At least 865 records · Page 48

RELAP5-3D validation studies based on the High Temperature Test facility

In the spring and summer of 2019, experiments were conducted at the High Temperature Test Facility (HTTF) that form the basis of an upcoming high-temperature gas-cooled reactor (HTGR) thermal hydraulics (T/H) benchmark. HTTF is an integral effects test facility for HTGR T/H modeling validation. This paper presents RELAP5-3D models of two of those experiments: PG-27, a pressurized conduction cooldown (PCC); and PG-29, a depressurized conduction cooldown (DCC). These models used the RELAP5-3D model of HTTF originally developed by Paul Bayless as a starting point. The sensitivity analysis and uncertainty quantification code, RAVEN was used to perform calibration studies for the steady-state portion of PG-27. Here we developed four PG-27 calibrations based on steady-state conditions. These calibrations all used an effective thermal conductivity equal to 36 % of the measured thermal conductivity, but they differed with respect to the frictional pressure drops and radial conduction models. These models all captured the trends in steady-state temperature distributions and transient temperature behavior well. All four calibrations show room for improvement in predicting the transient temperature rise. The smallest error in temperature rise during the transient was a 21 % underprediction, and the largest was a 48 % underprediction. The errors in transient temperature rise are largely a result of a mismatch in power density between the RELAP5-3D model and the experiment due to the location of active heater rods along the boundary between heat structures in the model. The best of these calibrations was applied to PG-29 to model the DCC. Once again, temperatures during the transient were underpredicted but trends in temperature were captured. The RELAP5-3D model captured trends in the data but could not reproduce measured temperatures exactly. This result is not attributed to deficiencies in the experimental data or to RELAP5–3D itself. Rather, this result likely arises due to the some of the assumptions and decisions made when the RELAP5-3D model was first developed, prior to the execution of HTTF experiments. An agreement in prediction of temperature trends but challenges reproducing HTTF temperatures within measurement uncertainty is consistent with previous analyses of HTTF in the literature. Future RELAP5-3D validation activities centered around HTTF may be able to provide greater insight into the code’s capabilities for HTGR modeling with a more finely nodalized model.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

OC6 Phase Ib: Validation of the CFD predictions of difference-frequency wave excitation on a FOWT semisubmersible

During the previous OC5 11 project, state-of-the-art mid-fidelity engineering tools for floating wind systems were found to consistently underpredict the nonlinear, low-frequency responses of semisubmersible offshore wind platforms, leading to substantial errors in the structural loads because of low-frequency surge and pitch resonance. To examine this underprediction, a coordinated investigation with computational fluid dynamics (CFD) simulations and model-basin experiments was carried out. Both investigations involved a fixed and simplified OC5-DeepCwind semisubmersible in bichromatic waves. The wave excitations - especially the nonlinear, difference-frequency excitation - on the structure from the CFD simulations were compared to the experimental measurements for validation, with uncertainty analyses for both the experimental and the CFD results. Furthermore, the wave excitations on each column of the semisubmersible were measured separately in the experiment, allowing the validation of the CFD results to be done on a per-column basis. Overall, the CFD predictions of the difference-frequency excitations agree with the experimental measurements, suggesting the CFD solutions can be used as a reference for tuning and improving the engineering-level tools and can provide a means to better understand the underprediction at low frequencies.

16 TIDAL AND WAVE POWER↗

Validation of CFD simulations of the moored DeepCwind offshore wind semisubmersible in irregular waves

This article examines the use of computational fluid dynamics (CFD) simulations to predict the response of a floating wind platform to irregular-wave excitation. This work was conducted as part of the Reproducible CFD Joint Industry Project for Floating Offshore Wind Applications and involved verification across several participants and modeling tools and validation against experiments. The authors pay special attention to the uncertainties in both CFD results and experimental measurements. In this work, we perform detailed comparisons of the incident waves and the motion of a moored structure. The nonlinear, low-frequency resonance motion is of particular interest because it potentially drives the mooring and tower-base loads. The verification and validation study is partially successful in that the CFD simulations capture the low-frequency slow-drift motion well but underpredict the low-frequency pitch resonance. This underprediction can be attributed in part to the CFD incident waves, which showed some discrepancies with the experimental waves, especially around extreme events. The effects of the wave discrepancies are also estimated and investigated using a mid-fidelity OpenFAST model. Overall, the present study increases our confidence in using CFD simulations to predict the global performance of offshore wind platforms in irregular waves and to produce data for the calibration of lower-fidelity models.

