Characterizing electrical panel capacity, breaker space, and loads in U.S. single-family homes

Electrical panels distribute electricity to appliances, equipment, and other building loads and maintain safety by preventing overloads of branch circuits, feeders, and utility service wires connecting homes to the grid. Load calculations in the National Electrical Code (NEC) determine the capacity of installed electrical panels in the United States, which are rated in amps (A). Circuit breakers within electrical panels affect the magnitude and number of loads that panels can serve. In home retrofits and renovations, existing electrical panels may not accommodate new electrical loads, either due to insufficient electrical capacity or a lack of available breaker spaces. Homes with these panel constraints may need to replace existing panels with new panels that have greater capacity and breaker space.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Connecting Colorado's Renewable Resources to the Markets in a Cabon-Constrained Electricity Sector

The benchmark goal that drives the report is to achieve a 20 percent reduction in carbon dioxide (CO{sub 2}) emissions in Colorado's electricity sector below 2005 levels by 2020. We refer to this as the '20 x 20 goal.' In discussing how to meet this goal, the report concentrates particularly on the role of utility-scale renewable energy and high-voltage transmission. An underlying recognition is that any proposed actions must not interfere with electric system reliability and should minimize financial impacts on customers and utilities. The report also describes the goals of Colorado's New Energy Economy5 - identified here, in summary, as the integration of energy, environment, and economic policies that leads to an increased quality of life in Colorado. We recognize that a wide array of options are under constant consideration by professionals in the electric industry, and the regulatory community. Many options are under discussion on this topic, and the costs and benefits of the options are inherently difficult to quantify. Accordingly, this report should not be viewed as a blueprint with specific recommendations for the timing, siting, and sizing of generating plants and high-voltage transmission lines. We convened the project with the goal of supplying information inputs for consideration by the state's electric utilities, legislators, regulators, and others as we work creatively to shape our electricity sector in a carbon-constrained world. The report addresses various issues that were raised in the Connecting Colorado's Renewable Resources to the Markets report, also known as the SB07-91 Report. That report was produced by the Senate Bill 2007-91 Renewable Resource Generation Development Areas Task Force and presented to the Colorado General Assembly in 2007. The SB07-91 Report provided the Governor, the General Assembly, and the people of Colorado with an assessment of the capability of Colorado's utility-scale renewable resources to contribute electric power in the state from 10 Colorado generation development areas (GDAs) that have the capacity for more than 96,000 megawatts (MW) of wind generation and 26,000 MW of solar generation. The SB07-91 Report recognized that only a small fraction of these large capacity opportunities are destined to be developed. As a rough comparison, 13,964 MW of installed nameplate capacity was available in Colorado in 2008. The legislature did not direct the SB07-91 task force to examine several issues that are addressed in the REDI report. These issues include topics such as transmission, regulation, wildlife, land use, permitting, electricity demand, and the roles that different combinations of supply-side resources, demand-side resources, and transmission can play to meet a CO{sub 2} emissions reduction goal. This report, which expands upon research from a wide array of sources, serves as a sequel to the SB07-91 Report. Reports and research on renewable energy and transmission abound. This report builds on the work of many, including professionals who have dedicated their careers to these topics. A bibliography of information resources is provided, along with many citations to the work of others. The REDI Project was designed to present baseline information regarding the current status of Colorado's generation and transmission infrastructure. The report discusses proposals to expand the infrastructure, and identifies opportunities to make further improvements in the state's regulatory and policy environment. The report offers a variety of options for consideration as Colorado seeks pathways to meet the 20 x 20 goal. The primary goal of the report is to foster broader discussion regarding how the 20 x 20 goal interacts with electric resource portfolio choices, particularly the expansion of utility-scale renewable energy and the high-voltage transmission infrastructure. The report also is intended to serve as a resource when identifying opportunities stemming from the American Recovery and Reinvestment Act of 2009.

