Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Detectors Instrumentation Imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 883 records · Page 49

Hyperspectral Infrared Imaging of Flames Using a Spectrally Scanning Fabry-Perot Filter

The temperatures and compositions of gases in and around flames can be diagnosed using infrared emission spectroscopy to observe molecular band shapes and intensities. We have combined this approach with a low-order scanning Fabry-Perot filter and an infrared camera to obtain spectrally scanned infrared emission images of a laboratory flame and exhaust plume from 3.7 to 5.0 micrometers, at a spectral resolution of 0.043 micrometers, and a spatial resolution of 1 mm. The scanning filter or AIRIS (Adaptive Infrared Imaging Spectroradiometer) is a Fabry-Perot etalon operating in low order (mirror spacing = wavelength) such that the central spot, containing a monochromatic image of the scene, is viewed by the detector array. The detection system is a 128 x 128 liquid-nitrogen-cooled InSb focal plane array. The field of view is controlled by a 50 mm focal length multielement lens and an V4.8 aperture, resulting in an image 6.4 x 6.4 cm in extent at the flame and a depth of field of approximately 4 cm. Hyperspectral images above a laboratory CH4/air flame show primarily the strong emission from CO2 at 4.3 micrometers, and weaker emissions from CO and H2O. We discuss techniques to analyze the spectra, and plans to use this instrument in microgravity flame spread experiments.

Rawlins, W. T.↗

High Precision Sunphotometer using Wide Dynamic Range (WDR) Camera Tracking

The NASA Ames Sun-photometer-Satellite Group, DOE, PNNL Atmospheric Sciences and Global Change Division, and NASA Goddards AERONET (AErosol RObotic NETwork) team recently collaborated on the development of a new airborne sunphotometry instrument that provides information on gases and aerosols extending far beyond what can be derived from discrete-channel direct-beam measurements, while preserving or enhancing many of the desirable AATS features (e.g., compactness, versatility, automation, reliability). The enhanced instrument combines the sun-tracking ability of the current 14-Channel NASA Ames AATS-14 with the sky-scanning ability of the ground-based AERONET Sunsky photometers, while extending both AATS-14 and AERONET capabilities by providing full spectral information from the UV (350 nm) to the SWIR (1,700 nm). Strengths of this measurement approach include many more wavelengths (isolated from gas absorption features) that may be used to characterize aerosols and detailed (oversampled) measurements of the absorption features of specific gas constituents. The Sky Scanning Sun Tracking Airborne Radiometer (3STAR) replicates the radiometer functionality of the AATS14 instrument but incorporates modern COTS technologies for all instruments subsystems. A 19-channel radiometer bundle design is borrowed from a commercial water column radiance instrument manufactured by Biospherical Instruments of San Diego California (ref, Morrow and Hooker)) and developed using NASA funds under the Small Business Innovative Research (SBIR) program. The 3STAR design also incorporates the latest in robotic motor technology embodied in Rotary actuators from Oriental motor Corp. having better than 15 arc seconds of positioning accuracy. Control system was designed, tested and simulated using a Hybrid-Dynamical modeling methodology. The design also replaces the classic quadrant detector tracking sensor with a wide dynamic range camera that provides a high precision solar position tracking signal as well as an image of the sky in the 45 field of view around the solar axis, which can be of great assistance in flagging data for cloud effects or other factors that might impact data quality.

aerosols↗

Early Calibration and Performance Assessments of NOAA-20 VIIRS Thermal Emissive Bands

The Visible Infrared Imaging Radiometer Suite (VIIRS) sensor aboard the NOAA-20 (previously JPSS-1) spacecraft has successfully operated since its launch in November, 2017. Similar to the first VIIRS instrument on the Suomi-NPP spacecraft, data is collected in 22 spectral bands that are calibrated by a set of onboard calibrators. This paper provides an overview of the NOAA-20 VIIRS on-orbit operation and calibration, with a particular focus on the thermal emissive bands (TEBs). Results presented in this paper include the on-orbit changes in the TEB spectral band responses, detector noise characterization, and key calibration parameters, such as the non-linear coefficients derived from the blackbody warm-up cool-down cycle. Other issues, such as the early mission long-wave infrared (LWIR) response degradation due to icing on the dewar window, and their impact on sensor calibration are also discussed. Since launch, the VIIRS instrument temperature has been stable to within ± 0.8K and the cold focal plane temperatures are well controlled with variations less than 40 mK. With the exception of the early degradation observed in the LWIR bands, the TEB gains have been stable to within 0.04% (except I5 at 0.07%). Based on the current performance, VIIRS is expected to meet its calibration requirements throughout its design lifetime.

