Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “EYES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 883 records · Page 49

Effects of Dietary Iron and Gamma Radiation on the Rat Retina

A health risk of concern for NASA relates to radiation exposure and its synergistic effects with other space environmental factors, includi ng nutritional status of the crew. Astronauts consume almost three times the recommended daily allowance of iron due to the use of fortifie d foods aboard the International Space Station, with iron intake occa sionally exceeding six times the recommended values. Recently, NASA has become concerned with visual changes associated with spaceflight, a nd research is being conducted to elucidate the etiology of eye structure alterations in the spaceflight environment. Terrestrially, iron o verload is also associated with certain optic neuropathies. In additi on, due to its role in Fenton reactions, iron can potentiate oxidative stress, which is a recognized cause of cataract formation. As part o f a study investigating the combined effects of radiation exposure an d iron overload on multiple physiological systems, we focused on defining the effects of both treatments on eye biology. In this study, 12- week-old Sprague-Dawley rats were assigned to one of four experimental groups: normal iron/no radiation (Control/Sham), high iron/no radiat ion (Fe/Sham), normal iron/gamma radiation (3 Gy cumulative dose, fra ctionated at 0.375 Gy/d every other day for 16 d) (Control/Rad), and high iron/gamma radiation (Fe/Rad). Oxidative stress-induced DNA damag e, measured as concentration of the marker 8-hydroxy-2'-deoxyguanosine (8OHdG) in eye retinal tissue by enzyme-immunoanalysis did not show significant changes among treatments. However, there was an overall i ncrease in 8OHdG immunostaining density in retina sections due to radiation exposure (P = 0.05). Increased dietary iron and radiation expos ure had an interactive effect (P = 0.02) on 8OHdG immunostaining of t he retinal ganglion cell layer with iron diet increasing the signal in the group not exposed to radiation (P = 0.05). qPCR gene expression profiling of relevant target genes indicated upregulation of ferritin light chain (P = 0.09) as a result of dietary iron but no change in e xpression of the gene for ferritin heavy chain. Immunolocalization of light chain and heavy chain of the iron storage protein ferritin showed the expected distribution in the choroid, photoreceptor layer, inn er nuclear layer and in the inner plexiform layer that corresponded t o the synaptic terminals of bipolar cells. Evidence of stress and damage in the retina was also suggested by a decrease in expression of th e survival marker Bcl2 (P = 0.01) and the protective proteins clusterin (P = 0.04) and heat shock factor 1 (Hsf1, P < 0.001), as a result o f increased dietary iron. The effect of increased iron on expression of the antioxidant enzyme heme oxygenase 1 (Hmox1) had a significant interaction with the effect of radiation (P < 0.001). In summary, the results of this study indicate that both gamma radiation exposure and a moderate increase in dietary iron can contribute to deleterious cha nges in retinal health and physiology.

Morgan, Jennifer↗

Support Routines for In Situ Image Processing

This software consists of a set of application programs that support ground-based image processing for in situ missions. These programs represent a collection of utility routines that perform miscellaneous functions in the context of the ground data system. Each one fulfills some specific need as determined via operational experience. The most unique aspect to these programs is that they are integrated into the large, in situ image processing system via the PIG (Planetary Image Geometry) library. They work directly with space in situ data, understanding the appropriate image meta-data fields and updating them properly. The programs themselves are completely multimission; all mission dependencies are handled by PIG. This suite of programs consists of: (1)marscahv: Generates a linearized, epi-polar aligned image given a stereo pair of images. These images are optimized for 1-D stereo correlations, (2) marscheckcm: Compares the camera model in an image label with one derived via kinematics modeling on the ground, (3) marschkovl: Checks the overlaps between a list of images in order to determine which might be stereo pairs. This is useful for non-traditional stereo images like long-baseline or those from an articulating arm camera, (4) marscoordtrans: Translates mosaic coordinates from one form into another, (5) marsdispcompare: Checks a Left Right stereo disparity image against a Right Left disparity image to ensure they are consistent with each other, (6) marsdispwarp: Takes one image of a stereo pair and warps it through a disparity map to create a synthetic opposite- eye image. For example, a right eye image could be transformed to look like it was taken from the left eye via this program, (7) marsfidfinder: Finds fiducial markers in an image by projecting their approximate location and then using correlation to locate the markers to subpixel accuracy. These fiducial markets are small targets attached to the spacecraft surface. This helps verify, or improve, the pointing of in situ cameras, (8) marsinvrange: Inverse of marsrange . given a range file, re-computes an XYZ file that closely matches the original. . marsproj: Projects an XYZ coordinate through the camera model, and reports the line/sample coordinates of the point in the image, (9) marsprojfid: Given the output of marsfidfinder, projects the XYZ locations and compares them to the found locations, creating a report showing the fiducial errors in each image. marsrad: Radiometrically corrects an image, (10) marsrelabel: Updates coordinate system or camera model labels in an image, (11) marstiexyz: Given a stereo pair, allows the user to interactively pick a point in each image and reports the XYZ value corresponding to that pair of locations. marsunmosaic: Extracts a single frame from a mosaic, which will be created such that it could have been an input to the original mosaic. Useful for creating simulated input frames using different camera models than the original mosaic used, and (12) merinverter: Uses an inverse lookup table to convert 8-bit telemetered data to its 12-bit original form. Can be used in other missions despite the name.