24 POWER TRANSMISSION AND DISTRIBUTION↗

An “Off-the-Shelf” System for Intraprocedural Electrical Current Evaluation and Monitoring of Irreversible Electroporation Therapy

IntroductionIrreversible electroporation (IRE) ablation uses a series of brief electric pulses to create nanoscale defects in cell membranes, killing the cells. It has shown promise in numerous soft-tissue tumor applications. Larger voltages between electrodes will increase ablation volume, but exceeding electrical limits may risk damage to the patient, cause ineffective therapy delivery, or require generator restart. Monitoring electrical current for these conditions in real-time enables managing these risks. This capacity is not presently available in clinical IRE generators.MethodsWe describe a system using a Tektronix TCP305 AC/DC Current Probe connected to a TCPA300 AC/DC Current Probe Amplifier, which is read on a computer using a Protek DSO-2090 USB computer-interfacing oscilloscope. Accuracy of the system was tested with a resistor circuit and by comparing measured currents with final outputs from the NanoKnife clinical electroporation pulse generator.ResultsAccuracy of measured currents was 1.64 ± 2.4 % relative to calculations for the resistor circuit and averaged 0.371 ± 0.977 % deviation from the NanoKnife. During clinical pulse delivery, the system offers real-time evaluation of IRE procedure progress and enables a number of methods for identifying approaching issues from electrical behavior of therapy delivery, facilitating protocol changes before encountering therapy delivery issues.ConclusionsThis system can monitor electrical currents in real-time without altering the electric pulses or modifying the pulse generator. This facilitates delivering electric pulse protocols that remain within the optimal range of electrical currents—sufficient strength for clinically relevant ablation volumes, without the risk of exceeding safe electric currents or causing inadequate ablation.

60 APPLIED LIFE SCIENCES↗

A computational study of the effects of graphene additions on electrical properties of polycrystalline copper

The addition of graphene has recently shown promise as a route for the significant improvement of the bulk electrical properties of metallic materials. Here, we explore the effects these additions have on the net electrical conductivity of fabricated copper-graphene (Cu-Gr) nanocomposites as a function of grain structure and grain boundary properties. Synthetic 3D microstructures were generated to represent polycrystalline copper with different average grain diameters and twinned grain boundary fractions. Then, the Poisson equation of electrical transport was solved using a finite difference method in order to predict the net electrical conductivity of each microstructure. In this context, the potential effect of graphene on the conductivity of the composite was evaluated as a function of the number of affected grain boundaries. The results of these calculations indicate that 1.) as supported by literature, net electrical conductivity decreases with decreasing grain size, 2.) the presence of twinned grain boundaries results in smaller loss of conductivity than would otherwise be expected, and 3.) the presence of graphene on the grain boundaries can be expected to lead to improvements in net electrical conductivity. However, we also find that 4.) when the Cu grain structure becomes sufficiently refined, the addition of graphene could conceivably result in significant improvements in electrical conductivity over and above coarse-grained Cu. It is estimated from our calculations that, assuming microstructures with average grain sizes between 100 nm and 100 μm and graphene conductivity 1000 to 10,000 that of a typical Cu grain boundary, an improvement in electrical conductivity of approximately 17% over that of bulk Cu may be attainable. Therefore, by performing this study we suggest a possible route for the improvement of Cu electrical properties through the addition of graphene.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Determinants of residential electricity consumption: Using smart meter data to examine the effect of climate, building characteristics, appliance stock, and occupants' behavior

We propose a method to examine structural and behavioral determinants of residential electricity consumption, by developing separate models for daily maximum (peak) and minimum (idle) consumption. We apply our method on a data set of 1628 households' electricity consumption. The results show that weather, location and floor area are among the most important determinants of residential electricity consumption. In addition to these variables, number of refrigerators and entertainment devices (e.g., VCRs) are among the most important determinants of daily minimum consumption, while number of occupants and high-consumption appliances such as electric water heaters are the most significant determinants of daily maximum consumption. Installing double-pane windows and energy-efficient lights helped to reduce consumption, as did the energy-conscious use of electric heater. Acknowledging climate change as a motivation to save energy showed correlation with lower electricity consumption. Households with individuals over 55 or between 19 and 35 years old recorded lower electricity consumption, while pet owners showed higher consumption. Contrary to some previous studies, we observed no significant correlation between electricity consumption and income level, home ownership, or building age. Some otherwise energy-efficient features such as energy-efficient appliances, programmable thermostats, and insulation were correlated with slight increase in electricity consumption. (C) 2013 Elsevier Ltd. All rights reserved.

