Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “BIFURCATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 883 records · Page 49

Geometric entropies and their Hamiltonian flows

In holographic theories, the Hubeny-Rangamani-Takayanagi (HRT) area operator plays a key role in our understanding of the emergence of semiclassical Einstein-Hilbert gravity. When higher derivative corrections are included, the role of the area is instead played by a more general functional known as the geometric entropy. It is thus of interest to understand the flow generated by the geometric entropy on the classical phase space. In particular, the fact that the associated flow in Einstein-Hilbert or Jackiw-Teitelboim (JT) gravity induces a relative boost between the left and right entanglement wedges is deeply related to the fact that gravitational dressing promotes the von Neumann algebra of local fields in each wedge to type II. This relative boost is known as a boundary-condition-preserving (BCP) kink-transformation. In a general theory of gravity (with arbitrary higher-derivative terms), it is straightforward to show that the flow continues to take the above geometric form when acting on a spacetime where the HRT surface is the bifurcation surface of a Killing horizon. However, the form of the flow on other spacetimes is less clear. In this paper, we use the manifestly-covariant Peierls bracket to explore such flows in two-dimensional theories of JT gravity coupled to matter fields with higher derivative interactions. The results no longer take a purely geometric form and, instead, demonstrate new features that should be expected of such flows in general higher derivative theories. We also show how to obtain the above flows using Poisson brackets.

AdS-CFT correspondence↗

Black hole horizon edge partition functions

We extend a formula for 1-loop black hole determinants by Denef, Hartnoll, and Sachdev (DHS) to spinning fields on any (d + 1)-dimensional static spherically symmetric black hole. By carefully analyzing the regularity condition imposed on the Euclidean eigenfunctions, we reveal an unambiguous bulk-edge split in the 1-loop Euclidean partition function for tensor fields of arbitrary integer spin: the bulk part captures the “renormalized” thermal canonical partition function recently discussed in [1]; the edge part is related to quasinormal modes (QNMs) that fail to analytically continue to a subset of Euclidean modes with enhanced fall-offs near the origin. Since the edge part takes the form of a path integral on S d–1 , this suggests that these are associated with degrees of freedom living on the bifurcation surface in the Lorentzian two-sided black hole geometry. For massive higher spin on static BTZ and massive vector on Nariai black holes, we find that the edge partition function is related to the QNMs with lowest overtone numbers.

79 ASTRONOMY AND ASTROPHYSICS↗

Fuzzy spheres in stringy matrix models: quantifying chaos in a mixed phase space

We consider a truncation of the BMN matrix model to a configuration of two fuzzy spheres, described by two coupled non-linear oscillators dependent on the mass parameter μ. The classical phase diagram of the system generically (μ ≠ 0) contains three equilibrium points: two centers and a center-saddle; as μ → 0 the system exhibits a pitchfork bifurcation. We demonstrate that the system is exactly integrable in quadratures for μ = 0, while for very large values of μ, it approaches another integrable point characterized by two harmonic oscillators. The classical phase space is mixed, containing both integrable islands and chaotic regions, as evidenced by the classical Lyapunov spectrum. At the quantum level, we explore indicators of early and late time chaos. The eigenvalue spacing is best described by a Brody distribution, which interpolates between Poisson and Wigner distributions; it dovetails, at the quantum level, the classical results and reemphasizes the notion that the quantum system is mixed. We also study the spectral form factor and the quantum Lyapunov exponent, as defined by out-of-time-ordered correlators. These two indicators of quantum chaos exhibit weak correlations with the Brody distribution. We speculate that the behavior of the system as μ → 0 dominates the spectral form factor and the quantum Lyapunov exponent, making these indicators of quantum chaos less effective in the context of a mixed phase space.

