Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “BLOOD VESSELS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 883 records · Page 49

Dynamic Computed Tomography Angiography: Role in the Evaluation of Popliteal Artery Entrapment Syndrome

This study reviews our experience with dynamic computed tomographic angiography (CTA) as an imaging modality in the evaluation of popliteal artery entrapment syndrome (PAES). Eight patients with surgically proven PAES were included in this study. Dynamic CTA studies performed with the feet in neutral and plantar flexed positions were reviewed for the detailed anatomy of the region and to define the location and extent of the stenosis, occlusions and collateral circulation. These findings were compared with intraoperative observations. CTA provided adequate angiographic and anatomic information required to arrive at the diagnosis and make a surgical decision. Thirteen limbs were affected in eight patients. There was popliteal artery occlusion in four limbs, stenosis at rest that was accentuated on stress imaging in two limbs, and patent popliteal artery with marked stenosis on stress imaging in seven limbs. Long-segment stenosis was seen in functional entrapment compared to short-segment stenosis in anatomic PAES. Anteroposterior compression of the popliteal artery in anatomic PAES unlike the side-to-side compression in functional PAES was a unique observation in this study. The CTA and surgical characterisation and classification of PAES matched in all the patients, except for misinterpretation of compressing fibrous bands as accessory slips of muscles in three limbs. In conclusion, dynamic CTA is a robust diagnostic tool that provides clinically relevant information and serves as a rapidly performed and easily available 'one-stop-shop' imaging modality in the management of PAES.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Endovascular Stent Treatment for Symptomatic Benign Iliofemoral Venous Occlusive Disease: Long-Term Results 1987-2009

Venous stenting has been shown to effectively treat iliofemoral venous obstruction with good short- and mid-term results. The aim of this study was to investigate long-term clinical outcome and stent patency. Twenty patients were treated with venous stenting for benign disease at our institution between 1987 and 2005. Fifteen of 20 patients (15 female, mean age at time of stent implantation 38 years [range 18-66]) returned for a clinical visit, a plain X-ray of the stent, and a Duplex ultrasound. Four patients were lost to follow-up, and one patient died 277 months after stent placement although a good clinical result was documented 267 months after stent placement. Mean follow-up after stent placement was 167.8 months (13.9 years) (range 71 (6 years) to 267 months [22 years]). No patient needed an additional venous intervention after stent implantation. No significant difference between the circumference of the thigh on the stented side (mean 55.1 cm [range 47.0-70.0]) compared with the contralateral thigh (mean 54.9 cm [range 47.0-70.0]) (p = 0.684) was seen. There was a nonsignificant trend toward higher flow velocities within the stent (mean 30.8 cm/s [range 10.0-48.0]) and the corresponding vein segment on the contralateral side (mean 25.2 cm/s [range 12.0-47.0]) (p = 0.065). Stent integrity was confirmed in 14 of 15 cases. Only one stent showed a fracture, as documented on x-ray, without any impairment of flow. Venous stenting using Wallstents showed excellent long-term clinical outcome and primary patency rate.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Metachronous Bilateral Posterior Tibial Artery Aneurysms in Ehlers-Danlos Syndrome Type IV

Ehlers-Danlos syndrome type IV is a life-threatening genetic connective tissue disorder. We report a 24-year-old woman with EDS-IV who presented with metachronous bilateral aneurysms/pseudoaneurysms of the posterior tibial arteries 15 months apart. Both were treated successfully with transarterial coil embolization from a distal posterior tibial approach.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Cutting-Balloon Angioplasty in Transplant Renal Artery Stenosis as First-Line Treatment in the Early Postoperative Period

Percutaneous transluminal angioplasty has been successfully used for the treatment of transplant renal artery stenosis (RAS). Cutting-balloon angioplasty (CBA) is being used as a second option in pressure-resistant stenosis. It is thought that CBA is less traumatic and therefore restenosis occurs less frequently than in conventional angioplasty. This case report describes the unusual use of a cutting balloon in transplant RAS as a first option in the early postoperative period. Long-term follow-up data are also presented.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Porous Gelatin Particles for Uterine Artery Embolization: An Experimental Study of Intra-Arterial Distribution, Uterine Necrosis, and Inflammation in a Porcine Model

