Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CFD modeling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 883 records · Page 49

Numerical Investigation of Fluid Flow and Space Charge in Liquid Argon Time Projection Chamber (LArTPC) Detectors

Overview This project focused on developing a high-fidelity numerical framework to simulate the multiphysics environment within Liquid Argon Time Projection Chamber (LArTPC) detectors. The primary objective was to characterize the complex interplay between ion transport, background fluid dynamics, and electric field distortions—a critical factor for the calibration and sensitivity of next-generation High Energy Physics experiments, such as DUNE. Technical Achievements The research successfully yielded a hybrid numerical space-charge solver utilizing a Cell-Centered Finite Volume Method (FVM) for ion transport coupled with a Finite Element Method (FEM) for electric potential. Key accomplishments include: • Verification & Validation: The 3-D solver was rigorously verified against 1-D analytical solutions, demonstrating high numerical accuracy in predicting space-charge-induced field deviations. • Field Distortion Analysis: 3D simulations revealed that space charge effects introduce significant non-uniformities in the electric field. Critically, the research identified that background LAr flow velocities, when comparable to ion drift velocities, markedly exacerbate these distortions. • Technology Transfer: The resulting source code and comprehensive user manuals were successfully transferred to collaborators at Fermilab, providing a portable computational tool for the broader scientific community. Challenges and Future Directions While the space-charge solver achieved all performance metrics, the integrated fluid dynamics modeling encountered convergence challenges stemming from the extreme 200-fold disparity in length scales between the detector's 37 mm inlet pipes and the 8-meter global domain. To address this, the project has identified a clear technical pivot toward Hierarchical Geometric Adaptive Mesh Refinement (HG-AMR). By implementing an h-type refinement strategy with hanging nodes, future iterations of this solver will be capable of resolving localized high-gradient inlet flows without the prohibitive computational costs of regular grids. This advancement, combined with data-driven uncertainty quantification based on MicroBooNE-style calibration, will enable the precise modeling of detector responses in large-scale cryogenic environments where direct measurement remains difficult. Impact The computational tools developed under this award provide a foundation for enhancing the energy resolution and spatial reconstruction of noble liquid detectors. By bridging the gap between theoretical fluid dynamics and experimental field calibration, this work supports the DOE’s mission to advance the frontiers of neutrino physics and dark matter detection.

42 ENGINEERING↗

New Approach Methodology for Assessing Inhalation Risks of a Contact Respiratory Cytotoxicant: Computational Fluid Dynamics-Based Aerosol Dosimetry Modeling for Cross-Species and In Vitro Comparisons

Regulatory agencies are considering alternative approaches to assessing inhalation toxicity that utilizes in vitro studies with human cells and in silico modeling in lieu of additional animal studies. In support of this goal, computational fluid-particle dynamics models were developed to estimate site-specific deposition of inhaled aerosols containing the fungicide, chlorothalonil, in the rat and human for comparisons to prior rat inhalation studies and new human in vitro studies. Under bioassay conditions, the deposition was predicted to be greatest at the front of the rat nose followed by the anterior transitional epithelium and larynx corresponding to regions most sensitive to local contact irritation and cytotoxicity. For humans, simulations of aerosol deposition covering potential occupational or residential exposures (1–50 µm diameter) were conducted using nasal and oral breathing. Aerosols in the 1–5 µm range readily penetrated the deep region of the human lung following both oral and nasal breathing. Under actual use conditions (aerosol formulations >10 µm), the majority of deposited doses were in the upper conducting airways. Beyond the nose or mouth, the greatest deposition in the pharynx, larynx, trachea, and bronchi was predicted for aerosols in the 10–20 µm size range. Only small amounts of aerosols >20 µm penetrated past the pharyngeal region. Using the ICRP clearance model, local retained tissue dose metrics including maximal concentrations and areas under the curve were calculated for each airway region following repeated occupational exposures. These results are directly comparable with benchmark doses from in vitro toxicity studies in human cells leading to estimated human equivalent concentrations that reduce the reliance on animals for risk assessments.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

Numerical Optimization of Spray-Guided Spark Assistance for Cold Idle Operation in a Heavy-Duty Gasoline Compression Ignition Engine