AdS-CFT correspondence↗

Generalized entropy of gravitational fluctuations

The corrections to holographic entanglement entropy from bulk quantum fields in a classical gravitational background are now well understood. They lead, in particular, to unitary Page curves for evaporating black holes. However, the correct treatment of quantum fluctuations of the metric, including graviton excitations, is a longstanding problem. We provide a gauge-invariant prescription for the generalized entropy of gravitons in anti-de Sitter space in terms of areas and bulk entanglement entropy, generalizing the quantum extremal surface prescription to accommodate fluctuations in the semiclassical spacetime geometry. This task requires a careful treatment of the area operator on the graviton Hilbert space and the definition of a “quantum extremal gauge” in which the extremal surface is unperturbed. It also requires us to determine the correct vacuum modular Hamiltonian for the graviton field, which we fix by requiring that it doesn’t contain a boundary term in extremal gauge. We check our prescription with an explicit computation of the vacuum-subtracted generalized entropy of states containing a graviton in an AdS-Rindler background. Our results exactly match vacuum-subtracted von Neumann entropies for stress-tensor excited states in holographic conformal field theory with d > 2 dimensions. We also use covariant phase space techniques to give a partial proof of our prescription when the entanglement wedge for the background spacetime has a bifurcate Killing horizon. Along the way, we identify a class of perturbative graviton states that have parametrically larger generalized entropy, in the small G N expansion, than any low-energy excitations of an ordinary quantum field.

1/N expansion↗

Stringy ER = EPR

The ER = EPR correspondence relates a superposition of entangled, disconnected spacetimes to a connected spacetime with an Einstein-Rosen bridge. We construct examples in which both sides may be described by weakly-coupled string theory. The relation between them is given by a Lorentzian continuation of the FZZ duality of the two-dimensional Euclidean black hole CFT in one example, and in another example by continuation of a similar duality that we propose for the asymptotic Euclidean AdS 3 black hole. This gives a microscopic understanding of ER = EPR: one has a worldsheet duality between string theory in a connected, eternal black hole, and in a superposition of disconnected geometries in an entangled state. The disconnected description includes a condensate of entangled folded strings emanating from a strong-coupling region in place of a bifurcation point. Our construction relies on a Lorentzian interpretation of Euclidean time winding operators via angular quantization, as well as some lesser known worldsheet string theories, such as perturbation theory around a thermofield-double state, which we define using Schwinger-Keldysh contours in target space.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Splitting regions and shrinking islands from higher point constraints

We study constraints from higher-point amplitudes on 2 → 2 scattering in the context of effective field theory (EFT) using the perturbative numerical S-matrix bootstrap. Specifically, we investigate the class of weakly coupled EFTs with amplitudes that obey the hidden zero and split conditions that are known to hold both for Tr(Φ 3 ) theory and for certain string tree amplitudes, including at 4-point the beta function. Requiring the splitting condition for the 5-point amplitude not only fixes nearly all its contact terms, but it also imposes non-linear constraints among the 4-point EFT Wilson coefficients. When included in the bootstrap, the resulting allowed region consistent with positivity is no longer convex but is restricted to a smaller non-convex region — which has a sharp corner near the string beta function! Assuming the absence of an infinite spin tower at the mass gap, the allowed region bifurcates into a trivial region (with states only above a chosen cutoff) and an island that continues to shrink around the string as more constraints are included in the bootstrap. The numerics indicate that in the absence of single-mass infinite spin towers the string beta function is the unique 4-point amplitude compatible with hidden zero and the 5-point splitting constraints. The analysis provides a prototype example for how features of higher-point amplitudes constrain the bootstrap of 4-point amplitudes.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Endovascular Treatment of Anastomotic Pseudoaneurysms after Aorto-iliac Surgical Reconstruction

