Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Capacity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 883 records · Page 49

In Situ Ion‐Exchange Metathesis Induced Conformal LiF Surface Films on Cathode (NMC811) as a Cathode Electrolyte Interphase

High-capacity cathodes (LiNi 0.8 Mn 0.1 Co 0.1 O 2 , NMC811) are promising for vehicle electrification because of their high gravimetric energy density. However, their electrochemical performance still relies upon the stability of the cathode electrolyte interphase (CEI). A highly reactive cathode interface leads to parasitic side reactions with electrolytes, resulting in accelerated capacity fading. Well-developed LiF and LiF-like inorganic compounds are believed to be good CEI components for stabilizing such reactive electrode interfaces. However, it is challenging to form an optimal surface sub-nanolayer of LiF on the cathode surfaces because of the complexity of the electrochemical reaction during battery cycling. Herein, the formation of a conformal LiF layer on the NMC811 electrode surface via an in situ ion-exchange metathesis process is reported, demonstrating a promising electrochemical performance because of a LiF-stabilized CEI. In situ generated LiF-coated NMC811 electrodes exhibit ≈97% capacity retention up to 100 cycles at a 0.3 C rate with average coulombic efficiency of ≈99.9% and ≈80% capacity retention up to 200 cycles at a 1 C rate with average coulombic efficiency of >99.6%. This finding may pave the way for reengineering the CEI to enhance the electrochemical performances and cycling stability of the high-capacity cathodes.

25 ENERGY STORAGE↗

Beneficial Effects of La 0.5 Sr 0.5 CoO 3 Coatings on Thin‐Film LiMn 2 O 4 Cathodes for Lithium Ion Batteries

Abstract The severe capacity loss of spinel LiMn 2 O 4 (LMO) limits the utility of this otherwise promising lithium ion battery cathode material. One of the strategies to mitigate capacity fade is applying a coating on LMO particle surfaces. While this approach yields promising results, there is limited understanding of mechanisms whereby coatings improve LMO capacity retention. Herein, the effects of a new protective coating material, La 0.5 Sr 0.5 CoO 3 (LSCO), in a thin‐film battery geometry that is amenable to fundamental studies of electrode processes, are reported. RF sputtering deposition is used to produce high quality 25–100 nm LMO cathodes on Al 2 O 3 substrates with an intervening Pt/Ti back‐side contact layer. Cycling of the un‐coated cathodes results in capacity loss of 18% over 300 cycles. Adding a 2 nm LSCO layer reduces the capacity loss to 3%. While this may be due in part to reduced Mn dissolution, scanning transmission electron microscopy results indicate that the coating helps to preserve crystallinity and reduce lattice structure distortion due to inhibited formation of defect tetragonal spinel. Three‐electrode electrochemical impedance spectroscopy results reveal that the LSCO coating increases charge transfer and ohmic resistances, but the increases are generally too small to significantly impact cell performance even at high C‐rates.

25 ENERGY STORAGE↗

What can surface wind observations tell us about interannual variation in wind energy output?

The past decade of wind power growth was supported by capacity factor improvements and associated cost reductions. But are higher capacity factors a technology success story or, as suggested by recent research, has the influence of technology been overstated by ignoring positive surface wind speed trends? The answer could influence estimates of wind energy's cost and even future deployment rates. We find that US surface wind speed observations imply a 2.6% improvement in capacity factors from 2010 to 2019. Yet newer vintages of wind plants have recorded capacity factors that are ~25% larger than plants built close to 2010. It follows that technological factors and improved site quality, not higher wind speeds, drove most of the improvement in capacity factors. Additionally, we match hundreds of meteorological stations to nearby (< 25 km) wind plants and compare annual estimated generation, based on a function of surface wind speed observations, to annual recorded generation. Researchers rely on this publicly available surface data because measurements co-located with wind plants are generally considered proprietary. Our analysis addresses a research gap: interannual variation in observed surface wind speeds is rarely compared to observed data at wind plant locations and turbine heights. We find that despite its common use for this purpose, generation estimates based on publicly available surface observational data provide a poor proxy for interannual variability in recorded wind generation. These findings suggest that caution is generally needed when researchers use surface wind speed measurements to investigate long-term wind energy trends.