PurposeWe evaluated the location of porous gelatin particles (GP; Gelpart; Nippon Kayaku/Astellas, Tokyo, Japan) within the arterial vasculature and their acute effects on uterine necrosis and inflammation after uterine artery embolization (UAE) in swine.Materials and MethodsAdult nonpregnant pigs (n = 6) were allocated to either 1- (n = 3) or 2-mm GP (n = 3). Superselective and bilateral embolization of the uterine arteries was performed. All animals were killed 1 week after UAE. Macroscopic and microscopic findings, including the level of arterial occlusion and their effect on uterine necrosis and inflammation, were analyzed.ResultsAll UAE procedures were completed without severe complications. The macroscopic necrosis was seen in two animals in the 2-mm group with an extent of <50%. The location of the occluded arteries did not differ significantly between groups. The median diameters of the occluded arteries were 449 {mu}m (95% confidence interval [CI] 417-538 {mu}m) in the 1-mm GP group and 484 {mu}m (95% CI 370-560 {mu}m) in the 2-mm GP group. As for microscopic necrosis, no statistically significant difference was observed. The qualitative inflammatory reaction was significantly greater in the 2-mm GP group than in the 1-mm group (p < 0.001).ConclusionsBoth 1- and 2-mm GP occluded the arteries relevant to the target diameter for UAE in porcine uterus, presumably due to the plastic deformity. Both sizes of GP were associated with limited areas of necrosis; however, evaluation of inflammatory reaction was preliminary. Further study with adequate evaluation of inflammatory reactions is suggested.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Final Results of the Protected Superficial Femoral Artery Trial Using the FilterWire EZ System

The purpose of this study was to evaluate the safety and efficacy of debris-capture for distal protection using the FilterWire EZ Embolic Protection System (Boston Scientific, Mountain View, CA) with the additional aim to further define the incidence of distal embolization during superficial femoral artery (SFA) interventions. A prospective, single-centre registry was designed to evaluate the performance of the FilterWire EZ in capturing debris during standard SFA percutaneous intervention. The PRO-RATA study included 30 patients suitable for PTA (Fontaine IIb to III or Rutherford I to II classification). The primary end points were occurrence of distal embolization or decreased runoff, improvement in ankle-brachial index ankle-brachial index (ABI) after the procedure, and number of filters containing emboli. Secondary end points included major adverse events (i.e., procedure- or device-related death and/or clinical target lesion revascularisation), device delivery, deployment success, and incidence of embolic recovery (patients with device success exhibiting embolic protection in the filter). Procedural success was determined as {<=}30% residual stenosis with no worsening of distal runoff as determined on angiography. A total of 29 patients (age 66.2 {+-} 12 years; total no. of limbs = 30; total no. of lesions = 30) suitable for PTA were enrolled in the study between February 2007 and March 2008. There were 26 patients with claudication (Fontaine IIB) and 3 patients with stage IV peripheral vascular disease. In one patient, lesions in both legs were treated. No procedural or device-related complications occured. The average degree of stenosis was 86 {+-} 7%. Stenosis length ranged from 8 to 88 mm. The average degree of residual stenosis was 10 {+-} 10%. ABI improved from 0.56 {+-} 0.16 to 0.92 {+-} 0.19 (P < 0.05). No restenosis or dissection was seen at 1-month ultrasound follow-up. Macroscopic debris was found in 27 of 30 filters of all distal protection devices used in all 29 patients. Debris particle size ranged from 90 to 2000 {mu}m (1200 {+-} 640). Histological debris analysis showed platelets, erythrocytes, inflammatory cells, extracellular matrix, and cholesterol as being the major components of emboli. Additional immunochemistry showed no correlation between lesion morphology and debris components. The FilterWire EZ is easy and safe to handle. The system caused no complications. In all cases, macroscopic debris was captured. Using a distal protection device during femoropopliteal interventions has the potential to prevent migration of debris, which may be important for high-risk patients with limited distal runoff.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Literature Review of the Role of Ultrasound, Computed Tomography, and Transcatheter Arterial Embolization for the Treatment of Traumatic Splenic Injuries

IntroductionThe spleen is the second most frequently injured organ following blunt abdominal trauma. Trends in management have changed over the years. Traditionally, laparotomy and splenectomy was the standard management. Presently, nonoperative management (NOM) of splenic injury is the most common management strategy in hemodynamically stable patients. Splenic injuries can be managed via simple observation (OBS) or with angiography and embolization (AE). Angio-embolization has shown to be a valuable alternative to observational management and has increased the success rate of nonoperative management in many series.DiagnosticsImproved imaging techniques and advances in interventional radiology have led to a better selection of patients who are amenable to nonoperative management. Despite this, there is still a lot of debate about which patients are prone to NOM.Angiography and EmbolizationThe optimal patient selection is still a matter of debate and the role of CT and angio-embolization has not yet fully evolved. We discuss the role of sonography and CT features, such as contrast extravasation, pseudoaneurysms, arteriovenous fistulas, or hemoperitoneum, to determine the optimal patient selection for angiography and embolization. We also review the efficiency, technical considerations (proximal or selective embolization), logistics, and complication rates of AE for blunt traumatic splenic injuries.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Staff Radiation Doses in a Real-Time Display Inside the Angiography Room

