Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CAPACITY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 883 records · Page 49

Spur, helical, and spiral bevel transmission life modeling

A computer program, TLIFE, which estimates the life, dynamic capacity, and reliability of aircraft transmissions, is presented. The program enables comparisons of transmission service life at the design stage for optimization. A variety of transmissions may be analyzed including: spur, helical, and spiral bevel reductions as well as series combinations of these reductions. The basic spur and helical reductions include: single mesh, compound, and parallel path plus revert star and planetary gear trains. A variety of straddle and overhung bearing configurations on the gear shafts are possible as is the use of a ring gear for the output. The spiral bevel reductions include single and dual input drives with arbitrary shaft angles. The program is written in FORTRAN 77 and has been executed both in the personal computer DOS environment and on UNIX workstations. The analysis may be performed in either the SI metric or the English inch system of units. The reliability and life analysis is based on the two-parameter Weibull distribution lives of the component gears and bearings. The program output file describes the overall transmission and each constituent transmission, its components, and their locations, capacities, and loads. Primary output is the dynamic capacity and 90-percent reliability and mean lives of the unit transmissions and the overall system which can be used to estimate service overhaul frequency requirements. Two examples are presented to illustrate the information available for single element and series transmissions.

Savage, Michael↗

Dynamic force response of spherical hydrostatic journal bearing for cryogenic applications

Hydrostatic Journal Bearings (HJB's) are reliable and resilient fluid film rotor support elements ideal to replace roller bearings in cryogenic turbomachinery. HJB' will be used for primary space-power applications due to their long lifetime, low friction and wear, large load capacity, large direct stiffness, and damping force coefficients. An analysis for the performance characteristics of turbulent flow, orifice compensated, spherical hydrostatic journal bearings (HJB's) is presented. Spherical bearings allow tolerance for shaft misalignment without force performance degradation and have also the ability to support axial loads. The spherical HJB combines these advantages to provide a bearing design which could be used efficiently on high performance turbomachinery. The motion of a barotropic liquid on the thin film bearing lands is described by bulk-flow mass and momentum equations. These equations are solved numerically using an efficient CFD method. Numerical predictions of load capacity and force coefficients for a 6 recess, spherical HJB in a LO2 environment are presented. Fluid film axial forces and force coefficients of a magnitude about 20% of the radial load capacity are predicted for the case analyzed. Fluid inertia effects, advective and centrifugal, are found to affect greatly the static and dynamic force performance of the bearing studied.

Sanandres, Luis↗

Radiometric resolution enhancement by lossy compression as compared to truncation followed by lossless compression

Recent advances in imaging technology make it possible to obtain imagery data of the Earth at high spatial, spectral and radiometric resolutions from Earth orbiting satellites. The rate at which the data is collected from these satellites can far exceed the channel capacity of the data downlink. Reducing the data rate to within the channel capacity can often require painful trade-offs in which certain scientific returns are sacrificed for the sake of others. In this paper we model the radiometric version of this form of lossy compression by dropping a specified number of least significant bits from each data pixel and compressing the remaining bits using an appropriate lossless compression technique. We call this approach 'truncation followed by lossless compression' or TLLC. We compare the TLLC approach with applying a lossy compression technique to the data for reducing the data rate to the channel capacity, and demonstrate that each of three different lossy compression techniques (JPEG/DCT, VQ and Model-Based VQ) give a better effective radiometric resolution than TLLC for a given channel rate.

Tilton, James C.↗

Effect of KOH concentration and anions on the performance of Ni-H2 battery positive plate

The capacity and voltage behavior of electrochemically impregnated sintered nickel positive plates was examined by galavanostatic charging; and discharging in a flooded electrolyte cell. Three different concentrations of KOH (40 percent, 31 percent, and 26 percent) and 31 percent KOH containing dissolved nitrate, sulfate or silicate were investigated. The end of charge voltage at C/10 charge and at 10 C showed the following order: 40 percent KOH is greater than 31 percent KOH alone and in the presence of the anions greater than 26 percent KOE. The middischarge voltage at C/2 discharge was higher in 26 percent KOH, almost the same for 31 percent KOH with and without the added contaminants and much lower for 40 percent KOH. The plate capacity was marginally affected by cycling in all cases except for 40 percent KOH where the capacity declined after 1000 cycles at 80 percent DOD. At the end of cycling the plate tested in the presence of sulfate and silicate experienced measurable weight loss as a result of active material extrusion. Cyclic voltammetry of miniature electrodes in 31 percent KOH showed that the second oxidation peak that corresponds to the formation of a different phase of oxidized Ni has a lower peak current at -5 C compared to 25 C and oxygen evolution occurs a higher potential at -5 C. The reduction peak (discharge reaction) is more polarized at 25 C compared to -5 C. The presence of silicate alters the potentials only marginally. The implications of these results in plate treatment and low temperature operation are discussed.