This article describes the results of a response surface model (RSM)-based numerical optimization campaign for spray-guided spark assistance at cold operations in a heavy-duty gasoline compression ignition (GCI) engine. On the basis of an earlier work on spark-assisted GCI cold combustion, a space-filling design of experiments (DoE) method was first undertaken to investigate a multitude of hardware design variables and engine operating parameters. The main design variables included the number of injector nozzles, fuel split quantities and injection timings, and spark timing. The objective variables were engine combustion efficiency (ŋ c ), maximum pressure rise rate (MPRR), and engine-out nitrogen oxide (NO x ) emissions. A total of 150 design candidates were automatically generated using the Sobol sequence method provided by the commercial software package, CAESES. Then, closed-cycle computational fluid dynamic (CFD) spark-assisted GCI simulations under cold idling operations were performed. The outcomes from the CFD-DoE design campaign were utilized to construct high-fidelity RSMs that allowed for further design optimization of the spark plug- and fuel injector-related design variables, along with fuel injection strategy parameters. A merit function with respect to objective variables was formulated with an appropriate weight assignment on each objective variable. Finally, the best design candidate was identified from the RSM-based optimization process and further validated in the CFD analysis. The best design candidate showed the potential to significantly improve combustion efficiency (ŋ c > 90%) over the baseline at cold idle while satisfying MPRR and NOx emissions constraints (MPRR < 5 bar/CAD and NO x < 4.5 g/kWh).

33 ADVANCED PROPULSION SYSTEMS↗

Applying Physics-Informed Neural Networks to Solve Navier–Stokes Equations for Laminar Flow around a Particle

In recent years, Physics-Informed Neural Networks (PINNs) have drawn great interest among researchers as a tool to solve computational physics problems. Unlike conventional neural networks, which are black-box models that “blindly” establish a correlation between input and output variables using a large quantity of labeled data, PINNs directly embed physical laws (primarily partial differential equations) within the loss function of neural networks. By minimizing the loss function, this approach allows the output variables to automatically satisfy physical equations without the need for labeled data. The Navier–Stokes equation is one of the most classic governing equations in thermal fluid engineering. This study constructs a PINN to solve the Navier–Stokes equations for a 2D incompressible laminar flow problem. Flows passing around a 2D circular particle are chosen as the benchmark case, and an elliptical particle is also examined to enrich the research. The velocity and pressure fields are predicted by the PINNs, and the results are compared with those derived from Computational Fluid Dynamics (CFD). Additionally, the particle drag force coefficient is calculated to quantify the discrepancy in the results of the PINNs as compared to CFD outcomes. The drag coefficient maintained an error within 10% across all test scenarios.

Hu, Beichao (ORCID:0009000163215151)↗

Application of GOTHIC to Groundwater Transport Analysis - 20152

Migration of pollutants and hazardous wastes, potentially containing radioactive isotopes, via groundwater transport is a concern at most waste cleanup sites. Predictive analysis can be used to evaluate mitigating actions intended to minimize impact on the environment and public exposure. GOTHIC is a multipurpose thermal hydraulics code that is used extensively in the nuclear industry for design, licensing and operation evaluations. It combines the capabilities of typical one-dimensional system codes and the essential features of Computational Fluid Dynamics (CFD) codes for three-dimensional analysis. There are other codes that are specifically developed for groundwater transport analysis and the results presented here are consistent with prior analyses. However, GOTHIC has some unique features that offer advantages for applications related to nuclear waste. Most importantly, it has been developed and maintained under a Quality Assurance program in compliance with the requirements of 10CFR50 Appendix B [2] and applicable portions of ASME NQA-1 [3] since 1995. Available GOTHIC capabilities that make the code especially useful for groundwater transport of nuclear materials include: - Tracking of any number of tracer elements for contaminants and other species of interest; - Radioactive decay and progeny of tracer elements; - Adsorption/desorption of tracer elements; - Tracking of any number of dissolved gases; - Release and absorption for dissolved gases; - Vapor phase tracking; - Non-Newtonian fluid modeling. The general porous body modeling approach makes GOTHIC well suited to groundwater transport analysis. The multi-region modeling approach used by GOTHIC simplifies model construction for regions of varying hydrologic characteristics and focuses the computational effort on regions of particular interest while simultaneously capturing the macroscopic response and any feedback effects across the larger domain. The applicability of GOTHIC to groundwater transport applications is demonstrated by comparing code results with available analytic or semi-analytic solutions for groundwater behavior. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Midfidelity model verification for a point-absorbing wave energy converter with linear power take-off