MethodsThe evaluation of a new occupational Dose Aware System (DAS) showing staff radiation doses in real time has been carried out in several angiography rooms in our hospital. The system uses electronic solid-state detectors with high-capacity memory storage. Every second, it archives the dose and dose rate measured and is wirelessly linked to a base-station screen mounted close to the diagnostic monitors. An easy transfer of the values to a data sheet permits further analysis of the scatter dose profile measured during the procedure, compares it with patient doses, and seeks to find the most effective actions to reduce operator exposure to radiation.ResultsThe cumulative occupational doses measured per procedure (shoulder-over lead apron) ranged from 0.6 to 350 {mu}Sv when the ceiling-suspended screen was used, and DSA (Digital Subtraction Acquisition) runs were acquired while the personnel left the angiography room. When the suspended screen was not used and radiologists remained inside the angiography room during DSA acquisitions, the dose rates registered at the operator's position reached up to 1-5 mSv/h during fluoroscopy and 12-235 mSv/h during DSA acquisitions. In such case, the cumulative scatter dose could be more than 3 mSv per procedure.ConclusionReal-time display of doses to staff members warns interventionists whenever the scatter dose rates are too high or the radiation protection tools are not being properly used, providing an opportunity to improve personal protection accordingly.

61 RADIATION PROTECTION AND DOSIMETRY↗

Transcatheter Arterial Embolization for Spontaneous Rupture of the Omental Artery

We encountered a rare case of spontaneous rupture of the omental artery. A 25-year-old man without any episode of abdominal trauma or bleeding disorders came to the emergency unit with left upper abdominal pain. Hematoma with extravasation of the greater omentum and a hemoperitoneum was confirmed on abdominal contrast-enhanced computed tomography. Bleeding from the omental artery was suspected based on these findings. Transcatheter arterial embolization was successfully performed after extravasation of the omental artery, which arises from the left gastroepiploic artery, was confirmed on arteriography. Partial ometectomy was performed 10 days after transcatheter arterial embolization, revealing that the hematoma measured 10 cm in diameter in the greater omentum. Pathological examination showed rupture of the branch of an omental artery without abnormal findings, such as an aneurysm or neoplasm. Thus, we diagnosed him with spontaneous rupture of the omental artery. The patient recovered and was discharged from the hospital 10 days after the surgery, with a favorable postoperative course.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Large Posttraumatic Subclavian Artery Aneurysm Complicated by Artery Occlusion and Arteriobronchial Fistula Successfully Treated Using a Covered Stent

The treatment of posttraumatic aneurysms of peripheral arteries using covered stents is increasingly commonplace. We present the case of a 10-year-old girl with a pseudoaneurysm of the subclavian artery complicated by an arteriobronchial fistula with hemorrhaging into the bronchial tree and distal subclavian artery occlusion. Despite the lack of artery patency, endovascular stent graft implantation was successful. Pseudoaneurysm exclusion and involution was achieved, together with a patent implant and maintained collateral circulation patency.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Long-Term Safety and Effectiveness of the 'OptEase' Vena Cava Filter