Vaidyanathan, H.↗

Lung volumes during sustained microgravity on Spacelab SLS-1

Gravity is known to influence the mechanical behavior of the lung and chest wall. However, the effect of sustained microgravity (microgravity) on lung volumes has not been reported. Pulmonary function tests were performed by four subjects before, during, and after 9 days of microgravity exposure. Ground measurements were made in standing and supine postures. Tests were performed using a bag-in-box-and-flowmeter system and a respiratory mass spectrometer. Measurements included functional residual capacity (FRC), expiratory reserve volume (ERV), residual volume (RV), inspiratory and expiratory vital capacities (IVC and EVC), and tidal volume (V9sub T)). Total lung capacity (TLC) was derived from the measured EVC and RV values. With preflight standing values as a comparison, FRC was significantly reduced by 15% (approximately 500 ml) in microgravity and 32% in the supine posture. ERV was reduced by 10 - 20% in microgravity and decreased by 64% in the supine posture. RV was significantly reduced by 18% (310 ml) in microgravity but did not significantly change in the supine posture compared with standing. IVC and EVC were slightly reduced during the first 24 h of microgravity but returned to 1-G standing values within 72 h of microgravity exposure. IVC and EVC in the supine posture were significantly reduced by 12% compared with standing. During microgravity, V(sub T) decreased by 15% (approximately 90 ml), but supine V(sub T) was unchanged compared with preflight standing values. TLC decreased by approximately 8% during microgravity and in the supine posture compared with preflight standing. The reductions in FRC, ERV, and RV during microgravity are probably due to the cranial shift of the diaphragm, an increase in intrathoracic blood volume, and more uniform alveolar expansion.

Elliott, Ann R.↗

Exercise Responses after Inactivity

The exercise response after bed rest inactivity is a reduction in the physical work capacity and is manifested by significant decreases in oxygen uptake. The magnitude of decrease in maximal oxygen intake V(dot)O2max is related to the duration of confinement and the pre-bed-rest level of aerobic fitness; these relationships are relatively independent of age and gender. The reduced exercise performance and V(dot)O2max following bed rest are associated with various physiological adaptations including reductions in blood volume, submaximal and maximal stroke volume, maximal cardiac output, sceletal muscle tone and strength, and aerobic enzyme capacities, as well as increases in venous compliance and submaximal and maximal heart rate. This reduction in physiological capacity can be partially restored by specific countermeasures that provide regular muscular activity or orhtostatic stress or both during the bed rest exposure. The understanding of these physiological and physical responses to exercise following bed rest inactivity has important implications for the solution to safety and health problems that arise in clinical medicine, aerospace medicine, sedentary living, and aging.

Convertino, Victor A.↗

DS-CDMA satellite diversity reception for personal satellite communication: Downlink performance analysis

The downlink of a satellite-mobile personal communication system employing power-controlled Direct Sequence Code Division Multiple Access (DS-CDMA) and exploiting satellite-diversity is analyzed and its performance compared with a more traditional communication system utilizing single satellite reception. The analytical model developed has been thoroughly validated by means of extensive Monte Carlo computer simulations. It is shown how the capacity gain provided by diversity reception shrinks considerably in the presence of increasing traffic or in the case of light shadowing conditions. Moreover, the quantitative results tend to indicate that to combat system capacity reduction due to intra-system interference, no more than two satellites shall be active over the same region. To achieve higher system capacity, differently from terrestrial cellular systems, Multi-User Detection (MUD) techniques are likely to be required in the mobile user terminal, thus considerably increasing its complexity.

DeGaudenzi, Riccardo↗

Wake Vortex Encounter Research

The National Aeronautics and Space Administration (NASA) is conducting research to improve airport capacity by reducing the separation distance between aircraft. The limiting factor in reducing separation distances and improving airport capacity is the wake vortex hazard. The ability to accurately model wake vortices and predict the outcome of a vortex encounter is critical in developing a system to safely improve airport capacity. This is the focus of the wake vortex research being done at NASA Langley Research Center (LaRC). This paper will concentrate on two topics. The first topic is the control system developed for the Boeing 737 freeflight model in support of vortex encounter tests to be conducted in the 30- by 60- foot tunnel at NASA Langley Research Center later this year. The second topic discussed is the limited degree of freedom (DOF) trajectory generation study that is being conducted to determine the relative severity of a multitude of paths through a wake vortex.

