Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “DIFFRACTION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 883 records · Page 49

Extracting information from X-ray diffraction patterns containing Laue oscillations

The presence of Laue oscillations in a film grown on a solid surface is broadly taken as indicating a high quality, crystallographically aligned film of the targeted compound. In this paper we briefly review the origins of both Laue oscillations and Kiessig fringes and show how they can be used together to determine if extra thickness exists above or below the coherently diffracting domains. The differences between experimental and “ideal” films are discussed and the effect of structural features (roughness, different thickness coherently diffracting domains and thickness in addition to the coherently diffracting domains) are illustrated with experimental and simulated data for metal and mixed-metal chalcogenide films of titanium, bismuth, vanadium/iron, and bismuth/molybdenum. Examples are given showing how quantitative information can be extracted from experimental diffraction patterns.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

X-ray Diffraction and Neutron Scattering Analysis of Natural and Synthetic Spider Silk Fibers

Spider silks have the potential to provide new bio-inspired materials for numerous applications in bioenergetics and products ranging from protective clothing to artificial ligaments and tendons. A number of spider silk genes have been cloned and sequenced by the Lewis laboratory revealing the basis for understanding the key elements of spider silk proteins with respect to their materials performance. In particular, specific amino acid motifs have been identified which have been conserved for over 125 million years in all spiders that use their silk to physically trap prey. The key element in taking the next step toward generating bio-based materials from spider silks will be to move from the current descriptive data to predictive knowledge. Current efforts are focused on mimicking spider silk through synthetic proteins. In developing synthetic silk fibers, we first need to understand the complete secondary and tertiary structure of natural silk so that we can compare synthetic constructs to the natural material. Being able to compare the structure on a single fiber level is critical to the future of molecular directed mimic development because we can vary mechanical properties by different spinning methods. The new generation of synchrotron x-ray diffraction and neutron beamlines will allow, for the first time, determination of the molecular structure of silk fibers and synthetic mimics. We propose an exciting new collaborative research team working jointly between Argonne National Laboratory, Arizona State U. and the University of Wyoming to address the ?characterization of synthetic and natural spider silk fibers using x-ray and neutron diffraction.? Thus these new methodologies will provide understanding of current fibers and determine changes needed to produce fibers with specific properties. The following specific aims are proposed: ? Synthesize spider silk fibers with molecular structures mimicking that of natural silks. Test the mechanic properties of these materials and compare them to natural silk fibers. ? Develop x-ray and neutron diffraction techniques to better determine the structure in amorphous and semicrystalline biopolymers, such as spider silk fibers. ? Combine mechanical testing and structural x-ray and neutron diffraction data to develop a molecular understanding of the structure-function relationship in spider silk materials. ? Elucidate the role water plays in spider silk fiber formation and structure. Emphasis will be placed on combined neutron and NMR studies. ? Use solid-state Nuclear Magnetic Resonance (NMR) to characterize synthetic and natural spider silk materials that show potential as a biomimetic material or bio-inspired polymer architecture. ? Develop EPSCoR student and postdoctoral training and exposure to national laboratory facilities. ? Further develop scientific outreach and chemical education programs and research.

36 MATERIALS SCIENCE↗

Diffraction-Based Optical Switching with MEMS

In this article, we are presenting an overview of MEMS-based (Micro-Electro-Mechanical System) optical switch technology starting from the reflective two-dimensional (2D) and three-dimensional (3D) MEMS implementations. To further increase the speed of the MEMS from these devices, the mirror size needs to be reduced. Small mirror size prevents efficient reflection but favors a diffraction-based approach. Two implementations have been demonstrated, one using the Texas Instruments DLP (Digital Light Processing), and the other an LCoS-based (Liquid Crystal on Silicon) SLM (Spatial Light Modulator). These switches demonstrated the benefit of diffraction, by independently achieving high speed, efficiency, and high number of ports. We also demonstrated for the first time that PSK (Phase Shift Keying) modulation format can be used with diffraction-based devices. To be truly effective in diffraction mode, the MEMS pixels should modulate the phase of the incident light. We are presenting our past and current efforts to manufacture a new type of MEMS where the pixels are moving in the vertical direction. The original structure is a 32 x 32 phase modulator array with high contrast grating pixels, and we are introducing a new sub-wavelength linear array capable of a 310 kHz modulation rate

