Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “AMPLIFIER DESIGN”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 883 records · Page 49

A Universally Primed-Polymerase Chain Reaction (UP-PCR) Marker to Discriminate Clonostachys rosea ACM941 from Related Strains

Clonostachys rosea strain ACM941 is an effective biocontrol agent against several crop diseases including Fusarium head blight. In anticipation of its increased relevance going forward, the development of a reliable DNA-based molecular marker to track it is essential. Universally primed-PCR (UP-PCR) has been used successfully to differentiate other C. rosea strains. Herein, the development of a UP-PCR marker for ACM941 is described. A combination of two primers (AS15 and L45) produced a ~450 bp fragment that was unique to ACM941 compared to other commercial biocontrol agents. Primers subsequently designed based on the obtained fragment also produced a similarly unique band from ACM941 alone. BLAST analysis of the amplified sequence did not yield any homologous sequence in available online databases or within the closely related C. rosea IK726 and CBS125111 strains’ genomes. The specificity of this marker for ACM941 was validated against ten additional C. rosea strains isolated from Canada, with ACM941 producing the brightest band. Taken together, these results imply that the UP-PCR primers AS15 and L45 and the amplified fragment can be used to detect and monitor the ACM941 strain after its release into the environment.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Prototype data terminal: Multiplexer/demultiplexer

The design and operation of a quad redundant data terminal and a multiplexer/demultiplexer (MDU) design are described. The most unique feature is the design of the quad redundant data terminal. This is one of the few designs where the unit is fail/op, fail/op, fail/safe. Laboratory tests confirm that the unit will operate satisfactorily with the failure of three out of four channels. Although the design utilizes state-of-the-art technology. The waveform error checks, the voting techniques, and the parity bit checks are believed to be used in unique configurations. Correct word selection routines are also novel, if not unique. The MDU design, while not redundant, utilizes, the latest state-of-the-art advantages of light couplers and integrated circuit amplifiers.

Leck, D. E.↗

Development of FIR arrays with integrating amplifiers

The development of optimized photoconductor arrays suitable for far infrared space astronomical applications are described. Although the primary impetus is the production of a 16 by 16 element Ge:Ga demonstration array for SIRTF, the extension of this technology to Large Deployable Reflector (LDR) is considered. The optimization of Ge:Ga and Ge:Be photoconductor materials is discussed. In collaboration with Lawrence Berkeley Laboratory, measurements of FIR photoconductors with quantum efficiencies greater than 20 percent at 100 micrometers, and dark currents below 300 electrons/s are presented. Integrating J-FET amplifier technology is discussed. The current generation of integrating amplifiers has a demonstrated read noise of less than 20 electrons for an integration time of 100 s. The design is shown for a stackable 16 x n Ge:Ga array that utilizes a 16-channel monolithic version of the J-FET integrator. A part of the design is the use of a thin, thermally insulating substrate that allows the electronics to operate at the optimum temperature of 50 K while maintaining thermal and optical isolation from the detectors at 2 K. The power dissipation for the array is less than 16 mW. The array design may particularly be applicable to high resolution imaging spectrometers for LDR.

Young, Erick T.↗

Stabilised electromagnetic levitation at 2-13 MHz

SEL, the Stabilised Electromagnetic Levitator, has been developed to exploit the unique design opportunities available in containerless microgravity experiments. Efficiency and versatility are obtained with multiple coils driven by individual broadband amplifiers whose phase and frequency are controlled. The heating and positioning fields are decoupled. Specimen translation, spin, and for liquids, shape may be adjusted. An open coil structure provides access for optical and diagnostic probes. Results of experiments with a prototype device are discussed. Levitating and heating materials on earth were demonstrated at frequencies up to 13 MHz.

Danley, T. J.↗

A conventional point of view on active magnetic bearings

Active magnetic bearings used in rotating machinery should be designed as locally controlled, independent devices similar to other types of bearings. The functions of control electronics and power amplifiers can be simply and explicitly related to general bearing properties such as load capacity, stiffness, and damping. The dynamics of a rotor and its supporting active magnetic bearings are analyzed in a modified conventional method with an extended state vector containing the bearing state variables.