17 WIND ENERGY↗

Second-order wave excitation forces in WEC-Sim/MOST: Implementation, experimental validation, and code-to-code comparison

Accurate prediction of second-order hydrodynamic loads is essential for floating bodies, including floating offshore wind turbines, wave energy converters, and hybrid wind–wave platforms. These nonlinear effects, arising from both sum- and difference-frequency forcing, are critical for capturing key response characteristics but remain challenging to model efficiently. In this work, we extend the open-source Wave Energy Converter Simulator / MATLAB for Offshore Simulation Tool by implementing second-order wave excitation forces, supporting both the full Quadratic Transfer Function formulation and the Newman approximation. The full Quadratic Transfer Function method is used for all code-to-code comparisons and experimental validation, while the Newman approximation is provided as a computationally lighter alternative. To benchmark the new capability, we perform a code-to-code comparison with OpenFAST and OrcaFlex. We then validate the enhanced model using wave-tank measurements of a 1:96 scale DeepCwind semi-submersible, showing that second-order effects are required to reproduce platform motions. The implementation employs a computationally efficient pre-computation strategy for second-order wave excitation forces, reducing simulation cost while maintaining engineering accuracy. Overall, this work advances the tool as an open-source and versatile tool for modelling floating offshore renewable-energy systems requiring second-order hydrodynamic fidelity.

17 WIND ENERGY↗

Theory and Implementation of Nuclear Safety System Codes - Part II: System Code Closure Relations, Validation, and Limitations

This is Part II of two articles describing the details of thermal-hydraulic sys- tem codes. In this second part of the article series, the system code closure relationships (used to model thermal and mechanical non-equilibrium and the coupling of the phases) for the governing equations are discussed and evaluated. These include several thermal and hydraulic models, such as heat transfer coefficients for various flow regimes, two phase pressure correlations, two phase friction correlations, drag coefficients and interfacial models be- tween the fields. These models are often developed from experimental data. The experiment conditions should be understood to evaluate the efficacy of the closure models. Code verification and validation, including Separate Effects Tests (SETs) and Integral effects tests (IETs) is also assessed. It can be shown from the assessments that the test cases cover a significant section of the system code capabilities, but some of the more advanced reactor designs will push the limits of validation for the codes. Lastly, the limitations of the codes are discussed by considering next generation power plants, such as Small Modular Reactors (SMRs), analyz- ing not only existing nuclear power plants, but also next generation nuclear power plants. The nuclear industry is developing new, innovative reactor designs, such as Small Modular Reactors (SMRs), High-Temperature Gas-cooled Reactors (HTGRs) and others. Sub-types of these reactor designs utilize pebbles, prismatic graphite moderators, helical steam generators, in- novative fuel types, and many other design features that may not be fully analyzed by current system codes. This second part completes the series on the comparison and evaluation of the selected reactor system codes by discussing the closure relations, val- idation and limitations. These two articles indicate areas where the models can be improved to adequately address issues with new reactor design and development.

99 GENERAL AND MISCELLANEOUS↗

Validation of the single-event method for low-energy electron transport via stopping power calculations with $\mathrm{MCNP}$

Monte Carlo simulations of low-energy ( <50 keV) electron transport in matter are essential for a broad range of application fields. Several Monte Carlo codes have developed specialized treatments for this case, but a comprehensive validation of low-energy electron transport for general-purpose simulations remains lacking in the literature. One approach to accomplish this validation is calculation of stopping power using low-energy electron transport physics, as stopping power is a fundamental radiation transport quantity which must be simulated accurately for nearly any application. Here in this work, we use the Monte Carlo N-Particle (MCNP) radiation transport code with the single-event method for electron transport to calculate stopping powers of low-energy electrons (50 eV to 30 keV) in 41 elemental solids, 14 compound solids, and five rare gas solids, comparing simulation results to published semi-empirical stopping power calculations from optical measurements. In general, the simulations give good agreement (typically within ±10%) with semi-empirical stopping power values at higher energies: 300 eV and above for most elemental solids, 1 keV and above for compound solids, and 400 eV and above for rare gas solids. Agreement between MCNP and semi-empirical values is worse below these energies. The most significant source of error is the EPRDATA14 cross section data, which does not account for changes in electronic structure due to solid-state bonding, particularly in compound materials. The simplistic model of atomic excitation used to generate the EPRDATA14 cross sections is another key source of error. Additionally, the breakdown of the continuous slowing-down approximation introduces significant uncertainty at low energies, although this is a limitation of the calculation method and not of the simulation procedure. Accounting for these and other uncertainty sources, the single event method in MCNP is robust and able to give good accuracy for a variety of low-energy electron transport problems through diverse kinds of materials.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Outcome of the First wwPDB/CCDC/D3R Ligand Validation Workshop

