Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Diesel”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 883 records · Page 49

Validation of Interconnection and Interoperability of Grid-Forming Inverters Sourced by Hydrogen Technologies in View of 100% Renewable Microgrids

Grid-forming assets are required in microgrids to act as voltage-frequency masters. These grid-forming assets can operate in two modes of operation: grid-following mode and grid-forming mode. In grid-following mode of operation, these assets will follow real power and reactive power setpoints and in grid-forming mode of operation these assets will follow voltage and frequency setpoints. Traditionally, diesel generators or natural gas-based generators are widely used to act as a voltage-frequency master. However, many utilities are aiming to replace generators with grid forming-inverters supplied by solar photovoltaics (PV), batteries or fuel cells. Since grid-forming assets need a long-term reliable energy source, fuel cells are a reasonable and viable choice to supply the grid-forming inverters, but some of the challenges facing the wide deployment of grid-forming fuel cell inverters need to be addressed. Specifically, in our proposed work, we aim to focus on the interconnection and interoperability requirements of grid-forming fuel cell inverters. Currently, state-of-the-art fuel cell inverters follow the general interconnection requirements of distributed energy resources (DERs) and general interoperability requirements of DERs, but these requirements were built with PV and battery systems in mind. Fuel cells have different operational requirements, and therefore these requirements need to be appropriately modified for the grid operators to use. These additional steps add to the investment and operational cost to the grid operators. Through the ARIES platform, this proposed project aims to bridge this gap and use power hardware-in-the-loop (PHIL) and controller hardware-in-the-loop (CHIL) experiments to inform the creation of open-source interconnection and interoperability information that can aid in faster and cheaper installation and operation of grid-forming fuel cell inverters.

grid-forming↗

Droop Control-Based Dispatch of an Islanded Microgrid With Multiple Grid-Forming Sources

Before rotating, fossil fuel-based, synchronous generators (SGs) are phased out, in line with renewable generation goals, grid-forming (GFM) inverters are expected to parallel SGs. Primary droop control allows GFM inverters to share power without communication; however, it is necessary to dispatch GFM inverters and/or SGs with the desired output power for better energy management (e.g., one GFM inverter needs to charge the battery due to a low state of charge). Therefore, this paper develops an analytic approach to dispatching GFM inverters and SGs with the desired output power by shifting the droop intercept up/down while maintaining the same frequency operating point for improved transient stability. This concept is demonstrated through a pure hardware setup with two off-the-shelf inverters and one diesel generator under an islanded microgrid, and we provide insight on the real-world implementation of the proposed concept.

droop control↗

Droop Control-Based Dispatch of an Islanded Microgrid with Multiple Grid-Forming Sources: Preprint

Before rotating fossil-fuel based synchronous generators (SGs) are phased out in line with renewable goals, grid-forming (GFM) inverters are expected to parallel with SGs. Primary droop control allows them share power without communication, however, it is necessary to dispatch GFM inverters and/or SG with desired output power for better energy management (e.g., one GFM inverter needs to charge the battery due to low state-of-the charge). Therefore, this paper develops analytic approach to dispatch GFM inverters and SG with desired output power by shifting the droop intercept up/down while maintain the same frequency operating point for improved transient stability. This concept is demonstrated through pure hardware setup with two off-the-shelf inverters and one diesel generator under islanded microgrid, and we also provide insight on real-world implementation of the proposed concept.

droop control↗

Enabling a Sustainable Future: Zero-Emission Vehicles Cost Analysis to Inform Decarbonization Pathways

Despite being only 5% of vehicles on the road, medium- and heavy-duty vehicles (MHDVs) are the second largest contributor to transportation emissions (21%) and a major source of local air pollution disproportionally affecting disadvantaged communities. This talk summarizes a cost analysis for zero emissions vehicles (battery electric EVs and hydrogen fuel cell FCEVs) for all medium and heavy duty applications, ranging from large pick-up trucks, to delivery vans, buses, and heavy trucks. Results show that with continued improvements in vehicle and fuel technologies (in line with U.S. Department of Energy targets and vetted with industry), zero-emission vehicles (ZEVs) can reach total-cost-of-driving parity with conventional diesel vehicles by 2035 for all medium- and heavy-duty (MD/HD) vehicle classes without incentives. Assuming economics drives adoption, ZEV sales could reach 42% of all MD/HD trucks by 2030, reflecting lower combined vehicle purchase and operating costs (using real-world payback periods). Two technological solutions - battery electric vehicles (BEVs) and fuel cell electric vehicles (FCEVs) - are viable in multiple market segments, offering alternative pathways for decarbonization: a) BEVs tend to become cost-competitive for smaller trucks before 2030 and for short-haul (<500-mile) heavy trucks before 2035. b) Hydrogen FCEVs tend to become cost-competitive for long-haul (>500-mile) heavy trucks by 2035. Results are very sensitive to technology improvement trajectories, adoption decision-making, and uncertain assumptions about future freight demand, logistics, and vehicle use explored in multiple scenarios.

