Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Data Transfer”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 883 records · Page 49

Short interval testing of solar cells

A drawback of conventional electrical evaluation procedures regarding solar cells is related to time consuming operations required in the determination of specific parameters, such as the maximum power point, from the plotted curves, and to the transfer of data to a large digital computer for analysis and manipulation. This is especially true when large numbers of cells must be measured. To overcome such drawbacks, a digital short interval tester was designed and constructed. The new tester provides rapid and accurate measurements at constant temperature. The utilization of a light shutter makes it possible to measure up to 200 data points along the I-V curve in less than a second, thus avoiding thermal effects. Because the system is digital, parameters such as the maximum power may be calculated directly from the data.

Saylor, C. R.↗

The deep lunar electrical conductivity profile - Structural and thermal inferences

Simultaneous lunar surface and orbital magnetometer records are reexamined, to ascertain intervals which may be suitable for measuring lunar inductive response in the solar wind and terrestrial magnetosheath. Power spectral estimates of the response tangent to the lunar surface, defined in terms of transfer and gain functions, are obtained for the 0.0001-0.01 Hz frequency range. The maximum consistency of estimates from different time intervals is found when the initial analysis is limited to the tangential direction of maximum incident power, or that direction in which the ratio of signal to background noise is greatest. Spherically symmetric plasma confinement theory is used in the interpretation of transfer function data, by way of forward model calculations, under the assumption of continuous electrical conductivity increase with depth. Results are presented for internal electrical conductivity profile, metallic core radius, and selenotherm limits.

Hood, L. L.↗

Further efforts to limit lunar internal temperatures from electrical conductivity determinations

A representative set of 18 electrical conductivity profiles consistent with lunar transfer function data in the 0.00001 to 0.001 Hz range is generated by means of a Monte Carlo procedure. Laboratory electrical conductivity vs temperature data extrapolated to lower and higher temperatures are used to convert the 18 profiles into temperature profiles for a series of radially homogeneous olivine-pyroxene mixtures ranging from 100% olivine to 100% aluminous orthopyroxene. The former yields selenotherms approaching the Ringwood-Essene solidus at depths near 500 km, while additions of the latter in concentrations greater than 15-30 vol% leads to cooler selenotherms which approach the solidus only at depths greater than about 1000 km. On the basis of independent geophysical constraints, the profile envelopes for compositions containing more than 15-30 vol% aluminous orthopyroxene are considered to be the most probable.

Hood, L. L.↗

Reconstruction of a 3-dimensional transonic rotor flow field from holographic interferogram data

Holographic interferometry and computer-assisted tomography (CAT) are used to determine the transonic velocity field of a model rotor blade in hover. A pulsed ruby laser recorded 40 interferograms with a 2-ft-diam view field near the model rotor-blade tip operating at a tip Mach number of 0.90. After digitizing the interferograms and extracting fringe-order functions, the data are transferred to a CAT code. The CAT code then calculates the perturbation velocity in seeral planes above the blade surface. The values from the holography-CAT method compare favorably with previously obtained numerical computations in most locations near the blade tip. The results demonstrate the technique's potential for three-dimensional transonic rotor flow studies.

Yu, Y. H.↗

Investigation of cosmic rays in very short time scales

A fast databuffer system, where cosmic ray events in the Turku hadron spectrometer, including particle arrival times are recorded with time resolution of 100 ns was constructed. The databuffer can be read continuously by a microprocessor, which preanalyzes the data and transfers it to the main computer. The time span, that can be analyzed in every detail, is a few seconds. The high time resolution enables a study of time correlated groups of high energy particles. In addition the operational characteristics of the spectrometer can be monitored in detail.

Peltonen, J.↗

Heating rate distributions at Mach 10 on a circular body earth-to-orbit transport vehicle

A 0.0055-scale model of a single-stage-to-orbit transport vehicle with a circular body configuration was tested at Mach 10 to obtain heat transfer measurements and surface flow patterns. Phase-change paint and oil-flow tests were performed in the Langley 31-Inch Mach-10 Tunnel at angles of attack from 20 through 40 deg in 5-deg increments. Heat-transfer coefficient data are given for all angles of attack, and detailed oil-flow photographs are presented for windward and leeward surfaces at 25 and 40 deg angle of attack. Heating was found to similar to that previously determined for the Space Shuttle Orbiter, so that existing thermal protection systems would appear to be adequate for the proposed circular-body configurations.

Wells, W. L.↗

Three-dimensional, transonic rotor flow field reconstructed from holographic interferogram data

Holographic interferometry and computer-assisted tomography (CAT) are used to determine the transonic flow field of a model rotor blade in hover. A pulsed ruby laser records 40 interferograms with a 61 cm-diam view field near the model rotor-blade tip operating at a tip Mach number of 0.90. After digitizing the interferograms and extracting fringe-order functions, the data are transferred to a CAT code. The CAT code then calculates pressure coefficients in several planes above the blade surface. The values from the holography-CAT method compare favorably with previously obtained numerical computations and laser velocimeter measurements at most locations near the blade tip. The results demonstrate the technique's potential for three-dimensional transonic rotor flow studies.