Crystallographic studies of ligands bound to biological macromolecules (proteins and nucleic acids) represent an important source of information concerning drug-target interactions, providing atomic level insights into the physical chemistry of complex formation between macromolecules and ligands. Of the more than 115,000 entries extant in the Protein Data Bank archive, ~75% include at least one non-polymeric ligand. Ligand geometrical and stereochemical quality, the suitability of ligand models for in silico drug discovery/design, and the goodness-of-fit of ligand models to electron density maps vary widely across the archive. We describe the proceedings and conclusions from the first Worldwide Protein Data Bank/Cambridge Crystallographic Data Centre/Drug Design Data Resource (wwPDB/CCDC/D3R) Ligand Validation Workshop held at the Research Collaboratory for Structural Bioinformatics at Rutgers University on July 30-31, 2015. Experts in protein crystallography from academe and industry came together with non-profit and for-profit software providers for crystallography and with experts in computational chemistry and data archiving to discuss and make recommendations on best practices, as framed by a series of questions central to structural studies of macromolecule-ligand complexes. What data concerning bound ligands should be archived in the Protein Data Bank? How should the ligands be best represented? How should structural models of macromolecule-ligand complexes be validated? What supplementary information should accompany publications of structural studies of biological macromolecules? Consensus recommendations on best practices developed in response to each of these questions are provided, together with some details regarding implementation. Important issues addressed but not resolved at the workshop are also enumerated.

59 BASIC BIOLOGICAL SCIENCES↗

A Possible Tool for Checking Errors in the INAA Results, Based on Neutron Data and Method Validation

This work presents preliminary results of a new type of possible application in the INAA experiments of elemental analysis, useful to check errors occurred during investigation of unknown samples; it relies on the INAA method validation experiments and accuracy of the neutron data from the literature. The paper comprises 2 sections, the first one presents--in short--the steps of the experimental tests carried out for INAA method validation and for establishing the 'ACTIVA-N' laboratory performance, which is-at the same time-an illustration of the laboratory evolution on the way to get performance. Section 2 presents our recent INAA results on CRMs, of which interpretation opens discussions about the usefulness of using a tool for checking possible errors, different from the usual statistical procedures. The questionable aspects and the requirements to develop a practical checking tool are discussed.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Experimental validation of a diagnostic technique for tuning the fourth shock timing on National Ignition Facility

Capsule implosions on the National Ignition Facility (NIF) [Lindl et al., Phys. Plasmas 11, 339 (2004)] will be driven with a carefully tailored sequence of four shock waves that must be timed to very high precision in order to keep the fuel on a low adiabat. The Hohlraum conditions present during the first three shocks allow for a very accurate and direct diagnosis of the strength and timing of each individual shock by velocity interferometry. Experimental validation of this diagnostic technique on the OMEGA Laser Facility [Boehly et al., Opt. Commun. 133, 495 (1997)] has been reported in [Boehly et al., Phys. Plasmas 16, 056302 (2009)]. The Hohlraum environment present during the launch and propagation of the final shock, by contrast, is much more severe and will not permit diagnosis by the same technique. A new, closely related technique has been proposed for measuring and tuning the strength and timing of the fourth shock. Experiments to test this technique under NIF-relevant conditions have also been performed on OMEGA. The result of these experiments and a comparison to numerical simulations is presented, validating this concept.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Commissioning and Validation of the First Monte Carlo Based Dose Calculation Algorithm Commercial Treatment Planning System in Mexico

This work presents the beam data commissioning and dose calculation validation of the first Monte Carlo (MC) based treatment planning system (TPS) installed in Mexico. According to the manufacturer specifications, the beam data commissioning needed for this model includes: several in-air and water profiles, depth dose curves, head-scatter factors and output factors (6x6, 12x12, 18x18, 24x24, 42x42, 60x60, 80x80 and 100x100 mm{sup 2}). Radiographic and radiochromic films, diode and ionization chambers were used for data acquisition. MC dose calculations in a water phantom were used to validate the MC simulations using comparisons with measured data. Gamma index criteria 2%/2 mm were used to evaluate the accuracy of MC calculations. MC calculated data show an excellent agreement for field sizes from 18x18 to 100x100 mm{sup 2}. Gamma analysis shows that in average, 95% and 100% of the data passes the gamma index criteria for these fields, respectively. For smaller fields (12x12 and 6x6 mm{sup 2}) only 92% of the data meet the criteria. Total scatter factors show a good agreement (<2.6%) between MC calculated and measured data, except for the smaller fields (12x12 and 6x6 mm{sup 2}) that show a error of 4.7%. MC dose calculations are accurate and precise for clinical treatment planning up to a field size of 18x18 mm{sup 2}. Special care must be taken for smaller fields.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Upgrade and validation on plasma of the Tore Supra CW LHCD generator