Chen, H. Ming↗

Narrow Angle Wide Spectral Range Radiometer Design FEANICS/REEFS Radiometer Design Report

A critical measurement for the Radiative Enhancement Effects on Flame Spread (REEFS) microgravity combustion experiment is the net radiative flux emitted from the gases and from the solid fuel bed. These quantities are measured using a set of narrow angle, wide spectral range radiometers. The radiometers are required to have an angular field of view of 1.2 degrees and measure over the spectral range of 0.6 to 30 microns, which presents a challenging design effort. This report details the design of this radiometer system including field of view, radiometer response, radiometric calculations, temperature effects, error sources, baffling and amplifiers. This report presents some radiometer specific data but does not present any REEFS experiment data.

Camperchioli, William↗

Cassini Radio Science Experiments on Saturn and Titan Preserved Because of Lewis Analysis

The Cassini mission to Saturn is an international venture with participation from NASA, the European Space Agency, and the Italian Space Agency. The Cassini spacecraft was launched from Cape Canaveral in October 1997 and is scheduled to arrive at Saturn in July 2004. After arrival, the spacecraft will orbit Saturn about 60 times over a period of 4 years. During this time, the Cassini Radio Science Subsystem will be used to investigate the atmosphere and rings of Saturn and the atmosphere of its largest moon, Titan--which is larger than Mercury and is the only moon in our solar system with a dense atmosphere. A critical component in Cassini s Radio Science Subsystem is a traveling-wave tube (TWT) that was designed at the NASA Lewis Research Center and built by Hughes Electronic Dynamics Division (ref. 1). This TWT will amplify downlink microwave signals at a frequency of 32 GHz for the Deep Space Network and will be involved in a number of experiments. These include occultation experiments in which the microwave signal will be beamed through rings and atmospheres toward Earth. Researchers will analyze the received signals to determine the sizes and distributions of the particles in the rings and the structure and composition of the atmospheres. The Radio Science Subsystem also will also be used to more accurately determine the mass and size of Saturn and its moons, to investigate the solar corona, and to search for gravity waves from outside the solar system.

Wilson, Jeffrey D.↗

Direct-detection Free-space Laser Transceiver Test-bed

NASA Goddard Space Flight Center is developing a direct-detection free-space laser communications transceiver test bed. The laser transmitter is a master-oscillator power amplifier (MOPA) configuration using a 1060 nm wavelength laser-diode with a two-stage multi-watt Ytterbium fiber amplifier. Dual Mach-Zehnder electro-optic modulators provide an extinction ratio greater than 40 dB. The MOPA design delivered 10-W average power with low-duty-cycle PPM waveforms and achieved 1.7 kW peak power. We use pulse-position modulation format with a pseudo-noise code header to assist clock recovery and frame boundary identification. We are examining the use of low-density-parity-check (LDPC) codes for forward error correction. Our receiver uses an InGaAsP 1 mm diameter photocathode hybrid photomultiplier tube (HPMT) cooled with a thermo-electric cooler. The HPMT has 25% single-photon detection efficiency at 1064 nm wavelength with a dark count rate of 60,000/s at -22 degrees Celsius and a single-photon impulse response of 0.9 ns. We report on progress toward demonstrating a combined laser communications and ranging field experiment.

