Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ELECTROMAGNETIC INSTRUMENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 883 records · Page 49

Tomographic Hard X-ray Phase Contrast Micro- and Nano-imaging at TOMCAT

This article illustrates the phase contrast instrumentation installed at the Tomographic Microscopy and Coherent Radiology beamline (TOMCAT) of the Swiss Light Source. Our experimental framework has been designed to extract phase information at spatial resolutions covering three orders of magnitude. For moderate (5-10 microns) resolutions we implemented a two-gratings interferometer, operated at energies between 14 and 40 keV. For high resolution (1-5 microns) we obtain phase information thanks to a modified transport of intensity approach. For very high-resolutions (0.1-0.5 microns) we developed a broadband hard X-ray full-field microscope operated in Zernike-phase contrast.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Spacelab energetic ion mass spectrometer

Basic design criteria are given for an ion mass spectrometer for use in studying magnetospheric ion populations. The proposed instrument is composed of an electrostatic analyzer followed by a magnetic spectrometer and simultaneously measures the energy per unit and mass per unit charge of the ion species. An electromagnet is used for momentum analysis to extend the operational energy range over a much wider domain than is possible with the permanent magnets used in previous flights. The energetic ion source regions, ion energization mechanisms, field line tracing, coordinated investigations, and orbit considerations are discussed and operations of the momentum analyzer and of the electrostatic energy analyzer are examined.

Whalen, B. A.↗

Electromagnetic Waves and Bursty Electron Acceleration: Implications from Freja

Dispersive Alfven wave activity is identified in four dayside auroral oval events measured by the Freja satellite. The events are characterized by ion injection, bursty electron precipitation below about I keV, transverse ion heating and broadband extremely low frequency (ELF) emissions below the lower hybrid cutoff frequency (a few kHz). The broadband emissions are observed to become more electrostatic towards higher frequencies. Large-scale density depletions/cavities, as determined by the Langmuir probe measurements, and strong electrostatic emissions are often observed simultaneously. A correlation study has been carried out between the E- and B-field fluctuations below 64 Hz (the dc instrument's upper threshold) and the characteristics of the precipitating electrons. This study revealed that the energization of electrons is indeed related to the broadband ELF emissions and that the electrostatic component plays a predominant role during very active magnetospheric conditions. Furthermore, the effect of the ELF electromagnetic emissions on the larger scale field-aligned current systems has been investigated, and it is found that such an effect cannot be detected. Instead, the Alfvenic activity creates a local region of field-aligned currents. It is suggested that dispersive Alfven waves set up these local field-aligned current regions and in turn trigger more electrostatic emissions during certain conditions. In these regions ions are transversely heated, and large-scale density depletions/cavities may be created during especially active periods.

Andersson, Laila↗

Hollow core and other infrared waveguides for instrumentation in intense radiation environments.

The purpose of this LDRD was to study the effect of steady-state neutron and gamma irradiation on the transmission of waveguides designed to operate well in the near- or mid-IR region of the electromagnetic spectrum. In this context, near-IR refers to the region between 1.3 {mu}m and about 2.4 {mu}m, and mid-IR between 3.0 {mu}m and 4.5 {mu}m. Such radiation environments could exist in nuclear power plants or nuclear weapons. Pulsed and steady-state radiation effects had been extensively studied on silica-based optical fibers because they have been the most readily available, most widely used in communications and sensing, and the least expensive. However, silica-based fibers do not transmit well beyond about 1.8 {mu}m and they are virtually opaque in the mid-IR. The mid-IR, as defined above, and beyond, is where vibrational spectroscopy is carried out. This type of sensing is one important application of infrared optical fibers.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