Wilson, Jeffrey M.↗

Effect of KOH Concentration and Anions on the Performance of a Ni-H2 Battery Positive Plate

The capacity and voltage behavior of electrochemically impregnated sintered nickel positive plates was examined by galvanostatic charging and discharging in a flooded electrolyte cell. Three different concentrations of potassium hydroxide (KOH) (40, 31, and 26 percent) and 31 percent KOH containing dissolved nitrate, sulfate, or silicate were investigated. The end-of-charge voltage at C/10 charge and at 10 degrees C showed the following order: 40 percent KOH greater than 31 percent KOH alone and in the presence of the anions greater than 26 percent KOH. The mid discharge voltage at C/2 discharge was higher in 26 percent KOH, almost the same for 31 percent KOH with and without added contaminants, and much lower for 40 percent KOH. The plate capacity was marginally affected by cycling in all cases except for 40 percent KOH, where the capacity declined after 1,000 cycles at 80 percent depth of discharge (DOD). At the end of cycling, all the plates tested experienced a weight loss, except in the case of 31 percent KOH, as a result of active material extrusion. Cyclic voltammetry of miniature electrodes in 31 percent KOH showed that the cathodic peak potentials are less polarized in the presence and absence of silicate at -5 degrees C compared to 25 degrees C indicating a slightly higher voltage during discharge in a Ni-H2 battery. Futhermore, the features of the current-potential profile were practically unchanged in the presence of silicate.

Vaidyanathan, Hari↗

Regulation of Methane Oxidation in a Freshwater Wetland by Water Table Changes and Anoxia

The effects of water table fluctuations and anoxia on methane emission and methane oxidation were studied in a freshwater marsh. Seasonal aerobic methane oxidation rates varied between 15% and 76% of the potential diffusive methane flux (diffusive flux in the absence of aerobic oxidation). On an annual basis, approximately 43% of the methane diffusing into the oxic zone was oxidized before reaching the atmosphere. The highest methane oxidation was observed when the water table was below the peat surface. This was confirmed in laboratory experiments where short-term decreases in water table levels increased methane oxidation but also net methane emission. Although methane emission was generally not observed during the winter, stems of soft rush (Juncus effusus) emitted methane when the marsh was ice covered. Indigenous methanotrophic bacteria from the wetiand studied were relatively anoxia tolerant. Surface peat incubated under anoxic conditions maintained 30% of the initial methane oxidation capacity after 32 days of anoxia. Methanotrophs from anoxic peat initiated aerobic methane oxidation relatively quickly after oxygen addition (1-7 hours). These results were supported by culture experiments with the methanotroph Methylosinus trichosporium OB3b. This organism maintained a greater capacity for aerobic methane oxidation when starved under anoxic compared to oxic conditions. Anoxic incubation of M. trichosporium OB3b in the presence of sulfide (2 mM) and a low redox potential (-110 mV) did not decrease the capacity for methane oxidation relative to anoxic cultures incubated without sulfide. The results suggest that aerobic methane oxidation was a major regulator of seasonal methane emission front the investigated wetland. The observed water table fluctuations affected net methane oxidation presumably due to associated changes in oxygen gradients. However, changes from oxic to anoxic conditions in situ had relatively little effect on survival of the methanotrophic bacteria and thus on methane oxidation potential per se.

Roslev, Peter↗

Performance Comparison Between NiH2 Dry Sinter and Slurry Electrode Cells

The electrical and thermal performance of dry sinter and slurry process electrode cells manufactured for the Hubble Space Telescope (HST) batteries have been characterized for a matrix of operating conditions over the temperature range from 14 to 86 F at various charge control levels. The dry sinter process electrode cells tested are similar to the onboard HST NiH2 cells. The slurry process electrode cells were developed to be less susceptible to electrode expansion and impedance changes with life. Both cell types were impregnated by the aqueous electrochemical process. Test conditions included standard capacity tests and electrical cycling using 96-minute cycling regimens incorporating gr depth-of-discharge (DOD) cycles. The dry sinter process electrodes have higher operating capacities to 1.20V/cell, but both electrode types have similar heat dissipation for the conditions tested. The results of the testing included cyclic heat generation during a typical 96-minute cycle, operating capacity data vs. cutoff voltage to generate a temperature-compensated voltage curve, and voltage characteristics suitable to develop a voltage prediction model. Analysis of data shows differences in the discharge voltage plateaus operating conditions evaluated. This is the basis for recommended changes in the battery charge control.