NEdT↗

Optical Imaging and Radiometric Modeling and Simulation

OPTOOL software is a general-purpose optical systems analysis tool that was developed to offer a solution to problems associated with computational programs written for the James Webb Space Telescope optical system. It integrates existing routines into coherent processes, and provides a structure with reusable capabilities that allow additional processes to be quickly developed and integrated. It has an extensive graphical user interface, which makes the tool more intuitive and friendly. OPTOOL is implemented using MATLAB with a Fourier optics-based approach for point spread function (PSF) calculations. It features parametric and Monte Carlo simulation capabilities, and uses a direct integration calculation to permit high spatial sampling of the PSF. Exit pupil optical path difference (OPD) maps can be generated using combinations of Zernike polynomials or shaped power spectral densities. The graphical user interface allows rapid creation of arbitrary pupil geometries, and entry of all other modeling parameters to support basic imaging and radiometric analyses. OPTOOL provides the capability to generate wavefront-error (WFE) maps for arbitrary grid sizes. These maps are 2D arrays containing digital sampled versions of functions ranging from Zernike polynomials to combination of sinusoidal wave functions in 2D, to functions generated from a spatial frequency power spectral distribution (PSD). It also can generate optical transfer functions (OTFs), which are incorporated into the PSF calculation. The user can specify radiometrics for the target and sky background, and key performance parameters for the instrument s focal plane array (FPA). This radiometric and detector model setup is fairly extensive, and includes parameters such as zodiacal background, thermal emission noise, read noise, and dark current. The setup also includes target spectral energy distribution as a function of wavelength for polychromatic sources, detector pixel size, and the FPA s charge diffusion modulation transfer function (MTF).

Ha, Kong Q.↗

Initial Determination of the NOAA-20 VIIRS Screen Transmittances with Both Yaw Maneuver and Regular on Orbit Data

One of the scientific instruments aboard the NOAA-20 satellite is the Visible Infrared Imaging Radiometer Suite (VIIRS). The VIIRS regularly performs on-orbit radiometric calibration of its reflective solar bands, primarily through observations of an onboard sunlit solar diffuser (SD). The incident sunlight passes through an attenuation screen (the SD screen) and scatters off the SD to provide a radiance source for the calibration. The on-orbit change of the SD bidirectional reflectance distribution function (BRDF), denoted as the H-factor, is determined by an onboard solar diffuser stability monitor (SDSM). The eight SDSM detectors observe the sun through another attenuation screen (the SDSM screen) and the sunlit SD almost at the same time to measures the SD BRDF change. The products of the SD screen transmittance and the BRDF at t=0 and the SDSM screen transmittance were measured prelaunch. Large undulations in the H-factor were seen when using the prelaunch screen transmittances. Fifteen on-orbit yaw maneuvers were performed to validate and to further characterize the screens. Although significantly improved, the H-factor from the yaw maneuver data determined screen transmittance still has undulations as large as about 0.7-0.8%, revealing that the angular step size of the yaw maneuvers is too large. In this paper, we add regular on-orbit data to the yaw maneuver data to further improve the relative products and the relative SDSM screen transmittance. The H-factor time series derived from the newly determined screen transmittance is much smoother than that derived from using only the yaw maneuver data and thus improves considerably the radiometric calibration accuracy.

Lei, Ning↗

A Method To Characterize Metalenses For Light Collection Applications

Metalenses and metasurfaces are promising emerging technologies that could improve light collection in light collection detectors, concentrating light on small area photodetectors such as silicon photomultipliers. Here we present a detailed method to characterize metalenses to assess their efficiency at concentrating monochromatic light coming from a wide range of incidence angles, not taking into account their imaging quality.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Oxygen Isotopic Composition of Refractory Inclusions from the Miller Range (MIL) 090019 Carbonaceous Chondrite