Kavousian, A↗

Impedance sources (Z sources) with inherent fault protection for resilient and fire-free electricity grids

Modern societies would not survive without electricity and at the same time electrical faults could cause and have caused many catastrophes—mainly deadly fires—to our societies. There are two types of electricity sources: the voltage source such as generators, charged batteries and capacitors, and the current source such as charged inductors, current-regulated rectifiers, and superconducting magnetic energy storage. An “ideal” voltage source—that is often-sought-or-intentionally engineered—generates a constant voltage irrespective of its load current, and an “ideal” current source injects a constant current irrespective of its load voltage. However, two problems exist: (1) voltage or current sources do not represent many emerging natural/renewable energy sources such as wind turbine generators, photovoltaic cells, and fuel cells, whose output voltage and current are strongly dependent on each other, and (2) a short-circuit fault to an artificially-made and controlled “ideal” voltage source or an open-circuit fault to an “ideal” current source can cause catastrophic failures of the source itself and its surrounding circuits due to large (theoretically infinite) short-circuit current or open-circuit voltage. Here we introduce an impedance source concept to represent, characterize, and model those electricity sources whose output voltage and current are strongly dependent on each other. First, we found that many electric sources with no feedback (or active) control of their output voltage and/or current are a natural impedance source with inherent fault protection at short-circuit or open-circuit faults. Second, any electrical source can be artificially controlled to mimic a natural impedance source. Finally, we show how to apply natural impedance sources and nature-mimicking artificially-controlled sources to the electricity grid—the most complex machine ever made by human beings—to realize electricity grids that are naturally stable, self-protected against electrical faults, and resilient to natural and human-made events.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Impact of CH 4 addition on the electron properties and electric field dynamics in a Ar nanosecond-pulsed dielectric barrier discharge

Non-equilibrium plasmas derive their low temperature reactivity from producing and driving energetic electrons and active species under large electric fields. Therefore, the impact of reactants on the plasma properties including electron number density, electric field, and electron temperature is critical for applications such as plasma CH 4 reforming. Due to experimental complexity, electron properties and the electric field are rarely measured together in the same discharge. Here, we combine time-resolved Thomson scattering and electric field induced second harmonic generation (EFISH) to probe electron temperature, electron density, and electric field strength in a 60 Torr CH 4 /Ar nanosecond-pulsed dielectric barrier discharge (ns-DBD) while varying the CH 4 mole fraction from 0 to 8%. These measurements are compared to a 1-D numerical model to benchmark its predictions and identify areas of uncertainty. Nonlinear coupling between CH 4 addition, electron temperature, electron density, and the electric field was directly observed. Contrary to previous measurements in He, the electron temperature increased with CH 4 mole fraction. This rise in electron temperature is identified as electron heating by residual electric fields that increased with larger CH 4 mole fraction. Moreover, the electron number density has been found to decrease rapidly with the increase of methane mole fraction. Comparison of these measurements with the model yielded better agreement at higher CH 4 mole fractions and with the usage of ab initio calculated Ar electron-impact cross-sections from the B-spline R-matrix (BSR) database. Furthermore, the calculated plasma properties are shown to be sensitive to the residual surface charge implanted on the quartz dielectric surfaces. Without considering surface charge in the simulations, the calculated electric field profiles agreed well with the measurements, but the electron properties were underpredicted by more than a factor of three. Therefore, measurements of either the electric field or electron properties measurements alone are insufficient to fully validate modelling predictions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Electrical signaling in fungi: past and present challenges