In the preliminary design stage of a wave energy converter (WEC), researchers need fast and reliable simulation tools. High-fidelity numerical models are usually employed to study the wave-structure interaction, but the computational cost is demanding. As an alternative, midfidelity models can provide simulations in the order of real time. In this study, we operate Uppsala University’s WEC in a relatively mild sea state and model it using WEC-Sim. The model is verified based on OpenFOAM simulations. To analyze the ability of the midfidelity model to capture WEC dynamics, we investigate the system separately with 1, 2, and 3 degrees of freedom. We examine the contribution of viscous phenomena, and study both linear and weakly nonlinear solutions provided by WEC-Sim. Our results indicate that the viscous effects can be neglected in heave and surge motion, but not for pitch. We also find that the weakly nonlinear WEC-Sim solution successfully agrees with the computational fluid dynamics, whereas the linear solution could suggest misleading results.

16 TIDAL AND WAVE POWER↗

Enhancing $\phi$-sensitivity of ignition delay times through dilution of fuel-air mixture

The high $\phi$-sensitivity (η) of ignition delay time (τ IDT ) is one of the desirable fuel properties for the high-load extension of advanced compression ignition engine. Recent studies revealed the effectiveness of a high dilution rate (x D ) for enhancing η at the engine-relevant conditions. This study aims to quantify the effect of dilution on the η of isooctane using a combined experiment-simulation approach. The ignition delay of the isooctane/air mixture was measured with an Advanced Fuel Ignition Delay Analyzer (AFIDA) over the temperature range of 623 - 923 K at 10 bar pressure with global $\phi$ = 0.3 - 0.6, with and without 28.6% of additional N 2 dilution. For precise evaluation of experimental η, the facility effect of the AFIDA experiment was characterized with three-dimensional computational fluid dynamics (3-D CFD) simulation. The temperature in the combustion chamber from 3-D CFD indicated a substantial temporal dependency, varying up to ~52 K by charge-cooling of fuel injection and heat transfer from the wall. We introduced the dimensionless number θ(t) for characterizing the temporal profile of chamber temperature. Consideration of the facility effect using θ(t) resulted in better agreement between the experimental ..eta.. and zero-dimensional (0-D) kinetics simulation. The refined η were then further utilized to quantify the effectiveness of dilution to η The extent of η enhancement with dilution strategy was maximized at the low-temperature chemistry regime, increasing η by 77% with a 28.6% dilution rate. Further analysis on the dilution effect was carried out using 0-D kinetics simulation, revealing the critical dimensionless numbers relevant to the effectiveness of dilution to η enhancement. Here, this study is the first experiment-simulation combined research to quantify the effect of dilution on η, facilitating the kinetics model refinement for better reproduction of $\phi$-sensitivity.

33 ADVANCED PROPULSION SYSTEMS↗

Numerical Simulation of a Natural Convection–Driven Air-Cooled Reactor Cavity Cooling System Experiment

Ensuring the efficient removal of decay heat from the reactor vessel is essential for the safety of advanced reactor technologies. Several Generation-IV concepts incorporate variations in the reactor vessel cooling systems to achieve this objective. High-temperature gas-cooled reactors utilize a reactor cavity cooling system (RCCS), a passive ex-vessel system designed to operate without active components or external power during accident conditions. The RCCS removes decay heat primarily through radiative and convective heat transfer mechanisms. Here, this study presents a comprehensive validation of a computational fluid dynamics Reynolds-averaged Navier-Stokes model for the University of Wisconsin-Madison air-cooled RCCS facility. Validation was conducted for both high- and low-power natural convection cases under a uniform heating profile. Near-wall resolution was found to be critical for accurately modeling natural convection in the RCCS; employing an all-𝑦 + wall treatment resulted in wall temperature discrepancies exceeding 50 °⁢𝐶 compared to a wall-resolved mesh. Thermal-hydraulic behaviors under natural and forced convection conditions were compared within the heated cavity and RCCS. A turbulence model sensitivity analysis indicated that low-Reynolds number k-ɛ, k-ω shear stress transport (SST), and Reynolds stress transport models produce similar wall temperature predictions. A buoyancy modeling sensitivity study revealed that the Boussinesq approximation significantly underpredicted thermal-hydraulic behavior in the RCCS. Based on these findings, modeling recommendations are provided. The validated data set along with identified sensitivities refine the modeling of natural convection in the RCCS. The information produced by this study supports RCCS design, optimization, and safety evaluations, enabling the calibration and verification of reduced-order thermal-hydraulic models.

