Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Blind”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 883 records · Page 49

TDCOSMO XXIII. Measurement of the Hubble constant from the doubly lensed quasar HE 1104−1805

Time-delay cosmography leverages strongly lensed quasars to measure the Universe’s current expansion rate, H 0 , independently from other methods. The latest TDCOSMO milestone measurement primarily used quadruply lensed quasars for their mass profile constraints. However, doubly lensed quasars, being more abundant and offering precise time delays, could expand the sample by a factor of 5, significantly advancing towards a 1% precision measurement of H 0 . We present the first TDCOSMO analysis of a doubly imaged source, HE 1104−1805, including the measurement of the four necessary ingredients. First, by combining 17 years of data from the SMARTS, Euler, and WFI telescopes, we measured a time delay of 176.3 +11.4 −10.3 days. Second, using MUSE data, we extracted stellar velocity dispersion measurements in three radial bins with 5% to 13% precision. Third, employing F160W HST imaging for lens modelling and marginalising over various modelling choices, we measured the Fermat potential difference between the images. Fourth, using wide-field imaging, we measured the convergence added by objects not included in the lens modelling. By combining these four ingredients, we measured the time delay distance and the angular diameter distance to the deflector, favouring a power-law mass model over a baryonic and dark matter composite model. The measurement was performed blindly to prevent experimenter bias and resulted in a Hubble constant of H 0 = +5.8 −5.0 × λ int km s −1 Mpc −1 , where λ int is the internal mass sheet degeneracy parameter. This is in agreement with the TDCOSMO-2025 milestone and its precision for λ int = 1 is comparable to that obtained with the best-observed quadruply lensed quasars (4–6%). This work is a stepping stone towards a precise measurement of H 0 using a large sample of doubly lensed quasars, supplementing the current sample. The next TDCOSMO milestone paper will include this system in its hierarchical analysis, constraining λ int and H 0 jointly with multiple lenses.

cosmological parameters↗

Efficient Full-Field Vibration Measurements and Operational Modal Analysis Using Neuromorphic Event-Based Imaging

Traditional vibration measurement typically requires physically attached sensors, such as accelerometers and strain gauges. However, these discrete-point sensors provide only low spatial resolution vibration measurements, potentially foregoing valuable structural information such as localized damage. Noncontact optical measurement methods such as laser vibrometers can achieve high spatial resolution vibration measurements but only through time-consuming sequential measurements and are not cost-effective. As an alternative to traditional vibration measurement methods, digital video cameras are relatively low-cost, agile, and offer noncontact, simultaneous high spatial resolution measurements where every pixel on the structure becomes a measurement point. However, regular digital video cameras are frame-based where each pixel simultaneously performs temporally uniform (synchronous) measurements containing large amounts of redundant (background) data, which consumes considerable resources for video data measurement, management, and processing. To alleviate such a challenge, this work explores the use of event-based neuromorphic imagers, specifically silicon retinas, an efficient alternative to traditional frame-based video cameras, to perform full-field vibration measurements and operational modal analysis. By imitating biological vision, each silicon retina pixel independently and asynchronously records only intensity change events that contain structural motion information while excluding redundant (background) information. Such an asynchronous event-based data measurement mechanism allows for structural motion to be captured on the microsecond scale in an extremely data-efficient manner, which could benefit real-time vibration measurement and control applications. This study takes the first step toward these applications by formulating an existing video frame-based full-field operational modal analysis technique in the event-based, asynchronous silicon retina measurement framework. Specifically, local phase-based motion extraction and blind source separation are used to automatically and efficiently extract full-field vibration and dynamics parameters from silicon retina measurements. The developed method is validated by laboratory experiments on a bench-scale cantilever beam.

42 ENGINEERING↗

Gamma-Ray Pulsar Studies with GLAST

Some pulsars have their maximum observable energy output in the gamma-ray band, offering the possibility of using these high-energy photons as probes of the particle acceleration and interaction processes in pulsar magnetospheres. After an extended hiatus between satellite missions, the recently-launched AGILE mission and the upcoming Gamma-ray Large Area Space Telescope (GLAST) Large Area Telescope (LAT) will allow gamma-ray tests of the theoretical models developed based on past discoveries. With its greatly improved sensitivity, better angular resolution, and larger energy reach than older instruments, GLAST LAT should detect dozens to hundreds of new gamma-ray pulsars and measure luminosities, light curves, and phase-resolved spectra with unprecedented resolution. It will also have the potential to find radio-quiet pulsars like Geminga, using blind search techniques. Cooperation with radio and X-ray pulsar astronomers is an important aspect of the LAT team's planning for pulsar studies.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The Steady State Challenge for Soft X-Ray Diagnostics on Wendelstein 7-X Stellarator