A one year-long major upgrade of the 3.7 GHz Lower Hybrid Current Drive (LHCD) generator for the Tore Supra (TS) tokamak has been performed. It consisted in installing a first series of eight Thales Electron Devices (TED) 700 kW CW klystrons, new CW components and auxiliaries, and in modifying the transmitter control and protection software. Modifications and calibration of the sensors and the RF subsystems were completed as well. Finally, the RF power available in the generator has been increased by 35% and the pulse duration could reach 1000 s. A complete validation and optimization of the klystrons have been performed in 2010 on matched load before the generator could enter into operation. The eight klystrons connected with the Full Active Multijunction (FAM) antenna delivered 3.5 MW/50s in December 2010. The upgrade of the generator and the steps to validate the modifications are described.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Civa 10 RX module: Preliminary validation in a nuclear context

The French Institute for Radioprotection and Nuclear Safety (IRSN) in partnership with CEA, has started in 2009 a program over several years for the validation of CIVA RX module. The aim of this paper is to present preliminary results of CIVA RX tools validation. The study consists in a cross comparison between experimental and simulation results. These have been carried out on different objects (step wedge, dissimilar metal weld mock up, IQI, notches) with different sources (Co{sup 60} and 450 kV X-ray tube) and radiographic film. Simulation and experimental data are compared in term of optical density, IQI perceptivity and flaws detectability. This study shows a good agreement between experiment and simulation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

ESA DUE GlobVapour water vapor products: Validation

The main objective of the European Space Agency (ESA) Data User Element (DUE) GlobVapour project was the development of multi-annual global water vapor data sets. Since water vapour is a key climate variable it is important to have a good understanding of its behavior in the climate system. The ESA DUE GlobVapour project provides water vapor data, including error estimates, based on carefully calibrated and inter-calibrated satellite radiances in response to user requirements for long time series satellite observations. ESA DUE GlobVapour total columnar water vapor (TCWV) products derived from GOME/SCIA/GOME-2 (1996-2008) and SSM/I+MERIS (2003-2008) have been validated for the mentioned period, using satellite-based (AIRS, ATOVS) and ground-based measurements (radiosondes and microwave radiometer). The validation results are discussed in the following. The technical specifications on bias (1 kg/m{sup 2} for SSMI+MERIS and 2 kg/m{sup 2} for GOME/SCIA/GOME-2) are generally met. For more information, documents and data download follow the link: www.globvapour.info.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Laser Doppler vibrometry for assessment of arteriosclerosis: A first step towards validation

It has been shown that in cardiovascular risk management, stiffness of large arteries has a very good predictive value for cardiovascular disease and mortality. This parameter can be estimated from the pulse wave velocity (PWV) measured between the common carotid artery (CCA) in the neck and femoral artery (FA) in the groin. However PWV can also be measured locally in the CCA, using non-invasive methods such as ultrasound (US) or laser Doppler vibrometry (LDV). Potential of the latter approach was already explored in previous research, and in this work a first step towards clinical validation is made. 50 hypertension II/III patients aged between 30 and 65 participate in the study. Patients were asked to remain sober for 4 hours prior to the measurements. The trajectory of the CCA in the neck was determined by a trained clinician guided by an US probe. 3 laser Doppler vibrometer (LDV) systems were aimed along the CCA. PWV was then calculated from the distance between beams and the time-shift between waveforms. Immediately after LDV measurements, PWV was measured with US. Additionally, carotid-femoral PWV was measured. As a validation, PWV results of the different techniques were compared with each other, and with medical background of the test subjects. Since data acquisition is still ongoing, data from only 20 patients will be discussed. No trends between measurement methods for PWV are apparent. However, a positive trend was detected between PWV as measured with LDV and blood pressure. More data, including additional experiments will be needed to verify this observation.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

X-ray digital industrial radiography (DIR) for local liquid velocity (V{sub LL}) measurement in trickle bed reactors (TBRs): Validation of the technique

Local liquid velocity measurements in Trickle Bed Reactors (TBRs) are one of the essential components in its hydrodynamic studies. These measurements are used to effectively determine a reactor's operating condition. This study was conducted to validate a newly developed technique that combines Digital Industrial Radiography (DIR) with Particle Tracking Velocimetry (PTV) to measure the Local Liquid Velocity (V{sub LL}) inside TBRs. Three millimeter-sized Expanded Polystyrene (EPS) beads were used as packing material. Three validation procedures were designed to test the newly developed technique. All procedures and statistical approaches provided strong evidence that the technique can be used to measure the V{sub LL} within TBRs.