Deen, Robert G.↗

Optic Nerve Sheath Mechanics and Permeability in VIIP Syndrome

Long-duration space flight carries the risk of developing Visual Impairment and Intracranial Pressure (VIIP) syndrome, a spectrum of ophthalmic changes including posterior globe flattening, choroidal folds, distension of the optic nerve sheath (ONS), optic nerve kinking and potentially permanent degradation of visual function. The slow onset of VIIP, its chronic nature, and certain clinical features strongly suggest that biomechanical factors acting on the ONS play a role in VIIP. Here we measure several relevant ONS properties needed to model VIIP biomechanics. The ONS (meninges) of fresh porcine eyes (n7) was reflected, the nerve proper was truncated near the sclera, and the meninges were repositioned to create a hollow cylinder of meningeal connective tissue attached to the posterior sclera. The distal end was cannulated, sealed, and pressure clamped (mimicking cerebrospinal fluid [CSF] pressure), while the eye was also cannulated for independent control of intraocular pressure (IOP). The meninges were inflated (CSF pressure cycling 7-50 mmHg) while ONS outer diameter was imaged. In another set of experiments (n4), fluid permeation rate across the meninges was recorded by observing the drainage of an elevated fluid reservoir (30 mmHg) connected to the meninges. The ONS showed behavior typical of soft tissues: viscoelasticity, with hysteresis in early preconditioning cycles and repeatable behavior after 4 cycles, and nonlinear stiffening, particularly at CSF pressures 15 mmHg (Figure). Tangent moduli measured from the loading curve were 372 101, 1199 358, and 2050 379 kPa (mean SEM) at CSF pressures of 7, 15 and 30 mmHg, respectively. Flow rate measurements through the intact meninges at 30mmHg gave a permeability of 1.34 0.46 lmincm2mmHg (mean SEM). The ONS is a tough, strain-stiffening connective tissue that is surprisingly permeable. The latter observation suggests that there could be significant CSF drainage through the ONS into the orbit, likely important for CSF transport in the optic nerve. These experimental measurements, extended to human eyes, are informing computational models of the pathophysiology and biomechanics of the ONS in VIIP syndrome.

biomechanics↗

Biomechanics of the Optic Nerve Sheath in VIIP Syndrome

Long-duration space flight carries the risk of developing Visual Impairment and Intracranial Pressure (VIIP) syndrome, a spectrum of ophthalmic changes including posterior globe flattening, choroidal folds, distension of the optic nerve sheath (ONS), optic nerve kinking and potentially permanent degradation of visual function. The slow onset of VIIP, its chronic nature, and certain clinical features strongly suggest that biomechanical factors acting on the ONS play a role in VIIP. Here we measure several relevant ONS properties needed to model VIIP biomechanics. The ONS (meninges) of fresh porcine eyes (n7) was reflected, the nerve proper was truncated near the sclera, and the meninges were repositioned to create a hollow cylinder of meningeal connective tissue attached to the posterior sclera. The distal end was cannulated, sealed, and pressure clamped (mimicking cerebrospinal fluid [CSF] pressure), while the eye was also cannulated for independent control of intraocular pressure (IOP). The meninges were inflated (CSF pressure cycling 7-50 mmHg) while ONS outer diameter was imaged. In another set of experiments (n4), fluid permeation rate across the meninges was recorded by observing the drainage of an elevated fluid reservoir (30 mmHg) connected to the meninges. The ONS showed behavior typical of soft tissues: viscoelasticity, with hysteresis in early preconditioning cycles and repeatable behavior after 4 cycles, and nonlinear stiffening, particularly at CSF pressures 15 mmHg (Figure). Tangent moduli measured from the loading curve were 372 101, 1199 358, and 2050 379 kPa (mean SEM) at CSF pressures of 7, 15 and 30 mmHg, respectively. Flow rate measurements through the intact meninges at 30mmHg gave a permeability of 1.34 0.46 lmincm2mmHg (mean SEM). The ONS is a tough, strain-stiffening connective tissue that is surprisingly permeable. The latter observation suggests that there could be significant CSF drainage through the ONS into the orbit, likely important for CSF transport in the optic nerve. These experimental measurements, extended to human eyes, are informing computational models of the pathophysiology and biomechanics of the ONS in VIIP syndrome.

