Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “BERYLLIUM”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 883 records · Page 49

Forward production of charged pions with incident protons on nuclear targets at the CERN Proton Synchrotron

Measurements of the double-differential {pi}{sup {+-}} production cross section in the range of momentum 0.5{<=}p{<=}8.0 GeV/c and angle 0.025{<=}{theta}{<=}0.25 rad in collisions of protons on beryllium, carbon, nitrogen, oxygen, aluminum, copper, tin, tantalum, and lead are presented. The data were taken with the large-acceptance HAdRon Production (HARP) detector in the T9 beamline of the CERN Proton Synchrotron. Incident particles were identified by an elaborate system of beam detectors. Thin targets of 5% of a nuclear interaction length were used. The tracking and identification of the produced particles were performed using the forward system of the HARP experiment. Results are obtained for the double-differential cross sections d{sup 2}{sigma}/dp d{omega} mainly at four incident proton beam momenta (3, 5, 8, and 12 GeV/c). Measurements are compared with the GEANT4 and MARS Monte Carlo generators. A global parametrization is provided as an approximation of all the collected datasets, which can serve as a tool for quick yield estimates.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

{beta}{sup -}-delayed spectroscopy of neutron-rich tantalum nuclei: Shape evolution in neutron-rich tungsten isotopes

The low-lying structure of {sup 188,190,192}W has been studied following {beta} decays of the neutron-rich mother nuclei {sup 188,190,192}Ta produced following the projectile fragmentation of a 1-GeV-per-nucleon {sup 208}Pb primary beam on a natural beryllium target at the GSI Fragment Separator. The {beta}-decay half-lives of {sup 188}Ta, {sup 190}Ta, and {sup 192}Ta have been measured, with {gamma}-ray decays of low-lying states in their respective W daughter nuclei, using heavy-ion {beta}-{gamma} correlations and a position-sensitive silicon detector setup. The data provide information on the low-lying excited states in {sup 188}W, {sup 190}W, and {sup 192}W, which highlight a change in nuclear shape at {sup 190}W compared with that of lighter W isotopes. This evolution of ground-state structure along the W isotopic chain is discussed as evidence for a possible proton subshell effect for the A{approx}190 region and is consistent with maximization of the {gamma}-softness of the nuclear potential around N{approx}116.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Large-angle production of charged pions with incident pion beams on nuclear targets

Measurements of the double-differential {pi}{sup {+-}} production cross section in the range of momentum 100{<=}p{<=}800 MeV/c and angle 0.35{<=}{theta}{<=}2.15 rad using {pi}{sup {+-}} beams incident on beryllium, aluminum, carbon, copper, tin, tantalum, and lead targets are presented. The data were taken with the large-acceptance hadron production (HARP) detector in the T9 beam line of the CERN Proton Synchrotron. The secondary pions were produced by beams in a momentum range from 3 to 12.9GeV/c hitting a solid target with a thickness of 5% of a nuclear interaction length. The tracking and identification of the produced particles was performed using a small-radius cylindrical time projection chamber placed inside a solenoidal magnet. Incident particles were identified by an elaborate system of beam detectors. Results are obtained for the double-differential cross sections d{sup 2}{sigma}/dp d{theta} at six incident-beam momenta. Data at 3,5,8, and 12GeV/c are available for all targets, while additional data at 8.9 and 12.9GeV/c were taken in positive particle beams on Be and Al targets, respectively. The measurements are compared with several generators of GEANT4 and the MARS Monte Carlo simulation.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Measurements of forward proton production with incident protons and charged pions on nuclear targets at the CERN Proton Synchrotron

Measurements of the double-differential proton production cross-section d{sup 2{sigma}}/dpd{Omega} in the range of momentum 0.5 GeV/c{<=}p<8.0 GeV/c and angle 0.05 rad{<=}{theta}<0.25 rad in collisions of charged pions and protons on beryllium, carbon, aluminium, copper, tin, tantalum, and lead are presented. The data were taken with the large acceptance HARP detector in the T9 beam line of the CERN Proton Synchrotron. Incident particles were identified by an elaborate system of beam detectors and impinged on a target of 5% of a nuclear interaction length. The tracking and identification of the produced particles was performed using the forward spectrometer of the HARP experiment. Results are obtained for the double-differential cross-sections mainly at four incident beam momenta (3,5,8, and 12 GeV/c). Measurements are compared with predictions of the geant4 and mars Monte Carlo generators.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Neutrino flux prediction at MiniBooNE