36 MATERIALS SCIENCE↗

X-Ray Diffraction under Extreme Conditions at the Advanced Light Source

The more than a century-old technique of X-ray diffraction in either angle or energy dispersive mode has been used to probe materials’ microstructure in a number of ways, including phase identification, stress measurements, structure solutions, and the determination of physical properties such as compressibility and phase transition boundaries. The study of high-pressure and high-temperature materials has strongly benefitted from this technique when combined with the high brilliance source provided by third generation synchrotron facilities, such as the Advanced Light Source (ALS) (Berkeley, CA, USA). Here we present a brief review of recent work at this facility in the field of X-ray diffraction under extreme conditions, including an overview of diamond anvil cells, X-ray diffraction, and a summary of three beamline capabilities conducting X-ray diffraction high-pressure research in the diamond anvil cell.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

SU(3) Gauge Symmetry: An Experimental Review of Diffractive Physics in e+p, p+p, p+ A, and A+A Collision Systems

This review focuses on diffractive physics, which involves the long-range interactions of strong nuclear force at high energies described by SU(3) gauge symmetry. It is expected that diffractive processes account for nearly 40% of the total cross-section at LHC energies. These processes consist of soft-scale physics where perturbation theory cannot be applied. Although highly successful and often described as a perfect theory, quantum chromodynamics relies heavily on perturbation theory, a model best suited for hard-scale physics. The study of pomerons could help bridge the soft and hard processes and provide a complete description of the theory of the strong interaction across the full momentum spectrum. Here, we will discuss some of the features of diffractive physics, experimental results from SPS, HERA, and the LHC, and where the field could potentially lead. With the recent publication of the odderon discovery in 2021 by the D0 and TOTEM collaborations and the new horizon of physics that lies ahead with the upcoming Electron-Ion Collider at Brookhaven National Laboratory, interest is seemingly piquing in high energy diffractive physics.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Characterization of a Test for Invasive Breast Cancer Using X-ray Diffraction of Hair—Results of a Clinical Trial

Objective: To assess the performance of a test for breast cancer utilizing synchrotron x-ray diffraction analysis of scalp hair from women undergoing diagnostic radiology assessment. Design and Setting: A double-blinded clinical trial of women who attended diagnostic radiology clinics in Australia. Patients: 1796 women referred for diagnostic radiology, with no previous history of cancer. Main Outcome Measures: Sensitivity, specificity and accuracy of the hair test analysis compared to the gold standard of imaging followed by biopsy where indicated. Results: The hair-based assay had an overall accuracy of > 77% and a negative predictive value of 99%. For all women, the sensitivity of both mammography and X-ray diffraction alone was 64%, but when used together the sensitivity rose to 86%. The sensitivity of the hair test for women under the age of 70 was 74%. Conclusion: In this large population trial the association between the presence of breast cancer and an altered hair fiber X-ray diffraction pattern previously reported has been confirmed. It appears that mammography and X-ray diffraction of hair detect different populations of breast cancers, and are synergistic when used together.

60 APPLIED LIFE SCIENCES↗

Effects of diffraction and static wavefront errors on high-contrast imaging from the Thirty Meter Telescope

High-contrast imaging, particularly direct detection of extrasolar planets, is a major science driver for the next generation of extremely large telescopes such as the segmented Thirty Meter Telescope. This goal requires more than merely diffraction-limited imaging, but also attention to residual scattered light from wavefront errors and diffraction effects at the contrast level of 10-8-10-9. Using a wave-optics simulation of adaptive optics and a diffraction suppression system we investigate diffraction from the segmentation geometry, intersegment gaps, obscuration by the secondary mirror and its supports. We find that the large obscurations pose a greater challenge than the much smaller segment gaps. In addition the impact of wavefront errors from the primary mirror, including segment alignment and figure errors, are analyzed. Segment-to-segment reflectivity variations and residual segment figure error will be the dominant error contributors from the primary mirror. Strategies to mitigate these errors are discussed.

segmented mirrors↗

Determining the diffraction properties of a cylindrically bent KAP(001) crystal from 1 to 5 keV

Various crystals are used for the dispersive component of X-ray spectrometers. The crystals are usually bent to meet the desired measurement needs, such as focusing. The bending can change the crystal diffraction properties, thus altering the spectrometer throughput and resolving power. This work concerns measuring the diffraction properties of a potassium acid phthalate (001) [KAP(001)] crystal bent into a circular cylinder segment. The measurement methods using a diode source and a synchrotron source are described. The multi-lamellar model for calculating the diffraction properties of a bent crystal is described. The measurement results are compared to the multi-lamellar model and show qualitative agreement. The measurements show how to make the multi-lamellar calculations a useful estimate. A method is given to make useful estimates of the diffraction properties of the KAP(001) crystal bent into a circular cylinder segment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Diffractive and Exclusive Production at the Tevatron