17 WIND ENERGY↗

Assessments of data centers for provision of frequency regulation

There are numerous opportunities for data centers to participate in demand response programs considering their large energy capacities, flexible working environments and workloads, redundant design and operation, etc. As a type of demand response, frequency regulation requires fast response, and its potential is not fully explored by data centers yet. This paper proposes a synergistic control strategy for data center frequency regulation which uses both IT and cooling systems. It combines power management techniques at the server level with control of the chilled water supply temperature to track the regulation signal from the electrical market. A frequency regulation flexibility factor is also proposed to increase the IT capacity for frequency regulation. The performance of the control strategy is studied through numerical simulations using an equation based object-oriented Modelica platform designed for data centers. Simulation results show that with well-tuned control parameters, data centers can provide frequency regulation service in both regulation up and down. The performance of data centers in providing frequency regulation service is largely influenced by the regulation capacity bid, frequency regulation flexibility factor, workload condition, and cooling mode of the cooling system, and not significantly influenced by the time constant of chillers. In addition, compared with a server-only control strategy, the proposed synergistic control strategy can provide an extra regulation capacity of 3% of the design power when chillers are activated. Here, when chillers are deactivated, both strategies have a similar regulation capacity.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Multi-site assessment of the potential of fine resolution red-edge vegetation indices for estimating gross primary production

Gross primary production (GPP) models driven by fine resolution remote sensing data characterize the spatial and temporal heterogeneities in plant photosynthesis, which is largely dependent on biome-specific maximum photosynthetic capacity. The red-edge reflectance, sensitive to leaf chlorophyll content, is a good proxy of maximum photosynthetic capacity. More importantly, studies show that the red-edge reflectance-related chlorophyll content index (CIr) multiplied by the incident photosynthetic active radiation (PAR in ) strongly correlates to GPP estimated at carbon flux towers (GPP flux ). Yet, to the best of our knowledge, there is no systematic study investigating the general relationship between fine spatial resolution CIr and GPP among biomes and the relationship between CIr and maximum photosynthetic capacity in GPP models. To provide an overview on incorporating space-borne CIr into a GPP model, we applied fine resolution Sentinel-2-derived CIr and GPP flux over 57 flux sites representative of 10 biomes. We investigated the relationship between CIr and GPP flux , and the spatio-temporal relationship between CIr and ecosystem maximum photosynthetic capacity indicated by the potential ecosystem light use efficiency (LUE pot ). We also evaluated the relationship between other five vegetation indices (VIs) and GPP flux . Results showed that the CIr multiplied by PARin has a higher agreement (R 2 > 0.5) with GPP than other VIs. A universal relationship exists between the CIr multiplied by PARin and GPP, except for forest biomes. The CIr also strongly (R 2 > 0.5) relates to the LUE pot during the peak of the growing season. The CIr has a low spatial variance (CV = 0.25) among biomes, highlighting that CIr can be a proxy of maximum photosynthetic capacity in GPP models that do not require biome-dependent coefficients. This study provides insight for incorporating CIr into GPP models and better quantifying global terrestrial photosynthesis.

59 BASIC BIOLOGICAL SCIENCES↗

Exploring the benefits of utilizing small modular device for sustainable and flexible shale gas water management

Growing shale gas extraction in recent years has triggered wide discussions on the associated freshwater requirement and wastewater management. Many optimization approaches have been developed for shale gas water management; however, most of the studies assumed permanent utilization of wastewater treatment facilities with fixed capacities. Considering the rapidly declining characteristics of shale gas wastewater production, these treatment facilities could remain largely underutilized after the first few months/years of production, making them less economically attractive. To maximize the capacity utilization of treatment facilities and further improve the economic performance of shale gas development, this study develops a systematic optimization framework, where the capacity strategy of conventional treatment facilities and utilization of the recent concept of modular manufacturing are both considered for flexible shale gas water management. The proposed mixed-integer linear programming (MILP) model simultaneously optimizes the design and planning of integrated shale gas and water supply chain, with a focus on capacity planning for both large-scale conventional treatment facilities and small-scale modular devices. A series of Marcellus-based case studies are performed to illustrate the applicability of the proposed model and provide general insights into the trade-offs between the multiple types of treatment facilities. The optimization results reveal that the combinatorial utilization of conventional facilities and modular devices for wastewater treatment (66% by conventional facilities and 34% by modular devices) brings 9.3% more reused water for other well development and 6.2% savings in water-related costs, compared to flexible management of only conventional facilities. Furthermore, this work suggests that taking modular device as auxiliary equipment for shale gas water management is most beneficial to increase the capacity utilization of treatment facilities and achieve a more economic and sustainable shale gas production system.