The steady state operation of Wendelstein 7-X stellarator presently under construction in Greifswald poses special challenges to the diagnostics development [1, 2]. A critical issue is the heat load on plasma facing components ({approx}500 kW/m{sup 2}) over a long discharge time (up to 30 min), which leads to the necessity of active cooling. As result, the design of the 400 channel soft X-Ray Multi Camera Tomography System (XMCTS) [2, 3] has to cope with dark currents and amplifier drifts due to the heating of active components like photo diodes and in-vessel preamplifiers. In order to allow for a quantitative measurement of dynamic drifts and offsets, a shutter system and blind diodes are considered to compensate these effects. Another important issue is the large amount of data gathered by the XMCT system during long pulse discharges. A fast but less precise online reconstruction is planned, which will give information on the plasma shape and position on a human time scale. The two options under investigation are a Cormack-Inversion method and an approach based on neural networks [4]. Dependent on the available hardware, as much information as possible should be stored for more accurate offline-analysis. An intelligent way of marking interesting data is required. In case that the steady-state storage of all measured data is not feasible, at least this marked data will be stored in high time resolution.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

First Dark Matter Results from the CDMS 5-Tower Run and the path towards {sigma} = 10{sup -46} cm{sup 2} Wimp sensitivity

This paper will report on the recently released results from the Cryogenic Dark Matter Search (CDMS II) experiment. Data from 30 cryogenic particle detectors operated at the Soudan Underground Laboratory between October 2006 and July 2007 was collected. The results from from a blind analysis of 15 Ge detectors corresponding to total exposure of 121.3 kg-d (averaged over the recoil energy range 10-100 keV, and weighted for a weakly interacting massive particle (WIMP) mass of 60 GeV/c{sup 2}) are presented here. With zero observed events an upper limit on WIMP-nucleon spin-independent cross section of 6.6x10{sup -44} cm{sup 2} is obtained from this data set alone. The limit improves to 4.6x10{sup -44} cm{sup 2} when combined with previous CDMS data. The paper will also describe current efforts at designing and building larger mass detectors ({approx}few kg/detector) which will form the basis of a future 1-Ton cryogenic Ge detector experiment.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

PET examination in intracranial tumor diagnosis of a cat

This paper shows the significance of the Positron Emission Tomography (PET) in the veterinary medication through a case study of a cat brain tumor. A castrated male cat with bilateral mydriasis and blindness arrived at the veterinary clinic. After physical, laboratory and neurological investigations other sickness was ruled out and the inkling of the intracranial lesion had come to light. Brain tumor seemed the most likely to cause the illness because other symptoms appeared (for example: anorexia, depression) and they progrediated fast. PET examination, using {sup 18}F-FDG isotope, was performed to confirm the possible causes of the cat's symptoms.

60 APPLIED LIFE SCIENCES↗

The Large-Area Time-Of-Flight (TOF) Upgrade for the STAR Detector

The STAR experiment at RHIC concentrates on the tracking of charged hadrons via ionization in gas- and silicon-based detectors, and the detection of electrons and photons via calorimetry, in a wide and azimuthally complete acceptance that's unique at RHIC. STAR's ability to directly identify the tracked charged hadrons is however limited to low momenta. Approximately half of the charged particles in the event at higher momenta cannot be directly identified, which hampers the physics reach of STAR in a number of key areas. To address this blind spot, STAR is presently constructing a large-area ({approx}50 m{sup 2}) Time-Of-Flight (TOF) system. This system is based on Multi-gap Resistive Plate Chambers (MRPCs). Prototype TOF systems based on this technology were operated in STAR during RHIC Runs 3 through 6, and the first 5 final-system trays were operated in the recent RHIC Run 8. A new 'start detector' for this system has also been constructed and operated in STAR. The performance of these detectors in STAR, and an update on the status of the construction of the full system, is discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Resolution of Ion Mobility Spectra for the Detection of Hazardous Substances in Real Sampling Conditions

This work presents the possibilities offered by a blind source separation method such Multivariate Curve Resolution- Alternating Least Squares (MCR-ALS) in the analysis of Ion Mobility Spectra (IMS). Two security applications are analyzed in this context: the detection of TNT both in synthetic and real samples. Results obtained show the possibilities offered by the direct analysis of the drift time spectra when an appropriate resolution method is used.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Lepton flavour violating slepton decays to test type-I and II seesaw at the LHC