The booster neutrino experiment (MiniBooNE) searches for {nu}{sub {mu}}{yields}{nu}{sub e} oscillations using the O(1 GeV) neutrino beam produced by the booster synchrotron at the Fermi National Accelerator Laboratory). The booster delivers protons with 8 GeV kinetic energy (8.89 GeV/c momentum) to a beryllium target, producing neutrinos from the decay of secondary particles in the beam line. We describe the Monte Carlo simulation methods used to estimate the flux of neutrinos from the beam line incident on the MiniBooNE detector for both polarities of the focusing horn. The simulation uses the Geant4 framework for propagating particles, accounting for electromagnetic processes and hadronic interactions in the beam line materials, as well as the decay of particles. The absolute double differential cross sections of pion and kaon production in the simulation have been tuned to match external measurements, as have the hadronic cross sections for nucleons and pions. The statistical precision of the flux predictions is enhanced through reweighting and resampling techniques. Systematic errors in the flux estimation have been determined by varying parameters within their uncertainties, accounting for correlations where appropriate.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

New nuclear physics for big bang nucleosynthesis

We discuss nuclear reactions which could play a role in big bang nucleosynthesis. Most of these reactions involve lithium and beryllium isotopes and the rates for some of these have not previously been included in BBN calculations. Few of these reactions are well studied in the laboratory. We also discuss novel effects in these reactions, including thermal population of nuclear target states, resonant enhancement, and nonthermal neutron reaction products. We perform sensitivity studies which show that even given considerable nuclear physics uncertainties, most of these nuclear reactions have minimal leverage on the standard BBN abundance yields of {sup 6}Li and {sup 7}Li. Although a few have the potential to alter the yields significantly, we argue that this is unlikely.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Measurement of K + production cross section by 8 GeV protons using high energy neutrino interactions in the SciBooNE detector

The SciBooNE Collaboration reports K + production cross section and rate measurements using high energy daughter muon neutrino scattering data off the SciBar polystyrene (C 8 H 8 ) target in the SciBooNE detector. The K + mesons are produced by 8 GeV protons striking a beryllium target in Fermilab Booster Neutrino Beam line (BNB). Using observed neutrino and antineutrino events in SciBooNE, we measure d 2 σ/dpdΩ = (5.34 ±0.76) mb/(GeV/c x sr) for p + Be =K + + X at mean K + energy of 3.9 GeV and angle (with respect to the proton beam direction) of 3.7 degrees, corresponding to the selected K + sample. Compared to Monte Carlo predictions using previous higher energy K + production measurements, this measurement, which uses the NUANCE neutrino interaction generator, is consistent with a normalization factor of 0.85 ± 0.12. This agreement is evidence that the extrapolation of the higher energy K + measurements to an 8 GeV beam energy using Feynman scaling is valid. This measurement reduces the error on the K + production cross section from 40% to 14%.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Dominance of the Breit Interaction in the X-Ray Emission of Highly Charged Ions Following Dielectronic Recombination

The Breit interaction typically appears as a--more or less small--correction to the Coulomb repulsion acting among the electrons. We here propose two x-ray measurements on the angular distribution and linear polarization of the 1s2s{sup 2}2p{sub 1/2} J=1->1s{sup 2}2s{sup 2} J=0 electric-dipole radiation of high-Z, beryllium-like ions, following the resonant electron capture into initially lithium-like ions, for which the Breit interaction strongly dominates the Coulomb repulsion and leads to a qualitative change in the expected x-ray emission pattern. The proposed measurements are feasible with present-day x-ray detectors and may serve a stringent test on relativistic corrections to the electron-electron interaction in the presence of strong fields.