Abstract Electrical signaling is a fundamental mechanism for integrating environmental stimuli and coordinating responses in living organisms. While extensively studied in animals and plants, the role of electrical signaling in fungi remains a largely underexplored field. Early studies suggested that filamentous fungi generate action potential-like signals and electrical currents at hyphal tips, yet their function in intracellular communication remained unclear. Renewed interest in fungal electrical activity has fueled developments such as the hypothesis that mycorrhizal networks facilitate electrical communication between plants and the emerging field of fungal-based electronic materials. Given their continuous plasma membrane, specialized septal pores, and insulating cell wall structures, filamentous fungi possess architectural features that could support electrical signaling over long distances. However, studying electrical phenomena in fungal networks presents unique challenges due to the microscopic dimensions of hyphae, the structural complexity of highly modular mycelial networks, and the limitations of traditional electrophysiological methods. This review synthesizes current evidence for electrical signaling in filamentous fungi, evaluates methodological approaches, and highlights experimental challenges. By addressing these challenges and identifying best practices, we aim to advance research in this field and provide a foundation for future studies exploring the role of electrical signaling in fungal biology.

Buffi, Matteo↗

Toward Quantifying Kinetics of Biotic and Abiotic Metal Reduction with Electrical Geophysical Methods (Final Report)

Although changes in the bulk electrical conductivity in aquifers have been attributed to microbial activity, electrical conductivity has never been used to infer biogeochemical reaction rates quantitatively. To explore the use of electrical conductivity to measure reaction rates, we conducted iron oxide reduction experiments of increasing biological complexity. To quantify reaction rates, we proposed composite reactions that incorporated the stiochiometry of five different types of reactions: redox, acid-based, sorption, dissolution/precipitation, and biosynthesis. In batch and column experiments, such reaction stiochiometries inferred from a few chemical measurements allowed quantification of the Fe-oxide reduction rate based on changes in electrical conductivity. The relationship between electrical conductivity and fluid chemistry did not hold during the latter stages of the column experiment when electrical conductivity increased while fluid chemistry remained constant. Growth of an electrically conductive biofilm could explain this late stage electrical conductivity increase. This work demonstrates that measurements of electrical conductivity and flow rate, combined with a few direct chemical measurements, can be used to quantify biogeochemical reaction rates in controlled laboratory situations and may be able to detect the presence of biofilms.

54 ENVIRONMENTAL SCIENCES↗

Cyber Threat and Vulnerability Analysis of the U.S. Electric Sector

With utilities in the U.S. and around the world increasingly moving toward smart grid technology and other upgrades with inherent cyber vulnerabilities, correlative threats from malicious cyber attacks on the North American electric grid continue to grow in frequency and sophistication. The potential for malicious actors to access and adversely affect physical electricity assets of U.S. electricity generation, transmission, or distribution systems via cyber means is a primary concern for utilities contributing to the bulk electric system. This paper seeks to illustrate the current cyber-physical landscape of the U.S. electric sector in the context of its vulnerabilities to cyber attacks, the likelihood of cyber attacks, and the impacts cyber events and threat actors can achieve on the power grid. In addition, this paper highlights utility perspectives, perceived challenges, and requests for assistance in addressing cyber threats to the electric sector. There have been no reported targeted cyber attacks carried out against utilities in the U.S. that have resulted in permanent or long term damage to power system operations thus far, yet electric utilities throughout the U.S. have seen a steady rise in cyber and physical security related events that continue to raise concern. Asset owners and operators understand that the effects of a coordinated cyber and physical attack on a utility’s operations would threaten electric system reliability–and potentially result in large scale power outages. Utilities are routinely faced with new challenges for dealing with these cyber threats to the grid and consequently maintain a set of best practices to keep systems secure and up to date. Among the greatest challenges is a lack of knowledge or strategy to mitigate new risks that emerge as a result of an exponential rise in complexity of modern control systems. This paper compiles an open-source analysis of cyber threats and risks to the electric grid, utility best practices for prevention and response to cyber threats, and utility suggestions about how the federal government can aid utilities in combating and mitigating risks.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Development of Cost-Competitive Advanced Thermoelectric Generators for Direct Conversion of Vehicle Waste Heat into Useful Electrical Power

