Dynamic Strain Aging in Additively Manufactured Steel at Elevated Temperatures.
Abstract not provided.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Abstract not provided.
An apparatus for making in-situ electrical measurements of a sample while the sample is subjected to a temperature gradient between a first side of the sample and a second side of the sample. The apparatus comprises a first heater and a second heater that are positioned in contact with the first side of the sample and the second side of the sample, respectively. The first heater and the second heater comprise respective faces that each have electrical contacts embedded therein. Electrical measurements pertaining to the sample can be made by way of the electrical contacts embedded in the faces. A temperature at either side of the sample can be monitored by way of thermocouples positioned inside the heaters in proximity to the faces of the heaters.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Abstract not provided.
Explore the source record for details and available documents.
Cyberbiosecurity, the aspect of biosecurity involving the digital representation of biological data, had already been emerging as a matter of public concern even prior to the onset of the COVID-19 pandemic. Key issues of concern include, among others, the privacy of patient data, the security of public health databases, the integrity of diagnostic test data, the integrity of public biological databases, the security implications of automated laboratory systems and the security of proprietary biological engineering advances. With the onset of the COVID-19 pandemic, and the importance of digital resources in combatting it, concern about the potential for cyber attacks by state-based or non-state actors has been elevated. To illuminate the challenges, we focus on the cyber vulnerabilities that need to be addressed in public health activities such as disease surveillance and outbreak management. In particular, we examine cyber issues raised by the accelerated pace of development for COVID mitigations, treatments, and vaccines.
Abstract not provided.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Abstract not provided.
Explore the source record for details and available documents.
Abstract not provided.
Vacuum insulation panels have very low thermal conductivities compared to conventional insulation materials. The reduction of the core pressure significantly lowers gas phase conduction and overall thermal conductivity. As a consequence, increases in gas pressure can significantly increase thermal conductivity of the VIP. In addition, the thermal conductivity of the core is sensitive to moisture content. For vacuum insulation panels with fumed silica cores, work shows that the measured thermal conductivity increases by 0.5 x 10-3 W/mK per mass percent increase in water content [1]. This is significant since the thermal conductivity of vacuum insulation panels with fumed silica cores is in the range of 0.004 W/mK. This work investigates the long-term behavior of vacuum insulation panels comprised of fumed silica cores with polymer (ethylene vinyl alcohol) and metalized (aluminized) barrier films exposed to different exposure conditions: ambient conditions; exterior conditions in a mixed humid climate; and 24oC and 80 percent relative humidity. Results show that the increase in thermal conductivity is more pronounced for vacuum insulation panels made using polymer barrier films compared to the same panel protected by a metalized film. The increase is more pronounced when exposed to high relative humidity, 80 percent. After almost two years exposure, the decrease in thermal conductivity for vacuum insulation panels protected by a metalized barrier films are between 4 and 11 percent depending on exposure condition. The smallest decrease is for ambient conditions where the largest decrease is for exposure to 80 percent relative humidity. Similar behavior was observed for panels protected using polymer films, except the decrease in thermal conductivity was significantly higher, between approximately 20 and 60 percent, in the same order as for panels protected by metalized films. Measurements are ongoing with an attempt to develop a better relationship between these types of tests and vacuum insulation panel service life.
Explore the source record for details and available documents.
Ventilation is the first line of defense against airborne hazards produced during research activities in laboratories. A vital component to maintaining healthy, safe, indoor air quality, laboratory ventilation systems are often victim to ineffective operation, posing a risk to an organization's most important asset - the researchers. Furthermore, system inefficiencies can lead to up to 50% wasted energy. By providing a framework to improve the safety and energy efficiency through optimized ventilation and operations, the Smart Labs Toolkit guides laboratory stakeholders through a straight-forward, holistic approach to achieving a dynamic Smart Labs program. A Smart Labs program employs a combination of physical, administrative, and management techniques to plan, assess, optimize, and manage high-performance laboratories. Grounded in the Smart Labs methodology, the National Renewable Energy Laboratory (NREL) implemented a successful Smart Labs program to oversee the design, construction, maintenance, and operations of its laboratories. To accomplish this effort, NREL's key stakeholders created an internal partnership to align NREL's existing laboratories with Smart Labs principles and solidify organizational roles for the safe and efficient operation of laboratory assets. The program provides the groundwork for decarbonization strategies centered around building operation. This paper outlines best practices employed by NREL to develop a cross-cutting Smart Labs team, garner managerial support, and effectively communicate of goals around safety and energy. Strategies include specific Smart Labs best practices, such as implementing a Laboratory Ventilation Risk Assessment - a systematic process for identifying risk due to airborne hazards and informing dynamic, demand-based ventilation to optimize safety and efficiency.
Explore the source record for details and available documents.
Explore the source record for details and available documents.