fluid shifts↗

Probabilistic Modeling Of Ocular Biomechanics In VIIP: Risk Stratification

Visual Impairment and Intracranial Pressure (VIIP) syndrome is a major health concern for long-duration space missions. Currently, it is thought that a cephalad fluid shift in microgravity causes elevated intracranial pressure (ICP) that is transmitted along the optic nerve sheath (ONS). We hypothesize that this in turn leads to alteration and remodeling of connective tissue in the posterior eye which impacts vision. Finite element (FE) analysis is a powerful tool for examining the effects of mechanical loads in complex geometries. Our goal is to build a FE analysis framework to understand the response of the lamina cribrosa and optic nerve head to elevations in ICP in VIIP. To simulate the effects of different pressures on tissues in the posterior eye, we developed a geometric model of the posterior eye and optic nerve sheath and used a Latin hypercubepartial rank correlation coef-ficient (LHSPRCC) approach to assess the influence of uncertainty in our input parameters (i.e. pressures and material properties) on the peak strains within the retina, lamina cribrosa and optic nerve. The LHSPRCC approach was repeated for three relevant ICP ranges, corresponding to upright and supine posture on earth, and microgravity [1]. At each ICP condition we used intraocular pressure (IOP) and mean arterial pressure (MAP) measurements of in-flight astronauts provided by Lifetime Surveillance of Astronaut Health Program, NASA Johnson Space Center. The lamina cribrosa, optic nerve, retinal vessel and retina were modeled as linear-elastic materials, while other tissues were modeled as a Mooney-Rivlin solid (representing ground substance, stiffness parameter c1) with embedded collagen fibers (stiffness parameters c3, c4 and c5). Geometry creationmesh generation was done in Gmsh [2], while FEBio was used for all FE simulations [3]. The LHSPRCC approach resulted in correlation coefficients in the range of 1. To assess the relative influence of the uncertainty in an input parameter on the peak strains, we ranked and then normalized these coefficients, considering that normalized values 0.5 implied a substantial influence on the range of the peak strains in the optic nerve head (ONH). IOP and ICP were found to have a major influence on the peak strains in the ONH, as did optic nerve and LC stiffness. Interestingly, the stiffness of the sclera far from the scleral canal did not have a large influence on peak strains in ONH tissues; however, the collagen fiber stiffness in the peripapillary sclera and annular ring both influenced the peak strains within the ONH. We have created a physiologically relevant model that incorporated collagen fibers to study the effects of elevated ICP. Elevated ICP resulted in strains in the optic nerve that are not predicted to occur on earth: the upright or supine conditions. We found that IOP, ICP, lamina cribrosa stiffness and optic nerve stiffness had the highest association with these extreme strains in the ONH. These extreme strains may activate mechanosensitive cells that induce tissue remodeling and are a risk factor for the development of VIIP.

biomechanics↗

Validation of a Manually Oscillating Chair for In-The-Field Assessment of Dynamic Visual Acuity on Crewmembers Within Hours of Returning From Long-Duration Spaceflight