04 OIL SHALES AND TAR SANDS↗

Truck platooning in the U.S. national road network: A system-level modeling approach

Truck platooning enables a group of trucks to move close together, which helps reduce truck fuel use and increase effective road capacity. In this paper, a system-level equilibrium model is developed to characterize spontaneous truck platooning with coexistence of non-platooning vehicles in a network, by explicitly accounting for the interlocking relationship among platoon formation time, truck fuel saving, and increase in effective road capacity. To equilibrate the relationships, an algorithm is proposed which involves a diagonalization approach and a bush based algorithm to solve decomposed subproblems. The condition of proportionality is imposed to obtain unique traffic flows for each class of vehicles on road links. In addition, a spatially constrained multivariate clustering technique is employed to construct origin/destination zones that are smaller than the coarse Freight Analysis Framework (FAF) zones, while maintaining reasonable computational burden for network traffic assignment. Model implementation in the U.S. shows that platooning could lead to 7.9% fuel saving among platoonable trucks in 2025 and a comparable increase in effective capacity of platoonable road links, which would account for 60% of rural interstate roads. The fuel saving and road capacity improvement translate into an annual cost reduction of $\$$868 million for the U.S. intercity trucking sector and reduced road infrastructure investment needs worth $\$$4.8 billion. Extensive sensitivity analysis further reveals that fuel saving of platoonable trucks increases with platoon size but decreases with inter-truck distance in a platoon. Fuel saving potential suggests that priority should be given to rural rather than urban roads in deploying platooning technologies. As we expected, greater market penetration of platooning technologies means higher fuel saving and greater increase in effective road capacity.

33 ADVANCED PROPULSION SYSTEMS↗

Quaternary Cu 2 TSiS 4 (T = Fe, Mn) Anodes for Li-Ion Batteries

Developing high-capacity and fast-charging anode materials is critical for achieving high-performance Li-ion batteries (LIBs). Herein, polycrystalline quaternary transition metal silicon sulfides, Cu 2 TSiS 4 (T = Fe, Mn), were synthesized using a solid-state method and investigated as anode materials in LIBs. Cu 2 FeSiS 4 retains a reversible capacity of 670 mAh g –1 at 200 mA g –1 for 400 cycles, while Cu 2 MnSiS 4 suffers from a fast capacity loss in the initial 50 cycles. More importantly, Cu 2 FeSiS 4 can maintain a reversible capacity of 379 mAh g –1 after 700 cycles at a high current density of 2 A g –1 , demonstrating high cyclic stability and fast-charging capacity. To further understand the structure degradation and phase transformation, we investigated the postcycling electrodes using multiple techniques, including the scanning electron microscope with energy-dispersive X-ray spectroscopy, X-ray diffraction, and X-ray photoelectron spectroscopy techniques. The results indicated that Cu 2 FeSiS 4 undergoes reversible phase transitions with Li 2 S as a major product component. To further assess the performance for practical applications, Cu 2 FeSiS 4 was coupled with LiFePO 4 to make LiFePO 4 ||Cu 2 FeSiS 4 full cells, which delivered superior electrochemical performance. These results demonstrate great promise for using quaternary transition metal silicon sulfides as anodes to achieve low-cost and sustainable LIBs.

25 ENERGY STORAGE↗

Computational Elucidation of Mechanical Degradation in NMC Cathodes: Impact on Cell Performance

Next-generation lithium ion batteries are expected to demonstrate superior energy and power density with longer cycle life for successful electrification of the automobile, aviation, and marine industries. Adoption of lithium metal anodes with solid electrolytes can help to achieve that goal given that the dendrite-related issues are solved eventually. Another possibility is to use Ni-rich high-capacity NMC cathode materials with liquid and/or solid electrolytes, which presently experiences rapid capacity fade while charged to higher voltages. Several mechanical and chemical degradation mechanisms are active within these NMC-based cathode particles. Recent experimental research activities attempted to correlate the mechanical damage with the capacity fade experienced by Ni-rich LiNi x Mn y Co z O 2 (x+y+z = 1) (NMC) cathodes. Here, a computational framework is developed in this study capable of quantifying the evolution of inter primary particle and cathode/electrolyte interfacial fracture experienced by the poly- and single-crystalline NMC cathodes during charge/discharge operation. Influences of mechanical degradation on the overall cell capacity, while operating with liquid and/or solid electrolytes, are successfully characterized. Decreasing the size of the cathode primary particles, or the size of the single-crystalline cathodes, can mitigate the overall mechanical degradation, and subsequent capacity fade, experienced by NMC cathodes. The developed theoretical methodology can help the engineers and scientists to better understand the mechanical degradation mechanism prevalent in Ni-rich NMC cathodes and build superior lithium ion-based energy storage devices for the application in next-generation devices.