Exclusive Higgs production, in which the event consists of nothing but the leading protons and a Higgs boson, has been proposed as a channel in which to study the properties of the Higgs boson at the Large Hadron Collider (LHC). Although we do not expect to observe exclusive Higgs-boson production at the Tevatron, we can observe similar processes which provide a calibration for theoretical predictions of exclusive Higgs production at the LHC. The CDF measurements of exclusive dijet and diphoton production, examples of such processes, are presented in Sec. 2. Single diffraction has been studied extensively at the Tevatron in Run I, including diffractive dijet and W/Z-boson production. New results with extended kinematical reach allowed by the larger Run II dataset are presented in Sec. 3. CDF II includes forward detectors designed for studying diffractive physics. The MiniPlug calorimeters cover the pseudorapidity region 3.5<|{eta}|<5.1. Beam Shower Counters (BSC) surrounding the beampipe in several locations detect particles in the forward region 5.4<|{eta}|<7.4. A spectrometer consisting of three Roman-pot detectors preceded by Tevatron dipoles is used to track diffractive antiprotons which have lost a fraction 0.03<{zeta}<0.10 of the beam momentum.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

CDF experimental results on diffraction

Experimental results on diffraction from the Fermilab Tevatron collider obtained by the CDF experiment are reviewed and compared. We report on the diffractive structure function obtained from dijet production in the range 0 < Q{sup 2} < 10,000 GeV{sup 2}, and on the |t| distribution in the region 0 < |t| < 1 GeV{sup 2} for both soft and hard diffractive events up to Q{sup 2} {approx} 4,500 GeV{sup 2}. Results on single diffractive W/Z production, forward jets, and central exclusive production of both dijets and diphotons are also presented.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Neutron and X-Ray Diffraction Studies of Advanced Materials

The selection of articles in the special topic 'Neutron and X-Ray Studies of Advanced Materials' is based on the materials presented during the TMS 2009 annual meeting in San Francisco, CA, February 15-19, 2009. The development of ultrabrilliant third-generation synchrotron X-ray sources, together with advances in X-ray optics, has created intense X-ray microbeams, which provide the best opportunities for in-depth understanding of mechanical behavior in a broad spectrum of materials. Important applications include ultrasensitive elemental detection by X-ray fluorescence/absorption and microdiffraction to identify phase and strain with submicrometer spatial resolution. X-ray microdiffraction is a particularly exciting application compared with alternative probes of crystalline structure, orientation, and strain. X-ray microdiffraction is nondestructive with good strain resolution, competitive or superior spatial resolution in thick samples, and with the ability to probe below the sample surface. Moreover, the high-energy X-ray diffraction technique provides an effective tool for characterizing the mechanical and functional behavior in various environments (temperature, stress, and magnetic field). At the same time, some neutron diffraction instruments constructed mainly for the purpose of engineering applications can be found at nearly all neutron facilities. The first generation-dedicated instruments designed for studying in-situ mechanical behavior have been commissioned and used, and industrial standards for reliable and repeatable measurements have been developed. Furthermore, higher penetration of neutron beams into most engineering materials provides direct measurements on the distribution of various stresses (i.e., types I, II, and III) beneath the surface up to several millimeters, even tens of millimeters for important industrial components. With X-ray and neutron measurements, it is possible to characterize material behavior at different length scales. It is predicted that the application of these techniques, in combination with theoretical simulations and numerical modeling, will lead to major breakthroughs in materials science in the foreseeable future, which will contribute to the development of materials technology and industrial innovation. Specifically, the use of these techniques provides bulk material properties that further augment new characterization tools including the increased use of atom probe tomography and high-resolution transmission electron microscopy systems. The combination of these techniques greatly assists the material property models that address multi-length-scale mechanisms. Different applications of diffuse scattering for understanding the fundamental materials properties are illustrated in the articles of Welberry et al., Goossens and Welberry, Campbell, Abe et al., Gilles et al., and Zhang et al. Analysis of thin films and two-dimensional structures is described in the articles of Gramlich et al., Brock et al., Vigliante et al., Kuzel et al., and Davydok et al. Recent advances in the line profile analysis are represented by the the articles of Scardi et al., Ungar et al., and Woo et al. Characterization of modern alloys is presented by the articles of Wollmershauser et al., Eidenberger et al., Garlea et al., Jia et al., Soulami et al., Wilson et al., and Wang et al. The collected articles are written by different scientific X-ray and neutron research groups. They represent a general trend in the development and application of diffraction techniques all over the world.