Long-duration spaceflight results in sensorimotor adaptations, which cause functional deficits during gravitational transitions, such as landing on a planetary surface after long-duration microgravity exposure. Both the vestibular system and the central nervous system are affected by gravitational transitions. These systems are responsible for coordinating head and eye movements via the vestibulo-ocular reflex (VOR) and go through an adaptation period upon exposure to microgravity. Consequently, they must also re-adapt to Earth's gravitational environment upon landing. This re-adaptation causes decrements in gaze control and dynamic visual acuity, with crewmembers reporting oscillopsia and blurred vision caused by retinal slip, or the inability to keep an image focused on their retina. This is thought to drive motion sickness symptoms experienced by most crewmembers following landing. Retinal slip can be estimated by dynamic visual acuity (DVA); visual acuity while in motion. Previously, DVA has been assessed in the laboratory where subjects walked at 6.4 km/hr on a motorized treadmill. Using this method, Peters et al. (2011) found that DVA is worsened in astronauts by an average of 0.75 eye-chart lines one day after landing. However, it is believed that re-adaptation occurs quickly and that DVA might be worse immediately upon re-exposure to a gravitational environment. Since many crewmembers are unable to walk safely upon landing, it was necessary to develop a method for replicating the vertical head movements associated with walking. In addition, the use of a chair to imitate the head displacement caused by walking isolates eye-head interactions without allowing for trunk and lower-body compensation, as seen with treadmill walking (Mulavara & Bloomberg 2003). Therefore, a modality for assessing DVA in the field within a few hours of landing was developed. In this study, we validated the ability of a manually operated oscillating chair to reproduce the oscillatory frequency of walking on a treadmill. Healthy non-astronaut subjects (n=14) participated in one test session and completed three static (seated) and three dynamic (walking/oscillated) visual acuity tests. DVA was assessed using a motorized treadmill, an automated oscillating chair, and a manually operated chair, both developed in the Neuroscience Laboratory at JSC. The automated chair was motor-driven and set to oscillate vertically at 2 Hz with a vertical displacement of +/- 5 cm to simulate vertical translation while walking. The manually operated chair was oscillated vertically by a test operator to the beat of a metronome at 120 beats/min (2 Hz) and a vertical displacement of approximately +/- 5 cm. As the subject was oscillated, they were asked to discern the direction gap of Landolt-C optotypes of varying sizes and verbally reported the direction while an operator recorded their response using a gamepad. Subjects were outfitted with accelerometers (sampling rate = 128 Hz) on their head, trunk and lumbar spine. A fast Fourier transform was performed on the vertical trunk acceleration to compare the peak and spread of the distribution of oscillation frequencies for each oscillating condition. The spread of the frequency distribution for the manual chair was not significantly different from either the treadmill or the automated chair. However, all three conditions had similar non-zero standard error values, suggesting a variance in head movement frequency which may affect DVA. The average oscillation frequency of the manual chair (1.85 Hz) was significantly different (α=0.05) from that of treadmill walking (2.24 Hz), but not significantly different from that of the automated chair (1.85 Hz) and all three conditions had small standard errors (SEM = 0.04, 0.06, and 0.08 Hz for manual, treadmill, and automated respectively). This implies that both chairs oscillate at a frequency below that of treadmill walking, but are comparable to each other and reproducible across sessions. Additionally, DVA scores did not vary significantly across conditions. The smaller spread values of the oscillating chairs' frequencies indicated mitigation of variation induced by locomotor strategies, which enables better examination of the issue of VOR adaptation. Furthermore, due to the deconditioned state of crewmembers in the initial hours after landing, it is easier to transport a manual bouncing chair into the field and safer to perform a vision test while seated in a chair versus walking on a treadmill. Therefore, the manually oscillating chair has been deemed to meet and exceed the DVA testing capabilities previously obtained by treadmill walking.

Kreutzberg, G. A.↗

Comprehensive Oculomotor Behavioral Response Assessment (COBRA)

An eye movement-based methodology and assessment tool may be used to quantify many aspects of human dynamic visual processing using a relatively simple and short oculomotor task, noninvasive video-based eye tracking, and validated oculometric analysis techniques. By examining the eye movement responses to a task including a radially-organized appropriately randomized sequence of Rashbass-like step-ramp pursuit-tracking trials, distinct performance measurements may be generated that may be associated with, for example, pursuit initiation (e.g., latency and open-loop pursuit acceleration), steady-state tracking (e.g., gain, catch-up saccade amplitude, and the proportion of the steady-state response consisting of smooth movement), direction tuning (e.g., oblique effect amplitude, horizontal-vertical asymmetry, and direction noise), and speed tuning (e.g., speed responsiveness and noise). This quantitative approach may provide fast and results (e.g., a multi-dimensional set of oculometrics and a single scalar impairment index) that can be interpreted by one without a high degree of scientific sophistication or extensive training.