Searches at the LHC of lepton flavour violation (LFV) in slepton decays can indirectly test both type-I and II seesaw mechanisms. Assuming universal flavour-blind boundary conditions, LFV in the neutrino sector is related to LFV in the slepton sector by means of the renormalization group equations. Ratios of LFV slepton decay rates result to be a very effective way to extract the imprint left by the neutrino sector. Some neutrino scenarios within the type-I seesaw mechanism are studied. Moreover, for both type-I and II seesaw mechanisms, a scan over the minimal super-gravity parameter space is performed to estimate how large LFV slepton decay rates can be, while respecting current low-energy constraints.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

MFV and the SUSY CP Problem

The principle of Minimal Flavour Violation (MFV) provides a natural solution to the SUSY flavour problem, but does not solve the SUSY CP problem as it allows for the presence of new CP-violating phases. If the MFV principle is generalized by the assumption of CP conservation in the limit of flavour blindness, the SUSY CP problem can be solved, predicting at the same time interesting CP violating phenomenology.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

High-Energy Observation of GRB 090217 with Fermi

The Fermi observatory is advancing our knowledge of Gamma-Ray Bursts (GRBs) through pioneering observations at high energies, covering more then 7 decades of energy with the two on-board detectors, the Large Area Telescope (LAT) and the Gamma-ray Burst Monitor (GBM). Here we report on the observation of long GRB 090217 which triggered the GBM and as been independently detected by the on-ground blind search LAT algorithm. We present the GBM and LAT observations, including a temporal profile and time-resolved spectral analysis from 8 keV up to approx1 GeV. The time-averaged and time-resolved spectra are well reproduced by a Band model, with no substantial spectral evolution. We compare these observations to the other LAT detections of long bursts, and discuss some theoretical implications on GRB high-energy emission.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Reduction Of Chronic Musculoskeletal Pain With Cranial Laser Reflex Technique (CLRT): A Randomized Controlled Trial Using Pressure Algometry

Cranial Laser Reflex Technique (CLRT) is a novel method involving a brief low level laser stimulation of specific cranial reflex points to reduce musculoskeletal pain. Objective: The objective of the study was to compare the immediate effects of CLRT with a sham treatment on chronic musculoskeletal pain using pressure algometry in a double-blinded randomized controlled trial. Methods: Fifty-seven (57) volunteers with various musculoskeletal pains gave informed consent and were randomly allocated to either the CLRT treatment or sham group. Painful trigger points and/or tender spinal joints were found in each patient. Using a digital algometer, the pain/pressure threshold (PPT) was determined and a pain rating was given using a numerical pain scale from 0-10. CLRT or a sham treatment was performed with a 50 mW, 840 nm laser, for a maximum of 20 seconds to the each cranial reflex. The initial pressure (PPT) was immediately delivered to the same spot, and the pain rated again. Results: There was a statistically significant difference in pain scores between CLRT and sham groups immediately following treatment. Improvement was reported in 95% of the treatment group, with 59% reporting an improvement of 2 points or greater. The average change in pain scores in the treatment group was 2.6 points (p 0.000) versus negligible change (p= 0.4) for the control group. Conclusion: The results show that CLRT is effective at immediately reducing chronic musculoskeletal pain. Further studies are needed with additional outcome measures to.

60 APPLIED LIFE SCIENCES↗

Diamond Photodetectors for X-Ray Absorption Spectroscopy Applications

Synchrotron radiation (SR) is a fundamental tool for X-ray research. In particular, X-ray absorption spectroscopy (XAS) accesses information as electronic properties, local structure or chemical-physical state in condensed-matter studies. Ionization chambers (ICs) are the most widely used XAS detectors for transmission measurements because of their reliability, high linearity and good stability. Recently, solid-state detectors have been considered and Si p-i-n has been applied to high fluxes (10{sup 11} ph/s), where the linearity of ICs is no longer guaranteed. Silicon photodiodes exhibit an extremely linear response in at least 5 decades but show diffraction peaks. Diamond is an ideal substrate to produce radiation-hard, low dark current (<1 pA/cm{sup 2}), visible-blind and fast-response X-ray detectors with a high S/N ratio. Diamond detectors were tested as SR monitor capable to withstand the high photon flux density of the 3{sup rd} generation SR sources. Being the lowest X-ray-absorbing solid-state dielectric material, diamond maximizes the flux through thin self-standing devices with minimal spectral effect down to the soft x-ray range. We will present results of X-ray tests of photoconductors based on different diamond substrates. The results will be compared to standard ICs for XAS applications in terms of spectral quality, noise and linearity in the 4-13 keV energy range.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Spatially distributed scintillator arrays for diagnosing runaway electron transport and energy behavior in tokamaks

