Characteristics of the Department of Energy's Building Inventory 2005-2010

The Pacific Northwest National Laboratory (PNNL) as part of their on-going support to the Department of Energy's Federal Energy Management Program (FEMP) was asked to analyze special building data for an agency to gain a better understanding of the portfolio characteristics to help better shape implementation of their alternative financing activities. This report provides information for one agency, Department of Energy (DOE), and how those characteristics have changed over time.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Performance Evaluation of Hierarchical Controls for Advanced Distribution Management System-Centered Grid Operations: Preprint

This paper presents a hardware-in-the-loop (HIL) platform to evaluate the performance of voltage regulation using an advanced distribution management system (ADMS) for grid operations to control legacy and grid-edge voltage control devices and coordinate with distributed energy management systems (DERMS) to manage high penetrations of photovoltaics (PV) on a utility distribution system. The HIL platform provides realistic laboratory testing, including accurate modeling (legacy devices, grid-edge devices, and PV) of the real-world distribution system from a utility partner, a real controller (ADMS), software controller DERMS, hardware grid-edge devices, and standard communications protocols. The test results show proper functionalities of the integrated platform and the performance of voltage regulation of the coordinated control systems. Based on laboratory testing, the utility can set up the same grid-automation system to manage DERs, legacy devices, and grid-edge devices to achieve their system-level control and operation objectives (e.g., voltage regulation), thus de-risking potential issues (e.g., instability) for field deployment.

ADMS↗

Emulation and detection of physical faults and cyber-attacks on building energy systems through real-time hardware-in-the-loop experiments

The increasing use of remote or mobile access, integrated wearable technologies, data exchange, and cloud-based data analytics in modern smart buildings is steering the building industry towards open communication technologies. The increased connectivity and accessibility could lead to more cyber-attacks in smart buildings. On the other hand, physical faults (e.g., HVAC -heating, ventilation, and air-conditioning faults) may have similar adverse impacts as those from the cyber-attacks on building energy systems, such as occupant discomfort, energy wastage, and equipment downtime. However, current physical behavior-based anomaly detection methods fail to differentiate between cyber-attacks and physical faults in building energy systems. Moreover, the challenge in collecting real-world threat data with ground truth has led researchers to rely on numerical models with user-defined assumptions, which may not accurately reflect real-world conditions due to the lack of in-situ experimental datasets. To address these challenges and gaps, this paper presents a flexible hardware-in-the-loop (HIL) testbed for generating cyber-attack and physical fault datasets and demonstrating threat detection algorithms in a real building automation system (BAS) environment. This testbed combines hardware (i.e., real BAS with local HVAC controllers and a physical network) with software (i.e., high-fidelity models to represent behaviors of building envelope and HVAC energy systems), enabling emulations of realistic threats. Five HIL experiments, including one baseline without any threats, two with physical faults, and two with cyber-attacks, were conducted to generate datasets containing detailed network traffic and system states. A joint classification framework, incorporating a network analyzer and a physical HVAC fault detector, was proposed to automatically detect cyber-physical abnormalities on BAS at both the network and the physical HVAC levels. The network analyzer comprises a conditional random fields (CRF) based command validator and a statistics-based detection strategy. The fault detector employs a weather and schedule-based pattern matching and feature-based principal component analysis (WPM-FPCA) method. Evaluation of the classification using four metrics from the multi-class confusion matrix revealed an average accuracy of 90.2%, recall of 89.7%, precision of 88.5% and F1-score of 89.2%. Finally, these results demonstrate that the proposed joint classification framework can effectively differentiate between specific types of cyber-attacks (e.g., device reinitialization attack, network Denial-of-Service attack) and physical faults (e.g., air handling unit operational fault, cooling coil valve stuck) in real time for improved building energy management.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Smart building management vs. intuitive human control—Lessons learnt from an office building in Hungary

We report that smart building management and control are adopted nowadays to achieve zero-net energy use in buildings. However, without considering the human dimension, technologies alone do not necessarily guarantee high performance in buildings. An office building was designed and built according to state-of-the-art design and energy management principles in 2008. Despite the expectations of high performance, the owner was facing high utility bills and low user comfort in the building located in Budapest, Hungary. The objective of the project was to evaluate the energy performance and comfort indices of the building, to identify the causes of malfunction and to elaborate a comprehensive energy concept. Firstly, current building conditions and operation parameters were evaluated. Our investigation found that the state-of-the-art building management system was in good conditions but it was operated by building operators and occupants who are not aware of the building management practice. The energy consumption patterns of the building were simulated with energy modelling software. The baseline model was calibrated to annual measured energy consumption, using actual occupant behaviour and presence, based on results of self-reported surveys, occupancy sensors and fan-coil usage data. Realistic occupant behaviour models can capture diversity of occupant behaviour and better represent the real energy use of the building. This way our findings and the effect of our proposed improvements could be more reliable. As part of our final comprehensive energy concept, we proposed intervention measures that would increase indoor thermal comfort and decrease energy consumption of the building. A parametric study was carried out to evaluate and quantify energy, comfort and return on investment of each measure. It was found that in the best case the building could save 23% of annual energy use. Lastly, future work includes the follow-up of: occupant reactions to intervention measures, the realized energy savings, the measurement of occupant satisfaction and behavioural changes.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Using Dashboards to Improve Energy and Comfort in Federal Buildings

