Model launcher for wind tunnels Patent
Design and characteristics of device for launching models in wind tunnels without disturbance of air flow
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Design and characteristics of device for launching models in wind tunnels without disturbance of air flow
Air flow thermodynamics for low sonic boom design of supersonic transport configuration
Method for maintaining good performance in gas turbine during air flow distortion
Damper system for alleviating air flow shock loads on wind tunnel models.
Turbulent boundary layer air flow through supersonic convergent-divergent nozzle with heat transfer, considering relationship between temperature and velocity profiles
Hydrogen fuel injection into hot oncoming air flow, investigating boundary layer chemical behavior at stagnation point of diffusion flame
Turbulent incompressible air flow in-stream static pressure fluctuations measurement, describing bleed type pressure transducer theory, design and operational characteristics
Multicomponent nonequilibrium air flow past axisymmetric blunt body, calculating flow distribution at various attack angles with time dependent technique
Axisymmetric inlet design for turboramjet powered hypersonic cruise vehicle, examining effects of spillage and cowl drags on air flow characteristics
Film cooling effectiveness correlation predicts air flow requirement for cooling gas turbine combustors. Turbulent mixing model accounts for mixing rate between cooling film and hot gas stream. Resulting equation correlates data within plus or minus 20 percent.
A dual purpose test was conducted in the propulsion wind tunnel (PWT) to evaluate the performance of an aerospike engine, in the presence of a booster, and obtain forebody and base pressure distributions on the booster in which it is installed. The test item was a 2.5 percent scaled replica of the SERV booster employing a 5 percent spike length aerospike engine installed in the base region of the model. Cold flow air was used to simulate engine jet operation. Two booster configurations were investigated, one on which reentry aerospike engine thermal protection doors were installed, and another where the doors were removed. The data presented are representative of the latter configuration for a Mach number range of 0 to 1.25 at angles of attack of 0 and 8 degrees and 0 degrees angle of sideslip.
The Ames pilot heater is a ceramic regenerative heater that provides high temperature air for aerodynamic and combustion experiments. The development of this heater to provide a heat storage bed with temperature capability of about 4600 R is described. A bed was designed and installed having cored brick elements of yttria-stabilized zirconia. The bed dimensions were 14 inches in diameter by 10 feet high. The thermal stress limitations of the bed were studied and maximum air flow rates based upon these limits were established. A combustion reheat system was designed and installed to provide the necessary control over the bed temperature distribution. The revised heater system was successfully operated at a maximum bed temperature of 4600 R. The successful operation demonstrated that yttria-stabilized zirconia cored brick can satisfy the high temperature-long duration requirement for storage heater applications.
The tone burst technique makes practical the laboratory evaluation of potential inlet and discharge duct treatments. Tone burst apparatus requires only simple machined parts and standard components. Small, simply made, lining samples are quickly and easily installed in the system. Two small electromagnetric loudspeaker drivers produce peak sound pressure level of over 166 db in the 3-square-inch sample duct. Air pump available in most laboratories can produce air flows of over plus and minus Mach 0.3 in the sample duct. The technique uses short shaped pulses of sound propagated down a progressive wave tube containing the sample duct. The peak pressure level output of the treated duct is compared with the peak pressure level output of a substituted reference duct. The difference between the levels is the attenuation or insertion loss of the treated duct. Evaluations of resonant absorber linings by the tone burst technique check attenuation values predicted by empirical formulas based on full scale ducts.
A symmetrical method of optical heterodyning of the Doppler shifted scattered laser radiation developed for velocity measurements with a minimal instrumental spectral broadening and a high signal-to-noise ratio. The method employs two laser beams incident on the moving scatterer and does not use any reference beam for heterodyning. The Doppler signal frequency is independent of the scattering angle and the signal possesses no receiving aperture broadening. Optical alignment is simple. Typical values of the instrumental spectral broadening were approximately 0.8 percent of the center frequency of the Doppler signal, and the signal-to-noise ratio was approximately 25 dB, obtained from an air flow system using submicron dioctylphthalate scattering aerosol. Experimental and theoretical studies were made on the characteristics of the Doppler signal and the effect of system parameters in turbulent flow measurement. The optimization process involved in the beam optics and in the use of a spatial filter is described. For localized flow measurement in any direction of the three-dimensional orthogonal coordinates, the system, using uncorrected optical components, had a sensing volume which can be described by a sensitive length of 600 microns and a diameter of 100 microns.
A test program was conducted to evaluate the altitude relight capabilities of a short-length, double-annular, ram-induction combustor which was designed for Mach 3 cruise operation. The use of distorted inlet-air flow profiles was tried to evaluate their effect on the relight performance. No significant improvement in altitude relight performance was obtained with this approach. A study was also made to determine the effects of the reference Mach number, the fuel temperature, and the fuel volatility (ASTM-A1 against JP-4) on the altitude relight performance. Decreasing the reference Mach number, increasing the fuel temperature, and using more volatile fuel all decrease the combustor pressure necessary for relight.
Microphone sensor transforms pressure variations caused by acoustic signals and turbulence into electrical output. Microphone is protected from direct thrust of slipstream by porous barrier. Airfoil is designed to create no turbulence in air flow over porous surface.
The transmission line inversion problem is applied to the speech communication process. The problem involves acquiring information necessary for synthesis of speech and for making models of the speech production mechanism. Formulation for the problem is derived from an analysis of the human vocal tract functions. It is known that speech sounds are produced by acoustic excitation of the tract by means of quasi-periodic pulses from the vocal cords during vowel sounds and turbulent air flow at various points along the tract during fricative sounds. By assuming plane wave propagation, differential equations are obtained relating the cross sectional area of the tract, the pressure, and the volume velocity. By replacing the pressure factor with a voltage factor and the volume velocity by current, the problem becomes a transmission line problem.
Atom recombination catalytic rates for surface coatings of various candidate thermal protection system materials for the space shuttle vehicle were obtained from measurements in arc jet, air flow. The coatings, chrome oxides, siliconized carbon/carbon, hafnium/tantalum carbide on carbon/carbon, and niobium silicide, were bonded to the sensitive surface of transient slug calorimeters that measured the heat transfer rates to the coatings. The catalytic rates were inferred from these heat transfer rates Surface temperatures of the calorimeters varied from approximately 300 to 410 K.