Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Comparative Study”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 883 records · Page 49

A comparative reactivity study of 1-alkene fuels from ethylene to 1-heptene

In this work, a comparative reactivity study of 1-alkene fuels from ethylene to 1-heptene has been performed using ignition delay time (IDT) measurements from both a high-pressure shock tube and a rapid compression machine, at an equivalence ratio of 1.0 in ‘air’, at a pressure of 30 atm in the temperature range of 600–1300 K. At low temperatures (< 950 K), the results show that 1-alkenes with longer carbon chains show higher fuel reactivity, with 1-pentene being the first fuel to show negative temperature coefficient (NTC) behavior followed by 1-hexene and 1-heptene. At high temperatures (> 950 K), the experimental results show that all of the fuels except propene show very similar fuel reactivity, with the IDTs of propene being approximately four times longer than for all of the other 1-alkenes. To analyze the experimental results, a chemistry mechanism has been developed using consistent rate constants for these alkenes. At 650 K, flux analyses show that hydroxyl radicals add to the double bond, followed by addition to molecular oxygen producing hydroxy-alkylperoxy radicals, which can proceed via the Waddington mechanism or alternate internal H-atom isomerizations in chain branching similar to those for alkanes. We have found that the major chain propagation reaction pathways that compete with chain branching pathyways mainly produce hydroxyl rather than hydroperoxyl radicals, which explains the less pronounced NTC behavior for larger 1-alkenes compared to their corresponding alkanes. At 1200 K, flux analyses show that the accumulation of hydroperoxyl radicals is important for the auto-ignition of 1-alkenes from propene to 1-heptene. The rate of production of hydroperoxyl radicals for 1-alkenes from 1-butene to 1-heptene is higher than that for propene, which is due to the longer carbon chain facilitating hydroperoxyl radical formation via more efficient reaction pathways. This is the major reason that propene presents lower fuel reactivity than the other 1-alkenes at high temperatures.

1-Alkene↗

SU-F-T-27: A Comparative Case Study Among Four Modalities for the Superficial Treatment of Squamous Cell Carcinoma

Purpose: We performed a comparative planning study among High Dose Rate (HDR) brachytherapy, superficial electrons, Volume Modulated Arc Therapy (VMAT), and Helical IMRT (Tomotherapy) for squamous cell carcinoma of the abdominal wall with consideration for the underlining bowel. Methods: A 69-year old female presented with squamous cell carcinoma protruding 8mm beyond the anterior skin surface of the midabdomen was considered for treatment. The patient had a ventral hernia which resulted in the reduction of the abdominal wall thickness and the adjacent small bowel being the dose limiting structure. Four plans were generated using different treatment modalities: a) an enface electron field (eMC, Eclipse v. 11), b) Tomotherapy (HI-Art II v.5.0.5), c) VMAT (Acuros, Eclipse v. 11), and d) HDR using a Freiburg applicator (Oncentra v. 4.3). The following plan objectives were used for all four plans: for the CTV target, V90% ≥90% (61.8Gy2/2).For the small bowel, D0.1cc < 56.2 Gy2/2 was a hard constraint and expressed as a percentage of the prescription for comparison to demonstrate the dose fall-off achieved among the modalities.For HDR, V200% <0.1cc was an additional constraint. Multiple dosimetric parameters, including those listed above, were compared among the four modalities. Results: The HDR plan showed comparable target coverage compared to the Tomotherapy plan and better coverage compared to the electron plan. Small bowel doses (D0.1cc) were lower in HDR plan compared to Tomotherapy, electron, & VMAT plans (88.8%, 89.6%, 90.9%, & 96.6%). Integral dose to the whole body (V5%) was much higher for HDR, VMAT, and Tomotherapy when compared to electron plan by factors of seven, eight, and ten, respectively. After reviewing all treatment modalities, the physician selected HDR owing to better control of the small bowel dose while maintaining adequate target coverage. Conclusion: This case study demonstrated HDR can successfully treat superficial lesions with superior sparing of underlying structures.