25 ENERGY STORAGE↗

The Rise of US Photovoltaics: An Exploration of Land Use Density Trends in Large‐Scale Solar Facility Attributes, 2012–2021

An energy transition is underway in the United States; renewable energy generation is now on par with coal and nuclear generation. The number of large-scale solar photovoltaic facilities increased approximately tenfold between 2012 and 2021, with an associated 25-fold increase in cumulative installed capacity. With ambitious decarbonization and renewable energy deployment goals at both the federal and state levels, deployments of large-scale solar photovoltaic facilities will continue apace. This growth is likely to be complex with ripples of impacts felt throughout different aspects of society, and thus accurate solar land use metrics allowing more accurate predictions are of value to policymakers, planners, and other stakeholders in the future photovoltaic build-out. In this paper, we leverage data from the newly released US Large-Scale Solar Photovoltaic Database to examine recent trends in large-scale solar photovoltaic land use. We analyze the relationships between solar array capacity density (W/acre) and a range of facility attributes to better understand the future land requirements of solar capacity expansion over the coming years. Installed capacity was the single strongest determinant of solar array area. However, we found substantial variation in capacity density across facility attributes, including mount type, latitude, urbanicity, time, and prior land use.

14 SOLAR ENERGY↗

Methods for Representing Flexible, Energy-Constrained Technologies in Utility Planning Tools

Capacity expansion models are widely used by power system researchers, planners, and policy analysts to evaluate alternative power system investment scenarios. With the increasing deployment of wind and solar in the US, there has been much focus on improving the representations of variable generation (VG) technologies within capacity expansion models. Models that capture the variable net-load profiles and larger reserve requirements associated with high penetration VG systems represent an improvement to classic capacity expansion models, but fall short of capturing the complexities associated with storage technologies, such as battery energy storage (BES) and concentrating solar power with thermal energy storage (CSP with TES). While difficult to model in a capacity expansion setting, these technologies are potentially competitive sources of flexibility with the intriguing characteristics of being able to absorb VG that would otherwise be curtailed and directly contribute to renewable energy goals, respectively. In this paper we present methods for accurately representing these technologies in a large-scale capacity expansion model with high electrical and geospatial resolution. VG modeling techniques, including novel methods for capturing curtailment due to unit commitment and other hourly dispatch phenomena, are also reviewed. Modeling for a region in the southwestern United States demonstrates the economic relevance of being able to explicitly trade off the costs and capabilities of energy-constrained technologies, especially BES, against other resources in the near-term, in time to make plans for the coming decade

24 POWER TRANSMISSION AND DISTRIBUTION↗

The Roles and Impacts of PV-Battery Hybrids in a Decarbonized U.S. Electricity Supply

In this paper, we explore the potential impacts of growing industry interest in hybrid systems comprising PV and battery technologies on the results and findings of the Solar Futures Study (DOE 2021). We employ similar scenario definitions in the same ReEDS capacity expansion model, but we perform two versions of each scenario: one in which PV and battery technologies must be deployed separately (No Hybrids), and one in which the model has the option of deploying them together as PVB hybrids (With Hybrids). By comparing the No Hybrids and With Hybrids versions of each scenario, we isolate the impacts of hybridization on the outcomes and findings of the Solar Futures Study. We find that PVB hybrid configurations capture a sizable share of PV deployment, and the highest-net-value PVB hybrid configuration depends strongly on policy conditions. A power sector decarbonization policy generally increases the value proposition of a more forward-looking PVB hybrid configuration that involves significant oversizing of the PV arrays, a larger battery (which facilitates greater recovery and utilization of otherwise clipped energy), and a higher capacity factor. The growing deployment of PVB hybrid configurations primarily displaces standalone PV capacity, such that total installed PV capacity is largely unaffected by the availability of PVB hybrid configurations. However, the higher capacity factors associated with PVB hybrid configurations drive a modest (1-2 percentage point) increase in PV's share of U.S. electricity supply in 2050. Finally, introducing the PVB hybrid configurations influences the future role and makeup of battery storage technologies, and it reduces the required transmission expansion, particularly under scenarios that involve a power sector decarbonization policy.