74 ATOMIC AND MOLECULAR PHYSICS↗

Micro-focused MHz pink beam for time-resolved X-ray emission spectroscopy

The full radiation from the first harmonic of a synchrotron undulator (between 5 and 12 keV) at the Advanced Photon Source is microfocused using a stack of beryllium compound refractive lenses onto a fast-moving liquid jet and overlapped with a high-repetition-rate optical laser. This micro-focused geometry is used to perform efficient nonresonant X-ray emission spectroscopy on transient species using a dispersive spectrometer geometry. The overall usable flux achieved on target is above 10 15 photons s -1 at 8 keV, enabling photoexcited systems in the liquid phase to be tracked with time resolutions from tens of picoseconds to microseconds, and using the full emission spectrum, including the weak valence-to-core signal that is sensitive to chemically relevant electronic properties.

47 OTHER INSTRUMENTATION↗

Preliminary waste management plan of European spallation

The European Spallation Source (ESS) is the European common effort in designing and building a next generation large-scale user facility for studies of the structure and dynamics of materials. The proposed schematic layout of the ESS facility is based on a linear driver (linac) directing the proton beam (5 MW of 2.5 GeV) of 2.8 ms long pulses with a 20 Hz on a tungsten target where neutrons are produced via spallation reactions. Further the neutrons will be moderated to thermal and sub-thermal energies in a couple of moderators placed around the target. The moderators feed 22 beamlines guiding the neutrons to the scattering instruments, mainly for neutron scattering research, as has been previously mentioned. The objective of this work is to develop a waste management plan for ESS facility. In this respect two important aspects are analyzed. First the present status of the problem is outlined as follow. Estimate types and quantities of waste that the ESS project will generate at different stages: commission, operation, decommissioning were derived using: i) precise Monte Carlo calculations ii) scaling the activity from the operation experience of the existing spallation source installations for waste such it is difficult to predict level of activation or for components of the facility in stage of the preconceptual model. Associated waste treatment/conditioning options and final disposal route were further analyzed in order to define the waste type and packet descriptions in agreement with Swedish regulations and policy. It was found that the compilation of completely new waste type descriptions for qualification of the ESS waste for disposal will be necessary. Particular attention was devoted to 'problematic waste' as Beryllium reflector, C-14 from graphite used as core zone of the beam-dump and collimators or waste arising from the purification systems of both Helium and water cooling circuits. Management of waste on ESS site: collection/segregation systems, characterization system, storage options, is also described. In the second step, the acquired information is used for planning and implementing actions involving all participants (ESS, treatment facility operator, disposal operator, regulatory body and other authorized authorities). (authors)

07 ISOTOPE AND RADIATION SOURCES↗

Using collective x-ray Thomson scattering to measure temperature and density of warm dense matter

Collective x-ray Thomson scattering allows measuring plasmons, i.e electron plasma oscillations (Langmuir waves). This is manifest in the appearance of spectrally up- and down-shifted spectral features in addition to the Rayleigh signal. The ratio of the up- and down-shifted signals is directly related to detailed balance, allowing to determine the plasma temperature from first principles. The spectral shift of the plasmon signals is sensitive to temperature and electron density. We discuss the experimental considerations that have to be fulfilled to observe plasmon signals with x-ray Thomson scattering. As an example, we describe an experiment that used the Cl Ly-{alpha} x-ray line at 2.96 keV to measure collective Thomson scattering from solid beryllium, isochorically heated to 18 eV. Since temperature measurement based on detailed balance is based on first principles, this method is important to validate models that, for example, calculate the static ion-ion structure factor S{sub ii}(k).

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Low-Z target optimization for spatial resolution improvement in megavoltage imaging