60 APPLIED LIFE SCIENCES↗

A comparative experimental study of the hygroscopic and mechanical behaviors of electrospun nanofiber membranes and solution–cast films of polybenzimidazole

This article reports a comparative experimental study of the hygroscopic and mechanical behaviors of electrospun polybenzimidazole (PBI) nanofiber membranes and solution-cast PBI films. As-electrospun nonwoven PBI nanofiber mats (with the nanofiber diameter of ~250 nm) were heat-pressed under controlled temperature, pressure and duration for the study; lab-made solution-cast PBI films and commercially available PBI films (the PBI Performance Product Inc., Charlotte, NC) were used as the control samples. Thermogravimetric and microtensile tests were utilized to characterize the hygroscopic (moisture absorption) and mechanical properties of the PBI nanofiber membranes at varying heat-pressing conditions, which were further compared to those of solution-cast PBI films. Experimental results indicated that the PBI nanofiber membranes carried slightly higher thermal stability and less hygroscopic properties than those of solution-cast PBI films. In addition, heat-pressing conditions significantly influenced the mechanical properties of the resulting PBI nanofiber membranes. The stiffness and tensile strength increase with increasing either the heat-pressing pressure or duration, and relevant mechanisms were explored. Here, the present study provides a rational understanding of the hygroscopic and mechanical behaviors of electrospun PBI nanofiber membranes and solution-cast PBI films that are beneficial to their reliable cutting-edge applications in high-temperature filtration, polymer electrolyte membranes (PEMs), etc.

25 ENERGY STORAGE↗

Postoperative radiotherapy following mastectomy for patients with left-sided breast cancer: A comparative dosimetric study

The purposes of this article were to compare the biophysical dosimetry for postmastectomy left-sided breast cancer using 4 different radiotherapy (RT) techniques. In total, 30 patients with left-sided breast cancer were randomly selected for this treatment planning study. They were planned using 4 RT techniques, including the following: (1) 3-dimensional conventional tangential fields (TFs), (2) tangential intensity-modulated therapy (T-IMRT), (3) 4 fields IMRT (4F-IMRT), and (4) single arc volumetric-modulated arc therapy (S-VMAT). The planning target volume (PTV) dose was prescribed 50 Gy, the comparison of target dose distribution, conformity index, homogeneity index, dose to organs at risk (OARs), tumor control probability (TCP), normal tissue complication probability (NTCP), and number of monitor units (MUs) between 4 plans were investigated for their biophysical dosimetric difference. The target conformity and homogeneity of S-VMAT were better than the other 3 kinds of plans, but increased the volume of OARs receiving low dose (V{sub 5}). TCP of PTV and NTCP of the left lung showed no statistically significant difference in 4 plans. 4F-IMRT plan was superior in terms of target coverage and protection of OARs and demonstrated significant advantages in decreasing the NTCP of heart by 0.07, 0.03, and 0.05 compared with TFs, T-IMRT, and S-VMAT plan. Compared with other 3 plans, TFs reduced the average number of MUs. Of the 4 techniques studied, this analysis supports 4F-IMRT as the most appropriate balance of target coverage and normal tissue sparing.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Phylogenetic diversity in the genus Bacillus as seen by 16S rRNA sequencing studies

Comparative sequence analysis of 16S ribosomal (r)RNAs or DNAs of Bacillus alvei, B. laterosporus, B. macerans, B. macquariensis, B. polymyxa and B. stearothermophilus revealed the phylogenetic diversity of the genus Bacillus. Based on the presently available data set of 16S rRNA sequences from bacilli and relatives at least four major "Bacillus clusters" can be defined: a "Bacillus subtilis cluster" including B. stearothermophilus, a "B. brevis cluster" including B. laterosporus, a "B. alvei cluster" including B. macerans, B. maquariensis and B. polymyxa and a "B. cycloheptanicus branch".