36 MATERIALS SCIENCE↗

Real-time X-ray Diffraction Measurements of Shocked Polycrystalline Tin and Aluminum

A new, fast, single-pulse x-ray diffraction (XRD) diagnostic for determining phase transitions in shocked polycrystalline materials has been developed. The diagnostic consists of a 37-stage Marx bank high-voltage pulse generator coupled to a needle-and-washer electron beam diode via coaxial cable, producing line and bremsstrahlung x-ray emission in a 35-ns pulse. The characteristic Kα lines from the selected anodes of silver and molybdenum are used to produce the diffraction patterns, with thin foil filters employed to remove the characteristic Kβ line emission. The x-ray beam passes through a pinhole collimator and is incident on the sample with an approximately 3-mm by 6-mm spot and 1° full-width-half-maximum (FWHM) angular divergence in a Bragg-reflecting geometry. For the experiments described in this report, the angle between the incident beam and the sample surface was 8.5°. A Debye-Scherrer diffraction image was produced on a phosphor located 76 mm from the polycrystalline sample surface. The phosphor image was coupled to a charge-coupled device (CCD) camera through a coherent fiberoptic bundle. Dynamic single-pulse XRD experiments were conducted with thin foil samples of tin, shock loaded with a 1-mm vitreous carbon back window. Detasheet high explosive with a 2-mm-thick aluminum buffer was used to shock the sample. Analysis of the dynamic shock-loaded tin XRD images revealed a phase transformation of the tin beta phase into an amorphous or liquid state. Identical experiments with shock-loaded aluminum indicated compression of the face-centered-cubic (fcc) aluminum lattice with no phase transformation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Strain evolution in Si substrate due to implantation of MeV ion observed by extremely asymmetric x-ray diffraction

We studied the strain introduced in a Si(111) substrate due to MeV ion implantation using extremely asymmetric x-ray diffraction and measured the rocking curves of asymmetrical 113 diffraction for the Si substrates implanted with a 1.5 MeV Au{sup 2+} ion at fluence values of 1x10{sup 13}, 5x10{sup 13}, and 1x10{sup 14}/cm{sup 2}. The measured curves consisted of a bulk peak and accompanying subpeak with an interference fringe. The positional relationship of the bulk peak to the subpeak and the intensity variation of those peaks with respect to the wavelengths of the x rays indicated that crystal lattices near the surface were strained; the lattice spacing of surface normal (111) planes near the surface was larger than that of the bulk. Detailed strain profiles along the depth direction were successfully estimated using a curve-fitting method based on Darwin's dynamical diffraction theory. Comparing the shapes of resultant strain profiles, we found that a strain evolution rapidly occurred within a depth of approx300 nm at fluence values between 1x10{sup 13} and 5x10{sup 13}/cm{sup 2}. This indicates that formation of the complex defects progressed near the surface when the fluence value went beyond a critical value between 1x10{sup 13} and 5x10{sup 13}/cm{sup 2} and the defects brought a large strain to the substrate.

36 MATERIALS SCIENCE↗

Mn incorporation into the GaAs lattice investigated by hard x-ray photoelectron spectroscopy and diffraction

Photoelectron spectroscopy and diffraction have been used to investigate structural changes during the annealing process of Ga{sub 1-x}Mn{sub x}As samples. Hard x-ray radiation helped in observing photoelectron core-level spectra and electron diffraction from the bulk underlying the oxidized surface layer. High electron-energy resolution enabled us to separate the components due to substitutional and interstitial Mn atoms in the intrinsic Mn 2p{sub 3/2} photoemission profile, resulting in two peaks at 638.8 and 639.5 eV binding energy, respectively. The peaks display the known characteristic behavior after annealing, that is, an almost complete reduction of the interstitial component and preservation of the substitutional component. In the photoelectron diffraction, a sensitivity of high-energy polar plots to the incorporation sites of photoemitting atoms into the atomic lattice has been shown. As a consequence, the experimental polar plots from substitutional and interstitial Mn atoms, which are supported theoretically, show characteristic features that provide structural information. From the similarities and differences of the polar plots for Mn and Ga, we have confirmed the assignment of components within the intrinsic part of the photoemission Mn 2p{sub 3/2} signal suggested by photoelectron spectroscopy.