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗

Outflow Boundary Conditions for Turbine-Integrated Rotating Detonation Combustors

This study examines outflow boundary conditions (BCs) in computational fluid dynamics (CFD) simulations of a transition duct with and without guide vanes that converts supersonic flow exiting a rotating detonation combustor (RDC) to subsonic flow to drive a turbine. Since the flow exiting the transition duct has swirling shock waves with significant spatial and temporal variations in pressure, temperature, and Mach number, imposing proper BCs poses a challenge. To ensure all swirling shock waves exit the transition duct without creating non-physical reflected waves at its outlet, this study examined three outflow BCs: (1) the average pressure imposed at the duct’s outlet, (2) a nonreflecting BC (NRBC) with a specified average pressure imposed at the duct’s outlet, (3) the average pressure imposed at the outlet of an extension duct made up of a buffer layer and a sponge layer. This study is based on the three-dimensional, unsteady density-weighted-ensemble-averaged continuity, Navier–Stokes, and energy equations for a thermally perfect gas closed by the realizable k–ε model and “enhanced” wall functions. The results obtained show that imposing an average pressure at the transition duct’s outlet produces spurious waves that degrade the physical meaningfulness of the solution. When the NRBC was applied, swirling shock waves exited the duct’s outlet without creating spurious waves. However, its usage requires the gas to be thermally, as well as calorically, perfect, which this study shows could be a concern. By imposing the average pressure at the outlet of an extension duct, the gas does not need to be calorically perfect. The results obtained show the effects of the sponge layer’s length and coarsening ratio on damping nonuniformities in non-physical reflected waves to ensure the flow exiting the transition duct’s outlet can do so as if there are no boundaries present and has the desired average pressure—even though the BC is applied at the extension duct’s outlet.

gas turbines↗

Aeroelastic Analysis Using Deforming Cartesian Grids

Ongoing work in air-vehicle design illustrates the potential of advanced concepts to provide significant improvements in efficiency; but with their incorporation of lightweight flexible structures, such configurations may require active control systems to ensure reliability and safety. However, many contemporary analysis methods are inefficient for aeroelastic analysis and design of such configurations. This paper describes the development of a new approach that automates the geometry setup, mesh generation, and assembly of fluid–structural coupling interfaces to enable efficient aeroelastic and aeroservoelastic analysis of advanced concepts. The core elements for this approach are a cut-cell Cartesian grid-based computational fluid dynamics solver, a nonlinear beam element structural model, a conservative fluid–structural interface treatment, and the formulation and implementation of a new deforming grid capability within the cut-cell Cartesian grid solver. In this paper, emphasis is on this latter component with detailed description given of the mesh motion strategy, evaluation of fluxes and structural loads at the surface, and computation of geometrical properties such as cell volume, directed face areas, centroids, and motion-induced fluxes for deforming Cartesian grids required to advance the flow states. Aeroelastic simulations exercising the capability show favorable agreement with data and predictions in the literature for subsonic and supersonic applications.

97 MATHEMATICS AND COMPUTING↗

Aerodynamic effects on outer ash deposition rates in second generation atmospheric pressure oxy-coal combustion systems