Krainak, Michael A.↗

Synthesis of Submillimeter Radiation for Spectroscopy

The frequency-multiplier submillimeter spectrometer (FMSS) is a laboratory apparatus for far-infrared molecular spectroscopy, embodying several advances over prior such apparatuses. The most innovative part of the FMSS is a source of monochromatic submillimeter- wavelength radiation that can be tuned over a wide frequency range, as needed for trace gas analyses and molecular- structure studies for which such apparatuses are typically used. The radiation source features a modular design and is built mostly from commercially available components. It includes a computer-controlled radio-frequency synthesizer, amplifiers, and frequency multipliers of a type heretofore used in local oscillators for heterodyne far-infrared receivers. In conjunction with the rest of the apparatus, this source makes it possible to perform measurements over large portions of the submillimeter-wavelength spectrum with resolution, accuracy, and sensitivity greater than those achievable in Fourier-transform infrared spectroscopy. In comparison with prior laboratory submillimeter- wavelength radiation sources, this source is much lighter in weight, less cumbersome, less power-hungry, and capable of sustained operation with less intervention by laboratory personnel. Also, unlike some prior submillimeter-wavelength sources, this source does not require a high-voltage power source. As shown in more detail in the figure, the radiation source includes a sweep frequency synthesizer connected to an external waveform generator, the output of which is used as a reference signal. The synthesizer is computer-controlled through a standard general-purpose interface bus (GPIB) and is operated in phase-locked continuous- wave mode for all measurements. The synthesizer output ranges in frequency from 11 to 18 GHz. For suppression of frequency spurs and harmonics, the output of the frequency synthesizer is fed through a tunable yttrium iron garnet (YIG) filter, which is swept in frequency simultaneously with the frequency synthesizer.

Maiwald, Frank↗

Near Infrared Cavity Ring-Down Spectroscopy for Isotopic Analyses of CH4 on Future Martian Surface Missions

A compact Near Infrared Continuous Wave Cavity Ring-Down Spectrometer (near-IR-cw-CRDS) was developed as a candidate for future planetary surface missions. The optical cavity was made of titanium with rugged quartz windows to protect the delicate super cavity from the harsh environmental changes that it would experience during space flight and a Martian surface mission. This design assured the long-term stability of the system. The system applied three distributed feedback laser diodes (DFB-LD), two of which were tuned to the absorption line peaks of (sup 12)CH4 and (sup 13)CH4 at 6046.954 inverse centimeters and 6049.121 inverse centimeters, respectively. The third laser was tuned to a spectral-lines-free region for measuring the baseline cavity loss. The multiple laser design compensated for typical baseline drift of a CRDS system and, thus, improved the overall precision. A semiconductor optical amplifier (SOA) was used instead of an Acousto-Optic Module (AOM) to initiate the cavity ring-down events. It maintained high acquisition rates such as AOM, but consumed less power. High data acquisition rates combined with improved long-term stability yielded precise isotopic measurements in this near-IR region even though the strongest CH4 absorption line in this region is 140 times weaker than that of the strongest mid-IR absorption band. The current system has a detection limit of 1.4 times 10( sup –12) inverse centimeters for (sup 13)CH4. This limit corresponds to approximately 7 parts per trillion volume of CH4 at 100 Torrs. With no further improvements the detection limit of our current near IR-cw-CRDS at an ambient Martian pressure of approximately 6 Torrs (8 millibars) would be 0.25 parts per billion volume for one 3.3 minute long analysis.

portable nir crds↗

Dual-mode oscillator for stress compensated cut resonator

Both parallel-type and serial-type dual-mode oscillators employing stress compensated cut resonators having various configurations are disclosed. Both classes of dual-mode oscillators employ multiple tank circuits to pass one frequency of the resonator and block the other frequency. The tank circuits isolate the operation of the two oscillator sub-circuits that form the dual-mode oscillator from one another. The dual-mode oscillators may be implemented with either bipolar or CMOS transistors. The parallel-type dual-mode oscillators employ inverters to provide gain. The serial-type dual-mode oscillators employ a two (or three) stage design including a follower circuit first stage and an inverting amplifier/limiter circuit second stage, with an optional intervening transimpedance amplifier stage.