36 MATERIALS SCIENCE↗

Inversion of Many-Beam Bragg Intensities for Phasing by Iterated Projections: Removal of Multiple Scattering Artifacts from Diffraction Data

An iterated projection algorithm (N-Phaser) is developed that reconstructs a scattering potential from N-beam multiple Bragg scattered intensities. The method may be used to eliminate multiple scattering artifacts from electron diffraction data, solving the phase problem and increasing the thicknesses of samples used in materials science, solid-state chemistry, and small molecule crystallography. For high-energy transmission electron diffraction, we show that the algorithm recovers accurate complex structure factors from a wide range of thicknesses, orientations, and relativistic beam energies, and does not require known thickness or atomic-resolution data if sufficient multiple scattering occurs. Furthermore, extensions to Cryo-electron microscopy and Micro-electron diffraction are suggested.

36 MATERIALS SCIENCE↗

Neutron diffraction: a primer

Because of the neutron’s special properties, neutron diffraction may be considered one of the most powerful techniques for structure determination of crystalline and related matter. Neutrons can be released from nuclear fission, from spallation processes, and also from low-energy nuclear reactions, and they can then be used in powder, time-of-flight, texture, single crystal, and other techniques, all of which are perfectly suited to clarify crystal and magnetic structures. With high neutron flux and sufficient brilliance, neutron diffraction also excels for diffuse scattering, for in situ and operando studies as well as for high-pressure experiments of today’s materials. For these, the wave-like neutron’s infinite advantage (isotope specific, magnetic) is crucial to answering important scientific questions, for example, on the structure and dynamics of light atoms in energy conversion and storage materials, magnetic matter, or protein structures. In this primer, we summarize the current state of neutron diffraction (and how it came to be), but also look at recent advances and new ideas, e.g., the design of new instruments, and what follows from that.

36 MATERIALS SCIENCE↗

Combined high-pressure neutron and X-ray diffraction study of H-D substitution effects on brucite

The high-pressure behavior of the mineral brucite, Mg(OH){sub 2}, is of great geochemical and geophysical interest, because brucite-type minerals serve as a simple analog for more complex, hydrogen-bearing oxide and silicate minerals in the deep-earth. A combined neutron and synchrotron x-ray powder diffraction study of hydrogenated and deuterated brucite was conducted at ambient temperature and at pressures to 9 and 20 GPa, using a Paris-Edinburgh (neutron diffraction) and a diamond anvil cell (synchrotron x-ray radiation), respectively. The two materials were synthesized by the same method and companion diffraction measurements of the two materials were conducted under the same conditions. Our experimental results show that the lattice-parameters of the a axis, parallel to the sheets of Mg-O octahedra, decrease only slightly with pressure with no effect of H-D substitution. However, the c axis of Mg (OD){sub 2} is shorter and may exhibit greater compressibility with pressure than that of Mg (OH){sub 2}. Consequently, the unit-cell volume of deuterated brucite is slightly, but systematically smaller than that of hydrogenated brucite. Fitting to a third-order Birch-Murnaghan equation shows that values of the bulk modulus for hydrogenated and deuterated brucite are indistinguishable from each other within the experimental errors. The measured effect of H-D substitution on the unit-cell volume demonstrates that brucite (and other hydrous minerals) preferentially incorporate deuterium over hydrogen under pressure, suggesting that the distribution of hydrogen isotopes in deep-earth conditions may differ significantly from that in near-surface environments.

36 MATERIALS SCIENCE↗

The quantum evolutions of the diffractive transverse-momentum dependent gluon distribution

Using the Colour Glass Condensate description of electron-nucleus collisions at high energy, we study the diffractive production of a pair of jets with transverse momenta much larger than the nuclear saturation momentum Q s . At leading order in the QCD coupling, the di-jet cross-section exhibits transverse-momentum dependent (TMD) factorisation, with a gluon diffractive TMD distribution (DTMD) which is controlled by gluon saturation and describes the transverse-momentum imbalance between the produced jets. The next-to-leading corrections generate the various quantum evolutions of the diffractive gluon distribution. We focus on the Collins-Soper-Sterman (CSS) evolution which describes the change in the gluon DTMD when increasing the “hard scale” (the typical transverse momentum of the di-jets). We consider two different representations for this equation, one in transverse-momentum space, the other one in transverse-coordinate space. They are not fully equivalent with each other (despite being related by a Fourier transform) because of the respective boundary conditions. These conditions encode the essential physics of gluon saturation together with the effects of two other types of quantum evolution: the BK/JIMWLK evolution over the rapidity gap (“inside the Pomeron”) and the DGLAP evolution outside the rapidity gap (“within the diffractive system”). We demonstrate that, due to gluon saturation, one can compute both the boundary conditions and the CSS solutions mostly from first principles, without the need for a non-perturbative Sudakov. We numerically find a good agreement between the CSS solutions in the two aforementioned representations.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