Stone, Leland S.↗

Biomimetic Optical Sensor for Real-Time Aircraft Wing Deflection Measurement

Reducing the environmental impact of aviation is a primary goal of NASA aeronautics research. One approach to achieve this goal is to build lighter weight aircraft, which presents complex challenges due to a corresponding increase in structural flexibility. Wing flexibility can adversely affect aircraft performance from the perspective of aerodynamic efficiency and safety. Knowledge of the wing position during flight can aid active control methods designed to mitigate problems due to increased wing flexibility. Current approaches to measuring wing deflection, including strain measurement devices, accelerometers, or GPS solutions, and new technologies such as fiber optic strain sensors, have limitations for their practical application to flexible aircraft control. Hence, it was proposed to use a bio-mimetic optical sensor based on the fly-eye to track wing deflection in real-time. The fly-eye sensor has several advantages over conventional sensors used for this application, including light weight, low power requirements, fast computation, and a small form factor. This paper reports on the fly-eye sensor development and its application to real-time wing deflection measurement.

Frost, Susan A.↗

Small target detection for search and rescue operations using distributed deep learning and synthetic data generation

It is important to find the target as soon as possible for search and rescue operations. Surveillance camera systems and unmanned aerial vehicles (UAVs) are used to support search and rescue. Automatic object detection is important because a person cannot monitor multiple surveillance screens simultaneously for 24 hours. Also, the object is often too small to be recognized by the human eye on the surveillance screen. This study used UAVs around the Port of Houston and fixed surveillance cameras to build an automatic target detection system that supports the US Coast Guard (USCG) to help find targets (e.g., person overboard). We combined image segmentation, enhancement, and convolution neural networks to reduce detection time to detect small targets. We compared the performance between the auto-detection system and the human eye. Our system detected the target within 8 seconds, but the human eye detected the target within 25 seconds. Our systems also used synthetic data generation and data augmentation techniques to improve target detection accuracy. This solution may help the search and rescue operations of the first responders in a timely manner.

Chow, Edward↗

Neuro-Vestibular Examination During and Following Spaceflight (Vestibular Health)

BACKGROUND Adaptation to microgravity during spaceflight causes neurological disturbances that are either directly or indirectly mediated by the vestibular system. These disturbances could include space motion sickness, spatial disorientation, and cognitive impairment, as well as changes in head-eye coordination, vestibulo-ocular reflexes, and control of posture and locomotion. Otolith-mediated reflex gains appear to adapt rapidly during spaceflight and after landing. However, animal studies have shown that structural modifications of the vestibular sensory apparatus develop during long-duration spaceflight. To date, no studies have characterized the severity of vestibular syndromes experienced by astronauts as a function of the duration of spaceflight or whether the effects are caused by changes at the peripheral end organs, midbrain, cerebellum, or vestibular cortex. OBJECTIVES We will investigate temporal vestibular changes in crewmembers of short, 6-month, and one-year missions to identify trends in adaptation of vestibular health and performance in orbit and after landing. We will also determine whether the vestibular organs and/or the central vestibular system undergo structural changes during long-duration exposure to microgravity, which could cause vestibular disorders when transitioning to a different gravitational environment. METHODS Recordings of eye, head, and body movements, as well as subjective reports of perception of motion, will be used to determine the presence of abnormal eye movements, dysmetria, motion sickness symptoms, and illusions of motion during head or body movements. This includes characterization of temporal trends in central compensation for vestibular (otolith) asymmetry. Pre-flight data will be collected 90 days before the flight. In-flight tests will be performed early in the mission and once every one or two months thereafter. Post-flight examinations will be performed on the following days after return (R) from the mission: R+0, R+4, R+9, and R+30. Ground-based control tests will be performed on healthy volunteers in the laboratory to estimate mean normative responses. CONTROL RESULTS Thirty-two healthy (non-astronaut) control subjects performed the same ground test procedures as planned for crewmembers. In addition to establishing a normative database, these data were used to calculate vestibular asymmetries from perceptual reports during unilateral centrifugation, oculomotor responses during visual-alignment tasks, vestibulo-ocular reflex gain during head-impulse tests, and body rotation during stepping tests. A significant correlation was observed between asymmetries of subjective visual vertical and verbal report during unilateral centrifugation. Another significant correlation was observed between the asymmetries of ocular alignment, vestibulo-ocular reflex gain, and body rotation. These findings in a healthy cohort may help us better understand changes in vestibular asymmetries in crewmembers during and following spaceflight. RELEVANCE If the observed symptoms in crewmembers are more deleterious after the year-long missions than those documented after 6-month missions, then relevant countermeasures will be required to maintain the health and operational performance of astronauts during longer missions. Depending on the etiology of the vestibular syndrome revealed by these tests, countermeasures will be proposed based on vestibular rehabilitation therapies currently used in patients with vestibular disorders, such as habituation, gaze stabilization, and/or balance training exercises. ACKNOWLEDGEMENT This work is supported by the NASA’s Human Research Program Human Health Countermeasures Element.