NASA Discipline Number 52-30↗

Microstructural origin of high‐strength Tyranno SA4 SiC fiber studied by comparative Raman spectroscopy #

Tyranno SA4 grade SiC fiber is an emerging continuous fiber with excellent mechanical properties. The origin of the fiber's high-performance was studied by comparative Raman spectroscopy of four different grades of SiC fibers and reference SiC monolith. Analysis of the Raman spectra of fiber cross-sections, surface and homogeneity, and fibers under stress, revealed how differences in microstructure, such as crystalline order, size, and the presence of critical flaws, dictate mechanical properties. In conclusion, this information can help optimize SiC fiber manufacturing.

36 MATERIALS SCIENCE↗

A Study to Compare the Failure Rates of Current Space Shuttle Ground Support Equipment with the New Pathfinder Equipment and Investigate the Effect that the Proposed GSE Infrastructure Upgrade Might Have to Reduce GSE Infrastructure Failures

The purposes of this study are to compare the current Space Shuttle Ground Support Equipment (GSE) infrastructure with the proposed GSE infrastructure upgrade modification. The methodology will include analyzing the first prototype installation equipment at Launch PAD B called the "Pathfinder". This study will begin by comparing the failure rate of the current components associated with the "Hardware interface module (HIM)" at the Kennedy Space Center to the failure rate of the neW Pathfinder components. Quantitative data will be gathered specifically on HIM components and the PAD B Hypergolic Fuel facility and Hypergolic Oxidizer facility areas which has the upgraded pathfinder equipment installed. The proposed upgrades include utilizing industrial controlled modules, software, and a fiber optic network. The results of this study provide evidence that there is a significant difference in the failure rates of the two studied infrastructure equipment components. There is also evidence that the support staff for each infrastructure system is not equal. A recommendation to continue with future upgrades is based on a significant reduction of failures in the new' installed ground system components.

Kennedy, Barbara J.↗

Hierarchical microstructural parameters governing electrical and thermal conductivity in Al-based eutectic systems

Enhancing conductivity properties of aluminum alloys can drive superior performance and efficiency across diverse engineering applications, yet currently commercially available Al casting alloys are severely limited in electrical and thermal conductivity. There is a general understanding that the presence of any defects and alloying elements within Al will inevitably lower conductivity properties. However, there is a lack of comparative studies evaluating the intricate interplay between the microstructural parameters and conductivity properties across cast Al-based eutectic systems. Therefore, this study bridges this gap by conducting a comparative study across hypoeutectic alloy compositions consisting of 50 % primary Al and 50 % eutectic region to elucidate the key parameters that dictate conductivity properties. This research contributes to advancing the understanding of alloy design opportunities for high conductivity, high strength castable Al alloys.

36 MATERIALS SCIENCE↗

Comparative lubrication studies of OH-58A tail rotor drive shaft bearings

Comparative lubrication tests were run with OH-58A helicopter tail rotor drive shaft bearings. The tests were run in an outdoor environment with ambient temperatures ranging from 10 to 75 F. Dust was periodically applied to the bearings to simulate field conditions. The cause of bearing failure was associated with dust penetration. Rotor shaft failure was found to be caused by the shaft rotating in the standard rubber collar due to seizure of the bearings. Bearings with a positive rubbing seal having a MIL-G-81322 grease produced lives greater than with bearings having labyrinth seals and a mineral oil paste lubricant. An elongated collar prevented failure of the rotor shaft during bearing seizure. In a limited test, installation of tail boom shrouds over the bearings which excluded dust and water resulted in bearing lives in excess of 1800 hours or 1200 hours greater than the current 600 hours TBO, regardless of the lubricant-bearing combination used.

Dietrich, M. W.↗

Comparative experimental study of heat transfer processes in accumulation energy recovery exchangers