Introduction: Primitive meteorites contain Calcium-Aluminum-rich Inclusions (CAIs)that preserve the records of the earliest times in the Solar System. CAIs record O isotopic variations with time and/or location from solar (16O-rich) to planetary (16O-poor) compositions [e.g., 1, 2].However, CAIs were also affected by parent body processing to varying degrees. The goal of this work was to identify the processes that resulted in the fine-scale spatial variations in oxygen isotopic compositions within the most ancient Solar System solids. We report oxygen isotopic composition of CAIs from MIL 090019 CO3.1 carbonaceous chondrite. MIL 090019 contains a high abundance of CAIs showing mineralogical as well as textural variations [3]. Methods: We analyzed 10 CAIs with different mineralogical assemblages, classified as corundum-bearing, grossite-bearing, hibonite-bearing, melilite-bearing, anorthite-bearing inclusions and amoeboid olivine aggregates(AOA’s). The mineralogical and petrological characterization of CAIs was performed using the JOEL Hyperprobe 8530 electron microprobe at NASA JSC. Oxygen isotopic imaging of the CAIs was done using the Cameca NanoSIMS 50L ion microprobe at NASA JSC. We followed the analytical protocol described in [4]. O-isotopic maps of the CAI were acquired by rastering a ~3 pA primary Cs+beam at 16 keVover an area of 20 ×20μm2over a period of ~7 hours. Negative secondary ions of 16O−, 17O−, 18O−, 28Si−, 24Mg16O−, 27Al16O−, and 40Ca16O−were simultaneously acquired using electron multiplier detectors at a mass resolving power sufficient to resolve the 16OH−interference from the 17O−peak, where the contribution of 16OH−was <0.1%.An electron flood gun was used to mitigate sample charging during the analyses. We used San Carlos olivine and Madagascar hibonite as isotopic standards to correct for the instrumental mass fractionation. The O-isotopic ratios were corrected for the quasi simultaneous arrival (QSA) effect and the detector dead time. All reported errors are 1 sigma. Results: The MIL 090019 carbonaceous chondrite hosts refractory inclusions varying in their mineralogies and textures[2, 3]. We found the oxygen isotopic compositions of mineral phases in MIL 090019 CAIs show large variations with Δ17O values varying from -27 to 0‰. A corundum-bearing inclusion records isotopic variations with corundum, melilite, perovskite, and anorthite showing Δ17Ovalues of -20 ±2.5, -10.2 ± 6.5, -10.7 ± 1.3,and -1.2 ± 3.2‰ respectively. A grossite-hibonite-bearing inclusion also records O-isotopic heterogeneity, where grossite, hibonite, Mg-rich spinel, and melilite show -3.7 ± 2.7, -22.9 ± 2.5, -21.4 ± 2.6, and -17.3 ± 2.8‰ respectively, whereas perovskite grains record a heterogenous isotopic composition ranging from -22.6 to -13.9‰. A hibonite-bearing inclusion shows average Δ17Ο values of -17.6 ± 5.3 ‰ and -15.1 ± 4.8 ‰ for hibonite and spinel respectively. The two perovskite grains also show relatively 16O-poor composition (Δ17Ο = -11.8 ± 6.4 ‰ and -8.6 ± 5.2 ‰). Anorthite has ~0.1 wt% Na2O and ~0.52 wt% FeO and a Δ17Ο value of -7.2 ± 5.0 ‰, whereas diopside records a Δ17Ο value of -3.5 ± 5.0 ‰. A hibonite-spinel-rich inclusion contains spinel and hibonite that are16O-rich (Δ17Οvalues -21.3 ± 2.8‰ and -19.4 ± 3.0‰, respectively). Melilite shows heterogenous oxygen isotopic composition, with an inner 16O-rich region and an outer 16O-poor region separated by a sharp boundary, with a bulk Δ17Ο= -16.2 ± 2.1‰, whereas two perovskite grains are relatively 16O-poor (Δ17Ο= -13.2 ± 3.7‰ and -7.1 ± 3.4‰).A spinel-rich inclusion contains perovskite grains with Δ17Οranging from -27.0 to -22.8 ‰and spinel with average Δ17Οvalue of -21.4 ± 2.8 ‰. In a melilite and spinel-rich CAI, perovskite, spinel, diopside, melilite, and Al-Ti-rich pyroxene record Δ17Ο values of-26.9 ± 4.6‰, -22.4 ± 4.3‰,-23.4 ± 4.9, -19.3 ± 3.4, and -19.0 ± 4.3 ‰ respectively. Olivine and spinel components of 2 AOA’s record a 16O-rich composition with Δ17O~-23‰. Discussion: The coexistence of 16O-rich and 16O-poor minerals within CAIs has been attributed to differing degrees of O isotopic exchange, reflecting a wide range of O diffusion rates[5]. However, the O isotopic heterogeneity observed in these CAIs cannot be explained by oxygen diffusion in nebular or parent body settings alone. The isotopic imaging of CAIs from the MIL 090019 meteorite shows variations in the O isotopic composition recorded in their mineral components, suggesting that these CAIs record the oxygen isotopic heterogeneity in the nebular gas from which they condensed. The coexistence of 16O-rich and 16O-poor mineral components in the CAI-forming region suggests that the gas in this region was not well-mixed and consisted of distinct 16O-rich and 16O-poor gaseous reservoirs.