Armantrout, J. D.↗

Damage Tolerance of Sandwich Plates with Debonded Face Sheets

Axial compression tests were performed on debonded sandwich composites made of graphite/epoxy face-sheets and aramid fiber honeycomb core. The sandwich beams were manufactured using a vacuum baccrin2 process. The face-sheet and the sandwich beam were co-cured. Delamination between one of the face sheets and the core was introduced by using a Teflon layer during the curing process. Axial compression tests were performed to determine the ultimate load carrying capacity of the debonded beams. Flatwise tension tests and Double Cantilever Beam tests were performed to determine. respectively, the strength and fracture toughness of the face-sheet/core interface. From the test results semi-empirical formulas were derived for the fracture toughness and ultimate compressive load carrying capacity in terms of the core density. core thickness. face-sheet thickness and debond length. Four different failure modes and their relation to the structural properties were identified. Linear buckling analysis was found to be inadequate in predicting the compressive load carrying capacity of the debonded sandwich composites.

Avery, John L., III↗

Consequences of Slot Transactions on Airport Congestion and Environmental Protection

Recent trends in the liberalization of market access by many commercial airlines have opened the skies to virtually unlimited flights between many countries. However, this liberalization is stultified by the lack of airport capacity to accommodate the many flights that are generated by demand for capacity. Accordingly, the allocation of slots for open skies airlines remain dependent on the expansion and effective management of airport capacity. This article examines the ramifications of slot allocation on traffic peaking at airports and environmental concerns, which may emerge with this activity.

Abeyratne, Ruwantissa I.R.↗

Storage Characteristics of Lithium Ion Cells

Lithium ion cells are being developed under the NASA/Air Force Consortium for the upcoming aerospace missions. First among these missions are the Mars 2001 Lander and Mars 2003 Lander and Rover missions. Apart from the usual needs of high specific energy, energy density and long cycle life, a critical performance characteristic for the Mars missions is low temperature performance. The batteries need to perform well at -20 C, with at least 70% of the rated capacity realizable at moderate discharge rates (C/5). Several modifications have been made to the lithium ion chemistry, mainly with respect to the electrolyte, both at JPL' and elsewhere to achieve this. Another key requirement for the battery is its storageability during pre-cruise and cruise periods. For the Mars programs, the cruise period is relatively short, about 12 months, compared to the Outer Planets missions (3-8 years). Yet, the initial results of our storage studies reveal that the cells do sustain noticeable permanent degradation under certain storage conditions, typically of 10% over two months duration at ambient temperatures, attributed to impedance buildup. The build up of the cell impedance or the decay in the cell capacity is affected by various storage parameters, i.e., storage temperature, storage duration, storage mode (open circuit, on buss or cycling at low rates) and state of charge. Our preliminary studies indicate that low storage temperatures and states of charge are preferable. In some cases, we have observed permanent capacity losses of approx. 10% over eight-week storage at 40 C, compared to approx. 0-2% at O C. Also, we are attempting to determine the impact of cell chemistry and design upon the storageability of Li ion cells.

Ratnakumar, B. V.↗

Modeling of Wake-vortex Aircraft Encounters

There are more people passing through the world's airports today than at any other time in history. With this increase in civil transport, airports are becoming capacity limited. In order to increase capacity and thus meet the demands of the flying public, the number of runways and number of flights per runway must be increased. In response to the demand, the National Aeronautics and Space Administration (NASA), in conjunction with the Federal Aviation Administration (FAA), airport operators, and the airline industry are taking steps to increase airport capacity without jeopardizing safety. Increasing the production per runway increases the likelihood that an aircraft will encounter the trailing wake-vortex of another aircraft. The hazard of a wake-vortex encounter is that heavy load aircraft can produce high intensity wake turbulence, through the development of its wing-tip vortices. A smaller aircraft following in the wake of the heavy load aircraft will experience redistribution of its aerodynamic load. This creates a safety hazard for the smaller aircraft. Understanding this load redistribution is of great importance, particularly during landing and take-off. In this research wake-vortex effects on an encountering 10% scale model of the B737-100 aircraft are modeled using both strip theory and vortex-lattice modeling methods. The models are then compared to wind tunnel data that was taken in the 30ft x 60ft wind tunnel at NASA Langley Research Center (LaRC). Comparisons are made to determine if the models will have acceptable accuracy when parts of the geometry are removed, such as the horizontal stabilizer and the vertical tail. A sensitivity analysis was also performed to observe how accurately the models could match the experimental data if there was a 10% error in the circulation strength. It was determined that both models show accurate results when the wing, horizontal stabilizer, and vertical tail were a part of the geometry. When the horizontal stabilizer and vertical tail were removed there were difficulties modeling the sideforce coefficient and pitching moment. With the removal of only the vertical tail unacceptable errors occurred when modeling the sideforce coefficient and yawing moment. Lift could not be modeled with either the full geometry or the reduced geometry attempts.