Purpose: Recently, several authors have shown contrast improvements in megavoltage portal imaging and cone-beam computed tomography using low atomic number (Z) targets. This work compliments previous studies by investigating the effects of varying different beam production parameters including target atomic number, target thickness, and incident electron energy on spatial resolution. Methods: Target materials of beryllium, aluminum, and tungsten were investigated over a range of thicknesses between 10% and 100% of the continuous slowing down approximation range of electrons. Incident electron kinetic energies of 4.5 and 7.0 MeV were used, in conjunction with custom targets installed above the carousel of a modern radiotherapy linear accelerator. Monte Carlo simulations of the accelerator were constructed and compared to the experimental results. Results: The results showed that thinner targets, as well higher incident electron energies, generally produce more favorable modulation transfer function (MTF) curves. Due to an MTF dependence of the detector system on the photon energy, the experimental results showed that low-Z targets produced superior MTF curves. Simulations showed 14.5% and 21.5% increases in f{sub 50} for the 7.0 and 4.5 MeV targets (Al; 60%R{sub %CSDA}), respectively, when moved from the carousel to the location of the clinical target. f{sub 50} values for the custom targets were compared to the clinical 6 MV beam and were found to be between 10.4% lower (4.5 MeV/W) and 15.5% higher (7.0 MeV/Be). Conclusions: Integration of low-Z external targets into the treatment head of a medical linear was achieved with only minor modifications. It was shown that reasonably high resolution images on par or better than those acquired with the clinical 6 MV beam can be achieved using external low-Z targets.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fast IMRT with narrow high energy scanned photon beams

Purpose: Since the first publications on intensity modulated radiation therapy (IMRT) in the early 1980s almost all efforts have been focused on fairly time consuming dynamic or segmental multileaf collimation. With narrow fast scanned photon beams, the flexibility and accuracy in beam shaping increases, not least in combination with fast penumbra trimming multileaf collimators. Previously, experiments have been performed with full range targets, generating a broad bremsstrahlung beam, in combination with multileaf collimators or material compensators. In the present publication, the first measurements with fast narrow high energy (50 MV) scanned photon beams are presented indicating an interesting performance increase even though some of the hardware used were suboptimal. Methods: Inverse therapy planning was used to calculate optimal scanning patterns to generate dose distributions with interesting properties for fast IMRT. To fully utilize the dose distributional advantages with scanned beams, it is necessary to use narrow high energy beams from a thin bremsstrahlung target and a powerful purging magnet capable of deflecting the transmitted electron beam away from the generated photons onto a dedicated electron collector. During the present measurements the scanning system, purging magnet, and electron collimator in the treatment head of the MM50 racetrack accelerator was used with 3-6 mm thick bremsstrahlung targets of beryllium. The dose distributions were measured with diodes in water and with EDR2 film in PMMA. Monte Carlo simulations with geant4 were used to study the influence of the electrons transmitted through the target on the photon pencil beam kernel. Results: The full width at half-maximum (FWHM) of the scanned photon beam was 34 mm measured at isocenter, below 9.5 cm of water, 1 m from the 3 mm Be bremsstrahlung target. To generate a homogeneous dose distribution in a 10 x 10 cm{sup 2} field, the authors used a spot matrix of 100 equal intensity beam spots resulting in a uniformity of collimated 80%-20% penumbra of 9 mm at a primary electron energy of 50 MeV. For the more complex cardioid shaped dose distribution, they used 270 spots, which at a pulse repetition frequency of 200 Hz is completed every 1.36 s. Conclusions: The present measurements indicate that the use of narrow scanned photon beams is a flexible and fast method to deliver advanced intensity modulated beams. Fast scanned photon IMRT should, therefore, be a very interesting modality in the delivery of biologically optimized radiation therapy with the possibility for in vivo treatment verification with PET-CT imaging.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Evaluation of a real-time BeO ceramic fiber-coupled luminescence dosimetry system for dose verification of high dose rate brachytherapy

Purpose: The authors evaluate the capability of a beryllium oxide (BeO) ceramic fiber-coupled luminescence dosimeter, named radioluminescence/optically stimulated luminescence (RL/OSL) BeO FOD, for dosimetric verification of high dose rate (HDR) treatments. The RL/OSL BeO FOD is capable of RL and OSL measurements. Methods: The RL/OSL BeO FOD is able to be inserted in 6F proguide needles, used in interstitial HDR treatments. Using a custom built Perspex phantom, 6F proguide needles could be submerged in a water tank at 1 cm separations from each other. A second background fiber was required to correct for the stem effect. The stem effect, dose linearity, reproducibility, depth-dose curves, and angular and temperature dependency of the RL/OSL BeO FOD were characterised using an Ir-192 source. The RL/OSL BeO FOD was also applied to the commissioning of a 10 mm horizontal Leipzig applicator. Results: Both the RL and OSL were found to be reproducible and their percentage depth-dose curves to be in good agreement with those predicted via TG-43. A combined uncertainty of 7.9% and 10.1% (k = 1) was estimated for the RL and OSL, respectively. For the 10 mm horizontal Leipzig applicator, measured percentage depth doses were within 5% agreement of the published reference calculations. The output at the 3 mm prescription depth for a 1 Gy delivery was verified to be 0.99 ± 0.08 Gy and 1.01 ± 0.10 Gy by the RL and OSL, respectively. Conclusions: The use of the second background fiber under the current setup means that the two fibers cannot fit into a single 6F needle. Hence, use of the RL is currently not adequate for the purpose of in vivo brachytherapy dosimetry. While not real-time, the OSL is shown to be adequate for in vivo brachytherapy dosimetry.