P Mane↗

A hard X-ray imaging instrument for solar and cosmic sources

A hard X-ray imaging instrument is described which is capable of high-resolution imaging of solar and cosmic hard X-ray sources between 2 and 80 keV during Shuttle sortie flights. The properties of solar burst sources and the resulting instrument requirements are discussed. The instrument envelope of 1.2 x 1.2 x 3.0 meters includes a tungsten multigrid collimator which has 4-arcsec resolution, a 40-arcmin response envelope and a point-source effective area of 26 sq cm. A combination of periodic fan beams and nonperiodic pencil beams enables a unique deconvolution to be achieved within a 128 x 128 arcsec field without mechanical scanning. The detector system is a set of direct-readout 40 atm-cm xenon-filled proportional counters designed to minimize background. The instrument is capable of refurbishment to optimize the collimator configuration for specific solar or cosmic scientific objectives, to upgrade the angular resolution, or to extend the high-energy response.

Hurford, G. J.↗

A new high-speed IR camera system

A multi-organizational team at the Goddard Space Flight Center is developing a new far infrared (FIR) camera system which furthers the state of the art for this type of instrument by the incorporating recent advances in several technological disciplines. All aspects of the camera system are optimized for operation at the high data rates required for astronomical observations in the far infrared. The instrument is built around a Blocked Impurity Band (BIB) detector array which exhibits responsivity over a broad wavelength band and which is capable of operating at 1000 frames/sec, and consists of a focal plane dewar, a compact camera head electronics package, and a Digital Signal Processor (DSP)-based data system residing in a standard 486 personal computer. In this paper we discuss the overall system architecture, the focal plane dewar, and advanced features and design considerations for the electronics. This system, or one derived from it, may prove useful for many commercial and/or industrial infrared imaging or spectroscopic applications, including thermal machine vision for robotic manufacturing, photographic observation of short-duration thermal events such as combustion or chemical reactions, and high-resolution surveillance imaging.

Travis, Jeffrey W.↗

A Study of the Non-Thermal X-ray Emission of Shell-Type Supernova Remnants

The term of the forth year of the award is the period from March 15, 2003 to March 14, 2004. During this year, Dr. Thomas Pannuti, who had been performing most of the analyses, made a transition to a new position at Caltech. As of September 2003, Dr. Michael Stage began performing most of the analyses. Dr. Stage has begun constructing a detailed catalog of the spatial and spectral properties of young supernova remnants as described in sections 1 and 4 of the proposal. Specifically, he has focused on the analysis of Chandra ACIS data. The exquisite spatial resolution of the Chandra telescope and the modest spectral resolution of the CCDs make these data ideal. Dr. Stage has developed a standard set of procedures to reduce the data, generate telescope and detector response libraries and handle instrumental and celestial background subtraction. He has also adapted some existing code to automate spectral extraction and fitting. This code enables us to analyze the spectra of tens of thousands of small subregions of supernova remnants. Dr. Stage has recently applied this process to ACIS data for the supernova remnants Cas A and Kepler. The results include maps of the fitted parameters, such as individual line intensities and centroids (i.e. Doppler shifts), the electron temperature, and the absorption column density. These maps are more accurate than simple energy-cut images because it is difficult (and sometimes impossible) to cleanly separate the line emission from the underlying continuum (especially at low energies). It is now possible to identify the locations at which emission from each element is produced. Some of the elements are seen to be layered. The electron temperature maps demonstrate that the outer edges of Cas A and Kepler are very hot with weak lines. This emission is almost certainly synchrotron dominated. Therefore, not only are the maps interesting in and of themselves, but they also provide an unbiased means of easily identifying features in the remnants that can be studied in more detail using, for example, synchrotron models. Over the next year, Dr. Stage will refine the analysis procedures, expand the analyses to include several other remnants, present the results at major scientific conferences and publish a catalog of the results. Since this work is producing impressive results, we have applied for very long Chandra observations of Kepler and Tycho to obtain enough counts to take lull advantage of the technique. A i Ms observation of Cas A is already scheduled. Over the past year, I completed a joint, spectra,l analysis of some X-ray, radio, and gamma-ray data for the supernova remnant SN 1006. The results of this analysis show that the synchrotron and, hence, electron spectrum of the remnant is curved. The amount of curvature in the electron spectrum is quantitatively consistent with predictions of the amount of curvature in the proton spectrum of the remnant. A paper describing this work is nearly complete. When Dr. Pannuti left, he was analyzing X-ray data for the young supernova remnant G266.2-1.2. Dr. Pannuti found the first evidence of thermal X-ray emission from this remnant. Furthermore, like SN 1006, the cutoff frequency varies with azimuth along the bright northeastern rim. This work will be published during the coming year.