DETECTION AND IMAGING OF THE CRAB NEBULA WITH THE NUCLEAR COMPTON TELESCOPE

The Nuclear Compton Telescope (NCT) is a balloon-borne Compton telescope designed for the study of astrophysical sources in the soft gamma-ray regime (200 keV-20 MeV). NCT's 10 high-purity germanium crossed-strip detectors measure the deposited energies and three-dimensional positions of gamma-ray interactions in the sensitive volume, and this information is used to restrict the initial photon to a circle on the sky using the Compton scatter technique. Thus NCT is able to perform spectroscopy, imaging, and polarization analysis on soft gamma-ray sources. NCT is one of the next generation of Compton telescopes-the so-called compact Compton telescopes (CCTs)-which can achieve effective areas comparable to the Imaging Compton Telescope's with an instrument that is a fraction of the size. The Crab Nebula was the primary target for the second flight of the NCT instrument, which occurred on 2009 May 17 and 18 in Fort Sumner, New Mexico. Analysis of 29.3 ks of data from the flight reveals an image of the Crab at a significance of 4{sigma}. This is the first reported detection of an astrophysical source by a CCT.

79 ASTRONOMY AND ASTROPHYSICS↗

RF pulse shape control in the compact linear collider test facility

The Compact Linear Collider (CLIC) is a study for an electron–positron machine aiming at accelerating and colliding particles at the next energy frontier. The CLIC concept is based on the novel two-beam acceleration scheme, where a high-current low-energy drive beam generates RF in series of power extraction and transfer structures accelerating the low-current main beam. To compensate for the transient beam-loading and meet the energy spread specification requirements for the main linac, the RF pulse shape must be carefully optimized. This was recently modelled by varying the drive beam phase switch times in the sub-harmonic buncher so that, when combined, the drive beam modulation translates into the required voltage modulation of the accelerating pulse. In this paper, the control over the RF pulse shape with the phase switches, that is crucial for the success of the developed compensation model, is studied. The results on the experimental verification of this control method are presented and a good agreement with the numerical predictions is demonstrated. Implications for the CLIC beam-loading compensation model are also discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Ka-band linearizer for the Ultra-Compact X-ray free-electron laser at UCLA

There is a strong demand for accelerating structures able to achieve higher gradients and more compact dimensions for the next generation of linear accelerators for research, industrial and medical applications. Notably innovative technologies will permit compact and affordable advanced accelerators as the linear collider and X-ray free-electron lasers (XFELs) with accelerating gradients over twice the value achieved with current technologies. In particular XFELs are able to produce coherent X-ray pulses with peak brightness 10 orders of magnitude greater than preceding approaches, which has revolutionized numerous research fields through imaging of the nanoscopic world at the time and length scale of atom-based systems, that is of femtosecond and Angstrom. There is a strong interest for combining these two fields, to form a proper tool with the goal of producing a very compact XFEL in order to investigate multi-disciplinary topics in chemistry, biology, materials science, medicine and physics. In the framework of the Ultra-Compact XFEL project under study at the University of California, Los Angeles, a high gradient radio-frequency accelerating structure for the longitudinal phase-space linearization with an integrated voltage of at least 15 MV working on 6th harmonic of the main Linac frequency is required. We here present the electromagnetic design of a cryogenic normal-conducting 8 cm long Ka-band standing-wave linearizer working on π mode with a target accelerating gradient beyond 100 MV/m. The studies have been performed analytically and numerically to investigate the beam dynamics and electromagnetic issues.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Spin Sum Rules and the Strong Coupling Constant at large distance

We present recent results on the Bjorken and the generalized forward spin polarizability sum rules from Jefferson Lab Hall A and CLAS experiments, focusing on the low Q{sup 2} part of the measurements. We then discuss the comparison of these results with Chiral Perturbation theory calculations. In the second part of this paper, we show how the Bjorken sum rule with its connection to the Gerasimov-Drell-Hearn sum, allows us to conveniently define an effective coupling for the strong force at all distances.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