Smith, Sonya T.↗

The Effect of Journal Roughness and Foil Coatings on the Performance of Heavily Loaded Foil Air Bearings

Foil air bearing load capacity tests were conducted to investigate if a solid lubricant coating applied to the surface of the bearing's top foil can function as a break-in coating. Two foil coating materials, a conventional soft polymer film (polyimide) and a hard ceramic (alumina), were independently evaluated against as-ground and worn (run-in) journals coated with NASA PS304, a high-temperature solid lubricant composite coating. The foil coatings were evaluated at journal rotational speeds of 30,000 rpm and at 25 C. Tests were also performed on a foil bearing with a bare (uncoated) nickel-based superalloy top foil to establish a baseline for comparison. The test results indicate that the presence of a top foil solid lubricant coating is effective at increasing the load capacity performance of the foil bearing. Compared to the uncoated baseline, the addition of the soft polymer coating on the top foil increased the bearing load coefficient by 120% when operating against an as-ground journal surface and 85 percent against a run-in journal surface. The alumina coating increased the load coefficient by 40% against the as-ground journal but did not have any affect when the bearing was operated with the run-in journal. The results suggest that the addition of solid lubricant films provide added lubrication when the air film is marginal indicating that as the load capacity is approached foil air bearings transition from hydrodynamic to mixed and boundary lubrication.

Radil, Kevin C.↗

Normal Gravity Testing of a Microchannel Phase Separator for In Situ Resource Utilization

A microchannel separator, with 2.7 millimeters as the smallest dimension, was tested, and a pore throat structure captured and removed liquid from a gas-liquid stream. The microchannel device was tested over a of gas and liquid flow rates ranging from 0.0005 up to 0. 14 volume fraction of liquid. Four liquids were tested with air. The biggest factor affecting the throughput is the capacity of liquid flow through the pore throat, which is dictated by permeability, liquid viscosity, flow area, pore throat thickness, and pressure difference across the pore throat. Typically, complete separation of gas and liquid fractions was lost when the liquid flow rate reached about 40 to 60% of the pore throat capacity. However, this could occur over a range of 10 to 90% utilization of pore throat capacity. Breakthrough occurs in the microchannel phase separator at conditions similar to the annular to plug flow transition of two-phase microgravity pipe flow implying that operating in the proper flow regime is crucial. Analysis indicates that the Bond number did not affect performance, supporting the premise that hydrodynamic, interfacial, and capillary forces are more important than gravity. However, the relative importance of gravity is better discerned through testing under reduced gravity conditions.

TeGrotenhuis, Ward E.↗

Information for Lateral Aircraft Spacing Enabling Closely-Spaced Runway Operations During Instrument-Weather Conditions

In an effort to increase airport capacity, the U.S. plans on investing nearly $6 billion a year to properly maintain and improve the nation's major airports. Current FAA standards however, require a reduction in terminal operations during instrument-weather conditions at many airports, causing delays and reducing airport capacity. NASA, in cooperation with the FAA, has developed the Terminal Area Productivity Program to achieve clear-weather capacity in instrument- weather conditions for all phases of flight. This paper describes a series of experiments planned to investigate the conceptual design of different systems that provide information to flight crews regarding nearby traffic during the approach phase of flight. The purpose of this investigation is to identify and evaluate different display and auditory interfaces to the crew for use in closely-spaced parallel runway operations. Three separate experiments are planned for the investigation. The first two experiments will be conducted using part-task flight simulators located at the MIT Aeronautical Systems Laboratory and at NASA Ames. The third experiment will be conducted in the Advanced Concepts Flight Simulator, a generic "glass-cockpit" simulator at NASA Ames. Subjects for each experiment will be current glass-cockpit pilots from major U.S. air carriers. Subject crews will fly several experimental scenarios in which pseudo-aircraft are "blundered" into the subject aircraft simulation. Runway spacing, longitudinal aircraft separation, aircraft performance and traffic information will be varied. Analyses of the subject reaction times in evading the blundering aircraft and the resulting closest points of approach will be conducted. This paper presents a preliminary examination of the data recorded during the part-task experiments. The impact of traffic information on closely-spaced parallel runway operations is discussed, cockpit displays to aid these operations are examined, and topics for future research are suggested.

Thrush, Trent↗