We present details of a new bismuth germanate [Bi{sub 4}Ge{sub 3}O{sub 12} (BGO)] scintillator array used to diagnose the transport and energy behavior of runaway electrons (REs) in DIII-D. BGO exhibits important properties for these compact detectors including high light yield which sufficiently excites photodiode detectors (8500 photons/MeV), high density and atomic numbers of constituent materials which maximizes sensitivity, and relative neutron blindness which minimizes complications in data interpretation. The detectors observe primarily hard x-ray radiation emitted in a forward beamed pattern by RE when they strike first wall materials or bulk ions and neutrals in the plasma, although we also address photoneutron signals. The arrangement of the array enables time resolved location of x-ray emission and associated asymmetries which help identify instabilities and confinement properties of RE. By shielding a subset of detectors with different thicknesses of lead, and with interpretative support of the code EGSNRC, we also measure RE energy, although due to the often distributed nature of RE strike points and the forward beamed character of emitted hard x-rays, we restrict interpretation as a lower bound for RE energy.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Observations of Langmuir ponderomotive effects using the Solar TErrestrial RElations Observatory spacecraft as a density probe

Langmuir ponderomotive effects are nonlinear effects that enable to couple the electron and ion dynamics in space plasmas. The main difficulty to provide observational evidence of such nonlinear coupling is to simultaneously observe both fluctuations of plasma density and electric field. We have thus developed a new method to measure and to calibrate in situ small scale density fluctuations. Density fluctuations in the solar wind are measured using the observed quasistatic fluctuations of the STEREO spacecraft floating potential in the frequency range, where the spacecraft floating potential is in quasistatic equilibrium between photoionization and electron attachment, whereas the potential of the antenna, of much longer equilibrium time scale, is blind to the density fluctuations. Density fluctuations and Langmuir waves are thus directly and simultaneously measured using a dataset of more than three years of STEREO/WAVES measurements. We present here the first observational evidence for ponderomotive effects in the solar wind that nonlinearly couple density fluctuations to high energy Langmuir waves (({epsilon}{sub 0}E{sup 2})/(nk{sub B}T)>10{sup -4}).

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Lattice Simulations in MOM v.s. Schroedinger Functional Scheme and Triality

The QCD beta function extracted from polarized electron proton scattering data obtained at JLab and the lattice simulation in the MOM scheme suggest that the critical flavor number for the presence of IR fixed point is about three. In analyses of Schroedinger functional scheme, however, critical flavor number for the presence of IR fixed point and the conformality is larger than nine.In the QCD analysis, when quarks are expressed in quaternion basis, the product of quaternions are expressed by octonions and the octonion posesses the triality symmetry. Since the triality has the effect of multiplying the falvor number, it could explain the apparent large critical flavor number in the Schroedinger functinal scheme. In this scheme, larger degrees of freedom in adjusting data of different scales on the boundary are necessary than in the MOM scheme.In weak interaction, there is no clear lepton-flavor violation except in the neutrino oscillation. If the triality is assigned to the lepton flavors(e,{mu} and {tau}) and they are assumed to be exact symmetry, or the electro-magnetic interaction preserves tiality, but the strong interaction is triality blind, there is a possibility of explaining the neutrino oscillation through triality mixing of the matter field.The self energy of gluons, ghost and gauge bosons due to self-dual gauge fields and leptonic decays of B,D and D{sub s} mesons are discussed.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Structure and prospects of the simplest SO(10) GUTs

We recapitulate the latest results on the class of the simplest SO(10) grand unified models in which the GUTscale symmetry breaking is triggered by an adjoint Higgs representation. We argue that the minimal survival approximation traditionally used in the GUT-and seesaw-scale estimates tends to be blind to very interesting parts of the parameter space in which some of the intermediate-scale states necessary for non-supersymmetric unification of the SM gauge couplings can be as light as to leave their imprints in the TeV domain. The stringent minimal-survival-based estimates of the B - L scale are shown to be relaxed by as much as four orders of magnitude, thus admitting for a consistent implementation of the standard seesaw mechanism even without excessive fine-tuning implied by the previous studies. The prospects of the minimal renormalizable SO(10) GUT as a potential candidate for a well-calculable theory of proton decay are discussed in brief.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