T R Macaulay↗

Histological and Transcriptomic Analysis of Spaceflight-Induced Ocular Changes in the Mouse Retina

Anatomical changes have been observed in astronauts’ eyes after long duration spaceflight missions. These alterations can lead to visual impairment which in part constitutes the spaceflight-associated neuroocular syndrome (SANS), one of the top risk priorities for deep space missions. The HRP Systems Biology (SysBio) Translation Project will apply systems biology approaches utilizing current human physiological spaceflight data, molecular results from rodents, and future research with a multi-level, multi-system, and multi-species perspective to augment the existing research plan to resolve the SANS risk. Not much is known about SANS at the cellular and molecular level, but studies in mice and rats have recently begun to determine how spaceflight might affect the biology of the eye. Preliminary studies of mice that flew on the Space Shuttle, and more recently the International Space Station (ISS), have shown changes in retinal physiology as assessed by histology and gene expression analysis. The study presented here obtained samples from the CASIS sponsored Rodent Research 8 Experiment delivered to the ISS by SpaceX CRS-16 on 12/08/2018. Female BALB/cAnNTac mice flew on the ISS for 45 days, while ground controls were housed in a standard vivarium or animal enclosure module. Sacrifice and sample acquisition occurred once mice returned to Earth, possibly allowing for readaptation affecting retinal homeostasis. We applied standard transcriptomic (RNAseq) and histological approaches to characterize genes and pathways in the mouse retina affected by spaceflight or age. The differentially expressed gene (DEG) data was analyzed using Galaxy (GeneLab) and Ingenuity Pathway Analysis. Significant DEGs between flight and ground samples were relatively few but biologically meaningful. Pathways identified related to neuronal differentiation, cellular transport/movement, and wound healing. Age effects were detected between the young (10–12 weeks) and old (32 weeks) groups and between the baseline and end of experiment (~46 days). The biological relevance of specific DEGs were confirmed through immunohistochemical evaluation using fixed histological sections of the eye from four flight group mice and four habitat control mice. Staining was performed specific for synaptophysin, glial fibrillary acidic protein (GFAP), and neurofilament in the retinal periphery, equator, and peripapillary regions. For synaptophysin staining, the innerplexiform and outerplexiform layers were scored; for GFAP staining, Mueller cells and perivascular astrocytes were scored. Results show flight samples typically had more staining of GFAP and neurofilament while, conversely, the habitat control group had more staining of synaptophysin.

C. Perez↗

Exploration Helmet Permanent Anti-fog Study

For the current Extravehicular Mobility Unit (EMU) spacesuit, an astronaut applies an anti-fog solution to the interior of the helmet bubble before each EVA. However, the anti-fog solution has been reported to cause eye discomfort during at least seven EMU EVAs when the anti-fog solution contacted the crew member’s eyes. During STS-100, astronaut Chris Hadfield reported the eye irritation temporarily blinded him during his spacewalk. In addition, the wipe on anti-fog solution is a consumable that needs to be accounted for and a supply launched for missions. To solve this, the Exploration EMU (xEMU) pressure bubble investigated using a permanent anti-fog coating during Design Verification and Test (DVT) human in the loop (HITL) events. Chosen for previous use in Constellation Space Suit develop, HTAF-601, a water based permanent anti-fog solution, was tested. However, major issues have arisen with further HITL testing with the coating. Cleaning the helmet has been a challenge to avoid damaging the permanent anti-fog coating. NASA has completed a set of different methods for cleaning the anti-fog to try to document a preferred method. It was found isopropyl alcohol (IPA) cannot be used to clean the interior of the helmet because it will strip and delaminate the permanent anti-fog coating. Even with using a very gentle cleaning method of flushing with distilled or DI water and dabbing at facial oils, the permanent anti-fog starts to delaminate consistently after 50 hours manned pressurized time (MPT). Finally, the HTAF-601 coating is being discontinued by the vendor. Due to these issues, further investigation is being completed evaluating two solvent based anti-fog solutions: Exxene’s HCF-100 and FSI’s Visgard 106-94. Each coating will be evaluated on polycarbonate samples for application consistency, steam cycles (mimicking breath cycles), cleaning durability, haze, and light transmission. This study will determine if either coating is a viable option to pursue as a permanent anti-fog for spacesuit helmet applications.

spacesuit↗

Defining Change Thresholds: What Change Is Outside Typical Sources of Variation?