General Motors LLC (GM) proposed a project to develop a cost-effective thermoelectric generator (TEG) that is fully integrated into a GM production light-duty vehicle. The project goal was to reduce automotive energy consumption and CO 2 emissions by generating usable electricity from exhaust gas waste heat. The project objectives were to overcome the major obstacles to TEG commercialization and demonstrate 5% fuel economy improvement over the US06 drive cycle. We investigated electrical and thermal management strategies that included: (1) reducing electrical accessory load on the alternator using thermoelectric (TE) generated power; (2) shifting engine-driven accessories to electrical drive to raise the electrical accessory load consumption; (3) attempting to use the excess electrical power for something other than the vehicle electrical load e.g., propulsion (optimal for hybrids); and (4) implementing fast engine/transmission warm-up during cold-start. We developed a TEG system and all vehicle controls and electrical systems for full vehicle integration. The TEG system was modeled and analyzed for performance and cost. Heat exchangers and thermal interfaces between heat exchangers and TE modules were optimized for TE performance. Other objectives of the project were to (1) further optimize compositions and processing parameters for TE materials, (2) develop suitable diffusion barriers, interfaces electrical interconnections, and thermal contacts within TE modules, (3) implement adequate protection of TE materials and modules from degradation during operation, and (4) develop manufacturing and assembly processes for large scale production of TE materials and components that include scale-up plans for the production of 100,000 TEG units per year.

33 ADVANCED PROPULSION SYSTEMS↗

Draft Electric Rule 21 Test Protocols for Advanced Inverter Functions

Disclaimer: The following document includes draft certification protocols and should not be viewed as a consensus-based performance standard. Distributed energy resources (DERs), such as photovoltaic (PV) systems, when deployed in a large scale, are capable of significantly influencing the operation of bulk and local power systems. Looking to the future, European and American stakeholders are working on standards to make it possible to manage the potentially complex interactions between DER and the power system. One of the jurisdictions considering modifications to the DER interconnection requirements is California. To determine what changes could improve electric grid reliability and allow greater penetrations of renewable energy, the California Public Utilities Commission (CPUC) and the California Energy Commission (CEC), in conjunction with consultant Frances Cleveland, convened the Smart Inverter Working Group (SIWG) in January 2013. The SIWG--composed of state agencies, utility engineers, national laboratories, manufacturers, trade associations, and advocacy groups--provided the CPUC a set of recommendations in early 2014 1 . The recommendations included specific advanced DER functions and interoperability requirements, along with a proposed timeline, for California to add new capabilities to grid-interconnected DER. On August 18, 2014 the three California Investor-Owned Utilities (IOUs)--Pacific Gas and Electric Company (PG&E), Southern California Edison Company (SCE) and San Diego Gas & Electric Company (SDG&E)--drafted a Advice Letter filing to the CPUC setting forth revisions to Electric Tariff Rule 21 to conform to the seven recommendations made by the Working Group 2 . After a comment period, the CPUC issued an update to the IOU recommendations 3 . At the time of this publication, there was no final legal ruling on the CPUC Rulemaking (R.) 11-09-011 ("Order Instituting Rulemaking on the Commission's Own Motion to improve distribution level interconnection rules and regulations for certain classes of electric generators and electric storage resources"). In the U.S., Nationally Recognized Test Laboratories (NRTLs) independently verify products to safety and functional standards. PV inverters are certified to Underwriters Laboratories (UL) Standard 1741 4 . However, new advanced inverter functions described in the SIWG and IOU proposals are not included in this standard, so there is a critical need to develop test protocols for these functions in preparation of a positive ruling by the CPUC. Through a California Solar Initiative Grant, Sandia National Laboratories (Sandia or SNL), Underwriters Laboratories (UL), Electric Power Research Institute, Inc. (EPRI), Xanthus Consulting, SunSpec Alliance, Loggerware, and utility and PV inverter manufacturers have collaborated to draft this certification protocol for the Rule 21 SIWG Phase 1 advanced inverter functions. This report also includes test procedures for Phase 2 and Phase 3 functions that will be demonstrated later in the CSI4 project. This collaborative effort was performed in close junction with the UL 1741 Standards Technical Panel (STP) working group. This document represents a snapshot of the draft testing protocols at the time of publication and not a consensus certification protocol for advanced inverters. 1 California Public Utilities Commission, "Recommendations for Updating the Technical Requirements for Inverters in Distributed Energy Resources, Smart Inverter Working Group Recommendations," Filed 7 Feb 2014. 2 J.J. Newlander, R.G. Litteneker, S.W. Walter, M. Dwyer, Joint motion of Pacific Gas and Electric Company (U 39 E), Southern California Edison Company (U 338 E) and San Diego Gas & Electric Company (U 902 E) regarding implementation of smart inverter functionalities, Rulemaking 11-09-011 Advice Letter, 18 July, 2014. 3 J.T. Sullivan, CPUC Rulemaking 11-09-011 Agenda ID #13460, 13 Nov, 2014. 4 Underwriters Laboratories Std. 1741 Ed. 2, "Inverters, Converters, Controllers and Interconnection System Equipment for use with Distributed Energy Resources," 2010.