TIME-SEQUENCED X-RAY OBSERVATION OF A THERMAL EXPLOSION

The evolution of a thermally-initiated explosion is studied using a multiple-image x-ray system. HMX-based PBX 9501 is used in this work, enabling direct comparison to recently-published data obtained with proton radiography [1]. Multiple x-ray images of the explosion are obtained with image spacing of ten microseconds or more. The explosion is simultaneously characterized with a high-speed camera using an interframe spacing of 11 mus. X-ray and camera images were both initiated passively by signals from an embedded thermocouple array, as opposed to being actively triggered by a laser pulse or other external source. X-ray images show an accelerating reacting front within the explosive, and also show unreacted explosive at the time the containment vessel bursts. High-speed camera images show debris ejected from the vessel expanding at 800-2100 m/s in the first tens of mus after the container wall failure. The effective center of the initiation volume is about 6 mm from the geometric center of the explosive.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Indoor And Outdoor Gamma Dose Measurements For Specific Counties of Trabzon-Turkey

In this study, it was determined environmental gamma radiation dose rate for some counties of Trabzon-Turkey. A detailed ambient gamma dose measurement has been performed in the seven counties of Trabzon, using a portable environmental survey meter (NaI detector, INSPECTOR 1000). The measurements were performed indoor and outdoor of buildings and also at each spot, a reading was taken at 1 m above ground level. The dose rates varied from 42.69 nGy/h and 140.91 nGy/h for indoor gamma dose and 27.84 nGy/h and 121.80 nGy/h for outdoor gamma dose . Average indoor and outdoor gamma dose rates were ascertained to be 71.05 nGy/h and 60.20 nGy/h, respectively. The annual effective doses were calculated from indoor and outdoor gamma doses to be 348.56 muSv/y and 73.83 muSv/y, respectively.

54 ENVIRONMENTAL SCIENCES↗

First results from IRENI - Rapid diffraction-limited high resolution imaging across the mid-infrared bandwidth

First results from IRENI, a new beamline at the Synchrotron Radiation Center, demonstrate that synchrotron chemical imaging, which combines the characteristics of bright, stable, broadband synchrotron source with a multi-element detector, produces diffraction-limited images at all wavelengths simultaneously. A single cell of Micrasterias maintained in a flow cell has been measured, and results show high quality spectra and images demonstrating diffraction limited, and therefore wavelength-dependent, spatial resolution.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Progress on the superconducting undulator for ANKA and on the instrumentation for R and D

Superconducting undulators show a larger magnetic field strength for the same gap and period length, as compared to permanent magnet devices, which allows to generate X-ray beams of higher brilliance and with harder spectrum. The worldwide first short period length superconducting undulator is in operation since 2005 at the synchrotron light source ANKA in Karlsruhe [1]. To further drive the development in this field a research and development program is being carried out. In this contribution we report on the last progress of the construction of a 1.5 m long superconducting undulator with a period length of 15 mm, planned to be installed in ANKA beginning 2010 to be the light source of the new beamline NANO for high resolution X-ray scattering. The key specifications of the system are an undulator parameter K higher than 2 (with a magnetic gap of 5 mm) and a phase error smaller than 3.5 degrees. Cryocoolers will keep the coils at 4.2 K for a beam heat load of 4 W. The ongoing R and D includes improvements in understanding of the magnetic field properties and of the beam heat load mechanisms. The tools and instruments under development to fulfill these tasks are also discussed.

43 PARTICLE ACCELERATORS↗

Development of electron cyclotron emission imaging system on Large Helical Device

A combined system of microwave imaging reflectometry and electron cyclotron emission (ECE) imaging has been developed for the Large Helical Device. This system includes a wide-band two-dimensional horn-antenna mixer array (HMA). The HMA consists of horn antennas, waveguides, mixers, and intermediate frequency circuits. The frequency response of the HMA is between 50 and 110 GHz. The ECE signal is selected using a 95 GHz local oscillator and a 93 GHz high-pass filter.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Detection of dust on JET with the high resolution Thomson scattering system