Kittleson, J. K.↗

Reconstruction of a three-dimensional, transonic rotor flow field from holographic interferogram data

Holographic interferometry and computer-assisted tomography (CAT) are used to determine the transonic velocity field of a model rotor blade in hover. A pulsed ruby laser recorded 40 interferograms with a 2-ft-diam view field near the model rotor-blade tip operating at a tip Mach number of 0.90. After digitizing the interferograms and extracting fringe-order functions, the data are transferred to a CAT code. The CAT code then calculates the perturbation velocity in several planes above the blade surface. The value from the holography-CAT method compare favorably with previously obtained numerical computations in most locations near the blade tip. The results demonstrate the technique's potential for three-dimensional transonic rotor flow studies.

Yu, Y. H.↗

Reconstruction of a three-dimensional, transonic rotor flow field from holographic interferogram data

Holographic interferometry and computerized aided tomography (CAT) are used to determine the transonic velocity field of a model rotor blade in hover. A pulsed ruby laser recorded 40 interferograms with a 2 ft dia view field near the model rotor blade tip operating at a tip Mach number of 0.90. After digitizing the interferograms and extracting the fringe order functions, the data are transferred to a CAT code. The CAT code then calculates the perturbation velocity in several planes above the blade surface. The values from the holography-CAT method compare favorably with previously obtained numerical computations in most locations near the blade tip. The results demonstrate the technique's potential for three dimensional transonic rotor flow studies.

Kittleson, John K.↗

An optical communication link on the Shuttle

A communication link for the transfer of data between the crew cabin and payload bay of the Shuttle is proposed. The configuration of the system, which is to transmit data optically through the Shuttle cabin window, is described. The effects of temperature cycling and cosmic radiation on optical fibers, the cable, connectors, and lenses, and of vibrations during a mission on the alignment of collimating lenses at the window are investigated. Consideration is given to determining the optimum design for the optical fiber and the optimum system operation wavelength for transmission through the aft Orbiter window and the payload environment.

Grady, Jane L.↗

Automatic Range Changer For SWR Meter

Commercial unit modified for antenna-pattern measurements. Addition of automatic range-changing circuit converts Hewlett-Packard 415E standing-wave-ratio (SWR) meter into radio-frequency detector suitable for computer-controlled measurements of radiation patterns of antennas. Modification gives SWR meter effective dynamic range of at least 40 dB. Includes two digital lines communicating one of four range settings to controlling computer and one digital line to inhibit transfer of data when range being changed. Ideal instrument for use in applications involving computer-controlled monitoring of power when large changes in signal level expected.

Dengler, Robert J.↗

The US Experiments Flown on the Soviet Biosatellite Cosmos 1887

Cosmos 1887, a biosatellite containing biological and radiation experiments from the Soviet Union, the United States and seven other countries, was launched on September 29, 1987. One Rhesus monkey's feeder stopped working two days into the flight and a decision was made to terminate the mission after 12 1/2 days. The biosatellite returned to Earth on October 12, 1987. A system malfunction, during the reentry procedure, caused the Cosmos 1887 spacecraft to land approximately 1800 miles beyond the intended landing site and delayed the start of the postflight procedures by approximately 44 hours. Further information on the conditions at landing and postflight activities is included in the Mission Operations portion of this document. U.S. and U.S.S.R. specialists jointly conducted 26 experiments on this mission, including the postflight transfer of data, hardware and biosamples to the U.S.

Connolly, James P.↗

Fast interpolation schemes for moving grids

Search algorithms are developed for efficiently locating interpolation points to facilitate transfer of data in moving grid and related problems. Applications in the construction of adaptive grids and in the solution of problems on composite grids are included.

Mastin, C. Wayne↗

Model for human use of motion cues in vehicular control

A feedback model for human use of motion cues in tracking and regulation tasks is offered. The motion cue model is developed as a simple extension of a structural model of the human pilot, although other equivalent dynamic representations of the pilot could be used in place of the structural model. In the structural model,it is hypothesized that proprioceptive cues and an internal representation of the vehicle dynamics allow the human to create compensation characteristics that are appropriate for the dynamics of the particular vehicle being controlled. It is shown that an additional loop closure involving motion feedback can improve the pilot/vehicle dynamics by decreasing high-frequency phase lags in the effective open-loop system transfer function. Data from a roll-attitude tracking/regulation task conducted on a moving base simulator are used to verify the modeling approach.

Hess, Ronald A.↗

Comparison of CNES spherical and NASA hemispherical large aperture integrating sources. I - Using a laboratory transfer spectroradiometer. II - Using the SPOT-2 satellite instruments

CNES spherical and NASA hemispherical large aperture calibration sources are examined using a laboratory transfer spectroradiometer and SPOT-2 instruments. The sources, collected at Matra in France during October 1987, are compared in terms of absolute calibration, linearity, and uniformity. The laboratory transfer spectroradiometer data reveal that the calibration results correspond to within about 7 percent absolute accuracy level and the linearity of the CNES source with lamp level is good. It is observed using the satellite data that both sources have an excellent uniformity over a 4 deg field of view.

Guenther, B.↗

Interface Circuit For Printer Port

Electronic circuit, called printer-port interface circuit (PPI) developed to overcome certain disadvantages of previous methods for connecting IBM PC or PC-compatible computer to other equipment. Has both reading and writing modes of operation. Very simple, requiring only six integrated circuits. Provides for moderately fast rates of transfer of data and uses existing unmodified circuit card in IBM PC. When used with appropriate software, circuit converts printer port on IBM PC, XT, AT, or compatible personal computer to general purpose, 8-bit-data, 16-bit address bus that connects to multitude of devices.

Tucker, Jerry H.↗