Federal agencies are taking many steps to improve the sustainability of their operations, including improving the energy efficiency of their buildings, promoting recycling and reuse of materials, encouraging carpooling and alternative transit schemes, and installing low flow water fixture units are just a few of the common examples. However, an often overlooked means of energy savings is to provide feedback to building users about their energy use through information dashboards connected to a building?s energy information system. An Energy Information System (EIS), broadly defined, is a package of performance monitoring software, data acquisition hardware, and communication systems that is used to collect, store, analyze, and display energy information. At a minimum, the EIS provides the whole-building energy-use information (Granderson 2009a). We define a ?dashboard? as a display and visualization tool that utilizes the EIS data and technology to provide critical information to users. This information can lead to actions resulting in energy savings, comfort improvements, efficient operations, and more. The tools to report analyzed information have existed in the information technology as business intelligence (Few 2006). The dashboard is distinguished from the EIS as a whole, which includes additional hardware and software components to collect and storage data, and analysis for resources and energy management (Granderson 2009b). EIS can be used for a variety of uses, including benchmarking, base-lining, anomaly detection, off-hours energy use evaluation, load shape optimization, energy rate analysis, retrofit and retro-commissioning savings (Granderson 2009a). The use of these EIS features depends on the specific users. For example, federal and other building managers may use anomaly detection to identify energy waste in a specific building, or to benchmark energy use in similar buildings to identify energy saving potential and reduce operational cost. There are several vendors of EIS technology that provide information on energy and other environmental variables in buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Improved Air-Conditioning Demand Response of Connected Communities over Individually Optimized Buildings

Connected communities potentially offer much greater demand response capabilities over singular building energy management systems (BEMS) through an increase of connectivity. The potential increase in benefits from this next step in connectivity is still under investigation, especially when applied to existing buildings. This work utilizes EnergyPlus simulation results on eight different commercial prototype buildings to estimate the potential savings on peak demand and energy costs using a mixed-integer linear programming model. This model is used in two cases: a fully connected community and eight separate buildings with BEMS. The connected community is optimized using all zones as variables, while the individual buildings are optimized separately and then aggregated. These optimization problems are run for a range of individual zone flexibility values. The results indicate that a connected community offered 60.0% and 24.8% more peak demand savings for low and high flexibility scenarios, relative to individually optimized buildings. Energy cost optimization results show only marginally better savings of 2.9% and 6.1% for low and high flexibility, respectively.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

New Lighting Technologies Demonstrated at Defense Commissaries

New and emerging lighting technologies, such as LEDs, can improve lighting quality while reducing maintenance and energy costs. The Defense Commissary Agency, with support from the Department of Energy's Federal Energy Management Program and the Pacific Northwest National Laboratory, demonstrsted the use of LED lighting in a large freezer storage room and fiber optic lighting in a series of verticial reach-in display freezer cases at the Fort George G. Meade Commissary. The LEDs resulted in an 85% reduction in lighting energy and a reduction in maintenance requirements. The fiber optic lighting system resulted in a 56% reduction in lighting energy.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

New Lighting Technologies Demonstrated at Defense Commissaries

New and emerging lighting technologies, such as LEDs, can improve lighting quality while reducing maintenance and energy costs. The Defense Commissary Agency, with support from the Department of Energy's Federal Energy Management Program and the Pacific Northwest National Laboratory, demonstrsted the use of LED lighting in a large freezer storage room and fiber optic lighting in a series of verticial reach-in display freezer cases at the Fort George G. Meade Commissary. The LEDs resulted in an 85% reduction in lighting energy and a reduction in maintenance requirements. The fiber optic lighting system resulted in a 56% reduction in lighting energy.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Laboratory Testing of Demand-Response Enabled Household Appliances