In this study, an experimental comparison between three different energy accumulating ceramic heat exchangers for energy recovery in ventilation systems was presented. The units were selected to represent three different approaches on the energy recovery process: honeycomb structure with more accumulation mass (more energy can be stored in one unit)- Unit 1.1, honeycomb structure with lower accumulation mass- Unit 1.2, and a rectangular structure with expanded heat transfer surface- Unit 1.3. The achieved results are useful for the future application of such units in ventilation systems. It was established that all evaluated units demonstrated an acceptable effectiveness of thermal energy recovery from the exhaust air. Their average energy recovery efficiency ranged between 70 % and 80 %, aligning with expected performance benchmarks for regenerative heat exchangers employed in contemporary mechanical ventilation systems. It was also established that the factor which has the highest impact on thermal effectiveness is the heat transfer surface available in the tested heat exchangers. Units with the highest number of channels (i.e., with the highest amount of single channel walls, which can be used for heat transfer) achieve the highest thermal effectiveness. However, higher thermal effectiveness can negatively affect the ventilation potential of the units. Unit 1.3, which was characterized by the highest thermal efficiency, was also characterized by the lowest achievable flow rate. It was also found that the important technical aspect that should be taken into account when analyzing accumulation energy recovery units is also the fluctuation of the supply air temperature. The ability to ensure minimal temperature fluctuations is a significant operational advantage, as it ensures a higher level of safety at lower outside temperatures.

Energy recovery↗

Reproducibility of the cutoff probe for the measurement of electron density

Since a plasma processing control based on plasma diagnostics attracted considerable attention in industry, the reproducibility of the diagnostics using in this application has become a great interest. Because the cutoff probe is one of the potential candidates for this application, knowing the reproducibility of the cutoff probe measurement becomes quit important in the cutoff probe application research. To test the reproducibility of the cutoff probe measurement, in this paper, a comparative study among the different cutoff probe measurements was performed. The comparative study revealed remarkable result: the cutoff probe has a great reproducibility for the electron density measurement, i.e., there are little differences among measurements by different probes made by different experimenters. The discussion including the reason for the result was addressed via this paper by using a basic measurement principle of cutoff probe and a comparative experiment with Langmuir probe.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A comparative experimental study of IOR potential in fractured shale reservoirs by cyclic water and nitrogen gas injection

Oil production from tight and shale formations accounted for more than half of total U.S. oil production in 2015 (EIA, 2016). Such amount is expected to grow significantly as the active development of low permeability reservoirs continues. Since the primary recovery is becoming less effective and large amounts of oil are locked in matrix, IOR techniques should be considered to face such challenge. Many recent studies have evaluated the potential of gas injection in shale plays. However, few studies discussed the feasibility of water huff-n-puff process. Here this study evaluated the potential of cyclic water injection (CWI) in shale plugs and compared it with the performance of cyclic gas injection (CGI). Eagle Ford core samples were used in this study and saturated with dead shale oil. X-ray diffraction (XRD) technique was employed to analyze the mineral composition of the sample. To reduce clay swelling, 5 wt% of potassium chloride (KCl) solution was used as the injection fluid in CWI tests. Two groups of experiments were performed to examine the effects of soaking time and injection pressure (Pin) on the recovery performance. For one cycle of huff-n-puff, after reaching the Pin, the core plug was soaked with water for a certain time, then the surrounding pressure was released to enter the production period. Under the same operating conditions, CGI tests were conducted to compare the two IOR performances. The CWI experimental results show that soaking time affects the recovery factor (RF) of a single cycle within a certain range, which was similarly concluded from the CGI tests. Injection pressure can affect the recovery performance of CWI significantly. For example, after performing 12 cycles of water huff-n-puff, the RF for tests with Pin of 1000 psi and 5000 psi were 14% and 21%, respectively. When applying 5000 psi, fractures were created on the plug and the size enlarged with further cycles operated. Comparing the two processes of CWI and CGI, different recovery characters can be observed. CWI showed the recovery potential at the first four cycles, and then the incremental oil recovery decreased dramatically in the subsequent cycles. By contrast, CGI presented a more continuous and steady recovery performance with high incremental RF, and then gradually diminished after seven cycles of huff-n-puff processes.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Molecule-Adsorbed Topological Insulator and Metal Surfaces: A Comparative First-Principles Study

We compare electronic structure characteristics of three different kinds of benzene-adsorbed (111) surfaces: that of Bi 2 Te 3 , a prototypical topological insulator, that of Au, a prototypical inert metal, and that of Pt, a prototypical catalytic metal. Using first-principles calculations based on dispersion-corrected density functional theory, we show that benzene is chemisorbed on Pt, but physisorbed on Au and Bi 2 Te 3 . Here, the adsorption on Bi 2 Te 3 is particularly weak, consistent with a minimal perturbation of the electronic structure at the surface of the topological insulator, revealed by a detailed analysis of the interaction of the molecular orbitals with the topological surface states.