Recent measurements in scenarios representative of second generation atmospheric pressure oxy-coal combustion systems have shown a significant increase in ash deposition rates in comparison to combustion in air. However, the causative mechanisms behind this increase have not been well understood. To fill this void, well-characterized experiments including fuel and deposit particle size distributions (PSDs) were coupled with highly resolved numerical simulations to isolate the aerodynamic effects impacting the deposition process such that mechanisms could be hypothesized. Three combustion scenarios (AIR, OXY27, OXY70) spanning a factor of three variation in flue gas volumetric flow rates were simulated and the deposition characteristics (impaction rates, deposit PSD, temperature, residence times, capture rates) tracked/predicted using a customized deposition module. The measured deposit PSD was significantly different from the PSD of the parent fuel indicating significant physio-chemical transformations (coalescence and particle growth in particular) at play. The use of simplistic modeling approaches (swelling parameter variations) to model particle growth led to inaccurate deposit ash PSD and rate predictions. A more satisfactory agreement between the measurements and simulations was obtained when the functional form of the parent fuel PSD (spread parameter) was modified to conform closely to the deposit PSD while still ensuring the fidelity of temperature and velocity predictions. Based on the measured ash compositions, identical capture criteria were employed across all three scenarios. Here this study further supports the theory that the ash deposition rates in these systems are dominated by aerodynamic effects with the ash PSD playing a dominant role.

42 ENGINEERING↗

Measurements and Prediction of Ash Deposition in a Cyclone-Fired Boiler Operating under Variable Load Conditions

Measurements of ash deposition rates were made between the secondary superheater and reheater sections of a 450 MW cyclone-fired lignite boiler as the operational load varied from 33 to 100%. Significant reductions in deposition rates with a decrease in operational load were observed. To uncover the causative mechanisms behind these observations, operational data from the power plant were used to carry out computational fluid dynamic (CFD) simulations of the boiler. After ascertaining that the gas temperatures and velocities at various sections within the boiler were being represented adequately, decoupled simulations of the ash deposition process on the deposit probe were carried out using a finely resolved boundary layer mesh. Fly ash particle size distribution (PSD) and its concentration for the decoupled calculations were determined from stand-alone cyclone barrel simulations. The ash partitioning (mass %) between the fly ash and slag was found to be ~50:50, which was in line with previous field observations, and it did not vary significantly across different cyclone loads. The predicted PSD of the deposit ash was concentrated in the size range 10–30 microns, which was in agreement with cross-sectional images of the deposit obtained from the measurements. At lower loads, sharp variations in the deposition rates were predicted in the gas temperature range 950–1150 K. The particle kinetic energy—particle viscosity-based capture methodology utilized in this study in conjunction with appropriate ash compositions, ash viscosity models and gas temperature estimates can help estimate slagging propensities at different loads reasonably well in these systems.

Krishnamoorthy, Gautham (ORCID:0000000255205092)↗

Optimization of direct air capture processes using reactive transport models of adsorption-desorption cycles

In this study, we develop and implement a reactive transport model in COMSOL Multiphysics® to address the challenges of direct air carbon capture. The model is validated against experimental data and used to simulate the cyclic steady state of the adsorption-desorption process. The optimization of this model is achieved through advanced trust-region methods integrated with Gaussian Processes. Key decision variables, including adsorption and desorption times, desorption temperature and pressure, input velocity, bed porosity, column length, and radius were optimized to minimize the capture cost. After optimization, a sensitivity analysis revealed the complex interplay between the decision variables and their effect on the specific energy and cost of removing the CO 2 . We optimized the capture cost while taking into account the trade-off between energy consumption and productivity. The resulting minimum capture cost was determined to be 265.2 $/t-CO 2 , which aligns with expected values reported in the literature. Numerical results suggest the effectiveness of the optimization strategies applied, and underscore the importance of simultaneous decision variable selection in improving the performance in direct air capture processes. We also extend the modeling approach to a 2D axisymmetric model to better visualize CO₂ uptake and temperature profiles, revealing significant radial gradients during the regeneration step. As a main drawback, this enhanced model comes with a computational cost approximately 40 times higher than that of the 1D model.

Adsorption-desorption process↗

Wind Farm Simulation and Layout Optimization in Complex Terrain: Preprint

This work reports on incorporating complex terrain into wind farm simulations for the purpose of layout optimization. Adding complex terrain boundary conditions to NREL's medium fidelity computational fluid dynamics model, WindSE, produces significant separation, flow curvature, and speedup effects that would otherwise be difficult to capture with lower-fidelity models or a flat-terrain assumption. These flow features, in turn, can significantly impact the optimal turbine array layout. We demonstrate the impact of complex terrain on flow in both an idealized and real-world setting, and discuss modifications to the code that enable gradient-based optimization using terrain-aware adjoint gradients. Through several optimization case studies, we show that the layout optimization process takes advantage of speedup effects on terrain high points, and leverages flow curvature effects that modify wake trajectories. This yields substantial power improvements over gridded layouts, and hints at future research directions in simulation and optimization for wake trajectories in complex terrain.