Purpose. To assess the effectiveness of endovascular treatment of anastomotic pseudoaneurysms (APAs) following aorto-iliac surgical reconstruction. Materials. We retrospectively evaluated 21 men who, between July 2000 and March 2006, were observed with 30 APAs, 13 to the proximal anastomosis and 17 to the distal anastomosis. The patients had had previous aorto-iliac reconstructive surgery with a bypass due to aneurysm (15/21) or obstructive disease (6/21). The following devices were used: 12 bifurcated endoprostheses, 2 aorto-monoiliac, 4 aortic extenders, 1 stent-graft leg, and 2 covered stents. Follow-up was performed with CT angiography at 1, 3, and 6 months after the procedure and yearly thereafter. Results. Immediate technical success was 100%. No periprocedural complications occurred. Four patients died during follow-up from causes not related to APA, and 1 (treated for prosthetic-enteric fistula) from sepsis 3 months after the procedure. During a mean follow-up of 19.7 months (range 1-72 months), 2 of 21 occlusions of stent-graft legs occurred 3 and 24 months after the procedure (treated with thrombolysis and percutaneous transluminal angioplasty and femorofemoral bypass, respectively) and 1 type I endoleak. Primary clinical success rate was 81% and secondary clinical success was 91%. Conclusion. Endovascular treatment is a valid alternative to open surgery and can be proposed as the treatment of choice for APAs, especially in patients who are a high surgical risk. Further studies with larger series and longer follow-up are necessary to confirm the long-term effectiveness of this approach.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Endovascular Reconstruction of Complex Arterial Obstructions in the Mesenteric Arcade with 'Kissing Stents': Technical Note

This report describes a technique for advanced endoluminal reconstruction of complex bifurcational arterial obstructions located within the mesenteric arcade deploying applications from percutaneous transluminal coronary artery angioplasty. A patient was treated for persistent mesenteric ischemia during prolonged recovery after initial small bowel resection due to acute mesenteric ischemia. Following endovascular reconstruction of a complex arterial obstruction within the mesenteric arcade, ischemic symptoms subsided quickly and the patient recovered well. According to the literature, this seems to be the first case where such distal reconstruction of the mesenteric arcade has successfully been achieved percutaneously.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Endovascular Aortic Aneurysm Repair with the Talent Stent-Graft: Outcomes in Patients with Large Iliac Arteries

The purpose of this study is to report outcomes following endovascular aneurysm repair (EVAR) of abdominal aortic aneurysm (AAA) in patients with ectatic common iliac arteries (CIAs). Of 117 AAA patients treated by EVAR between 1998 and 2005, 87 (74%) had CIAs diameters <18 mm and 30 (26%) patients had one or more CIA diameters >18 but <25 mm. All patients were treated with Talent stent-grafts, 114 bifurcated and 3 AUI devices. Departmental databases and patient records were reviewed to assess outcomes. Technical success, iliac-related outcome, and iliac-related reintervention (IRSI) were analyzed. Patients with EVAR extending into the external iliac artery were excluded. Median (range) follow-up for the study group was 24 (1-84) months. Initial technical success was 98% for CIAs <18 mm and 100% for CIAs {>=}18 mm (p = 0.551). There were three distal type I endoleaks (two in the ectatic group) and six iliac limb occlusions (one in an ectatic patient); there were no statistically significant differences between groups (p = 0.4). There were nine IRSIs (three stent-graft extensions, six femorofemoral crossover grafts); three of these patients had one or both CIAs {>=}18 mm (p = 0.232). One-year freedom from IRSI was 92% {+-} 3% and 84% {+-} 9% for the <18-mm and {>=}18-mm CIA groups, respectively (p = 0.232). We conclude that the treatment of AAA by EVAR in patients with CIAs 18-24 mm appears to be safe and effective, however, it may be associated with more frequent reinterventions.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Endovascular Repair of an Actively Hemorrhaging Stab Wound Injury to the Abdominal Aorta