Wessendorf, Kurt O.↗

A Proposed Fast Luminosity Feedback for the Super-B Accelerator

We present a possible design for a fast luminosity feedback for the SuperB Interaction Point (IP). The design is an extension of the fast luminosity feedback installed on the PEP-II accelerator. During the last two runs of PEP-II and BaBar (2007-2008), we had an improved luminosity feedback system that was able to maintain peak luminosity with faster correction speed than the previous system. The new system utilized fast dither coils on the High-Energy Beam (HEB) to independently dither the x position, the y position and the y angle at the IP, at roughly 100 Hz. The luminosity signal was then read out with three independent lock-in amplifiers. An overall correction was computed based on the lock-in signal strengths and beam corrections for position in x and y and in the y angle at the IP were simultaneously applied to the HEB. With the 100 times increase in luminosity for the SuperB design, we propose using a similar fast luminosity feedback that can operate at frequencies between DC and 1 kHz, high enough to follow any beam motion from the final focusing magnets.

43 PARTICLE ACCELERATORS↗

315mJ, 2-micrometers Double-Pulsed Coherent Differential Absorption Lidar Transmitter for Atmospheric CO2 Sensing

The design of a double pulsed, injection seeded, 2-micrometer compact coherent Differential absorption Lidar (DIAL) transmitter for CO2 sensing is presented. This system is hardened for ground and airborne applications. The design architecture includes three continuous wave lasers which provide controlled on and off line seeding, injection seeded power oscillator and a single amplifier operating in double pass configuration. As the derivative a coherent Doppler wind lidar, this instrument has the added benefit of providing wind information. The active laser material used for this application is a Ho: Tm:YLF crystal operates at the eye-safe wavelength. The 3-meter long folded ring resonator produces energy of 130-mJ (90/40) with a temporal pulse length around 220 nanoseconds and 530 nanosecond pulses for on and off lines respectively. The separation between the two pulses is on the order of 200 microseconds. The line width is in the order of 2.5MHz and the beam quality has an M(sup 2) of 1.1 times diffraction limited beam. A final output energy for a pair of both on and off pulses as high as 315 mJ (190/125) at a repetition rate of 10 Hz is achieved. The operating temperature is set around 20 C for the pump diode lasers and 10 C for the rod. Since the laser design has to meet high-energy as well as high beam quality requirements, close attention is paid to the laser head design to avoid thermal distortion in the rod. A side-pumped configuration is used and heat is removed uniformly by passing coolant through a tube slightly larger than the rod to reduce thermal gradient. This paper also discusses the advantage of using a long upper laser level life time laser crystal for DIAL application. In addition issues related to injection seeding with two different frequencies to achieve a transform limited line width will be presented.

Yu, Jirong↗

Design and validation of a high-voltage levitation circuit for electrostatic accelerometers

A simple high-voltage circuit with a voltage range of 0 to 900 V and an open-loop bandwidth of 11 kHz is realized by using an operational amplifier and a MOSFET combination. The circuit is used for the levitation of a test mass of 71 g, suspended below the top-electrodes with a gap distance of 57 μm, so that the performance of an electrostatic accelerometer can be tested on the ground. The translation noise of the accelerometer, limited by seismic noise, is about 4 × 10{sup −8} m/s{sup 2}/Hz{sup 1/2} at 0.1 Hz, while the high-voltage coupling noise is one-order of magnitude lower.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Zeptocalorimetry

Here we present the development of a Zeptocalorimeter. The motivation for designing and implementing such a device is driven, ultimately, by its anticipated exceptional sensitivity (10-21 J/K, at 2K). Such a device would be highly valuable in detecting minute quantities of mass for threat detection, studying fundamental phonon physics, and detecting energetic dissipation events at the attojoule level. To date, the most sensitive calorimeter demonstrated in the literature at 2K has been developed by the Roukes group at Caltech, where they achieved an addendum heat capacity of 10 -15 J/K with a 1/1000 sensitivity to external stimuli. To obtain such a low value of heat capacity requires a very small thermal mass, and thus, one of the greatest challenges in this project is the fabrication of this device, which requires numerous precision nanofabrication techniques. Furthermore, the heat capacity measurement of this device, as performed from room temperature to cryogenic temperatures, is equally challenging, as the transient signals used to determine the platform's thermal time constant require careful attention to the mitigation of feedthrough capacitance and delicate amplifier offsets. In this report we describe in detail the fabrication process flow for developing the calorimeter, including the layout and device design for obtaining a single lumped RC thermal resistance and capacitance, so that the device can be used for quantitative measurements of nanoscale materials with a suitable thermal link. The measurement method and experimental setup are also given, where we explain the heater and thermometer calibration methods, the thermal resistance measurements, the transient measurements, and lastly the cryogenic setup with intermediate frequency cabling and the thermal sinking of those lines.