42 ENGINEERING↗

Methods to Incorporate Energy Efficiency in Electricity System Planning and Markets

Electric utilities, independent system operators and regional transmission operators have acquired significant levels of energy efficiency over several decades. The predominant approach utilities use to consider energy efficiency in electricity system planning and ISO/RTOs use in wholesale electricity markets is to reduce load forecasts to account for estimated impacts of relevant policies and programs. But an increasing number of states and utilities are interested in improved analysis of energy efficiency in electricity system planning and wholesale electricity markets. This report describes how to consider energy efficiency as a potential resource for the future by allowing it to compete with all other electricity system resources. Increasing levels of wind and solar, growth in peak demand, and electrification of transportation and other new loads have increased the need for a more flexible and responsive electricity system. Considering energy efficiency as a resource option can support these and other electricity system objectives, including grid reliability, reduced electricity costs, energy efficiency targets, and lower air pollutant emissions. The October 2019 slides were presented at the American Council for an Energy Efficient Economy Energy Efficiency as a Resource conference and provide an overview of the report. Portions of the report were included in the American Council for an Energy Efficient Economy Energy Efficiency 2020 Summer Study paper, Planning for the Grid of Tomorrow: Energy Efficiency as a Resource in Utility Resource Plans.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Regional Variation in Light-Duty Plug-in Electric Vehicle Emissions

Automobile electrification is viewed as one of the key requirements for deep decarbonization of transportation. However, the exact magnitude of decarbonization from switching from a combustion of petroleum-based fuels to grid-derived electricity is a complex issue. Variations in local grid mixes lead to differing carbon intensities of electricity in different regions. This complexity is compounded by geographical differences in vehicle characteristics. This analysis considers these geographic differences to produce a historical assessment of the fuel-cycle carbon emissions of plug-in electric vehicles (PEVs) in the United States from 2011 to 2021. We find that PEVs in the United States decreased in electricity-derived carbon intensity, from 187 grams per mile to 110 grams per mile from 2011 to 2021 due to improvements in the electric grid and vehicle efficiency. Through 2021, PEVs emitted a total of 13.6 million metric tons of greenhouse gas (GHG) emissions in the United States, including both emissions from electricity and gasoline, while driving a total of 100 billion miles. Of this total, 8.39 million metric tons was due to electricity consumption. Over the same distance, comparable gasoline vehicles would have emitted between 29 and 41 million metric tons of GHG, leading to a reduction of 15 to 27 million metric tons. Relative to national-level assessments that do not factor in this regional difference, these electric vehicles resulted in 13% greater reductions in GHG emissions than previously calculated. In the future, announced goals to further decarbonize the electricity sector will continue to reduce the emissions of PEVs, including reducing emissions rates for vehicles already on the road, further improving the benefits relative to the unchanging emissions of contemporaneous gasoline vehicles.