Traumatic injury of the abdominal aorta is rare and potentially lethal (Yeh et al., J Vasc Surg 42(5):1007-1009, 2005; Chicos et al., Chirurgia (Bucur) 102(2):237-240, 2007) as it can result in major retroperitoneal hemorrhage, requiring an urgent open surgery. In case of concomitant bowel injury or other conditions of hostile abdomen, endovascular repair can be an alternative treatment. This case report deals with a 50-year-old man presenting at the emergency ward with three stab wounds: two in the abdomen and one in the chest. During explorative laparotomy, liver laceration and bowel perforation were repaired. One day later, abdominal CT-scan revealed an additional retroperitoneal hematoma associated with an aortic pseudoaneurysm, located anteriorly 3 cm above the aortic bifurcation. Because of the risk of graft infection, an endovascular repair of the aortic injury using a Gore excluder stent-graft was performed. Radiological and clinical follow-up revealed a gradual shrinkage of the pseudo-aneurysm and no sign of graft infection at two years' follow-up.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Percutaneous Treatment of Sac Rupture in Abdominal Aortic Aneurysms Previously Excluded with Endovascular Repair (EVAR)

The purpose of this study was to assess the feasibility and effectiveness of percutaneous endovascular repair of ruptured abdominal aortic aneurysms (AAAs) previously treated by EVAR. In the last year, two male patients with AAAs, treated 8 and 23 months ago with bifurcated stent-graft, were observed because of lumbar pain and hemorragic shock. Multidetector computed tomography (MDCT) showed a retroperitoneal hematoma; in both cases a type III endoleak was detected, in one case associated with a type II endoleak from the iliolumbar artery. The procedures were performed in the theater, in emergency. Type II endoleak was treated with transcatheter superselective glue injection; type III endoleaks were excluded by a stent-graft extension. The procedures were successful in both patients, with immediate hemodynamic stabilization. MDCT after the procedure showed complete exclusion of the aneurysms. In conclusion, endovascular treatment is a safe and feasible option for the treatment of ruptured AAAs previously treated by EVAR; this approach allows avoidance of surgical conversion, which is technical very challenging, with a high morbidity and mortality rate.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

CT Study of the Relationship Between the Common Iliac Artery and Vein and Their Juxtaposition: Implications for Conduit Construction Prior to Endosvascular Stent-Graft Repair of Aortic Aneurysms

The objective of this study was to determine the anatomical relationship and juxtaposition between the common iliac artery and vein in a population of patients with aortic aneurysmal disease and a population clinically and radiologically free of atheroma. It was a retrospective study of 100 consecutive patients undergoing computed tomographic assessment of abdominal aortic aneurysm prior to endovascular or open surgical repair and 100 patients undergoing computed tomographic assessment for other pathologies who did not have clinical or imaging signs of aorto-iliac atheroma. In both groups the anatomical relationship between the right and left iliac artery and vein was studied, and the thickness of the fat plane separating the artery from the vein measured. The right iliac vein was posterolateral to the artery at the level of the common iliac artery bifurcation in 95% of patients in both groups. At the same level the left iliac vein was posterior in 23% (p {<=} 0.001). Eighty-three percent of patients in the aneurysm group had a fat plane between the right artery and vein that measured 0 mm (no visible fat plane = 52%) to 1 mm (= 31%). Ninety-eight percent of patients in the aneurysm group had a measurable fat plane between the left iliac artery and vein of up to 5 mm (p = 0.001). Six percent of the control group demonstrated no visible fat plane between the right iliac artery and vein (p {<=} 0.001), while the fat plane measured more than 1 mm (1-5 mm) on the left in 100%. We conclude that in patients where conduit construction is required for aortic stent-graft access, the anatomical configuration and intimate relationship of the iliac arteries and veins should be assessed and taken into account at CT scan evaluation. The distal right common iliac artery should not be used, as venous damage can be predicted from the anatomical and intimate relationship of the iliac artery and vein at this level in patients with atheroma and the difficulties this relationship presents if venous repair is necessary.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Endovascular Management of Ruptured Abdominal Aortic Aneurysms: An 8-year Single-Centre Experience