Allen, Glenn E.↗

Machine learning for imaging Cherenkov detectors

Imaging Cherenkov detectors are largely used in modern nuclear and particle physics experiments where cutting-edge solutions are needed to face always more growing computing demands. This is a fertile ground for AI-based approaches and at present we are witnessing the onset of new highly efficient and fast applications. This paper presents novel directions with applications to Cherenkov detectors. In particular, recent advances on detector design and calibration, as well as particle identification are presented.

47 OTHER INSTRUMENTATION↗

JPL airborne instruments activities

Two instruments intended for flight aboard aircraft for research in advanced remote sensing of the earth are under development: the airborne imaging spectrometer (AIS) and the airborne visible-infrared imaging spectrometer (AVIRIS). The AIS utilizes a 32 x 32 element HgCdTe CCD array to gather 10nm spectral data, initially in the 1.2 to 2.4 micron range, with 32 pixels of cross-track spatial data. The instrument acquires 128 channels of spectral data by using a grating spectrometer whose grating is stepped through four positions during a fraction of an IFOV time on the ground. With an IFOV of 2 mrad, the GIFOV at the design altitude of 3 km is 6m. The instrument has several on-board processing capabilities including ax+b corrections for detector calibration, cross-track and down-track pixel summing, spectral band summing, and variable integration time to allow flight at various altitudes and velocities. The AVIRIS uses a proven scanning mechanism to acquire the spatial data in a whisk broom mode. The spectral coverage is from 0.35 to 2.5 microns at bandwidths ranging from 10 to 20 nm.

Vane, G.↗

The Large UV/Optical/Infrared Surveyor (LUVOIR): Decadal Mission Concept Technology Development Overview

The Large Ultraviolet / Optical / Infrared (LUVOIR) Surveyor is one of four large mission concept studies being developed by NASA for consideration in the 2020 Astrophysics Decadal Survey. LUVOIR will support a broad range of science objectives, including the direct imaging and spectral characterization of habitable exoplanets around sun-like stars, the study of galaxy formation and evolution, the epoch of reionization, star and planet formation, and the remote sensing of Solar System bodies. The LUVOIR Science and Technology Definition Team (STDT) has tasked a Technology Working Group (TWG), with more than 60 members from NASA centers, academia, industry, and international partners, with identifying technologies that enable or enhance the LUVOIR science mission. The TWG has identified such technologies in the areas of Coronagraphy, Ultra-Stable Opto-mechanical Systems, Detectors, Coatings, Starshades, and Instrument Components, and has completed a detailed assessment of the state-of-the-art. We present here a summary of this technology assessment effort, as well as the current progress in defining a technology development plan to mature these technologies to the required technology readiness level (TRL).