Researchers often have a difficult time defining meaningful thresholds for change. We sometimes identify subtle changes but what amount of change is beyond typical sources of variation? This is especially complicated when trying to understand new disease pathogenesis like the constellation of eye changes leading to Spaceflight-associated Neuro-ocular Syndrome (SANS). To support decision makers in defining minimal meaningful change, we used a Bayesian hierarchical model to estimate innate sources of variability such as natural day to day variation. Healthy subjects were recruited and imaged with MRI, OCT, and US on separate days and measured by several technicians. Models were developed specifying random effects for the sources of variation – between left and right eyes, within-individuals over time, between raters, and finally between individuals. This allowed us to find the posterior distribution for the total typical variation, within an eye, which we use to define a threshold where change beyond typical sources of variation is likely. This threshold is now used as our earliest indicator of systematic increase in Total Retinal Thickness (a precursor to optic disc edema).

Millennia Young↗

Exploration Helmet Permanent Anti-Fog Study

For the current Extravehicular Mobility Unit (EMU) spacesuit, an astronaut applies an antifog solution to the interior of the helmet bubble before each EVA. However, the anti-fog solution has been reported to cause eye discomfort during at least seven EMU EVAs when the anti-fog solution contacted the crew member’s eyes. During STS-100, astronaut Chris Hadfield reported the eye irritation temporarily blinded him during his spacewalk. In addition, the wipe on anti-fog solution is a consumable that needs to be accounted for and a supply launched for missions. To solve this, NASA has tested different permanent anti-fog coatings. However, major issues have arisen with Human in the Loop (HITL) testing with the coatings. Cleaning and removing Valsalva devices which use pressure sensitive adhesives have been challenges to avoid damaging the permanent anti-fog coating. Due to these issues, further investigation is being completed evaluating two solvent based anti-fog solutions: Exxene’s HCF-100 and FSI’s Visgard 106-94. Each coating will be evaluated on polycarbonate samples for application consistency, steam cycles (mimicking breath cycles), cleaning durability, haze, and light transmission. This study will determine if either coating is a viable option to pursue as a permanent anti-fog for spacesuit helmet applications.

spacesuit↗

Exploration Helmet Permanent Anti-Fog Study

For the current Extravehicular Mobility Unit (EMU) spacesuit, an astronaut applies an antifog solution to the interior of the helmet bubble before each EVA. However, the anti-fog solution has been reported to cause eye discomfort during at least seven EMU EVAs when the anti-fog solution contacted the crew member’s eyes. During STS-100, astronaut Chris Hadfield reported the eye irritation temporarily blinded him during his spacewalk. In addition, the wipe on anti-fog solution is a consumable that needs to be accounted for and a supply launched for missions. To solve this, NASA has tested different permanent anti-fog coatings. However, major issues have arisen with Human in the Loop (HITL) testing with the coatings. Cleaning and removing Valsalva devices which use pressure sensitive adhesives have been challenges to avoid damaging the permanent anti-fog coating. Due to these issues, further investigation is being completed evaluating two solvent based anti-fog solutions: Exxene’s HCF-100 and FSI’s Visgard 106-94. Each coating will be evaluated on polycarbonate samples for application consistency, steam cycles (mimicking breath cycles), cleaning durability, haze, and light transmission. This study will determine if either coating is a viable option to pursue as a permanent anti-fog for spacesuit helmet applications.

spacesuit↗

Neuro-Vestibular Examination During and Following Spaceflight (Vestibular Health)