17 WIND ENERGY↗

High Fidelity Digital Twins for BWRX-300 Critical Systems

This project developed and demonstrated digital-twin technology for advanced nuclear systems under the ARPA-E GEMINA program, with a focus on the BWRX-300 small modular reactor. The primary objective was to reduce operation and maintenance (O&M) costs through predictive health monitoring and model-based fault detection. The project combined MIT’s high-fidelity physics models and machine-learning and digital-twin algorithms, and GE Hitachi’s digital-twin algorithms and operational expertise to build physics-based digital twins capable of real-time system monitoring and maintenance scheduling.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Impact of grassland fire dynamics on particulate emission factors

Understanding particulate emission factors in grassland fires is critical for improving air quality assessments and refining emissions inventories. This study explores the dynamic and heterogeneous nature of fire processes and their influence on particulate emissions. Traditional emission factor inventories often rely on static values, overlooking the spatially and temporally variable dynamics of fire behavior. Through field experiments conducted at Konza Prairie Biological Station measuring emissions with uncrewed aerial vehicles, and computational modeling using HIGRAD/FIRETEC, this research highlights the dependency of emission production on localized fire dynamics, including ignition patterns, fuel properties, and atmospheric conditions. The results demonstrate a need for fire dynamic considerations to accurately capture emissions variability.

09 BIOMASS FUELS↗

Simulations for Planning of Liquid Hydrogen Spill Test

In order to better understand the complex pooling and vaporization of a liquid hydrogen spill, Sandia National Laboratories is conducting a highly instrumented, controlled experiment inside their Shock Tube Facility. Simulations were run before the experiment to help with the planning of experimental conditions, including sensor placement and cross wind velocity. This paper describes the modeling used in this planning process and its main conclusions. Sierra Suite’s Fuego, an in-house computational fluid dynamics code, was used to simulate a RANS model of a liquid hydrogen spill with five crosswind velocities: 0.45, 0.89, 1.34, 1.79, and 2.24 m/s. Two pool sizes were considered: a diameter of 0.85 m and a diameter of 1.7. A grid resolution study was completed on the smaller pool size with a 1.34 m/s crosswind. A comparison of the length and height of the plume of flammable hydrogen vaporizing from the pool shows that the plume becomes longer and remains closer to the ground with increasing wind speed. The plume reaches the top of the facility only in the 0.45 m/s case. From these results, we concluded that it will be best for the spacing and location of the concentration sensors to be reconfigured for each wind speed during the experiment.

08 HYDROGEN↗

A non-intrusive framework using acoustic signals and deep learning for boiling diagnostics in visual-limited environments

Accurate monitoring of boiling heat transfer is critical for safeguarding high-power systems operating in environments where conventional optical diagnostics are hindered by radiation fields or restricted visual accessibility. This study presents a non-intrusive framework that integrates hydroacoustic sensing with deep learning to infer near-wall boiling characteristics and enable predictive thermal assessment without visual access. In a prototypical subcooled flow-boiling facility representative of the Isotope Production Facility (IPF) at Los Alamos, hydrophones capture boiling-induced acoustic emissions that are transformed into background-removed Short-Time Fourier Transform (STFT) spectrograms. A convolutional neural network (CNN) then regresses heat flux, wall superheat, and key bubble parameters directly from these spectrograms. The CNN achieved predictive accuracy under nominal conditions and demonstrated robustness and generalization under acoustic noise for Signal-to-Noise Ratios (SNRs) down to approximately 0 dB. When integrated into an ANSYS CFX wall-boiling model, the acoustically inferred parameters reproduced boiling curve and critical heat flux (CHF) values consistent with image-based benchmarks. Furthermore, the model retained reliable performance under moderate variations in bulk temperature, flow rate, and hydrophone placement, confirming its generalizability across practical boundary conditions. These results demonstrate the feasibility of hydroacoustic-based deep learning as a viable path toward real-time, radiation-tolerant boiling diagnostics and predictive thermal safety assessment in inaccessible systems such as the IPF.

42 ENGINEERING↗