ADVANCED PROPULSION SYSTEMS,ENERGY PLANNING, POLIC↗

Optical Investigation of Catalyst Heating Operation in a Light-Duty Compression-Ignition Engine

It is well known that cold start engine operation contributes a majority of tail-pipe emissions during a vehicle drive cycle. Aftertreatment catalysts have poor conversion efficiency during this period due to low conversion efficiency at temperatures less than their light-off temperature. A late post injection strategy, with a delayed injection to increase exhaust enthalpy, can help decrease the time required to heat-up the catalyst. However, late injections into conditions with decreasing temperature and density can result in high emissions and combustion instability. In this study a three-injection strategy with a late-post injection was investigated in an optically-accessible engine. For the first two injections (pilot and main) timing and duration were held constant as the post injection timing was swept and duration varied to hold load constant, at a relevant light-load catalyst heating operating condition. Simultaneous double-pass schlieren and OH chemiluminescence data were acquired in an optically-accessible 0.4 L single-cylinder engine to understand spray characteristics and combustion behavior for #2 diesel fuel. Optical images analysis revealed higher liquid penetration and lower vaporization of the liquid fuel jet as post injection is retarded. It is also observed that retarding post injection timing to +25 CAD resulted in lower observed soot concentration in the piston bowl.

99 GENERAL AND MISCELLANEOUS↗

Additives for improving autoignition reactivity of hydrocarbon-based fuels

According to various aspects, an additive for a hydrocarbon-based fuel has a formula (I), in which R 1 , R 2 , and R 3 are each independently selected from —H, —CH 3 , or —CH 2 CH 3 , and at least one of R 1 , R 2 , and R 3 is not —H. The additive improves an autoignition reactivity of the hydrocarbon-based fuel. The additive can be present in the fuel composition including the additive and the hydrocarbon-based fuel in an amount of 0.1% by volume to 5% by volume. The hydrocarbon-based fuel can comprise gasoline or diesel.

Lopez Pintor, Dario↗

WIPP Safety Significant Confinement Ventilation System (SSCVS) HEPA Filtration System - 20165

Construction and major equipment fabrication are underway for a new ventilation exhaust system at the Waste Isolation Pilot Plant (WIPP). The new system will provide continuous High Efficiency Particulate Air (HEPA) filtration of the exhaust from the WIPP underground while meeting the ventilation demands for expanded waste emplacement and mining operations over the next 40 years. The integrated system design provides for reducing the salt, clay and diesel particulates from the exhaust airflow from the mine, prior to full filtration using Nuclear Safety Significant HEPA filters. The SSCVS design and equipment provides for continuous HEPA filtration over a wide range of operating and environmental conditions. The new exhaust system connects to the existing underground exhaust shaft, and the exhaust air flows from the underground through Salt Reduction Units (SRUs) to protect the final filter banks from excessive moisture and rapid salt/dust buildup. Each of the six (6) SRUs consists of a demister to remove entrained moisture, a dry salt remover unit to filter approximately 90% of the entrained salt/dust, and an automated water treatment system to periodically clean the demisters and to remove salt from the SRU filters. At the maximum expected exhaust flowrate of 540,000 Cubic Feet per Minute (CFM) / 255 Cubic Meters per Second (m{sup 3}/s), five (5) salt removal units will be in operation with one unit in standby or maintenance. An in-line variable frequency drive booster fan will offset pressure losses through each SRU and reduce the relative humidity of the air exiting the SRUs. In the event of a high radiation alarm from the underground Continuous Air Monitors (CAMs), the SRUs will be automatically bypassed, which places the SRS and building outside of the Safety Significant confinement boundary. From the SRUs, the exhaust is directed to the HEPA filter banks located in the New Filter Building. The exhaust system is designed to provide continuous HEPA filtration prior to release to the exhaust stack. There are 22 HEPA filter banks rated at 27,000 CFM / 12.75 m{sup 3}/s each. Each filter bank has two stages of pre-filters and two stages of HEPA filters. The filtered air from each of the 22 filter banks discharges into a common concrete plenum, which is maintained under a negative pressure by the main exhaust fans. Six 1,000 HP variable frequency drive exhaust fans are provided on the south side of the plenum. At the maximum expected exhaust flow of 540,000 CFM, four exhaust fans and twenty filter banks will be in operation. The fans discharge vertically to a separate concrete exhaust plenum. The filtered exhaust is routed from the exhaust plenum to a 125-foot-tall exhaust stack via a 13-foot diameter duct. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