36 MATERIALS SCIENCE↗

Role of low-energy ion irradiation in the formation of an aluminum germanate layer on a germanium substrate by radical-enhanced atomic layer deposition

Radical-enhanced atomic layer deposition uses oxygen radicals generated by a remote microwave-induced plasma as an oxidant to change the surface reactions of the alternately supplied trimethylaluminum precursor and oxygen radicals on a Ge substrate, which leads to the spontaneous formation of an aluminum germanate layer. In this paper, the effects that low-energy ions, supplied from a remote microwave plasma to the substrate along with the oxygen radicals, have on the surface reactions were studied. From a comparative study of aluminum oxide deposition under controlled ion flux irradiation on the deposition surface, it was found that the ions enhance the formation of the aluminum germanate layer. The plasma potential measured at the substrate position by the Langmuir probe method was 5.4 V. Assuming that the kinetic energy of ions arriving at the substrate surface is comparable to that gained by this plasma potential, such ions have sufficient energy to induce exchange reactions of surface-adsorbed Al atoms with the underlying Ge atoms without causing significant damage to the substrate. This ion-induced exchange reaction between Al and Ge atoms is inferred to be the background kinetics of the aluminum germanate formation by radical-enhanced atomic layer deposition.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Whole breast and excision cavity radiotherapy plan comparison: Conformal radiotherapy with sequential boost versus intensity-modulated radiation therapy with a simultaneously integrated boost

A comparative study was conducted comparing the difference between (1) conformal radiotherapy (CRT) to the whole breast with sequential boost excision cavity plans and (2) intensity-modulated radiation therapy (IMRT) to the whole breast with simultaneously integrated boost to the excision cavity. The computed tomography (CT) data sets of 25 breast cancer patients were used and the results analysed to determine if either planning method produced superior plans. CT data sets from 25 past breast cancer patients were planned using (1) CRT prescribed to 50 Gy in 25 fractions (Fx) to the whole-breast planning target volume (PTV) and 10 Gy in 5Fx to the excision cavity and (2) IMRT prescribed to 60 Gy in 25Fx, with 60 Gy delivered to the excision cavity PTV and 50 Gy delivered to the whole-breast PTV, treated simultaneously. In total, 50 plans were created, with each plan evaluated by PTV coverage using conformity indices, plan maximum dose, lung dose, and heart maximum dose for patients with left-side lesions. CRT plans delivered the lowest plan maximum doses in 56% of cases (average CRT = 6314.34 cGy, IMRT = 6371.52 cGy). They also delivered the lowest mean lung dose in 68% of cases (average CRT = 1206.64 cGy, IMRT = 1288.37 cGy) and V20 in 88% of cases (average CRT = 20.03%, IMRT = 21.73%) and V30 doses in 92% of cases (average CRT = 16.82%, IMRT = 17.97%). IMRT created more conformal plans, using both conformity index and conformation number, in every instance, and lower heart maximum doses in 78.6% of cases (average CRT = 5295.26 cGy, IMRT = 5209.87 cGy). IMRT plans produced superior dose conformity and shorter treatment duration, but a slightly higher planning maximum and increased lung doses. IMRT plans are also faster to treat on a daily basis, with shorter fractionation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Study Of Compressibility Corrections To Turbulence Models

Effects on shear layers in simulated confined and unconfined flows studied. Report presents comparative study of some terms that correct for effects of compressibility in standard k-epsilon mathematical model of turbulence where k denotes turbulence kinetic energy and epsilon denotes rate of dissipation of turbulence kenetic energy. Involved simulation of flows by numerical solution of Reynolds-averaged Navier-Stokes equations.

Viegas, J. R.↗