42 ENGINEERING↗

Ultrasonic linear array validation via concrete test blocks

Oak Ridge National Laboratory (ORNL) comparatively evaluated the ability of a number of NDE techniques to generate an image of the volume of 6.5′ X 5.0′ X 10″ concrete specimens fabricated at the Florida Department of Transportation (FDOT) NDE Validation Facility in Gainesville, Florida. These test blocks were fabricated to test the ability of various NDE methods to characterize various placements and sizes of rebar as well as simulated cracking and non-consolidation flaws. The first version of the ultrasonic linear array device, MIRA [version 1], was one of 7 different NDE equipment used to characterize the specimens. This paper deals with the ability of this equipment to determine subsurface characterizations such as reinforcing steel relative size, concrete thickness, irregularities, and inclusions using Kirchhoff-based migration techniques. The ability of individual synthetic aperture focusing technique (SAFT) B-scan cross sections resulting from self-contained scans are compared with various processing, analysis, and interpretation methods using the various features fabricated in the specimens for validation. The performance is detailed, especially with respect to the limitations and implications for evaluation of a thicker, more heavily reinforced concrete structures.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Prototyping and validating requirements of radiation and nuclear emergency plan simulator

Organizational incapability in developing unrealistic, impractical, inadequate and ambiguous mechanisms of radiological and nuclear emergency preparedness and response plan (EPR) causing emergency plan disorder and severe disasters. These situations resulting from 65.6% of poor definition and unidentified roles and duties of the disaster coordinator. Those unexpected conditions brought huge aftermath to the first responders, operators, workers, patients and community at large. Hence, in this report, we discuss prototyping and validating of Malaysia radiation and nuclear emergency preparedness and response plan simulation model (EPRM). A prototyping technique was required to formalize the simulation model requirements. Prototyping as systems requirements validation was carried on to endorse the correctness of the model itself against the stakeholder’s intensions in resolving those organizational incapability. We have made assumptions for the proposed emergency preparedness and response model (EPRM) through the simulation software. Those assumptions provided a twofold of expected mechanisms, planning and handling of the respective emergency plan as well as in bringing off the hazard involved. This model called RANEPF (Radiation and Nuclear Emergency Planning Framework) simulator demonstrated the training emergency response perquisites rather than the intervention principles alone. The demonstrations involved the determination of the casualties’ absorbed dose range screening and the coordination of the capacity planning of the expected trauma triage. Through user-centred design and sociotechnical approach, RANEPF simulator was strategized and simplified, though certainly it is equally complex.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Validations of calibration-free measurements of electron temperature using double-pass Thomson scattering diagnostics from theoretical and experimental aspects

This paper evaluates the accuracy of electron temperature measurements and relative transmissivities of double-pass Thomson scattering diagnostics. The electron temperature (T{sub e}) is obtained from the ratio of signals from a double-pass scattering system, then relative transmissivities are calculated from the measured T{sub e} and intensity of the signals. How accurate the values are depends on the electron temperature (T{sub e}) and scattering angle (θ), and therefore the accuracy of the values was evaluated experimentally using the Large Helical Device (LHD) and the Tokyo spherical tokamak-2 (TST-2). Analyzing the data from the TST-2 indicates that a high T{sub e} and a large scattering angle (θ) yield accurate values. Indeed, the errors for scattering angle θ = 135° are approximately half of those for θ = 115°. The method of determining the T{sub e} in a wide T{sub e} range spanning over two orders of magnitude (0.01–1.5 keV) was validated using the experimental results of the LHD and TST-2. A simple method to provide relative transmissivities, which include inputs from collection optics, vacuum window, optical fibers, and polychromators, is also presented. The relative errors were less than approximately 10%. Numerical simulations also indicate that the T{sub e} measurements are valid under harsh radiation conditions. This method to obtain T{sub e} can be considered for the design of Thomson scattering systems where there is high-performance plasma that generates harsh radiation environments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