SAE Government-Industry - Heavy-Duty Policy: Panel Discussion (G203)

Medium- and heavy-duty vehicles are 21% of US transportation greenhouse gas (GHG) emissions and a major source of air pollution. In this talk to present some results exploring how the total cost of driving (TCD) of zero-emission vehicles (ZEVs), including battery electric vehicles and hydrogen fuel cell electric vehicles (EVs and FCEVs), could evolve under alternative scenarios. Results show that with continued improvements in vehicles and fuels, ZEVs can rapidly become viable, potentially reaching TCD parity or better compared to diesel vehicles by 2035 for all market segments. For heavy long-haul trucks, EVs become competitive on a TCD basis at charging costs below $0.18/kWh, while FCEVs become competitive on a TCD basis at hydrogen costs below $5/kg. A full transition to ZEV sales by 2035 results in 65% emissions reductions by 2050 compared to 2019 without supportive policies. Incentives such as the Inflation Reduction Act vehicle purchase credits further accelerate ZEV TCD competitiveness with major adoption opportunities over the next five years.

ADVANCED PROPULSION SYSTEMS,DIRECT ENERGY CONVERSI↗

Modeling for a Digital Twin-Based Remote Operation System Framework

New reactor designs and technologies are being developed to grow and advance the nuclear industry. Microreactors are one of the many new concepts for advancing the industry. Microreactors are very small reactors generally designed to have an operating power of 20 MWth or less. They are ideal for many applications in which it would not be feasible to have a large-scale reactor, such as powering remote communities, military bases, and mining sites. Many of these applications currently rely on diesel generators for power, and replacing those generators with the carbon-free energy of a microreactor is a major driving factor for microreactor development. However, most of the use cases for microreactors are in isolated locations where construction and labor costs are much higher. Microreactors will need to be comparable to other energy production methods for their deployment to be successful. Remotely operating the microreactor has a great potential to benefit the economics and make it more cost competitive. With remote operations, the operation facility location could be strategically chosen based on factors such as construction costs, workforce size, etc. The benefits of remote operations could be leveraged even more if the remote operation system is semi-autonomous. If the remote operation system is semi-autonomous, more microreactors could be operated and monitored from one remote operation facility. Additionally, with the system handling some tasks for the human operator, it could reduce the number of operating staff necessary for the microreactor. Digital twins can be used to introduce a level of automation to the remote operation system. Digital twins are capable of component monitoring, system operation and control, and predictive performance [1]. All of those features are important for a successful semi-autonomous remote operation system.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Validation of Interconnection and Interoperability of Grid-Forming Inverters Sourced by Hydrogen Technologies in View of 100% Renewable Microgrids

Grid-forming assets are required in microgrids to act as voltage-frequency masters. These grid-forming assets can operate in two modes of operation: grid-following mode and grid-forming mode. In grid-following mode of operation, these assets will follow real power and reactive power setpoints and in grid-forming mode of operation these assets will follow voltage and frequency setpoints. Traditionally, diesel generators or natural gas-based generators are widely used to act as a voltage-frequency master. However, many utilities are aiming to replace generators with grid forming-inverters supplied by solar photovoltaics (PV), batteries or fuel cells. Since grid-forming assets need a long-term reliable energy source, fuel cells are a reasonable and viable choice to supply the grid-forming inverters, but some of the challenges facing the wide deployment of grid-forming fuel cell inverters need to be addressed. Specifically, in our proposed work, we aim to focus on the interconnection and interoperability requirements of grid-forming fuel cell inverters. Currently, state-of-the-art fuel cell inverters follow the general interconnection requirements of distributed energy resources (DERs) and general interoperability requirements of DERs, but these requirements were built with PV and battery systems in mind. Fuel cells have different operational requirements, and therefore these requirements need to be appropriately modified for the grid operators to use. These additional steps add to the investment and operational cost to the grid operators. Through the ARIES platform, this proposed project aims to bridge this gap and use power hardware-in-the-loop (PHIL) and controller hardware-in-the-loop (CHIL) experiments to inform the creation of open-source interconnection and interoperability information that can aid in faster and cheaper installation and operation of grid-forming fuel cell inverters.