We aimed to review our experience with the endovascular treatment of ruptured abdominal aortic aneurysm (RAAA). During an 8-year period, 69 patients with a RAAA presented to our department; 67 underwent assessment by computed axial tomography, and 2 died on arrival before any evaluation was possible. A total of 42 patients (63%) were suitable for stent-grafting, and all but 1 (c-arm failure) proceeded to endovascular repair. Of these, 27 underwent surgery with local anaesthesia; 3 did so under general anaesthesia; and a further 11 procedures were commenced with the patient under local anaesthesia and then converted to general anaesthesia. A total of 28 bifurcated and 14 aorto-uni-iliac stent-grafts were implanted. Aortic occlusion balloons were used in 2 (5%) patients. The in-hospital and the 30-day mortality rates were 36% and 41%, respectively. After surgery, 21 complications were encountered in 17 patients. Two patients required reintervention during their hospital stay (1 type I endoleak and 1 limb occlusion). During the follow-up (median 730 days [range 90 to 580 days]), the 1-year and 5-year cumulative survival probabilities were 53% (SE 7.9%) and 50% (SE 8.0%), respectively. Three reinterventions were necessary during follow-up (2 type I endoleaks and 1 graft occlusion). We conclude that endovascular treatment is feasible in the emergency setting, and the early experience is promising. Whether such an approach is superior to open surgery remains to be determined.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

High-Resolution CT and Angiographic Evaluation of NexStent Wall Adaptation

Carotid stenting is a minimally invasive treatment for extracranial carotid artery stenosis. Stent design may affect technical success and complications in a certain subgroup of patients. We examined the wall adaptability of a new closed-cell carotid stent (NexStent), which has a unique rolled sheet design. Forty-one patients had 42 carotid arteries treated with angioplasty and stenting for internal carotid artery stenosis. The mean patient age was 65 {+-} 10 years. All patients underwent high-resolution computed tomographic angiography after the stent implantation. Data analysis included pre- and postprocedural stenosis, procedure complications, plaque calcification, and stent apposition. We reviewed the angiographic and computed tomographic images for plaque coverage and stent expansion. All procedures were technically successful. Mean stenosis was reduced from 84 {+-} 8% before the procedure to 15.7 {+-} 7% after stenting. Two patients experienced transient ischemic attack; one patient had bradycardia and hypotension. Stent induced kinking was observed in one case. Good plaque coverage and proper overlapping of the rolled sheet was achieved in all cases. There was weak correlation between the residual stenosis and the amount of calcification. The stent provides adequate expansion and adaptation to the tapering anatomy of the bifurcation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Treatment of a Common Iliac Aneurysm by Endovascular Exclusion Using the Amplatzer Vascular Plug and Femorofemoral Crossover Graft

We report our initial experience using the Amplatzer Vascular Plug II (AVP2) in the treatment of a left common iliac aneurysm. Following investigation by computerized tomographic angiography and catheter angiography, a 79-year-old man was found to have a markedly tortuous iliac system, with a left common iliac artery aneurysm that measured 48 mm in maximal diameter. Due to the patient's age and comorbidities the surgical opinion was that conventional open repair was not suitable. However, due to the tortuous nature of the aneurysm and iliac vessels, standard endovascular repair, using either a bifurcated or an aorto-uni-iliac stent graft, was also not possible. A combined approach was used by embolizing the ipsilateral internal iliac artery using coils and excluding the aneurysm using two AVP2 occlusion devices, followed by femorofemoral crossover grafting. Total aneurysm occlusion was achieved using this method and this allowed the patient to have a much less invasive surgical procedure than with conventional open repair of common iliac aneurysms, thus avoiding potential comorbidity and mortality.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Endovascular Treatment of Ruptured Abdominal Aortic Aneurysm with Aortocaval Fistula