14 SOLAR ENERGY↗

Calista Energy Management Assistance Initiative

The Calista Energy Management Assistance Initiative (CEMAI) provided technical assistance and capacity building for 56 Tribal communities in the Calista Region of Alaska as an effort to reduce costs, improve operational efficiency, enhance human capacity, and job opportunities. CEMAI catalyzed and guided numerous efforts into a consolidated and effective initiative that brought rural energy best practices, economies of scale, operational efficiencies, human capacity, and economic development to the forefront. Calista Corporation (Calista) is one of thirteen Alaska Native Regional Corporations created under the Alaska Native Claims Settlement Act of 1971 (ANCSA) in the settlement of aboriginal land claims. Calista was incorporated in Alaska on June 12, 1972. The Calista Region covers Alaska’s Bethel and Kusilvak (formerly Wade Hampton) Census areas and includes 56 communities. Calista partnered with Nuvista Light and Electric Cooperative (Nuvista) on the Department of Energy, Office of Indian Energy (DOE-OIE), CEMAI project. Nuvista is a non-profit that seeks to reduce energy costs and provide renewable sources of energy to the people of western Alaska. It is founded and led by a non-profit, Tribe, Native Corporations (including Calista), energy organizations, and Alaska Native stakeholders in the Yukon-Kuskokwim Delta (YK-D) Region; covering the same service boundaries and communities served by Calista. This partnership allowed Calista to direct the project work with local energy experts to respond to community needs. In this arrangement, Calista added credibility and regional accountability while Nuvista added energy-specific expertise and skill set in project management. The delivery of the CEMAI Workplan included short-term or on-demand responses to specific technical assistance requests from communities in addition to longer-term strategically directed activities such as workshops, coordinated training, and capacity development efforts across the region. CEMAI’s Workplan aimed to enhance communities’ readiness for establishing renewable energy projects and implementing energy efficiency initiatives. The CEMAI objectives included: (1) Identifying common operational needs and improvement opportunities for entities with an energy interest or responsibility. (2) Providing access to multi-level expertise to address existing challenges. (3) Developing specialized training programs to build local capacity and community readiness. (4) Nurturing the creation of regional support networks. (5) Increasing access to regional, state, and federal energy initiatives, funding, and expertise. (6) Improving technical skills, provide livable wages, and job opportunities.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Economic Evaluation of a Coupled Nuclear Power Plant and Hydrogen Production Facility: A Case Study

This study optimized the design sizes and operation of a power-to-hydrogen-to-power integrated energy system to allow a baseload power plant to operate flexibly in the energy market. In collaboration with a utility industry partner, the system, consisting of an electrolyzer, compressors, storage tank, and fuel cell, was optimized under conditions specific to the proposed project at the site of a nuclear power plant. The Design Integration and Synthesis Platform to Advance Tightly Coupled Hybrid Energy Systems (DISPATCHES) maximized net present value by optimizing sizing of components and dispatch decisions. Revenues included sale of electricity, capacity payments typical of the New York Independent System Operator, and the section 45V hydrogen production tax credit of the Inflation Reduction Act of 2022 (the tax credit was assumed to be available to legacy plants in the absence of clear guidance at present). Under default assumptions which excluded many capital expenditures, the base case optimized solution had a net present value of $\$$1.4 million over a 30 year lifetime, with a 0.365 MW fuel cell operating nearly continuously and 85% of revenues supplied by the hydrogen production tax credit (which was counted as a revenue regardless of profit, thus assuming credit monetization or offset of taxes within the larger firm was possible in all years). Beyond the base case, a sensitivity study elucidated drivers of the economics as capacity payment rate and hydrogen production tax credit rate vary. Additional sensitivity studies also extended results to variation of other, previously fixed parameters, including the fuel cell capital cost, and to imposition of further constraints. Optimization was also repeated for the default assumptions but recognizing tax credits upon use of hydrogen rather than upon its production, producing no change in the optimal solution. Most notably, capacity payments above $\$$15/kW-month drove optimal fuel cells multiple times larger than those with the default estimated capacity payment of $\$$2.5/kW-month (approaching 11 vs. 0.365 MW), and these larger fuel cells operated rarely (capacity factors of ~0.03). Furthermore, when the hydrogen production tax credit was provided for only 10 years, under the specific assumptions of this study (e.g., neither site preparation costs nor electrolyzer capital cost counted), the optimal solution avoided economic loss by ceasing system operation after the 10th year. Viewed broadly, this study demonstrated the capabilities of DISPATCHES, which can be user-adapted to serve other industrial case studies.