60 APPLIED LIFE SCIENCES↗

Crystallization of beryllian indialite from its own melt under oxidizing conditions

It is established that beryllian indialite (ideal formula Mg{sub 2}BeAl{sub 2}Si{sub 6}O{sub 18}) is formed spontaneously under oxidizing conditions in a wide range of relatively high cooling rates at small overheatings of its own melt and short overheating times. The significant difference in the growth rates of the prism and pinacoid faces of beryllian indialite from its own melt (0.08 and 0.40 mm/h, respectively) obtained by the Steber method is explained by the fact that the prism grows according to the tangential mechanism, while the pinacoid grows in the normal way. The face effect in these crystals manifests itself in the enrichment of the prism with beryllium and silicon as opposed to pinacoid.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Spectrometer of Synchrotron Radiation Based on Diffraction Focusing a Divergent Beam Formed by a Compound Refractive Lens

The results of the first experimental realization of a spectrometer based on the effect of diffraction focusing of X rays by a flat single crystal are discussed. A secondary X-ray source with a relatively high angular divergence and small sizes was formed at the focus of a compound refractive lens having 50 beryllium biconcave elements with a curvature radius of 50 μm. The silicon spectrometer crystal was cut in the form of a wedge of variable thickness, oriented perpendicular to the diffraction plane. The reflection 111 was used for energies of 8.3 and 12 keV. To simulate the experiment, a computer program was developed, which takes into account accurately and for the first time the focusing of radiation by the lens and its subsequent diffraction in the crystal. A calculated curve for a monochromatic beam has made it possible to determine the monochromator spectrum with high resolution from experimental data for a polychromatic beam. It is shown that monochromator resolution increases with an increase in the distance from the compound refractive lens to the crystal.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Electron Energy Conversion to EUV Radiation in the K{sub α} Line of Be in the “Shooting Through” Geometry

A model is presented and the interaction of accelerated electrons with atoms in a thin film “shooting through” Be target is theoretically described. The algorithm is based on the Monte Carlo simulation of the electron motion in the target accompanied by energy losses in elastic and inelastic interactions. The conversion of the electron energy to the radiation energy in the 11.4-nm K{sub α} line of Be and the emission spectrum are calculated. The maximum conversion efficiency to the solid angle 4π CE = 3.0 × 10{sup –4} is achieved for the electron energy E{sub e} = 2.0 keV and a 40-nm-thick freely suspended beryllium film. 200-nm and 400-nm-thick films were experimentally investigated. The maximum conversion efficiency to the solid angle 4π for a 200‑nm-thick film and the electron energy E{sub e} = 2.75 keV was CE{sub exp} = 9.2 × 10{sup –5}, whereas the calculated value was CE{sub calc} = 2.5 × 10{sup –4}. The observed discrepancy between the theory and experiment is explained in the paper.

74 ATOMIC AND MOLECULAR PHYSICS↗

On the question of the magnitude of day-night asymmetry for solar neutrinos

The effect of flavor day-night asymmetry is considered for solar neutrinos of energy about 1 MeV under the assumption that the electron-density distribution within the Earth is approximately piecewise continuous on the scale of the neutrino-oscillation length. In this approximation, the resulting asymmetry factor for beryllium neutrinos does not depend on the structure of the inner Earth's layers or on the properties of the detector used. Its numerical estimate is on the order of -4 Multiplication-Sign 10{sup -4}, which is far beyond the reach of present-day experiments.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