With the advent of the Advanced Metering Infrastructure (AMI) systems capable of two-way communications between the utility's grid and the building, there has been significant effort in the Automated Home Energy Management (AHEM) industry to develop capabilities that allow residential building systems to respond to utility demand events by temporarily reducing their electricity usage. Major appliance manufacturers are following suit by developing Home Area Network (HAN)-tied appliance suites that can take signals from the home's 'smart meter,' a.k.a. AMI meter, and adjust their run cycles accordingly. There are numerous strategies that can be employed by household appliances to respond to demand-side management opportunities, and they could result in substantial reductions in electricity bills for the residents depending on the pricing structures used by the utilities to incent these types of responses.The first step to quantifying these end effects is to test these systems and their responses in simulated demand-response (DR) conditions while monitoring energy use and overall system performance.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Laboratory Testing of Demand-Response Enabled Household Appliances

With the advent of the Advanced Metering Infrastructure (AMI) systems capable of two-way communications between the utility's grid and the building, there has been significant effort in the Automated Home Energy Management (AHEM) industry to develop capabilities that allow residential building systems to respond to utility demand events by temporarily reducing their electricity usage. Major appliance manufacturers are following suit by developing Home Area Network (HAN)-tied appliance suites that can take signals from the home's 'smart meter,' a.k.a. AMI meter, and adjust their run cycles accordingly. There are numerous strategies that can be employed by household appliances to respond to demand-side management opportunities, and they could result in substantial reductions in electricity bills for the residents depending on the pricing structures used by the utilities to incent these types of responses. The first step to quantifying these end effects is to test these systems and their responses in simulated demand-response (DR) conditions while monitoring energy use and overall system performance.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Fresh Look at Weather Impact on Peak Electricity Demand and Energy Use of Buildings Using 30-Year Actual Weather Data

Buildings consume more than one third of the world?s total primary energy. Weather plays a unique and significant role as it directly affects the thermal loads and thus energy performance of buildings. The traditional simulated energy performance using Typical Meteorological Year (TMY) weather data represents the building performance for a typical year, but not necessarily the average or typical long-term performance as buildings with different energy systems and designs respond differently to weather changes. Furthermore, the single-year TMY simulations do not provide a range of results that capture yearly variations due to changing weather, which is important for building energy management, and for performing risk assessments of energy efficiency investments. This paper employs large-scale building simulation (a total of 3162 runs) to study the weather impact on peak electricity demand and energy use with the 30-year (1980 to 2009) Actual Meteorological Year (AMY) weather data for three types of office buildings at two design efficiency levels, across all 17 ASHRAE climate zones. The simulated results using the AMY data are compared to those from the TMY3 data to determine and analyze the differences. Besides further demonstration, as done by other studies, that actual weather has a significant impact on both the peak electricity demand and energy use of buildings, the main findings from the current study include: 1) annual weather variation has a greater impact on the peak electricity demand than it does on energy use in buildings; 2) the simulated energy use using the TMY3 weather data is not necessarily representative of the average energy use over a long period, and the TMY3 results can be significantly higher or lower than those from the AMY data; 3) the weather impact is greater for buildings in colder climates than warmer climates; 4) the weather impact on the medium-sized office building was the greatest, followed by the large office and then the small office; and 5) simulated energy savings and peak demand reduction by energy conservation measures using the TMY3 weather data can be significantly underestimated or overestimated. It is crucial to run multi-decade simulations with AMY weather data to fully assess the impact of weather on the long-term performance of buildings, and to evaluate the energy savings potential of energy conservation measures for new and existing buildings from a life cycle perspective.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Non-routine adjustments – towards standardizing M&V approach for quantifying the effects of static factors

The success of an energy management program relies on ensuring that the energy savings can be verified with an adequate level of certainty. Energy savings cannot be directly measured and hence have to be deduced by comparing the pre-retrofit energy consumption with post-retrofit energy consumption data adjusted to account for differences in conditions. These adjustments are needed, since conditions that influence energy consumption may not stay the same between pre- and postinstallation phase of the project. These adjustments can often be routine when accounting for factors like production volume and weather that are expected to change and are included in the energy consumption adjustment model. Existing measurement and verification (M&V) resources and guidance mostly concentrate on developing models for routine adjustment of one or more factors that normally change. On the other hand, there are factors (static) like product mix, operating hours, gross square area, etc. that are assumed to stay constant during normal conditions. However, in order to adapt to dynamic market conditions, the industries are forced to react thereby leading to changes to these static factors. Identifying these static factors that warrant adjustment, called non-routine event, along with quantifying their effect on energy consumption can be complex and lack of proper guidance can exacerbate this issue. This paper reviews some of the current work in terms of how non-routine events are defined, characterized, detected and quantified based on a review of existing M&V guidelines, protocols and other relevant literature. This work also reviewed some of the existing non-routine events and adjustment practices to understand how these different aspects are addressed along with a discussion on some of the key challenges and gaps in the current guidance.

Earni, Shankar↗