02 PETROLEUM↗

Assessment of Light-Duty Plug-in Electric Vehicles in the United States, 2010 – 2021

The number of plug-in electric vehicles (PEVs) sold in the United States has consistently grown since 2010, reaching 4% of the light-duty vehicle market in 2021. This report examines how the characteristics for these PEVs has changed over this decade, evaluating range, energy efficiency, costs, and performance. Given the vehicle characteristics, this report estimates miles driven, electricity consumption, petroleum reduction, and greenhouse gas emissions attributable to electric vehicles. This report also explores vehicle manufacturing and battery production, considering supply chains from battery cells to assembly. Over 2.1 million PEVs have been sold in the United States through December 2021, with 1.3 million of these all fully-electric battery electric vehicles (BEV), and 800,000 plug-in hybrid electric vehicles (PHEV) which have the capability of using gasoline. The sales-weighted average range for BEVs reached 290 miles in 2021 and 28 miles for PHEVs. We estimate that electric vehicles have driven 68 billion miles on electricity since 2010, thereby reducing national gasoline consumption by 0.54% in 2021 and 2.5 billion gallons cumulatively through 2021. In 2021, PEVs used 6.1 terawatt-hours of electricity to drive 19.1 billion miles, offsetting 700 million gallons of gasoline. We find that this fuel switching reduced consumer fuel costs by $1.3 billion in 2021. Since 2010, 65% of PEVs sold in the United States have been assembled domestically, and over 110 gigawatt-hours of lithium-ion batteries have been installed in vehicles to date.

25 ENERGY STORAGE↗

Electric field and plasma observations in the magnetosphere

Satellite-borne electric field measurements using the double probe technique have now provided a comprehensive survey of convection electric fields at low altitudes in the magnetosphere. The most prominent features of the convection electric fields are reversals located at high magnetic latitudes, with generally anti-sunward convection poleward and sunward convection equatorward of the electric field reversal location. On the day side of the magnetosphere the electric field reversal is observed to coincide with the equatorward boundary of the polar cusp. In the local afternoon and evening regions inverted V electron precipitation bands occur at or near the electric field reversal and in regions usually characterized by large fluctuations in the electric field. In the local midnight region strong convection electric fields have also been observed deep within the magnetosphere, near the equatorward boundary of the plasma sheet. Recent measurements of electric fields near the inverted V electron precipitation bands suggests that these events are associated with large electrostatic potential gradients along the geomagnetic field.

Gurnett, D. A.↗

Auroral zone electric fields from DE 1 and 2 at magnetic conjunctions

Nearly simultaneous measurements of auroral zone electric fields are obtained by the Dynamics Explorer spacecraft at altitudes below 900 km and above 4,500 km during magnetic conjunctions. The measured electric fields are usually perpendicular to the magnetic field lines. The north-south meridional electric fields are projected to a common altitude by a mapping function which accounts for the convergence of the magnetic field lines. When plotted as a function of invariant latitude, graphs of the projected electric fields measured by both DE-1 and DE-2 show that the large-scale electric field is the same at both altitudes, as expected. Superimposed on the large-scale fields, however, are small-scale features with wavelengths less than 100 km which are larger in magnitude at the higher altitude. Fourier transforms of the electric fields show that the magnitudes depend on wavelength. Outside of the auroral zone the electric field spectrums are nearly identical. But within the auroral zone the high and low altitude electric fields have a ratio which increases with the reciprocal of the wavelength. The small-scale electric field variations are associated with field-aligned currents. These currents are measured with both a plasma instrument and magnetometer on DE-1.

Weimer, D. R.↗

A new direction in energy conversion - The all-electric aircraft

This paper reviews recent studies of all-electric aircraft that use electric-only secondary power and flight critical fly-by-wire flight controls, and brings to the attention of the power system designer the intrinsic advantages of such aircraft. The all-electric aircraft is made possible by the development of rare earth magnet materials and fault tolerant systems technologies. Recent studies have shown all-electric aircraft to be more efficient than conventional designs and offer substantial operating costs reductions. Compared to present aircraft, an all-electric transport can save at least 10 percent in fuel burn. The cornerstone of an all-electric aircraft is the electric secondary power system. This paper reviews the major features of flight critical electric secondary power systems. Research required to lay the foundation for an all-electric aircraft is briefly discussed.