Decadal Study; Technology; LUVOIR↗

First Results from Laser-Based Spectral Characterization of Landsat 9 Operational Land Imager-2

Landsat 9 will continue the Landsat data record into its fifth decade with launch scheduled for December 2020. The two instruments on Landsat 9 are Thermal Infrared Sensor-2 (TIRS-2) and Operational Land Imager-2 (OLI-2). OLI-2 is a nine-channel pushbroom imager with a 15-degree field of view that will have a 16-day measurement cadence from its nominal 705-km orbit altitude. A key aspect of the data that will be produced by OLI-2 is its spectral fidelity which enables countless science applications. The prelaunch test campaign for spectral characterization of OLI-2 was substantially improved relative to the methodology used for OLI: the full spectral response of every detector was characterized with greater accuracy, sampling, and precision. This paper will describe how this was accomplished with a tunable laser-based light source called Goddard Laser for Absolute Measurement of Radiance (GLAMR).

tunable laser↗

A gaseous RICH detector for SiD or ILD

This paper describes a preliminary study of a gaseous Ring Imaging Cherenkov (RICH) system capable of discriminating between kaons and pions at high momenta — up to 50 GeV/c — and thus enhancing particle identification at future colliders. The system possesses a compact design, facilitating easy integration into existing detector concepts. Here, a study of the key contributions to the Cherenkov angle resolution is also presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Two 28-nm front-end ASICs for ultra-fine spatial resolution and precision timing to be 3D integrated with 12 LGADs

The 3DIntSenS Collaboration—a joint effort between SLAC, Fermilab, and LLNL—is developing enabling technologies for next-generation radiation imaging detectors that combine ultra-fine spatial resolution (about 10 µm) with precision timing (<20 ps), while maintaining low power <1 W/cm2 and high data throughput. The approach leverages 3D integration between advanced CMOS readout ASICs and finely pixelated LGAD sensors to achieve the performance and scalability required for large-area, high-rate applications. High-granularity, precision-timing detectors are essential for scientific advances in HEP, NP, BES, and FES, but widespread adoption is limited by the cost and complexity of 3D integration. To close this gap, the collaboration is developing LGAD sensors compatible with 12-inch commercial CMOS processes, enabling cost-effective integration with high-performance ASICs under development. We present two 28 nm CMOS ASIC prototypes, including a low-jitter front end, and in-pixel TDC demonstrating sub-10 ps timing resolution. These advances represent a critical step toward scalable, high-resolution radiation imaging systems for future scientific instrumentation.

England, Troy [Fermilab] (ORCID:0000000154405255)↗

Two 28-nm front-end ASICs for ultra-fine spatial resolution and precision timing to be 3D integrated with 12 LGADs

The 3DIntSenS Collaboration—a joint effort between SLAC, Fermilab, and LLNL—is developing enabling technologies for next-generation radiation imaging detectors that combine ultra-fine spatial resolution (about 10 µm) with precision timing (<20 ps), while maintaining low power <1 W/cm2 and high data throughput. The approach leverages 3D integration between advanced CMOS readout ASICs and finely pixelated LGAD sensors to achieve the performance and scalability required for large-area, high-rate applications. High-granularity, precision-timing detectors are essential for scientific advances in HEP, NP, BES, and FES, but widespread adoption is limited by the cost and complexity of 3D integration. To close this gap, the collaboration is developing LGAD sensors compatible with 12-inch commercial CMOS processes, enabling cost-effective integration with high-performance ASICs under development. We present two 28 nm CMOS ASIC prototypes, including a low-jitter front end, and in-pixel TDC demonstrating sub-10 ps timing resolution. These advances represent a critical step toward scalable, high-resolution radiation imaging systems for future scientific instrumentation.

England, Troy [Fermilab] (ORCID:0000000154405255)↗

Recent Results from the Swift Burst Alert Telescope

The Burst Alert Telescope (BAT) on the Swift Gamma-Ray Burst MIDEX mission has detected more than 125 gamma-ray bursts (GRBs), nearly all of which have been followed up by the narrow-field instruments on Swift through automatic repointing, and by ground and other satellite telescopes after rapid notification. Within seconds of a trigger the BAT produces and relays to the ground a position good to three arc minutes and a four channel light curve. An overview of the properties of BAT bursts and BAT'S performance as a burst monitor will be presented in this talk. BAT is a coded aperture imaging system with a wide (approx.2 sr) field of view consisting of a large coded mask located 1 m above a 5200 sq cm array of 32.768 CdZnTe detectors. All electronics and other hardware systems on the BAT have been operating well since commissioning and there is no sign of any degradation on orbit. The flight and ground software have proven similarly robust and allow the real time localization of all bursts and the rapid derivation of burst light curves, spectra and spectral fits on the ground.

Krimm, Hans↗