Purpose: To assess the long-term safety and effectiveness of the OptEase inferior vena cava (IVC) filter. Materials and Methods: In this Institutional Review Board-approved, retrospective study, we reviewed data of 71 patients who received an OptEase filter at our institution from 2002 to 2007. Thirty-nine (55%) patients had symptoms of venous thromboembolism before filter placement. The indications for filter included contraindication to anticoagulation in 31 (44%) patients, prophylaxis against pulmonary embolism (PE) in 29 (41%) patients, and failure of anticoagulation in 11 (15%) patients. Procedure-related complications, such as symptomatic post-filter PE, deep venous thrombosis (DVT), IVC occlusion, and incidental imaging-evident filter-related complications, were recorded. Safety was assessed by the occurrence of filter-related complications during placement and follow-up. Effectiveness was assessed by the occurrence of post-filter PE. Results: Sixty-five (92%) filters were placed under fluoroscopy, and 6 (8%) were placed using intravascular ultrasound guidance. Seventy (99%) filters were placed successfully. Seven (10%) filters were placed in the suprarenal cava. Retrieval was attempted in 14 (20%) patients, and 12 filters were successfully retrieved. Clinical follow-up was available for 20 {+-} 21 months. Symptoms of postfilter PE and DVT occurred in 15% (n = 11) and 10% (n = 7) patients, respectively. None of these patients had computed tomography (CT)-proven PE, and only one had ultrasound-proven new DVT. One patient had symptomatic IVC occlusion. Follow-up abdominal CT in 20 patients showed thrombus in the filter in two of them. There were no instances of filter migration, filter tilt, or caval wall penetration. Conclusion: The OptEase filter appears to have an acceptable long-term safety profile. The filter was effective against PE.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Stent-Assisted Coil Embolization of a Mycotic Renal Artery Aneurysm by Use of a Self-Expanding Neurointerventional Stent

Mycotic aneurysms are uncommon, especially those located in visceral arteries. We present a case of a patient with two visceral mycotic aneurysms due to bacterial endocarditis, one located in right upper pole renal artery and the second in the splenic artery. Both aneurysms were treated as endovascular embolization using microcoils. In the aneurysm located at the renal artery, the technique of stent-assisted coils embolization was preferred to avoid coils migration due to its wide neck. The stent used was the Solitaire AB, which was designed for the treatment of intracranial aneurysms and was used recently in acute stroke as a mechanical thrombectomy device. Complete embolization of the aneurysm was achieved, preserving all the arterial branches without nephrogram defects in the final angiogram.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Transcatheter Arterial Chemoembolization with Epirubicin-Loaded Superabsorbent Polymer Microspheres for 135 Hepatocellular Carcinoma Patients: Single-Center Experience

Purpose: To evaluate the safety, clinical outcomes, and hepatic artery damage after transcatheter arterial chemoembolization (TACE) with epirubicin-loaded superabsorbent polymer microspheres (ELM-TACE) in patients with hepatocellular carcinoma (HCC) in a single center in Japan. Materials and Methods: This embolic agent is the original form of microspheres, which has the same composition and nature as HepaSpheres. Between May 2007 and June 2009, 135 patients with unresectable HCC who underwent ELM-TACE were enrolled. Embolization through extrahepatic collaterals was performed in 27 (20.0%) patients. Tumor response was evaluated using European Association for the Study of the Liver criteria at 1 and 6 months after initial ELM-TACE. Results: All procedures were successfully performed. The median number of TACE per patient was 1.7 sessions (range 1-5), and the mean epirubicin dose per session was 19.7 mg (range 2.0-60.0). Local pooling within target tumors was observed during TACE in 34 (25.2%) patients, and in 14 (10.4%) of the patients, gelatin sponge particles were added after the microspheres until each pooling disappeared. No serious adverse events associated with TACE occurred, and the incidence of postembolization syndrome was {<=}17.8%. The 1- and 6-month tumor response rates were 56.3 and 52.6%, respectively. The overall 1- and 2-year survival rates were 73.7 and 59.0%, respectively. Among 99 evaluated patients, 90 (90.9%) were found to have no hepatic artery damage after initial ELM-TACE. Conclusion: ELM-TACE is safe and effective treatment for unresectable HCC and is associated with low frequency of postembolization syndrome and minimal damage to the hepatic artery.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Iatrogenic Subtotal Stenosis of the Right Subclavian Artery Treated With Percutaneous Transluminal Angioplasty

This report describes a rare vascular complication of surgical placement of a marking clip and a possible approach to problem solving. A 55-year-old patient presented with loss of sensation in the fingers and loss of peripheral pulsations in the right arm 4 days after right upper lobectomy for a pT2N1 moderately differentiated adenocarcinoma of the lung. Duplex examination and computed tomography were performed the same day and showed a subtotal stenosis of the right subclavian artery, which was caused by the surgical placement of a metal clip to mark the surgical boundary. Selective angiography was subsequently performed. Percutaneous transluminal angioplasty (PTA) successfully dilated the stenosis and pushed the clip off. Flow in the right subclavian artery (RSA) was completely restored as were neurology and peripheral pulses. In conclusion, arterial stenosis by a surgical (marking) clip may be feasibly treated with PTA.

62 RADIOLOGY AND NUCLEAR MEDICINE↗