Aortocaval fistula (ACF) is a rare complication of abdominal aortic aneurysm (AAA). We report the endovascular repair of an AAA rupture into the inferior vena cava. A 78-year-old woman was admitted to our hospital for acute hypotension. She presented with a pulsatile abdominal mass and became rapidly anuric. Abdominal computed tomography (CT) showed an AAA rupture into the inferior vena cava. The features of the AAA made it suitable for endovascular repair. To prevent pulmonary embolism caused by the presence of sac thrombosis near the vena cava lumen, a temporary vena cava filter was deployed before the procedure. A bifurcated stent-graft was placed with the patient under local anaesthesia, and the AAA was successfully treated. A transient type II endoleak was detected on CT 3 days after endograft placement. At routine follow-up 6 and 12 months after the procedure, the patient was in good clinical condition, and the type II endoleak had sealed completely. Endovascular treatment offers an attractive therapeutic alternative to open repair in case of ACF; however, only small numbers of patients have been treated, and long-term follow-up interval is lacking.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Endovascular Treatment of Complications of Femoral Arterial Access

Endovascular repair of femoral arterial access complications is nowadays the treatment of choice in a group of patients who cannot tolerate vascular reconstruction and bleeding due to advanced cardiovascular disease. Endovascular procedures can be performed under local anesthesia, are well tolerated by the patient, and are associated with a short hospitalization time. Ninitinol stent technology allows for safe stent and stent-graft extension at the common femoral artery (CFA) level, due to increased resistance to external compression and bending stress. Active pelvic bleeding can be insidious, and prompt placement of a stent-graft at the site of leakage is a lifesaving procedure. Percutaneous thrombin injection under US guidance is the treatment of choice for femoral pseudoaneurysms (PAs); this can theoretically be safer with simultaneous balloon occlusion across the entry site of a PA without a neck or with a short and wide neck. In a few cases with thrombin failure due to a large arterial defect or accompanying arteriovenous fistula (AVF), a stent-graft can be deployed. The vast majority of catheter-induced AVFs can be treated effectively with stent-graft implantation even if they are located very close to the femoral bifurcation. Obstructive dissection flaps localized in the CFA are usually treated with prolonged balloon inflation; however, in more extensive dissections involving iliac arteries, self-expanding stents should be deployed. Iliofemoral thrombosis can be treated effectively with catheter-directed thrombolysis (CDT) followed by prolonged balloon inflation or stent placement. Balloon angioplasty and CDT can occasionally be used to treat stenoses and occlusions complicating the use of percutaneous closure devices.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Are Carotid Stent Fractures Clinically Significant?

Purpose: Late stent fatigue is a known complication after carotid artery stenting (CAS) for cervical carotid occlusive disease. The purpose of this study was to determine the prevalence and clinical significance of carotid stent fractures. Materials and Methods: A single-center retrospective review of 253 carotid bifurcation lesions treated with CAS and mechanical embolic protection from April 2001 to December 2009 was performed. Stent integrity was analyzed by two independent observers using multiplanar cervical plain radiographs with fractures classified into the following types: type I = single strut fracture; type II = multiple strut fractures; type III = transverse fracture; and type IV = transverse fracture with dislocation. Mean follow-up was 32 months. Results: Follow-up imaging was completed on 106 self-expanding nitinol stents (26 closed-cell and 80 open-cell stents). Eight fractures (7.5%) were detected (type I n = 1, type II n = 6, and type III n = 1). Seven fractures were found in open-cell stents (Precise n = 3, ViVEXX n = 2, and Acculink n = 2), and 1 fracture was found in a closed-cell stent (Xact n = 1) (p = 0.67). Only a previous history of external beam neck irradiation was associated with fractures (p = 0.048). No associated clinical sequelae were observed among the patients with fractures, and only 1 patient had an associated significant restenosis ({>=}80%) requiring reintervention. Conclusions: Late stent fatigue after CAS is an uncommon event and rarely clinically relevant. Although cell design does not appear to influence the occurrence of fractures, lesion characteristics may be associated risk factors.

62 RADIOLOGY AND NUCLEAR MEDICINE↗