08 HYDROGEN↗

Pushing the Limits: Maximizing Energy Density in Silicon Sulfide Solid‐State Batteries

Here, for the first time, we demonstrate a silicon solid-state battery (SSB) architecture that achieves >400 Wh kg −1 , approaching the theoretical limit for silicon-based SSBs. This configuration features a 99.9 wt% micro-Si, a thin sulfide solid electrolyte (SSE), and a high-loading NMC811. Key to these results is strategically selecting and evaluating the processing techniques, whether wet or dry, for the negative electrode, positive electrode and thin sheet-type SSE. Excessive lithium incorporation into the silicon host, beyond the Li 3.75 +Si phase to form a LiSi composite, is essential to match the high capacity of the positive electrode. This SSB achieves over 1000 cycles for a 2 mAh cm −2 with ≈80% capacity retention and 94% capacity retention for 3 mAh cm −2 over 500 cycles at 25 °C. Post analysis identifies the primary capacity decay mechanisms as oxidation at the NMC/SSE interface and structural disruptions within NMC. Meanwhile, the Si electrode maintains a robust solid-electrolyte interphase layer, minimizing capacity decay. This study highlights the necessity for improved NMC coatings, lattice oxygen stabilization, and a durable positive electrode-electrolyte interface to improve the long-term stability of SSBs. Strategies leading to a single-layer pouch cell SSB exceeding 400 Wh kg −1 are developed.

25 ENERGY STORAGE↗

Conformal LiF Stabilized Interfaces via Electrochemical Fluorination on High Voltage Spinel Cathodes (≈4.9 V) for Lithium-Ion Batteries

The high voltage LiNi 0.5 Mn 1.5 O 4 (LNMO) spinel is one of the promising cathodes for the lithium-ion batteries due to its high energy densities, good rate performance. However, its high operating potential (≈4.75 V) causes extensive oxidation of conventional carbonate electrolytes, resulting an unstable and thick cathode electrolyte interphase (CEI) layer with a large irreversible capacity and low coulombic efficiency. In this work, we report the formation of thin LiF stabilized interfaces on LNMO via electrochemical fluorination that significantly improves the cycling stability and enhanced the capacity. An electrochemically induced conformal LiF layer acts as a part of a robust CEI by reducing the leakage of electrons and allowing the conduction of Li ions through it. Because of the robust LiF stabilized CEI, LNMO delivers a discharge capacity of ≈148.5 and ≈117.1 mAh g -1 at 0.1 and 1 C rate, respectively. It exhibits excellent cyclability with 80% capacity retention (CR) after 600 cycles in lithium-half cell and ≈90% CR after 200 cycles in full cell with only 0.03% and 0.05% capacity decay per cycle in conventional carbonate electrolytes without additives. Such an excellent electrochemical performance could lead to the potential development of high energy density batteries with high voltage cathodes for grid-based applications.

25 ENERGY STORAGE↗

Supramolecular Self-Assembled Multi-Electron-Acceptor Organic Molecule as High-Performance Cathode Material for Li-Ion Batteries

Organic electrode materials possess many advantages such as low toxicity, sustainability, and chemical/structural tunability toward high energy density. However, to compete with inorganic-based compounds, crucial aspects such as redox potential, capacity, cycling stability, and electronic conductivity need to be improved. Herein, a comprehensive strategy on the molecular design of small organic electron-acceptor-molecule—hexaazatrianthranylene (HATA) embedded quinone (HATAQ) is reported. By introducing conjugated quinone moieties into the electron-deficient hexaazatriphenylene-derivative core, HATAQ with highly extended π-conjugation can yield extra-high capacity for lithium storage, delivering a capacity of 426 mAh g -1 at 200 mA g -1 (0.4C). At an extremely high rate of 10 A g -1 (19C), a reversible capacity of 209 mAh g -1 corresponding to nearly 85% retention is obtained after 1000 cycles. A unique network of unconventional lock-and-key hydrogen bonds in the solid-state facilitates favorable supramolecular 2D layered arrangement, enhancing cycling stability. To the best of the authors’ knowledge, the capacity and rate capability of HATAQ are found to be the best ever reported for organic small-molecule-based cathodes. Finally, these results together with density functional theory studies provide proof-of-concept that the design strategy is promising for the development of organic electrodes with exceptionally high energy density, rate capability, and cycling stability.

25 ENERGY STORAGE↗