47 OTHER INSTRUMENTATION↗

Inflatable Antenna for CubeSat: Extension of the Previously Developed S-Band Design to the X-Band

The inflatable antenna for CubeSat is a 1 meter antenna reflector designed with one side reflective Mylar, another side clear Mylar with a patch antenna at the focus. The development of this technology responds to the increasing need for more capable communication systems to allow CubeSats to operate autonomously in interplanetary missions. An initial version of the antenna for the S-Band was developed and tested in both anechoic chamber and vacuum chamber. Recent developments in transceivers and amplifiers for CubeSat at X-band motivated the extension from the S-Band to the X-Band. This paper describes the process of extending the design of the antenna to the X-Band focusing on patch antenna redesign, new manufacturing challenges and initial results of experimental tests.

Babuscia, Alessandra↗

Low-Power SOI CMOS Transceiver

The work aims at developing a low-power Silicon on Insulator Complementary Metal Oxide Semiconductor (SOI CMOS) Transceiver for deep-space communications. RF Receiver must accomplish the following tasks: (a) Select the desired radio channel and reject other radio signals, (b) Amplify the desired radio signal and translate them back to baseband, and (c) Detect and decode the information with Low BER. In order to minimize cost and achieve high level of integration, receiver architecture should use least number of external filters and passive components. It should also consume least amount of power to minimize battery cost, size, and weight. One of the most stringent requirements for deep-space communication is the low-power operation. Our study identified that two candidate architectures listed in the following meet these requirements: (1) Low-IF receiver, (2) Sub-sampling receiver. The low-IF receiver uses minimum number of external components. Compared to Zero-IF (Direct conversion) architecture, it has less severe offset and flicker noise problems. The Sub-sampling receiver amplifies the RF signal and samples it using track-and-hold Subsampling mixer. These architectures provide low-power solution for the short- range communications missions on Mars. Accomplishments to date include: (1) System-level design and simulation of a Double-Differential PSK receiver, (2) Implementation of Honeywell SOI CMOS process design kit (PDK) in Cadence design tools, (3) Design of test circuits to investigate relationships between layout techniques, geometry, and low-frequency noise in SOI CMOS, (4) Model development and verification of on-chip spiral inductors in SOI CMOS process, (5) Design/implementation of low-power low-noise amplifier (LNA) and mixer for low-IF receiver, and (6) Design/implementation of high-gain LNA for sub-sampling receiver. Our initial results show that substantial improvement in power consumption is achieved using SOI CMOS as compared to standard CMOS process. Potential advantages of SOI CMOS for deep-space communication electronics include: (1) Radiation hardness, (2) Low-power operation, and (3) System-on-Chip (SOC) solutions.

Fujikawa, Gene↗

MTW-OPAL: a technology development platform for ultra-intense optical parametric chirped-pulse amplification systems

Optical parametric chirped-pulse amplification implemented using multikilojoule Nd:glass pump lasers is a promising approach for producing ultra-intense pulses (>10 23 W/cm 2 ). We report on the MTW-OPAL Laser System, an optical parametric amplifier line (OPAL) pumped by the Nd:doped portion of the multi-terawatt (MTW) laser. This midscale prototype was designed to produce 0.5-PW pulses with technologies scalable to tens of petawatts. Technology choices made for MTW-OPAL were guided by the longer-term goal of two full-scale OPALs pumped by the OMEGA EP to produce 2 × 25-PW beams that would be co-located with kilojoule–nanosecond ultraviolet beams. Several MTW-OPAL campaigns that have been completed since “first light” in March 2020 show that the laser design is fundamentally sound, and optimization continues as we prepare for “first-focus” campaigns later this year.

42 ENGINEERING↗