BACKGROUND Adaptation to microgravity during spaceflight causes neurological disturbances that are either directly or indirectly mediated by the vestibular system. These disturbances can include space motion sickness, spatial disorientation, and cognitive impairment, as well as changes in head-eye coordination, vestibulo-ocular reflexes, and control of posture and locomotion. Otolith-mediated reflex gains appear to adapt rapidly during spaceflight and after landing. However, animal studies have shown that structural modifications of the vestibular sensory apparatus develop during long-duration spaceflight. To date, no studies have characterized the severity of vestibular syndromes experienced by astronauts as a function of the duration of spaceflight or whether the effects are caused by changes at the peripheral end organs, midbrain, cerebellum, or vestibular cortex. OBJECTIVES We are investigating temporal vestibular changes in crewmembers of short, 6-month, and one-year missions to identify trends in adaptation of vestibular health and performance in orbit and after landing. We are also differentiating between peripheral and central vestibular forms of vertigo and oculomotor disorders. METHODS Recordings of eye, head, and body movements, as well as subjective reports of perception of motion, are being used to determine the presence of abnormal eye movements, dysmetria, motion sickness symptoms, and illusions of motion during head or body movements. This includes characterization of temporal trends in central compensation for vestibular (otolith) asymmetry. In-flight examinations are being performed early in the mission (Flight Days 1 and 30) and once every 2-3 months thereafter. Postflight examinations are performed after return (R) from the mission on R+0, R+4, R+9, and R+30. The inflight and postflight motion sickness questionnaires are customized to support data sharing across related studies. Ground-based control testing has been performed on healthy volunteers(18 females, 14 males;38.6 ± 9.2 years) in the laboratory to estimate mean normative responses, and on patients with bilateral vestibulopathy (BVP) (17 females, 13 males; 60.6 ± 13.0 years) at the University of Caen. RESULTS As of September 2024, two crewmembers have completed all preflight, inflight, and postflight testing. Additional crewmembers are currently enrolled and data collection is currently ongoing. For ground testing, BVP patients performed similarly to previous postflight astronauts on R+0 in various walking performance tasks. Three additional body movement perception tasks have been tested. For the Triangle Completion Task, BVP patients had a larger mean angle of deviation and longer mean distance than healthy controls. For the Self-Rotation Task and Distance Perception Task, BVP patients had larger errors than healthy controls. These data suggest that vestibular deficiencies impact all aspects of body movement perception tested; whereas previous studies suggest that vestibular deficiencies are only associated with directional errors, not with overall trajectories/path lengths. These data will be compared to those of crewmembers during early postflight readaptation. RELEVANCE If the observed symptoms in crewmembers are more deleterious after the year-long missions than those documented after 6-month missions, then relevant countermeasures will be required to maintain the health and operational performance of astronauts during longer missions. Depending on the etiology of the vestibular syndrome revealed by these tests, countermeasures will be proposed based on vestibular rehabilitation therapies currently used in patients with vestibular disorders, such as habituation, gaze stabilization, and/or balance training exercises. ACKNOWLEDGEMENT This work is supported by NASA’s Human Research Program Human Health Countermeasures Element.

T R Macaulay↗

Retinal instrument

In one embodiment, the present invention provides a method of removing scar tissue from an eye that includes inserting a device including an array of micro-rods into an eye, wherein at least one glass micro-rod of the array of glass micro-rods includes a sharp feature; contacting a scar tissue with the array of micro-rods; and removing the array of micro-rods and the scar tissue from the eye. In another embodiment, the present invention provides a medical device for engaging a tissue including and an array of glass micro-rods, wherein at least one glass micro-rod of the array of glass micro-rods includes a sharp feature opposite a base of the array of glass micro-rods that is connected to the cannula, wherein the sharp feature of the at least one micro-rod is angled from a plane that is normal to a face of the base of the array of glass micro-rods.

47 OTHER INSTRUMENTATION↗

Microfabricated instruments and methods to treat recurrent corneal erosion

In one embodiment, the present invention provides a device and method for treating recurrent corneal erosion. In one embodiment, the method includes the steps of contacting an epithelium layer of a cornea with an array of glass micro-rods including a plurality of sharp features having a length that penetrates a Bowman&#x27;s layer of the eye, wherein the plurality of sharp features of the array of glass micro-rods produces a plurality of punctures in the Bowman&#x27;s layer of the eye that are of micro-scale or less. In another embodiment, the present invention provides a method and device for drug delivery. In one embodiment, the device includes an array of glass micro-rods, wherein at least one glass micro-rod of the array of glass micro-rods includes a sharp feature opposite a base of the array of glass micro-rods, wherein the sharp feature includes a treated surface for delivering a chemical compound to the eye.

60 APPLIED LIFE SCIENCES↗