controller hardware-in-the-loop↗

Dispatching Grid-Forming Inverters in Grid-Connected and Islanded Mode: Preprint

This paper explores the dispatch-ability of grid-forming (GFM) inverters in grid-connected and islanded mode. Grid-forming (GFM) inverters usually use droop control to automatically share power with other GFM sources (inverters and synchronous generator (SG)) and follow the change of the load demand. However, they can be dispatched like their grid-following (GFL) counterparts to output the target active and reactive power. This will help the grid operator better manage their inverter-based resources (IBRs) for improved operation efficiency and reliability. Therefore, this paper proposes an innovative concept of dispatching GFM sources (inverters and SG) to output the target power for both grid-connected and islanded mode by adjusting their droop intercepts. The fundamental principle of doing so is that the GFM inverter's active and reactive power is dictated by its frequency and voltage, thus, dispatching active and reactve power of a GFM inverter can be achieved through dispatching its frequency and voltage. Moreover, the concept distinguishes the dispatch rules for grid-connected and islanded mode. Finally, the concept is validated with an example microgrid system with two GFM inverters, one diesel generator, one grid-following inverter and loads in both grid-connected and islanded mode. This pioneering work results in a practical guidance for power system energy management system (EMS) development to control a future grid with GFM and GFL inverters.

droop control↗

Biofuels as Heavy Fuel Oil Substitutes in the Maritime Sector: Findings and Potential Pathways

The United States Department of Energy has commissioned four national laboratories to evaluate the feasibility of biofuels in the maritime sector. This effort is briefly described including the overall project goals, structure and aims. The large two-stroke crosshead engines used to power large merchant vessels were of particular interest since they can burn lower combustion quality fuels relative to four-stroke engines. This characteristic allows for consideration of pyrolysis oils and hydrothermal liquefaction (HTL) oils which are feedstock agnostic and, in the raw state, are more economical compared to distillate drop-in fuels. Pyrolysis and HTL oils are collectively known as bio-intermediates since they require additional processing for use in distillate fuel systems. The key limiting feature is that these bio-intermediate fuels will cause asphaltene precipitation when blended with heavy fuel oils (HFOs) such as very low sulfur fuel oil (VLSFO) unless they are upgraded to remove water and oxygenates. Economics are the key driver at this point in time, and preliminary techno-economic analyses (TEAs) indicate that bio-intermediates have potentially lower cost relative to other biofuels such as biodiesel and renewable diesel. Additionally, life cycle analyses (LCAs) of feedstocks and pathways show the life cycle carbon reduction benefit relative to heavy fuel oils. In addition to TEA and LCA results, we also present on the technical feasibility of these fuels. These studies have focused on the properties of biofuel blends with VLSFO that are critical to the fuel systems of maritime vessels fueled with HFOs. These properties include the compatibility with fuel system metals, viscosity, and blend stability. Aging studies with blends of VLSFO with biodiesel, HTL, and pyrolysis oils are also presented. Future efforts being planned to conduct additional biofuel testing, including the use of biofuels as pilot fuels in zero carbon shipping options fueled with ammonia and methanol, ship-based demonstrations, and bioresource competition studies.

Kass, Michael↗

Dispatching Grid-Forming Inverters in Grid-Connected and Islanded Mode

This paper explores the dispatchability of grid-forming (GFM) inverters in grid-connected and islanded mode. An innovative concept of dispatching GFM sources (inverters and synchronous generators) is proposed to output the target power by adjusting their droop intercepts. The fundamental principle is that the GFM inverter's active and reactive power is dictated by its frequency and voltage, and thus dispatching the active and reactive power of a GFM inverter can be achieved through dispatching its frequency and voltage. The concept is validated with an example microgrid system with two GFM inverters, one diesel generator, one GFL inverter, and the load in both grid-connected and islanded mode. This pioneering work results in practical guidance for the development of energy management systems for future electric grids with GFM and GFL inverters. The key findings are summarized as follows: 1) The GFM inverters can be dispatched through frequency and voltage droop intercepts to output the target power; 2) The dispatch rule for grid-connected and islanded mode is slightly different.

dispatch GFM inverter↗

Development of Hydrogen-Fueled, Highly Energy-Efficient, Electro-Hydraulic Excavator

Regulations for CO2 emissions reduction are driving increasing demand for “zero emissions” off-road vehicles (ORVs). Hydrogen internal combustion engines (H2 ICEs) are closer to commercial viability, and less expensive than fuel cells. The major challenge is the slow torque response of H2 ICEs, that makes it difficult to sustain the harsh torque requirements typical of ORVs. The goal of this paper is to overcome this challenge by proposing an electro-hydraulic hybrid technology with hybrid powertrain and multi-pressure rail technology as fluid power system for an excavator, to enable the use of the H2 ICE, while improving efficiency. The study is based on simulation in MATLAB/Simulink environment, using duty cycle data from a 24-ton excavator. Simulation results show that in respect to the diesel-powered baseline, the proposed electro-hydraulic hybrid allows the use of a H2 ICE, eliminates CO2 emissions and ensures a 52% fuel consumption reduction.