Dust particles have been observed with Thomson scattering systems on several tokamaks. We present here the first evidence of dust particles observed by the new high resolution Thomson scattering system on JET. The system consists of filter spectrometers that analyze the Thomson scattering spectrum from 670 to 1050 nm in four spectral channels. The laser source is a 5 J Q-switched Nd:YAG laser. Without a spectral channel at the laser wavelength, only dust particles that emit broadband light could be detected; these particles have been observed on JET after disruptions. The timing of their emission is clearly different from that expected for a Thomson scattering pulse. The light pulse from dust happens after the peak of the laser light and has a long tail.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Generation of 3 GW microwave pulses in X-band from a combination of a relativistic backward-wave oscillator and a helical-waveguide compressor

The phenomenon of passive compression of frequency-modulated (FM) pulses in a dispersive media (DM) was used to increase the peak microwave power up to the multigigawatt level. A helically corrugated waveguide was used as the DM, while a relativistic X-band backward-wave oscillator (RBWO) with a descending-during-the-pulse accelerating voltage served as a source of FM pulses. Compression of pulses down to a halfwidth of 2.2 ns accompanied by a 4.5-fold power increase up to a value of about 3.2 GW has been demonstrated.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A novel large-orbit electron beam generated by a Cuccia coupler for a Ka-band third-harmonic slotted peniotron

In this work, a novel large-orbit electron beam generated by a Cuccia coupler for a Ka-band third-harmonic slotted is proposed. The Cuccia coupler was originally used in the electron coupler for amplitude modulation and power control at ultrahigh frequencies. It is demonstrated by the 3D-PIC simulation that a 6 kV, 0.5 A beam will be gyroresonantly accelerated when a microwave power of 16 kW at 10 GHz is injected into the coupler, from which a 37 kV, 0.5 A large-orbit electron beam will be obtained; it is characterized by a relative velocity spread lower than 1% and a velocity ratio {alpha} ({upsilon}{sub perpendicular}/{upsilon}{sub z}) up to 2.3. Moreover, other electron beam parameters including transverse velocity ({upsilon}{sub perpendicular}), longitudinal velocity ({upsilon}{sub z}) and deviation of guiding center could be adjusted independently, whereas these are rather difficult for the cusp gun. Finally, the Ka-band third-harmonic slotted peniotron in 2{pi} mode driven by such a beam is verified by 3D-PIC simulation, which is predicted to yield an output power of 8 kW at 30 GHz, with a microwave power conversion efficiency up to 50% and a device efficiency up to 43%, respectively.

43 PARTICLE ACCELERATORS↗

Plasma Diagnostics of a Capillary Plasma Channel for Laser Guiding

We demonstrated the production of an optical waveguide in a capillary discharge-produced plasma using a cylindrical capillary. Plasma parameters of its waveguide were characterized by use of both a Normarski laser interferometer and a hydrogen plasma line spectrum. A space-averaged maximum temperature of 3.3 eV with electron densities of the order of 10{sup 17} cm{sup -3} was observed at a discharge time of 150 ns and a maximum discharge current of 200 A. An ultrashort, intense laser pulse was guided by use of this plasma channel.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Quantitative NO{sub 2} molecular tagging velocimetry at 500 kHz frame rate

NO{sub 2} molecular tagging velocimetry (MTV) is demonstrated at repetition rates as high as 500 kHz in a laboratory scale Mach 5 wind tunnel. A pulse burst laser and a home built optical parametric oscillator system were used to simultaneously generate the required 355 and 226 nm wavelengths for NO{sub 2} photodissociation (tagging) and NO planar laser induced fluorescence imaging (interrogation), respectively. NO{sub 2} MTV images were obtained both in front and behind the characteristic bow shock from a 5 mm diameter cylinder. From Gaussian curve fitting, an average free stream flow velocity of 719 m/s was obtained. Absolute statistical precision in velocity of {approx}11.5 m/s was determined, corresponding to relative precision of 1.6%-5%, depending upon the region of the flow probed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