08 HYDROGEN↗

Towards Net-Zero: Nuclear-Assisted Waste Biomass to Liquid Fuel in Eastern Idaho

A nuclear assisted carbon negative hybrid energy process that enables production of synthetic bio-crude oil and biochar from Eastern Idaho waste biomass is proposed. The process integrates nuclear powered electricity with high temperature steam electrolysis and biomass hydropyrolysis. The bio-crude oil is of sufficient composition and blended with traditional crude oil at a refinery. Hydrogen from the electrolyzer is pressurized and inserted into the pyrolyzer. Non condensable gases generated in the hydropyrolysis process are burned with oxygen from the electrolyzer to produce heat for the electrolyzer, biomass dryer, and pyrolyzer. The biochar is returned to the soil via fertilizer application and remains there for thousands of years. Since the total process uses nuclear generated electricity, the carbon in the biochar is ultimately sequestered from the atmosphere, thus making the process carbon negative. Using Eastern Idaho wheat or barley straw, this hybrid energy process has the potential to provide an alternative petroleum source. Two options exist for the system design: 1) send electricity from the nuclear plant and straw to a chemical processing plant to produce the bio-crude and biochar, 2) construct the biomass processing facility near the nuclear plant to allow use of nuclear-generated process heat to drive the chemical. Process model description and results are discussed. The process is sized to produce gasoline and diesel at the rate that the INL uses every day for fleet usage.

09 BIOMASS FUELS↗

Grid Resilience Analysis on Geothermal District Heating and Cooling Implementation Alongside Four Existing Oil and Gas Wells in Tuttle, Oklahoma: Preprint

This study builds on the existing techno-economic and environmental life cycle assessments performed for a geothermal district heating and cooling system implementation in Tuttle Oklahoma with four existing oil and gas wells. Its resilience in meeting the peak annual heating and cooling loads of the district assuming a temporary disconnection from the electrical grid is assessed both qualitatively and quantitatively. Attributes of resilience and qualitative criteria established by Kolker et al. (2022) for geothermal district heating systems are applied to the proposed case to highlight its vulnerabilities. Results indicate that increasing the redundancy and diversity in the physical configuration of the distributional piping can considerably increase the system’s resilience. A quantitative assessment executed via the REopt tool predicts that the ancillary electricity required to power the geothermal system’s heating and cooling can be met by an onsite emergency diesel generator during times of grid outages for over 28 days.

district heating and cooling↗

Turning a liability into an asset: creating liquid transportation fuels from CO2, natural gas, or RNG

GTI will be discussing our Cool GTL process, a new low cost versatile integrated modular process which can convert CO2, methane, ethane, and biogas, to gasoline jet and diesel with no wax intermediate product. We have tested Cool GTL at small scale and are beginning tests at larger 2 gallon/day scale for biogas conversion ( with DOE funding). Our ultimate goal is to have several commercial deployments of Cool GTL in a variety of applications running in 5 years. Most exciting is the fact that Cool GTL can totally eliminate Global Warming and produce all the worlds transportation fuel by conversion of the excess CO2 currently in the air to liquid transportation fuels, leading to a modern revolution in the way transportation fuels are produced.

09 BIOMASS FUELS↗

Development of a Practical Secondary Control for Hardware Microgrids

Practical, vendor-agnostic interoperability guidelines for the secondary control architecture of microgrids (MGs) with multiple grid-forming (GFM) inverter-based resources (IBRs) have not yet been developed. Therefore, this paper proposes a generic and vendor-agnostic secondary control architecture that operates with all GFM IBRs and synchronous generators. This secondary control does not require the use of additional measurement devices in the MG and utilizes the inherent communication systems of the GFM units, such as Modbus TCP/IP. The practical challenges of Modbus registers, such as packet loss and quantization error, and their detrimental impacts on secondary control actions are investigated. The proposed three-stage modification for any secondary control architecture to mitigate these impacts includes: 1) averaging the data read, 2) situational event-triggering of the controller, and 3) finite iteration of the controlling action. The proposed method is validated using a three-phase electric power, 480 V, 60 Hz, 500 kVA laboratory hardware microgrid with commercial two GFM IBRs and one diesel generator. The experimental results corroborates the fact the proposed modification in the secondary control architecture is advantageous for practical usage under erroneous measurements.

grid-forming inverter↗